Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polarization resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Electrochemical corrosion studies

The objective was to gain familiarity with the Model 350 Corrosion Measurement Console, to determine if metal protection by grease coatings can be measured by the polarization-resistance method, and to compare corrosion rates of 4130 steel coated with various greases. Results show that grease protection of steel may be determined electrochemically. Studies were also conducted to determine the effectiveness of certain corrosion inhibitors on aluminum and steel.

Knockemus, W. W.↗

Development of AC impedance methods for evaluating corroding metal surfaces and coatings

In an effort to investigate metal surface corrosion and the breakdown of metal protective coatings the AC Impedance Method was applied to zinc chromate primer coated 2219-T87 aluminum. The model 368-1 AC Impedance Measurement System recently acquired by the MSFC Corrosion Research Branch was used to monitor changing properties of coated aluminum disks immersed in 3.5% NaCl buffered at ph 5.5 over three to four weeks. The DC polarization resistance runs were performed on the same samples. The corrosion system can be represented by an electronic analog called an equivalent circuit that consists of transistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for resistances and capacities that can be assigned in the equivalent circuit following a least squares analysis of the data describe changes that occur on the corroding metal surface and in the protective coating. A suitable equivalent circuit was determined that predicts the correct Bode phase and magnitude for the experimental sample. The DC corrosion current density data are related to equivalent circuit element parameters.

Knockemus, Ward↗

The corrosion mechanisms for primer coated 2219-T87 aluminum

To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac Impedance Method was applied to zinc chromate primer coated 2219-T87 aluminum. The EG&GPARC Model 368 ac Impedance Measurement System, along with dc measurements with the same system using the Polarization Resistance Method, was used to monitor changing properties of coated aluminum disks immersed in 3.5 percent NaCl solutions buffered at pH 5.5 and pH 8.2 over periods of 40 days each. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for resistances and capacitances, that can be assigned in the equivalent circuit following a least squares analysis of the data, describe changes occurring on the corroding metal surface and in the protective coatings. A suitable equivalent circuit has been determined which predicts the correct Bode phase and magnitude for the experimental sample. The dc corrosion current density data are related to equivalent circuit element parameters.

Danford, Merlin D.↗

An electrochemical study of corrosion protection by primer-topcoat systems on 4130 steel with ac impedance and dc methods

To investigate metal surface corrosion and the breakdown of metal protective coatings, the ac impedance method is applied to six systems of primer coated and primer topcoated 4130 steel. Two primers were used: a zinc-rich epoxy primer and a red lead oxide epoxy primer. The epoxy-polyamine topcoat was used in four of the systems. The EG and G-PARC Model 368 ac impedance measurement system, along with dc measurements with the same system using the polarization resistance method, were used to monitor changing properties of coated 4230 steel disks immersed in 3.5 percent NaCl solutions buffered at pH 5.4 over periods of 40 to 60 days. The corrosion system can be represented by an electronic analog called an equivalent circuit consisting of resistors and capacitors in specific arrangements. This equivalent circuit parallels the impedance behavior of the corrosion system during a frequency scan. Values for the resistors and capacitors, that can be assigned in the equivalent circuit following a least-squares analysis of the data, describe changes that occur on the corroding metal surface and in the protective coatings. Two equivalent circuits have been determined that predict the correct Bode phase and magnitude of the experimental sample at different immersion times. The dc corrosion current density data are related to equivalent circuit element parameters. Methods for determining corrosion rate with ac impedance parameters are verified by the dc method.

Mendrek, M. J.↗

A comparison of chromic acid and sulfuric acid anodizing

Because of federal and state mandates restricting the use of hexavalent chromium, it was deemed worthwhile to compare the corrosion protection afforded 2219-T87 aluminum alloy by both Type I chromic acid and Type II sulfuric acid anodizing per MIL-A-8625. Corrosion measurements were made on large, flat 2219-T87 aluminum alloy sheet material with an area of 1 cm(exp 2) exposed to a corrosive medium of 3.5-percent sodium chloride at pH 5.5. Both ac electrochemical impedance spectroscopy and the dc polarization resistance techniques were employed. The results clearly indicate that the corrosion protection obtained by Type II sulfuric acid anodizing is superior, and no problems should result by substituting Type II sulfuric acid anodizing for Type I chromic acid anodizing.

Danford, M. D.↗

The corrosion protection of 2219-T87 aluminum by organic and inorganic zinc-rich primers

The behavior of zinc-rich primer-coated 2219-T87 aluminum in a 3.5-percent Na-Cl was investigated using electrochemical techniques. The alternating current (ac) method of electro-chemical impedance spectroscopy (EIS), in the frequency range of 0.001 to 40,000 Hz, and the direct current (dc) method of polarization resistance (PR) were used to evaluate the characteristics of an organic, epoxy zinc-rich primer and an inorganic, ethyl silicate zinc-rich primer. A dc electrochemical galvanic corrosion test was also used to determine the corrosion current of each zinc-rich primer anode coupled to a 2219-T87 aluminum cathode. Duration of the EIS/PR and galvanic testing was 21 days and 24 h, respectively. the galvanic test results demonstrated a very high galvanic current between the aluminum cathode and both zinc-rich primer anodes (37.9 micro A/cm(exp 2) and 23.7 micro A/cm(exp 2) for the organic and inorganic primers, respectively). The PR results demonstrated a much higher corrosion rate of the zinc in the inorganic primer than in the organic primer, due primarily to the higher porosity in the former. Based on this investigation, the inorganic zinc-rich primer appears to provide superior galvanic protection and is recommended for additional study for application in the solid rocket booster aft skirt.

Danford, M. D.↗

The corrosion protection of AISI(TM) 1010 steel by organic and inorganic zinc-rich primers

The behavior of zinc-rich primer-coated AISI 1010 steel in 3.5-percent Na-Cl was investigated using electrochemical techniques. The alternating current (ac) method of electrochemical impedance spectroscopy (EIS), in the frequency range of 0.001 to 40,000 Hz, and the direct current (dc) method of polarization resistance (PR), were used to evaluate the characteristics of an organic, epoxy zinc-rich primer and an inorganic, ethyl silicate zinc-rich primer. A dc electromechanical galvanic corrosion test was also used to determine the corrosion current of each zinc-rich primer anode coupled to a 1010 steel cathode. Duration of the EIS/PR and galvanic testing was 21 days and 24 h, respectively. The galvanic test results demonstrated a very high current between the steel cathode and both zinc-rich primer anodes (38.8 and 135.2 microns A/sq cm for the organic and inorganic primers, respectively). The results of corrosion rate determinations demonstrated a much higher corrosion rate of the zinc in the inorganic primer than in the organic primer, due primarily to the higher porosity in the former. EIS equivalent circuit parameters confirmed this conclusion. Based on this investigation, the inorganic zinc-rich primer appears to provide superior galvanic protection and is recommended for additional study for application on solid rocket booster steel hardware.

Danford, M. D.↗

Study of localized corrosion in aluminum alloys by the scanning reference electrode technique

Localized corrosion in 2219-T87 aluminum (Al) alloy, 2195 aluminum-lithium (Al-Li) alloy, and welded 2195 Al-Li alloy (4043 filler) have been investigated using the relatively new scanning reference electrode technique (SRET). Anodic sites are more frequent and of greater strength in the 2195 Al-Li alloy than in the 2219-T87 Al alloy, indicating a greater tendency toward pitting for the latter. However, the overall corrosion rates are about the same for these two alloys, as determined using the polarization resistance technique. In the welded 2195 Al-Li alloy, the weld bean is entirely cathodic, with rather strongly anodic heat affected zones (HAZ) bordering both sides, indicating a high probability of corrosion in the HAZ parallel to the weld bead.

Danford, M. D.↗

The Corrosion Protection of 2219-T87 Aluminum by Organic and Inorganic Zinc-Rich Primers

The behavior of zinc-rich primer-coated 2219-T87 aluminum in a 3.5-percent Na-Cl was investigated using electrochemical techniques. The alternating current (ac) method of electrochemical impedance spectroscopy (EIS), in the frequency range of 0.001 to 40,000 Hz, and the direct current (dc) method of polarization resistance (PR) were used to evaluate the characteristics of an organic, epoxy zinc-rich primer and an inorganic, ethyl silicate zinc-rich primer. A dc electrochemical galvanic corrosion test was also used to determine the corrosion current of each zinc-rich primer anode coupled to a 2219-T87 aluminum cathode. Duration of the EIS/PR and galvanic testing was 21 days and 24 h, respectively. The galvanic test results demonstrated a very high galvanic current between the aluminum cathode and both zinc-rich primer anodes (37.9 pA/CM2 and 23.7 pA/CM2 for the organic and inorganic primers, respectively). The PR results demonstrated a much higher corrosion rate of the zinc in the inorganic primer than in the organic primer, due primarily to the higher porosity in the former. Based on this investigation, the inorganic zinc-rich primer appears to provide superior galvanic protection and is recommended for additional study for application in the solid rocket booster aft skirt.

Danford, M. D.↗

Corrosion Studies of Wrought and Cast NASA-23 Alloy

Corrosion studies were carried out for wrought and cast NASA-23 alloy using electrochemical methods. The scanning reference electrode technique (SRET), the polarization resistance technique (PR), and the electrochemical impedance spectroscopy (EIS) were employed. These studies corroborate the findings of stress corrosion studies performed earlier, in that the material is highly resistant to corrosion.

Danford, M. D.↗

The Corrosion Protection of Magnesium Alloy AZ31B

Corrosion rates for bare and coated Magnesium alloy AZ31B have been measured. Two coatings, Dow-23(Trademark) and Tagnite(Trademark), have been tested by electrochemical methods and their effectiveness determined. Electrochemical methods employed were the scanning reference electrode technique (SRET), the polarization resistance technique (PR) and the electrochemical impedance spectroscopy technique (EIS). In addition, general corrosion and stress corrosion methods were employed to examine the effectiveness of the above coatings in 90 percent humidity. Results from these studies are presented.

Danford, M. D.↗

Corrosion Studies of 2195 Al-Li Alloy and 2219 Al Alloy with Differing Surface Treatments

Corrosion studies of 2195 Al-Li and 2219 Al alloys have been conducted using the scanning reference electrode technique (SRET) and the polarization resistance (PR) technique. The SRET was used to study corrosion mechanisms, while corrosion rate measurements were studied with the PR technique. Plates of Al203 blasted, soda blasted and conversion coated 2219 Al were coated with Deft primer and the corrosion rates studied with the EIS technique. Results from all of these studies are presented.

Danford, M. D.↗

Gadolinia-Doped Ceria Cathodes for Electrolysis of CO2

Gadolinia-doped ceria, or GDC, (Gd(0.4)Ce(0.6)O(2-delta), where the value of delta in this material varies, depending on the temperature and oxygen concentration in the atmosphere in which it is being used) has shown promise as a cathode material for high-temperature electrolysis of carbon dioxide in solid oxide electrolysis cells. The polarization resistance of a GDC electrode is significantly less than that of an otherwise equivalent electrode made of any of several other materials that are now in use or under consideration for use as cathodes for reduction of carbon dioxide. In addition, GDC shows no sign of deterioration under typical temperature and gas-mixture operating conditions of a high-temperature electrolyzer. Electrolysis of CO2 is of interest to NASA as a way of generating O2 from the CO2 in the Martian atmosphere. On Earth, a combination of electrolysis of CO2 and electrolysis of H2O might prove useful as a means of generating synthesis gas (syngas) from the exhaust gas of a coal- or natural-gas-fired power plant, thereby reducing the emission of CO2 into the atmosphere. The syngas a mixture of CO and H2 could be used as a raw material in the manufacture, via the Fisher-Tropsch process, of synthetic fuels, lubrication oils, and other hydrocarbon prod

Adler, Stuart B.↗

Characterization of Encapsulated Corrosion Inhibitors Containing Microparticles for Environmentally Friendly Smart Coatings

This poster presents the results obtained from experiments designed to evaluate the release properties, as well as the corrosion inhibition effectiveness, of several encapsulated corrosion inhibitors. Microencapsulation has been used in the development of environmentally friendly multifunctional smart coatings. This technique enables the incorporation of autonomous corrosion detection, inhibition and self-healing functionalities into many commercially available coating systems. Select environmentally friendly corrosion inhibitors were encapsulated in organic and inorganic pH-sensitive microparticles and their release in basic solutions was studied. The release rate results showed that the encapsulation can be tailored from fast, for immediate corrosion protection, to slow, which will provide continued long-term corrosion protection. The incorporation of several corrosion inhibitor release profiles into a coating provides effective corrosion protection properties. To investigate the corrosion inhibition efficiency of the encapsulated inhibitors, electrochemical techniques were used to obtain corrosion potential, polarization curve and polarization resistance data. These measurements were performed using the free as well as the encapsulated inhibitors singly or in combinations. Results from these electrochemical tests will be compared to those obtained from weight loss and other accelerated corrosion experiments.

Coatings↗

Novel Membrane-Based Corrosion Sensors For Operating In Natural Gas Pipelines

Membrane-based electrochemical sensors (MBES) provide an attractive option for real-time continuous humidity and corrosion rate measurements inside of natural gas pipelines. The MBES, can use electrochemical techniques such as linear polarization resistance and electrochemical impedance spectroscopy even when a conductive aqueous phase is intermittent or unavailable. We now present field-test performance data of our MBES operated inside a multiphase water and natural gas flow facility. The MBES measured internal corrosion and conductivity at the top, bottom, and side of the pipe spool. Tests were carried out with flow rates of 4.6, 9.1, and 18.3 m/s, temperatures of 21, 29, and 35 °C, and a pressure of 1000 psia. All sensors followed similar trends in open circuit potential, corrosion rate, and conductivity over time. Neither flow rate, temperature, nor build-up of metal-based solids on the sensor surfaces impacted the quality of the electrochemical measurements. The field-test results confirm that the membrane-based electrochemical sensors are suitable for monitoring internal corrosion of operational natural-gas pipelines.

Duffy, Timothy↗

ZnCr and ZnNb Cold Spray Coatings

Novel cold spray zinc-based alloy coatings have been investigated for corrosion protection of API 5L low carbon steel pipelines used in transporting natural gas. These different zinc alloy coatings are designed for use to help prevent internal corrosion and improve the lifespan of steel pipelines via sacrificial anodic protection. The corrosion behavior of these cold deposited zinc alloy coatings was investigated in CO2 saturated 3.5 wt.% NaCl solutions under simulated natural gas pipeline conditions. Electrochemical tests were conducted at 25 and 40 °C to determine the polarization resistance and galvanic current between each coating and the steel substrate in the galvanic couple. Tests were conducted at atmospheric, 1 bar, pressure. The results indicate that use of these coatings has the potential to increase the lifespan of steel pipelines above what a zinc coating alone could provide.

Teeter, Lucas↗

Effect of Minor Ce Additions on Corrosion Behavior of Experimental Pipeline Steel

Minor additions of rare earth elements (REEs) have been shown to improve various steel properties. In particular, Cerium (Ce), as a relatively abundant and inexpensive element, has received attention as a potentially beneficial minor alloying addition for a variety of steel applications, including pipelines materials. The objective of this work is to investigate the effect of Ce on corrosion performance of experimental high-strength pipeline steel. Electrochemical corrosion experiments were carried out on steel without and with 0.006, 0.018, and 0.03 wt.% of Ce in 3.5 wt.% NaCl saturated with CO2 at 20 oC. For comparison purposes, X100 carbon steel specimens machined from an experimental pipe with a yield strength of 731 MPa were tested under the same conditions. The electrochemical techniques employed included: potentiodynamic polarization (PDP), linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS). In addition, post-corrosion surface characterization was performed using scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS), while crystalline phases were determined by X-ray diffraction (XRD). The corrosion of base metal without Ce was lower (0.15 mm/y) compared to carbon steel X100 (0.9 mm/yr). The electrochemical results showed that adding Ce accelerates corrosion rates compared to base metal without Ce. No pitting corrosion of tested steel was detected.

Belarbi, Zineb↗

Capturing soil moisture and salinity changes in flooded coastal forests using electrical resistivity and induced polarization

Geophysical methods provide high-resolution spatial measurements of physical quantities sensitive to changes in soil moisture and salinity and can be used to monitor soil hydrological responses to flooding. However, extracting quantitative hydrological information from geophysical data remains challenging. In this study, we extended existing petrophysical models to estimate soil moisture and salinity from electrical measurements to address this challenge. We manipulated two hydrologically isolated 2000 m 2 experimental plots by simultaneously inundating them with 265 m 3 of either freshwater or estuarine water. Repeated electrical resistivity and induced polarization measurements were used to image the water and solute infiltration along two transects that are 100 and 42 m in length. Petrophysical models derived from laboratory multi-salinity electrical measurements were used to estimate changes in soil moisture and fluid salinity from field measurements of real and imaginary conductivity during the ecosystem-scale flooding experiment. The real conductivity increased by ∼100% in the freshwater plot and ∼570% in the saltwater plot. The change in imaginary conductivity in the freshwater plot was <1 mS/m, whereas that of the estuarine water plot was ∼5 mS/m. Real conductivity shows dependence on soil moisture content with a coefficient of determination (R 2 ) > 0.7, while the imaginary conductivity shows a dependence on soil salinity with R 2 > 0.6. The results validate the use of electrical resistivity for estimating changes in soil moisture content in response to flooding. Combining electrical resistivity imaging with induced polarization measurements provides the possibility to account for changes in pore fluid conductivity.

Adebayo, Moses B. [Univ. of Toledo, OH (United Sta↗