Search NASA⌕ Search

SEARCH · Search NASA

Results for “Physical Endurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Global Security: 5-10 Year Strategy [Slides]

Global Security delivers innovative engineering solutions to protect the nation from strategic threats home and abroad. Global Security programs focus on developing and implementing technical solutions to address global security challenges through three enduring missions: Global Monitoring, Preventing Proliferation, and Nuclear Weapon Security.

42 ENGINEERING↗

Water and electrolytes

It has been found that the performance of the strongest and fittest people will deteriorate rapidly with dehydration. The present paper is concerned with the anatomy of the fluid spaces in the body, taking into account also the fluid shifts and losses during exercise and their effects on performance. Total body water is arbitrarily divided into that contained within cells (cellular) and that located outside the cells (extracellular). The anatomy of body fluid compartments is considered along with the effects of exercise on body water, fluid shifts with exercise, the consequences of sweating, dehydration and exercise, heat acclimatization and endurance training, the adverse effects of dehydration, thirst and drinking during exercise, stimuli for drinking, and water, electrolyte, and carbohydrate replacement during exercise. It is found that the deterioration of physical exercise performance due to dehydration begins when body weight decreases by about 1 percent.

Greenleaf, J. E.↗

Counter Unmanned Aircraft System (CUAS) Implementation Storyline

This report is an FY21 Deliverable for NA-21.1, International Nuclear Security, WBS 21.1.1.1.4 Counter Unmanned Aircraft Systems (CUAS), under C.1.4, Develop Suite of Engagement Materials and Tools for Country/Regional Teams. The responsibility for protecting nuclear assets is an immense challenge for governments. Policy changes based on geopolitics, instability of government regimes, and technological advances that facilitate theft of nuclear material all contribute to the enduring task of staying current with these and other threats. One of the recent threats to come along is the use of drones or Unmanned Aircraft Systems (UAS) to circumvent traditional Physical Security Systems. There are significant resources invested on physical protection systems for securing nuclear assets, but many of these systems can now be bypassed by simply flying over these measures intended to guard against ground attacks. In recent years the threat increased to hostile groups to attack or surveil due to advances and availability of UAS platforms. It is now more urgent to implement systems and procedures to counter the UAS threat. The United States (U.S.) federal government granted authority to the Department of Energy (DOE) to implement a Counter UAS to protect nuclear assets. This document provides a very practical and transparent view of the trials, tribulations and challenges we encountered while implementing the first Counter-Unmanned Aircraft System (CUAS) Program in the DOE at Los Alamos National Laboratory (LANL).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

R&D Program for HEP High-Power Targets at Fermilab

A high-power target system is a key beam element to complete future High Energy Physics (HEP) experiments. In the recent past, major accelerator facilities have been limited in beam power not by their accelerators, but by the beam intercepting device survivability. The target must then endure high power pulsed beam, leading to high cycle thermal stresses/pressures and thermal shocks. The increased beam power will also create significant challenges such as corrosion and radiation damage that can cause harmful effects on the material and degrade their mechanical and thermal properties during irradiation. This can eventually lead to the failure of the material and drastically reduce the lifetime of targets and beam intercepting devices. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase projects of the future, it is essential to develop a strong R&D program and have synergy with various expertise. After presenting the high power targetry challenges facing next generation multi-MW accelerators, we will give an overview of Fermilab’s R&D program in support of High Power Targetry development. The RaDIATE collaboration (Radiation Damage In Accelerator Target Environment), managed by Fermilab, also draws on existing expertise in related fields to execute a coordinated strategy for high power targetry R&D between the 14 international member institutions.

Pellemoine, Frederique [Fermilab]↗

Temporal Changes in Astronauts’ Muscle and Cardiorespiratory Physiology Pre-, In-, and Post-Spaceflight

NASA’s vision for future exploration missions depends on the ability to protect astronauts’ health and safety for performance of Extravehicular Activity (EVA), and to allow astronauts to safely egress from vehicles in a variety of landing scenarios (e.g. water landing upon return to Earth and undefined planetary/lunar landings). Prolonged exposure to spaceflight results in diminished tolerance to prolonged physical activity, decreased cardiac and sensorimotor function, and loss of bone mineral density, muscle mass, and muscle strength. For over 50 years exercise has been the primary countermeasure against these physiologic decrements during spaceflight, and while the resulting protection is adequate for ISS missions (i.e., Soyuz landing, microgravity EVAs), there is little information regarding time-course changes in muscle and aerobic performance. As spaceflight progresses towards longer exploration missions and vehicles with less robust exercise capabilities compared to ISS, countermeasures will need to be combined and optimized to protect crew health and performance across all organ systems over the course of exploration missions up to 3 years in duration. This will require a more detailed understanding of the dynamic effects of spaceflight on human performance. Thus, the focus of this study is quantifying decrements in physical performance over different mission durations, and to provide detailed information on the physiological rational for “why” and “when” observed changes in performance occur. The research proposed will temporally profile changes in astronauts’ cardiorespiratory fitness, muscle mass, strength, and endurance over spaceflight missions of 2 months, 6 months, and up to 1 year in duration. Additionally, an extrapolation model will provide predictions for changes associated with exploration missions 2-3 years in duration. To accomplish these objectives astronauts will be asked to participate in pre, in, post-flight measurement of muscle performance, muscle size, cardiorespiratory fitness and submaximal performance capabilities, as well as non-invasive assessment of cerebral and muscle oxygenation and perfusion (Table 1). Additionally, ambulatory and in-flight exercise, nutrition, and sleep will be monitored using a variety of commercial technologies and in-flight assessment tools. Significance: Our detailed testing protocol will provide valuable information for describing how and when spaceflight-induced muscle and aerobic based adaptations occur over the course of spaceflight missions up to and beyond 1 year. This information will be vital in the assessment as to whether humans can be physically ready for deep space exploration such as Mars missions with current technology, or if additional mitigation strategies are necessary.

Downs, M. E.↗

ADNDT's enduring distinct role in the scientific publishing ecosystem

September 2024 marks an important anniversary for Atomic Data and Nuclear Data Tables – the 55th year since the inaugural edition in September 1969 – and prompts noting the enduring distinct service the journal has delivered, and continues to deliver, to the scientific community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

When x-rays alter the course of your experiments

The continuing increase in the brilliance of synchrotron radiation beamlines allows for many new and exciting experiments that were impossible before the present generation of synchrotron radiation sources came on line. However, the exposure to such intense beams also tests the limits of what samples can endure. Whilst the effects of radiation induced damage in a static experiment often can easily be recognized by changes in the diffraction or spectroscopy curves, the influence of radiation on chemical or physical processes, where one expects curves to change, is less often recognized and can be misinterpreted as a 'real' result instead of as a 'radiation influenced result'. This is especially a concern in time-resolved materials science experiments using techniques as powder diffraction, small angle scattering and x-ray absorption spectroscopy. In this work, the effects of radiation (5–50 keV) on some time-resolved processes in different types of materials and in different physical states are discussed. We show that such effects are not limited to soft matter and biology but rather can be found across the whole spectrum of materials research, over a large range of radiation doses and is not limited to very high brilliance beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developing Robust Ceria-Supported Catalysts for Catalytic NO Reduction and CO/Hydrocarbon Oxidation

Synthesis of robust and hydrothermally stable PGM/ceria materials for NO, CO, and hydrocarbon abatement remains a formidable challenge, as ceria and PGMs are known to sinter severely >800 °C under hydrothermal conditions, leading to irreversible activity loss. In this work, we tackle this challenge by synthesizing well-defined catalysts with atomically dispersed rhodium supported on ceria with varying abundance of (100), (101), and (111) facets. Evaluation of these catalysts for NO reduction by CO as well as CO and propylene oxidation under model and industrially relevant conditions reveals pronounced reactivity and stability differences. Different modes of interaction of Rh ions with the ceria facets and their facile reducibility were shown to be the crucial parameters controlling reactivity, resulting in pronounced activity and stability variations. Facet-dependent poisoning of surfaces by nitrites was identified as the main reason for deactivation of the catalysts at low temperature, which is mitigated for (111) ceria facets. (111)-enriched ceria nanoparticles survive very harsh hydrothermal aging at 950 °C by maintaining and preserving (111) facets, unlike other ceria nanoparticles which sinter into poorly defined shapes. Thus, putting atomically dispersed PGM sites on (111) ceria facets lead to the catalytic material with the highest activity and stability for all studied reactions, providing the pathway to catalysts that can endure extremely harsh hydrothermal aging conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exercise and neuromodulators: choline and acetylcholine in marathon runners

Certain neurotransmitters (i.e., acetylcholine, catecholamines, and serotonin) are formed from dietary constituents (i.e., choline, tyrosine and tryptophan). Changing the consumption of these precursors alters release of their respective neurotransmitter products. The neurotransmitter acetylcholine is released from the neuromuscular junction and from brain. It is formed from choline, a common constituent in fish, liver, and eggs. Choline is also incorporated into cell membranes; membranes may likewise serve as an alternative choline source for acetylcholine synthesis. In trained athletes, running a 26 km marathon reduced plasma choline by approximately 40%, from 14.1 to 8.4 uM. Changes of similar magnitude have been shown to reduce acetylcholine release from the neuromuscular junction in vivo. Thus, the reductions in plasma choline associated with strenuous exercise may reduce acetylcholine release, and could thereby affect endurance or performance.

NASA Discipline Regulatory Physiology↗

Advanced Gear Alloys for Ultra High Strength Applications

Single tooth bending fatigue (STBF) test data of UHS Ferrium C61 and C64 alloys are presented in comparison with historical test data of conventional gear steels (9310 and Pyrowear 53) with comparable statistical analysis methods. Pitting and scoring tests of C61 and C64 are works in progress. Boeing statistical analysis of STBF test data for the four gear steels (C61, C64, 9310 and Pyrowear 53) indicates that the UHS grades exhibit increases in fatigue strength in the low cycle fatigue (LCF) regime. In the high cycle fatigue (HCF) regime, the UHS steels exhibit better mean fatigue strength endurance limit behavior (particularly as compared to Pyrowear 53). However, due to considerable scatter in the UHS test data, the anticipated overall benefits of the UHS grades in bending fatigue have not been fully demonstrated. Based on all the test data and on Boeing s analysis, C61 has been selected by Boeing as the gear steel for the final ERDS demonstrator test gearboxes. In terms of potential follow-up work, detailed physics-based, micromechanical analysis and modeling of the fatigue data would allow for a better understanding of the causes of the experimental scatter, and of the transition from high-stress LCF (surface-dominated) to low-stress HCF (subsurface-dominated) fatigue failure. Additional STBF test data and failure analysis work, particularly in the HCF regime and around the endurance limit stress, could allow for better statistical confidence and could reduce the observed effects of experimental test scatter. Finally, the need for further optimization of the residual compressive stress profiles of the UHS steels (resulting from carburization and peening) is noted, particularly for the case of the higher hardness C64 material.

Shen, Tony↗

Molecular Transducers of Physical Activity Consortium (MoTrPAC): Mapping the Dynamic Responses to Exercise

Exercise provides a robust physiological stimulus that evokes cross-talk between a wide range of tissues via hormonal, cellular and molecular signals that when repeated regularly over time (i.e., training) improves physiological capacity, benefits numerous organ systems and decreases the risk for premature mortality. In spite of its fundamental importance, a gap remains in identifying the detailed molecular signals and responses to exercise and its benefits for health and disease prevention. To further knowledge in this emerging area, the Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to generate a molecular map of the effects of acute and chronic exercise. MoTrPAC investigators are conducting preclinical and clinical studies to better understand the systemic effects of exercise across multiple tissues. The preclinical studies were performed on more than 700 rats with the analysis of twenty or more organs per rat. The clinical study involves a large cohort of ~2600 individuals with a range of ages and fitness levels (untrained, trained, highly trained) who will be evaluated physiologically and by molecular probing of blood, muscle and adipose tissues before and after acute and chronic endurance or resistance exercise. Multi-omic analyses (genomics, epigenomics, transcriptomics, proteomics and metabolomics/lipidomics) will be performed followed by state-of-the-art bioinformatics to create a molecular map of exercise. This mapping project will provide a public database that is expected to enhance our understanding of the health benefits of physical activity in many organ systems and potentially provide insight into mitigating diseases through activity.

Sanford, James A.↗

Cooperative Research and Development Agreement among Ames Laboratory; NexTech Materials, Ltd. dba Nexceris; and National Energy Technology Laboratory [Abstract]

The CRADA focuses on pressurized testing of Nexceris solid oxide fuel cell (SOFC) stacks in a hybrid configuration with a recuperated gas turbine with the ultimate goal of demonstrating efficiencies in excess of 70% (LHV NG). NETL’s cyber-physical approach will be used to develop and test control strategies before installing the Nexceris SOFC stacks to maximize the chances of success. A successful test will represent a demonstration of the Nexceris stack to endure pressures associated with hybrid operation and the first public demonstration of automated hybrid SOFC/GT technology.

30 DIRECT ENERGY CONVERSION↗

Mechanisms of Hysteresis and Reversibility across the Voltage-Driven Perovskite–Brownmillerite Transformation in Electrolyte-Gated Ultrathin La 0.5 Sr 0.5 CoO 3−δ

Perovskite cobaltites have emerged as archetypes for electrochemical control of materials properties in electrolyte-gate devices. Voltage-driven redox cycling can be performed between fully oxygenated perovskite and oxygen-vacancy-ordered brownmillerite phases, enabling exceptional modulation of the crystal structure, electronic transport, thermal transport, magnetism, and optical properties. The vast majority of studies, however, have focused heavily on the perovskite and brownmillerite end points. In contrast, here we focus on hysteresis and reversibility across the entire perovskite ↔ brownmillerite topotactic transformation, combining gate-voltage hysteresis loops, minor hysteresis loops, quantitative operando synchrotron X-ray diffraction, and temperature-dependent (magneto)transport, on ion-gel-gated ultrathin (10-unit-cell) epitaxial La 0.5 Sr 0.5 CoO 3-δ films. Further, gate-voltage hysteresis loops combined with operando diffraction reveal a wealth of new mechanistic findings, including asymmetric redox kinetics due to differing oxygen diffusivities in the two phases, nonmonotonic transformation rates due to the first-order nature of the transformation, and limits on reversibility due to first-cycle structural degradation. Minor loops additionally enable the first rational design of an optimal gate-voltage cycle. Combining this knowledge, we demonstrate state-of-the-art nonvolatile cycling of electronic and magnetic properties, encompassing >10 5 transport ON/OFF ratios at room temperature, and reversible metal-insulator-metal and ferromagnet-nonferromagnet-ferromagnet cycling, all at 10-unit-cell thickness with high room-temperature stability. This paves the way for future work to establish the ultimate cycling frequency and endurance of such devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regulation of central blood volume and cardiac filling in endurance athletes: the Frank-Starling mechanism as a determinant of orthostatic tolerance

Orthostatic intolerance may result from either an abnormally large postural decrease in central blood volume, cardiac filling pressures, and stroke volume, or inadequate neurohumoral responses to orthostasis. Endurance athletes have been reported as having a high incidence of orthostatic intolerance, which has been attributed primarily to abnormalities in baroreflex regulation of heart rate and peripheral resistance. In this review, we present evidence that athletes also have structural changes in the cardiovascular system that although beneficial during exercise, lead to an excessively large decrease in stroke volume during orthostasis and contribute to orthostatic intolerance. A unifying hypothesis based on cardiac mechanics that may explain the divergence of findings in conditions such as bed rest or spaceflight, and short- and long-term endurance training is presented.

Non-NASA Center↗

LSA field test

After almost four years of endurance testing of photovoltaic modules, no fundamental life-limiting mechanisms were identified that could prevent the twenty-year life goal from being met. The endure data show a continual decline in the failure rate with each new large-scale procurement. Cracked cells and broken interconnects continue to be the principal causes of failure. Although the modules are more adversely affected physically by hot, humid environments than by cool or dry environments there are insufficient data to correlate failure with environment. There is little connection between the outward physical condition of a module and changes in its electrical performance.

Jaffe, P.↗

Exercise-training protocols for astronauts in microgravity

Based on physical working requirements for astronauts during intra- and extravehicular activity and on the findings from bed-rest studies that utilized exercise training as a countermeasure for the reduction of aerobic power, deterioration of muscular strength and endurance, decrements in mood and cognitive performance, and possibly for bone loss, two exercise protocols are proposed. One assumes that, during microgravity, astronaut exercise physiological functions should be maintained at 100 percent of ground-based levels. The other assumes that maximal aerobic power in flight can be reduced by 10 percent of the ground-based level.

Greenleaf, J. E.↗