Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photovoltaic Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Effects of Soiling of Photovoltaic Modules and Systems in Brazil’s Climate Zones

This research presents a methodology for quantifying soiling loss in p-Si and CdTe photovoltaic modules through measurements from soiling stations installed in Belo Horizonte (-19.92° S, -43.99° W), Porto Alegre (-30.05° S, -51.17° W), Brotas de Macaúbas (12.0011° S, -42.6303° W), and Macapá (0.0356° N, -51.0705° W), in Brazil. The electrical parameters measured from photovoltaic modules are compared with precipitation data collected in the same location, with the objective of evaluating the behavior of the soiling ratio during the dry periods. Mathematical models determined the SRatio and SRate for each site (in compliance with the IEC-61324-1 monitoring standard [1]). The SRatio for short-circuit current and maximum power data from the modules were evaluated and compared, characterizing the potential effects of uniform and non-uniform soiling. In addition, a method for analyzing energy-production data of PV systems in order to extract the soiling rate was developed and is presented. The gravimetric soiling densities (mg/m2) was determined using the modeling by Coello and Boyle [2] and these are compared to data collected using the Figgis soiling microscope [3].

climate zone↗

Tearing and reliability of photovoltaic module backsheets

We report that the backsheet in photovoltaic modules belongs to an important class of layered materials where the tearing behavior of the individual layers does not necessarily represent the tearing behavior of the entire backsheet. Such characteristic arises from the interaction between the individual layers during the tearing process, where one layer of the backsheet is mechanically constrained by its neighboring layers and the layers may debond from each other. The mechanical constraint and debonding change the amount of energy dissipated during tearing and affect the overall tearing energy. In this article, we exposed a wide selection of backsheets with polymers including ethylene-vinyl acetate (EVA), polyethylene terephthalate (PET), polyvinylidene fluoride (PVDF), and ethylene tetrafluoroethylene (ETFE) to damp heat (85°C/85%RH) for up to 2000 hours. We report on the effect of damp heat on the tearing energy as a function of damp heat exposure. We developed a model that describes the tearing energy of a layered structure by accounting for the tearing of the individual layers in the backsheet, the effect of mechanical constraint, and the adhesive debonding between the layers. Additionally, we explore the relationship between the microstructural change in the polymers which resulted from the damp heat exposure and the mechanical properties using modulated differential scanning calorimetry (MDSC), small and wide angle X-ray scattering (SAXS and WAXS), and tensile testing.

36 MATERIALS SCIENCE↗

Formed photovoltaic module busbars

A cell connection piece for a photovoltaic module is disclosed herein. The cell connection piece includes an interconnect bus, a plurality of bus tabs unitarily formed with the interconnect bus, and a terminal bus coupled with the interconnect bus. The plurality of bus tabs extend from the interconnect bus. The terminal bus includes a non-linear portion.

14 SOLAR ENERGY↗

Surface Stress Characterization and Trends in Thermally Strengthened Photovoltaic Module Glass

Simultaneous changes in photovoltaic (PV) module architecture-such as increased area, replacing the polymeric backsheet with a glass backsheet, and reducing glass thickness from 3.2 to 2.0 mm-have resulted in a novel failure called spontaneous glass breakage. Spontaneous glass breakage results in front and/or rear glass failure without any obvious cause. The resulting low-energy fracture patterns have raised concerns about the thermal strengthening in 2.0-mm glass. We present validation of a nondestructive method for measuring the glass surface stress in PV modules. We use a scattered light polariscope to examine the glass properties of 11 modules from 6 solar fields, with and without spontaneous glass breakage. Based on a Mann-Whitney test p-value of 1.4 x 10-6, we conclude that there is a correlation between lower surface stress and susceptibility to spontaneous breakage. A Kendall's Tau test p-value of 2.0 x 10-4 indicates a correlation between increased module area and lower surface stress. We find that 2.0-mm glass can be, and often is, fully tempered (surface stress ≥69 MPa), but inspecting the fracture pattern is not a reliable way to assess the amount of thermal strengthening. A combination of factors, not just surface stress, influences glass breakage.

14 SOLAR ENERGY↗

Comprehensive study of performance degradation of field‐mounted photovoltaic modules in India

Abstract The All India Survey of Photovoltaic Module Reliability 2014 is an enhanced version of the survey conducted in the previous year, with detailed characterization of PV modules including current‐voltage, infrared and electroluminescence imaging, visual inspection, insulation resistance test and interconnect breakage test. More than a thousand modules were inspected in the field and the main results of the survey are presented in this paper. The average P max degradation rate for the so‐called ‘good’ modules (Group X) is 1.33%/year which is higher than that commonly projected by manufacturers, and widely employed in financial calculations. Modules falling in the ‘not‐so‐good’ category (Group Y) show even higher degradation rates, and it is at least partly due to higher number of micro‐cracks in the modules, and increased degradation of the packaging materials like encapsulant, backsheet, etc. Modules in ‘Hot’ climates degrade faster than modules in the ‘Non‐Hot’ climates. Degradation in fill factor is the primary cause for performance degradation in the young modules (ages <5 years), whereas short‐circuit current degradation is the main contributor to power degradation in the older modules. Small installations (<100 kW p capacity) show higher degradation than large systems, which may be partly due to lack of proper due diligence by the owner at the time of procurement and installation.

Dubey, Rajiv↗

Field Aging of Photovoltaic Module Packaging Materials: DuraMAT Field Module Library

To understand and develop models for silicon photovoltaic module degradation, accelerated testing is often used, however, outdoor field testing is necessary for validation. Outdoor field testing publications are often limited by the lack of a pristine, control module to compare the fielded module to. In this work, commercially available modules were purchased from seven different manufacturers for outdoor fielding then destructive characterization to investigate packaging material degradation on

14 SOLAR ENERGY↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Trial-Run of a Junction-Box Attachment Test for Use in Photovoltaic Module Qualification: Preprint

Engineering robust adhesion of the junction box (j-box) is a hurdle typically encountered by photovoltaic module manufacturers during product development and manufacturing process control. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp-heat,' 'thermal-cycle,' or 'creep' tests within the IEC qualification protocol is proposed to verify the basic robustness of the adhesion system. The details of the proposed test are described, in addition to a trial-run of the test procedure. The described experiments examine four moisture-cured silicones, four foam tapes, and a hot-melt adhesive used in conjunction with glass, KPE, THV, and TPE substrates. For the purpose of validating the experiment, j-boxes were adhered to a substrate, loaded with a prescribed weight, and then subjected to aging. The replicate mock-modules were aged in an environmental chamber (at 85 degrees C/85% relative humidity for 1000 hours; then 100 degrees C/<10% relative humidity for 200 hours) or fielded in Golden (CO), Miami (FL), and Phoenix (AZ) for one year. Attachment strength tests, including pluck and shear test geometries, were also performed on smaller component specimens.

14 SOLAR ENERGY↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

A Performance Model for Photovoltaic Modules with Integrated Microinverters

Photovoltaic (PV) systems using microinverters are becoming increasingly popular in the residential system market, as such systems offer several advantages over PV systems using central inverters. PV modules with integrated microinverters, termed AC modules, are emerging to fill this market space. Existing test procedures and performance models designed for separate DC and AC components are unusable for AC modules because these do not allow ready access to the intermediate DC bus. Sandia National Laboratories' Photovoltaics and Distributed Systems department has developed a set of procedures to test, characterize, and model PV modules with integrated microinverters. The resulting empirical model is able to predict the output AC power of with RMS error of 1-2%. This document describes these procedures and provides the results of model validation efforts.

14 SOLAR ENERGY↗

Estimating Parameters for the PVsyst Version 6 Photovoltaic Module Performance Model

We present an algorithm to determine parameters for the photovoltaic module performance model encoded in the software package PVsyst™ version 6. Our method operates on current-voltage (I-V) measured over a range of irradiance and temperature conditions. We describe the method and illustrate its steps using data for a 36 cell crystalline silicon module. We qualitatively compare our method with one other technique for estimating parameters for the PVsyst™ version 6 model.

14 SOLAR ENERGY↗

Microsystem enabled photovoltaic modules and systems

A microsystem enabled photovoltaic (MEPV) module including: an absorber layer; a fixed optic layer coupled to the absorber layer; a translatable optic layer; a translation stage coupled between the fixed and translatable optic layers; and a motion processor electrically coupled to the translation stage to controls motion of the translatable optic layer relative to the fixed optic layer. The absorber layer includes an array of photovoltaic (PV) elements. The fixed optic layer includes an array of quasi-collimating (QC) micro-optical elements designed and arranged to couple incident radiation from an intermediate image formed by the translatable optic layer into one of the PV elements such that it is quasi-collimated. The translatable optic layer includes an array of focusing micro-optical elements corresponding to the QC micro-optical element array. Each focusing micro-optical element is designed to produce a quasi-telecentric intermediate image from substantially collimated radiation incident within a predetermined field of view.

14 SOLAR ENERGY↗

Stress and Fracture of Crystalline Silicon Cells in Solar Photovoltaic Modules – A Synchrotron X-ray Microdiffraction based Investigation

Fracture of crystalline silicon (c-Si) solar cells in photovoltaic modules is a big concern to the photovoltaics (PV) industry. Cell cracks cause performance degradation and warranty issues to the manufacturers. The roots of cell fractures lie in the manufacturing and integration process of the cells and modules as they go through a series of elevated temperature and pressure processes, involving bonding of dissimilar materials, causing residual stresses. Evaluation of the exact physical mechanisms leading to these thermomechanical stresses is highly essential to quantify them and optimize the PV modules to address them. Here we present a novel synchrotron X-ray microdiffraction based techniques to characterize the stress and fracture in the crystalline silicon PV modules. We show the detailed stress state after soldering and lamination process, using the synchrotron X-ray microdiffraction experiments. We also calculate the maximum tolerable microcrack size in the c-Si cells to sustain the residual stress after lamination. We further demonstrate the effect of these residual stresses on the cell fractures using the widely accepted fracture (4-point bending) tests. These test results show that the soldering and lamination induced localized residual stresses indeed reduce the load-carrying capacity of the c-Si cells.

14 SOLAR ENERGY↗

Onymous early‐life performance degradation analysis of recent photovoltaic module technologies

Abstract The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates ( Rd ) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

14 SOLAR ENERGY↗

Analyzing photovoltaic module mechanics using composite plate theories and finite element solutions

Deflection and stress calculated from an experimentally validated, high-fidelity finite element model (FEM) of a photovoltaic module experiencing mechanical load was compared to results from a simplified FEM treating the module laminate as a homogenized composite using a rule of mixtures approach, and further compared to analytical calculations treating the module as a Kirchoff-Love flat plate. The goal of this study was to determine the error incurred by analyzing module mechanics with varying levels of simplification, since resolving the aspect ratios of a module is computationally expensive. Homogenized FEMs were found to underpredict peak deflection under a 1.0 kPa load by between 13 and 19% for lower and upper bound application of the rule of mixtures. However, module shape was captured, implying that a useful replication of a resolved model could be achieved with a reduced, calibrated material stiffness. Homogenized stress results captured glass layer tensile stress components to within 46 to 52% at a sample location of interest, though agreement was poor through the remainder of the laminate due to the lack of material resolution. For plate theory, deflection was overpredicted by 45 to 67% for upper and lower bound homogenizations, and frame-adjacent module shapes were not adequately replicated. Stress results mirrored FEM trends but magnitudes were not well correlated to resolved model values. These results support the use of homogenized laminate models for module shape derivation, though resolved models remain necessary for stress analyses. The accuracy of plate theory was found to be inadequate for most applications.

14 SOLAR ENERGY↗

Photovoltaic module with removable wind deflector

A photovoltaic (PV) module assembly including a PV module, a deflector, and a clip. The PV module includes a PV device and a frame. A PV laminate is assembled to the frame, and the frame includes a support arm forming a seat. The deflector defines a front face and a rear face, with the clip extending from either the trailing frame member or the rear face of the deflector. In a mounted state, the deflector is nested within the seat and is releasably mounted to the trailing frame member via the clip. In some embodiments, the support arm forms a second seat, with the PV module assembly providing a second mounted state in which the deflector is in a differing orientation/slope, nested within the second seat and releasably mounted to the trailing frame member via the clip.

14 SOLAR ENERGY↗