Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photonic crystals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The emission of atoms and molecules accompanying fracture of single-crystal MgO

The emission of particles due to deformation and fracture of materials has been investigated. The emission of electrons (exoelectron emission), ions, neutral species, photons (triboluminescence), as well as long wavelength electromagnetic radiation was observed; collectively these emissions are referred to as fractoemission. This paper describes measurements of the neutral emission accompanying the fracture of single-crystal MgO. Masses detected are tentatively assigned to the emission of H2, CH4, H2O, CO, O2, CO2, and atomic Mg. Other hydrocarbons are also observed. The time dependencies of some of these emissions relative to fracture are presented for two different loading conditions.

Dickinson, J. T.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Electro-optic crystals and their use for light modulation

Several methods of modulating a beam of light, which have been described in the literature, utilizing the influence of an electrical signal on the birefringence of certain crystals, will be reviewed. These employ optics which respond to the state of polarization of a light beam, and include intensity modulation, position modulation, and the possibility of an electrically tuned optical filter. The influence of the piezo-optic, or strain contribution to the total electro-optic response in the design of an optoelectronic device will be discussed. Current experimental work in our laboratory in which the strain contribution is separated from the direct effect will be described. The strain-free effect is measured by applying a step voltage to the crystal, and observing the initial response. The electro-optical transient response can be observed with nanosecond time resolution. An electronic sampling technique is used to extract the desired response from photon noise. The stress-free or low-frequency effect is measured similarly but at low audio frequencies. Single crystal tetragonal BaT10 3 has been investigated in detail with the result that the strain-optic contribution to the low frequency effect r_(c) = r_(33)—r_(13) is about 80% of the total, where it is only 10% in KDP and 45% in ADP. The magnitudes of the electro-optic effect, dielectric constant, and other related properties are compared for several materials potentially useful as electro-optic modulators, and some comments are made about the practical problems of building a modulator.

ELECTRO-OPTICS↗

Bragg crystal polarimeters

A Bragg crystal oriented at 45 deg to an incoming beam of X-rays acts as a polarization analyzer. This crystal geometry preferentially reflects those X-rays that satisfy the Bragg condition and whose electric vectors are perpendicular to the plane defined by the incident and reflected photons. X-rays with electric vectors parallel to this plane of incidence are photoelectrically absorbed. The energy bandwidth of nearly perfect crystals is extremely small, which makes them very inefficient X-ray polarimeters. This limitation is particularly acute for observations of the relatively weak X-ray continuum of stellar sources. The bandwidth can be greatly increased by employing mosaic or ideally imperfect crystals. Mosaic crystals possess a high integrated reflectivity, which results in a large increase in the reflection of continuum radiation. A review of the theory and performance characteristics of crystal polarimeters designed for observations of cosmic X-ray sources is presented.

Silver, E.↗

Spatial Phase Imaging

Frequently, scientists grow crystals by dissolving a protein in a specific liquid solution, and then allowing that solution to evaporate. The methods used next have been, variously, invasive (adding a dye that is absorbed by the protein), destructive (crushing protein/salt-crystal mixtures and observing differences between the crushing of salt and protein), or costly and time-consuming (X-ray crystallography). In contrast to these methods, a new technology for monitoring protein growth, developed in part through NASA Small Business Innovation Research (SBIR) funding from Marshall Space Flight Center, is noninvasive, nondestructive, rapid, and more cost effective than X-ray analysis. The partner for this SBIR, Photon-X, Inc., of Huntsville, Alabama, developed spatial phase imaging technology that can monitor crystal growth in real time and in an automated mode. Spatial phase imaging scans for flaws quickly and produces a 3-D structured image of a crystal, showing volumetric growth analysis for future automated growth.

Source record↗

Evaluation of advanced light scattering technology for microgravity experiments

The capabilities of modern light scattering equipment and the uses it might have in studying processes in microgravity are evaluated. Emphasis is on the resolution of polydisperse systems. This choice was made since a major use of light scattering was expected to be the study of crystal growth of macromolecules in low gravity environments. An evaluation of a modern photon correlation spectrometer and a Mie spectrometer is presented.

Fredericks, W. J.↗

Conformal Membrane Reflectors for Deployable Optics

This presentation reports the Phase I results on NASA's Gossamer Spacecraft Exploratory Research and Technology Program. Cornerstone Research Group, Inc., the University of Rochester, and International Photonics Consultants collaborated to investigate the feasibility of free-standing, liquid-crystal-polymer (LCP) reflectors for integration into space-based optical systems. The goal of the program was to achieve large-diameter, broadband. reflective membranes that are resistant to the effects of space, specifically cryogenic environments and gamma-ray irradiation. Additionally, we assessed the applicability of utilizing the technology as tight sails, since, by their very nature, these films offer high-reflectivity at specified wavelengths. Previous research programs have demonstrated all-polymer, narrow-band Specular reflectors and diffuse membrane reflectors. The feasibility of fabricating an all-polymer broadband specular reflector and a narrow-band specular membrane reflector was assessed in the Phase I Gossamer program. In addition, preliminary gamma irradiation studies were conducted to determine the stability of the polymer reflectors to radiation. Materials and process technology were developed to fabricate coupon-scale reflectors of both broad- and narrow-band specular reflectors in Phase 1. This presentation will report the results of these studies, including, the performance of a narrow-band specular membrane. Gamma irradiation exposures indicate limited impact on the optical performance although additional exposure studies are warranted. Plans to scale up the membrane fabrication process will be presented.

Hood, Patrick J.↗

Demonstration of a Compact Franson Interferometer for Highly Non-degenerate Time-energy Entangled Photons

We present results from a time-energy entanglement Bell inequality violation measurement of two highly non-degenerate photons using a compact Franson interferometer. The entangled photons are generated via the spontaneous parametric downconversion of a 532 nm pump photon into time-energy and polarization degrees of freedom hyper-entangled 810 nm and 1550 nm photons. The source is a type II periodically poled potassium titanyl phosphate (KTP) crystal with a fiber-coupled input and free-space output. These wavelengths are of particular interest as they lie at the intersection of free-space quantum communication and terrestrial entanglement distribution due to 810 nm undergoing little atmospheric absorption, making it a candidate for satellite to ground quantum links. Furthermore, 1550 nm is capable of directly interfacing with existing telecommunications infrastructure. We report an initial violation of Bell's inequality by more than 3 standard deviations and describe efforts to improve upon this while maintaining stable operation in a low size, weight, and power (SWaP) package.

A J Fallon↗

A focussing iron line crystal spectrometer for Spacelab

A crystal spectrometer system is described which employs conical focusing of 12 curved LiF crystal panels to minimize the detector size and reduce the background counting rate. The wavelength range from 1.70 to 1.98 A is covered, including the resonance lines of Fe XXV and Fe XXVI as well as the Fe I K-alpha line and absorption edge. Operation of the spectrometer is discussed, noting that diffracted X-rays are registered in one-dimensional position-sensitive detectors and that the arrival position of a photon in a detector is related to its wavelength due to the fixed curvature of the crystal panels in the dispersion plane. Some characteristics of the multianode position-sensitive detectors are reviewed along with the crystal arrangement and mounting. The instrument sensitivity is evaluated in relation to the strengths of 6.7-keV emission features detected by the Ariel 5 and OSO 8 proportional-counter spectrometers.

Catura, R. C.↗

Optical communications for future deep-space missions

The development of key technologies for an optical communications system for deep-space probes is discussed. Aspects of the technology include the pulse-position modulation technique for data transmission, a solid-state laser with a Nd:YAG crystal end, nondiffraction-limited receivers, and the application of avalanche photodiodes to improve photon detection. Mission benefits and flight opportunities and applications are discussed. Experiments to test optical communication systems are being planned for the Space Shuttle and the Mars Rover Sample Return misson. Future missions which will probably use the system include Cassini and the Mariner Mark II.

Rayman, Marc D.↗

Microgravity Program strategic plan, 1991

The all encompassing objective of the NASA Microgravity Program is the use of space as a lab to conduct research and development. The on-orbit microgravity environment, with its substantially reduced buoyancy forces, hydrostatic pressures, and sedimentation, enables the conduction of scientific studies not possible on Earth. This environment allows processes to be isolated and controlled with an accuracy that cannot be obtained in the terrestrial environment. The Microgravity Science and Applications Div. has defined three major science categories in order to develop a program structure: fundamental science, including the study of the behavior of fluids, transport phenomena, condensed matter physics, and combustion science; materials science, including electronic and photonic materials, metals and alloys, and glasses and ceramics; and biotechnology, focusing on macromolecular crystal growth as well as cell and molecular science. Experiments in these areas seek to provide observations of complex phenomena and measurements of physical attributes with a precision that is enabled by the microgravity environment.

Source record↗

Microscopes on ISS - Present and Future Possibilities

The attached slides are for an invited talk (invitation from Ken Savins at CASIS) to be given July 19 at the "2018 Microgravity Molecular Crystal Growth Workshop". Ken Savins indicated that the protein crystal growth community would benefit from knowing more about what is available on ISS for microscopy. It is especially important that the folks growing protein crystals start to use the microscopes on ISS as diagnostic tools so that when their samples are returned to Earth and the results are unexpected, they are able to determine whether or not the return flight had an impact. In additional to preparing this presentation describing present and possible future LMM capabilities (if it is refurbished), we worked with Rachel A Ormsby (techshot) and Devin Ridgley (HNu Photonics) to add slides and a movie they provided of their capacities. Contact information for the NASA GRC Liquid Crystal Facility (LCF) will be included, and a couple of slides for LCF may be added when the contractor (James Kolibas at ZIN Technology) returns from vacation.

protein crystals↗

Photocatalytic Coatings for Exploration and Spaceport Design

This project developed self-cleaning photocatalytic coatings that remove contamination without human intervention. The coatings chemically remove organic contaminants and leave no residue. The photocatalyst will not negatively affect other coating properties, especially corrosion resistance. Titanium dioxide, TiO2, is an extremely popular photocatalyst because of its chemical stability, nontoxicity, and low cost. TiO2 is commonly used in the photocatalytic oxidation of organic matter or pollutants in the gas and liquid phases. However, TiO2 does have some drawbacks. It has limited light absorption because of its large band-gap and suffers from a photonic efficiency of less than 10 percent for organic degradation. Dopants can lower the band-gap and improve efficiency. Since the photocatalytically active form of TiO2 is a nanocrystalline powder, it can be difficult to make a robust coating with enough catalyst loading to be effective. Photocatalysts become active when certain light energy is absorbed. When photons with an energy greater than the band-gap, Eg, (wavelengths shorter than 400 nm) impinge upon the surface of the TiO2, an electron-hole pair is formed. The electron-hole pair oxidizes adsorbed substances either directly or via reactive intermediates that form on the surface, such as hydroxyl radicals (OH) or superoxide ions (O2-). Several factors can influence the band-gap energy of TiO2, two of which are crystal structure and impurities. TiO2 exists as three crystal structures brookite, anatase, and rutile that can be controlled via heat treatment. Anatase is the most photocatalytically active crystal form of TiO2. Doping TiO2 with impurities can alter its band-gap energy, as well as its effectiveness as a catalyst. Depending on their size, dopant atoms can occupy either the substitutional or interstitial lattice positions. Atoms that are relatively large will assume the interstitial positions and create a much greater energy disturbance in the crystal than will smaller atoms that take on the substitutional positions. This energy disturbance narrows the band-gap and thus allows photons with longer wavelengths and smaller energies (such as those in the visible-light spectrum) to create electron-hole pairs. Raman spectroscopy was performed for the purpose of determining the crystal structure and the degree of crystallinity of the TiO2 particles. Reflectance measurements indicated the wavelengths of light absorbed by the different catalysts.

Source record↗

Large-area multi-crystal NaI/Tl/ detectors for X-ray and gamma-ray astronomy

An array of large multicrystal NaI(Tl) detectors was constructed and used in a balloon-borne experiment to observe weak transient bursts of cosmic origin. The array had an active area of about 1 sq m and was sensitive to photons above 50 keV. Localized bursts which were observed are attributed to long-lived phosphorescence following large energy deposits by cosmic rays in the crystals.

Fishman, G. J.↗

Semiconductor electrolyte photovoltaic energy converter

Feasibility and practicality of a solar cell consisting of a semiconductor surface in contact with an electrolyte are evaluated. Basic components and processes are detailed for photovoltaic energy conversion at the surface of an n-type semiconductor in contact with an electrolyte which is oxidizing to conduction band electrons. Characteristics of single crystal CdS, GaAs, CdSe, CdTe and thin film CdS in contact with aqueous and methanol based electrolytes are studied and open circuit voltages are measured from Mott-Schottky plots and open circuit photo voltages. Quantum efficiencies for short circuit photo currents of a CdS crystal and a 20 micrometer film are shown together with electrical and photovoltaic properties. Highest photon irradiances are observed with the GaAs cell.

Anderson, W. W.↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Raman scattering from phonons and magnons in magnetic semiconductors, MnTe

Comparisons are made between theoretical and experimental data on laser Raman scattering by phonons and two-magnons in antiferromagnetic and paramagnetic phases of MnTe. The study was performed specifically to characterize the magnetic exchange coupling constants of the Mn ions in the samples. Crystal MnTe samples were bombarded with an Ar ion laser beam to obtain spectrometer and photon counter data. One E(2g) phonon with a room temperature energy of 178/cm and a two-magnon peak of 360/cm were observed in the Raman spectrum. A spin wave dispersion relation is presented for the spectrum. Finally, a Monte Carlo technique was used to calculate the two-magnon joint density of states that best fits the experimental data.

Mobasser, S. R.↗