At least 91 records · Page 5

Sodium Fire Collaborative Study Progress -- CNWG Fiscal Year 2020

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year 2020. First, the current sodium pool fire model in MELCOR, which is adapted from CONTAIN-LMR code, is discussed. The associated sodium fire input requirements are also presented. These input requirements are flexible enough to permit further model development via control functions to enhance the current model without modifying the source code. The theoretical pool fire model improvement developed at Sandia is discussed. A control function model has been developed from this improvement. Then, the validation study of the sodium pool fire model in MELCOR carried out by both Sandia and JAEA’s staff is described. To validate this pool fire model with the enhancement, a JAEA sodium pool fire experiment (F7-1 test) is used. The results of the calculation are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for next fiscal year, 2021.

36 MATERIALS SCIENCE↗

Data reduction and analysis of graphite fiber release experiments

The burn and burn/explode effects on aircraft structures were examined in a series of fifteen outdoor tests conducted to verify the results obtained in previous burn and explode tests of carbon/graphite composite samples conducted in a closed chamber, and to simulate aircraft accident scenarios in which carbon/graphite fibers would be released. The primary effects that were to be investigaged in these tests were the amount and size distribution of the conductive fibers released from the composite structures, and how these various sizes of fibers transported downwind. The structures included plates, barrels, aircraft spoilers and a cockpit. The heat sources included a propane gas burner and 20 ft by 20 ft and 40 ft by 60 ft JP-5 pool fires. The larger pool fire was selected to simulate an aircraft accident incident. The passive instrumentation included sticky paper and sticky bridal veil over an area 6000 ft downwind and 3000 ft crosswind. The active instrumentation included instrumented meteorological towers, movies, infrared imaging cameras, LADAR, high voltage ball gages, light emitting diode gages, microwave gages and flame velocimeter.

Lieberman, P.↗

Validation of CONTAIN-LMR code for accident analysis of sodium-cooled fast reactor containments

CONTAIN-LMR 1 is an analytical tool for the containment performance of sodium cooled fast reactors. In this code, the modelling for the sodium fire is included: the oxygen diffusion model for the sodium pool fire, and the liquid droplet model for the sodium spray fire. CONTAIN-LMR is also able to model the interaction of liquid sodium with concrete structure. It may be applicable to different concrete compositions. Testing and validation of these models will help to qualify the simulation results. Three experiments with sodium performed in the FAUNA facility at FZK have been used for the validation of CONTAIN-LMR. For pool fire tests, calculations have been performed with two models. The first model consists of one gas cell representing the volume of the burn compartment. The volume of the second model is subdivided into 32 coupled gas cells. The agreement between calculations and experimental data is acceptable. The detailed pool fire model shows less deviation from experiments. In the spray fire, the direct heating from the sodium burning in the media is dominant. Therefore, single cell modeling is enough to describe the phenomena. Calculation results have reasonable agreement with experimental data. Limitations of the implemented spray model can cause the overestimation of predicted pressure and temperature in the cell atmosphere. The ability of the CONTAIN-LMR to simulate the sodium pool fire accompanied by sodium-concrete reactions was tested using the experimental study of sodium-concrete interactions for construction concrete as well as for shielding concrete. The model provides a reasonably good representation of chemical processes during sodium-concrete interaction. The comparison of time-temperature profiles of sodium and concrete shows, that the model requires modifications for predictions of the test results. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MELCOR/CONTAIN LMR Implementation Report - FY16 Progress.

This report describes the progress of the CONTAIN - LMR sodium physics and chemistry models to be implemented in MELCOR 2.1. In the past three years , the implementation included the addition of sodium equations of state and sodium properties from two different sources. The first source is based on the previous work done by Idaho National Laboratory by modifying MELCOR to include liquid lithium equation of state as a working fluid to model the nuclear fusion safety research. The second source uses properties generated for the SIMMER code. The implemented modeling has been tested and results are reported in this document. In addition, the CONTAIN - LMR code was derived from an early version of the CONTAIN code, and many physical models that were developed since this early version of CONTAIN are not available in this early code version. Therefore, CONTAIN 2 has been updated with the sodium models in CONTAIN - LMR as CONTAIN2 - LMR, which may be used to provide code-to-code comparison with CONTAIN - LMR and MELCOR when the sodium chemistry models from CONTAIN - LMR have been completed. Both the spray fire and pool fire chemistry routines from CONTAIN - LMR have been integrated into MELCOR 2.1, and debugging and testing are in progress. Because MELCOR only models the equation of state for liquid and gas phases of the coolant, a modeling gap still exists when dealing with experiments or accident conditions that take place when the ambient temperature is below the freezing point of sodium. An alternative method is under investigation to overcome this gap . We are no longer working on the separate branch from the main branch of MELCOR 2.1 since the major modeling of MELCOR 2.1 has been completed. At the current stage, the newly implemented sodium chemistry models will be a part of the main MELCOR release version (MELCOR 2.2). This report will discuss the accomplishments and issues relating to the implementation. Also, we will report on the planned completion of all remaining tasks in the upcoming FY2017, including the atmospheric chemistry model and sodium - concrete interaction model implementation .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sodium Fire Collaborative Study Progress (CNWG Fiscal Year 2022)

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2022 and is a continuation of the FY 2021 progress report. We only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the fraction of oxygen consumed that reacts to form monoxide (FO2) parameter in the current model from the FY2021 report. This year's enhancements relate to better agreement of the suspended aerosol measurement from JAEA's F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY 2023.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sodium Fire Collaborative Study Progress CNWG Fiscal Year 2021

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year (FY) 2021 and is a continuation of the FY2020 progress report. In this report, we only report the changes made to the current sodium pool fire model in MELCOR. We modified and corrected many control functions to enhance the current model from the FY2020 report. This year’s enhancements relate to better agreement of the suspended aerosol measurement from JAEA’s F7 series tests. Staff from Sandia and JAEA conducted the validation studies of the sodium pool fire model in MELCOR. To validate this pool fire model with the latest enhancement, JAEA sodium pool fire experiments (F7-1 and F7-2) were used. The results of the calculation, including the code-to-code comparisons are discussed as well as suggestions for further model improvement. Finally, recommendations are made for new MELCOR simulations for FY2022.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sodium Fire Collaborative Study Progress (CNWG FY 2019)

This report discusses the progress on the collaboration between Sandia National Laboratories (Sandia) and Japan Atomic Energy Agency (JAEA) on the sodium fire research in fiscal year 2019. First, the current sodium pool fire model in MELCOR, which is adapted from CONTAIN-LMR code, is discussed. The associated sodium fire input requirements are also presented. A proposed model improvement developed at Sandia is discussed. Finally, the validation study of the sodium pool fire model in MELCOR carried out by a JAEA's staff is described. To validate this model, a JAEA sodium pool fire experiment (F7-1 test) is used. A preliminary calculation is performed using a modified MELCOR model from a previous experiment simulation. The results of the calculation are discussed as well as suggestions for improvement. Finally, recommendations are made for new MELCOR simulations for next fiscal year, 2020.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fire Whirl Investigation

A series of experiments were performed with the objective of achieving an extreme thermal environment by creating a fire whirl in an enclosure in facilities at the Thermal Test Complex (TTC) at Sandia National Laboratories. The motivation for the experiments is based on results from previous experiments performed at Sandia in an igloo representing a mock weapon's storage facility. In that test series, a fire whirl developed within the igloo resulting in extremely high heat flux levels. This environment was created with a pool fire of 4.6-m in diameter and was not under controlled, repeatable conditions. The objective of the current tests is to have the ability to create this environment in a repeatable controlled environment at a smaller scale, namely with a pool fire not above 3-m diameter effectively, thereby allowing for repeatable, cost-effective testing. In FY15, six tests were conducted in the Crosswind Test Facility (XTF), using a 1.77 m square pan. In FY16, three tests were conducted in the Fire Laboratory for Accreditation of Modeling by Experiment (FLAME) using a 3-m diameter pan. Both of these test series utilized the same enclosure. In FY17, a single test was performed in XTF using a 2.7 m square pan using a modified enclosure which included a ceiling. All tests used Jet-A as the fuel. The wind speed and gap width of the enclosure were varied for the FY15 XTF tests and the gap width and effect of insulation on the enclosure walls were varied for the FY16 FLAME tests. Fuel regression rates, heat flux, and gas velocity measurements were obtained. The results from the FY15 and FY16 test series indicate that fuel regression rates and peak heat flux levels are a factor of two higher than non-fire whirl pool fires of equivalent diameter. The results from the FY17 test using an enclosure with a ceiling met the objective of the test series by achieving temperatures of nearly 1400°C and heat flux levels of 400 kW/m 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the spatial dependence of temperature and gas and soot concentrations within large open hydrocarbon fuel fires

A series of large-scale JP-4 fuel pool fire tests was conducted to refine existing mathematical models of large fires. Seven tests were conducted to make chemical concentration and temperature measurements in 7.5 and 15 meter-diameter pool fires. Measurements were made at heights of 0.7, 1.4, 2.9, 5.7, 11.4, and 21.3 meters above the fires. Temperatures were measured at up to 50 locations each second during the fires. Chemistry samples were taken at up to 23 locations within the fires and analyzed for combustion chemistry and soot concentration. Temperature and combustion chemistry profiles obtained during two 7.5 meter-diameter and two 15 meter-diameter fires are included.

Johnson, H. T.↗

Pipe Overpack Container Fire Testing: Phase II-A

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to overpressurize and release its inner content. In 2016, Phase II tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with an all-metal (NUCFIL019DS) filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. For the test phase discussed in this report, Phase II-A, the POCs are exposed to a 30-minute pool fire, with similar configurations to those tested in Phase II, except that the POC lids are fitted with a hybrid metal-polyethylene (UT9424S) filter instead. This report will: describe the various tests conducted in Phase II-A, present results from these tests, and discuss implications for the POCs based on the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pipe Overpack Container Fire Testing: Phase II-A

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to overpressurize and release its inner content. In 2016, Phase II tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with an all-metal (NUCFIL019DS) filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. For the test phase discussed in this report, Phase II-A, the POCs are exposed to a 30-minute pool fire, with similar configurations to those tested in Phase II, except that the POC lids are fitted with a hybrid metal-polyethylene (UT9424S) filter instead. This report will: describe the various tests conducted in Phase II-A, present results from these tests, and discuss implications for the POCs based on the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pipe Overpack Container Fire Testing: Phase II-B

The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire. This test resulted in one of the POCs generating sufficient internal pressure to pop off its drum lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials that would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible Transuranic (TRU) waste at Department of Energy (DOE) sites. At the request of DOE's Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), SNL started conducting a new series of fire tests in 2015 to examine whether PCs with combustibles would reach a temperature that could result in: (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner contents. In 2016, Phase II of the tests showed that POCs tested in a pool fire failed within 3 minutes of ignition with the POC lid ejecting. These POC lids were fitted with a NUCFIL-019DS filter and revealed that this specific filter did not relieve sufficient pressure to prevent lid ejection. In the Fall of 2017, Phase II-A was conducted to expose POCs to a 30-minute pool fire with similar configurations to those tested in Phase II, except that the POC lids were fitted with an UltraTech (UT) 9424S filter instead. That specific filter was chosen because of its design to help relieve internal pressure during the fire and thus prevent lid ejection. In Phase II-A, however, setups of two POCs stacked upon one another were never tested, which led to this phase of tests, Phase II-B. This report will describe the various tests conducted in Phase II-B, present results from these tests, and implications for the POCs based on the test results will be discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Metal fires and their implications for advanced reactors.

This report details the primary results of the Laboratory Directed Research and Development project (LDRD 08-0857) Metal Fires and Their Implications for Advance Reactors. Advanced reactors may employ liquid metal coolants, typically sodium, because of their many desirable qualities. This project addressed some of the significant challenges associated with the use of liquid metal coolants, primary among these being the extremely rapid oxidation (combustion) that occurs at the high operating temperatures in reactors. The project has identified a number of areas for which gaps existed in knowledge pertinent to reactor safety analyses. Experimental and analysis capabilities were developed in these areas to varying degrees. In conjunction with team participation in a DOE gap analysis panel, focus was on the oxidation of spilled sodium on thermally massive surfaces. These are spills onto surfaces that substantially cool the sodium during the oxidation process, and they are relevant because standard risk mitigation procedures seek to move spill environments into this regime through rapid draining of spilled sodium. While the spilled sodium is not quenched, the burning mode is different in that there is a transition to a smoldering mode that has not been comprehensively described previously. Prior work has described spilled sodium as a pool fire, but there is a crucial, experimentally-observed transition to a smoldering mode of oxidation. A series of experimental measurements have comprehensively described the thermal evolution of this type of sodium fire for the first time. A new physics-based model has been developed that also predicts the thermal evolution of this type of sodium fire for the first time. The model introduces smoldering oxidation through porous oxide layers to go beyond traditional pool fire analyses that have been carried out previously in order to predict experimentally observed trends. Combined, these developments add significantly to the safety analysis capabilities of the advanced-reactor community for directly relevant scenarios. Beyond the focus on the thermally-interacting and smoldering sodium pool fires, experimental and analysis capabilities for sodium spray fires have also been developed in this project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rubble Fire Multi-Phase Model Development

This report presents multi-phase modeling approaches that are developed for simulating rubble fire scenarios similar to a large-scale rubble pool fire test at Sandia National Laboratories using composite materials and jet fuel. The rubble pool fire test burnt oddly shaped combustible solid objects submerged in liquid fuel. As an intermediate step toward a full scale rubble fire simulation, various model improvement tasks were performed. For modeling solid decomposition, a multi-step degradation model was used for canonical verification problems and the Chemical Percolation for Devolatilization (CPD) approach was implemented. Capabilities of Lagrangian particle approach has been extended such that a group of particles may represent a solid bulk. For gas-liquid interface, the volume of fluid (VOF) technique was implemented and relevant physics were added. The developed tools offer a potential for simulating three-phase (gas, liquid, and solid) combustion applications.

42 ENGINEERING↗

Status of SPCA-ANL Software Development, Software Quality Assurance, and Application (FY2025)

SPCA-ANL is a simulation tool used to perform deterministic analyses of sodium spray and pool fires. Development of the SPCA-II (Spray Pool Combustion Analysis) code began in the mid- 1980s as part of the Clinch River Breeder Reactor (CRBR) Project. At that time, development of SPCA-II, which was led by Rockwell International, was focused on treatment of large-scale sodium spray, stream, and pool fires that were anticipated to be prototypic of the steam generator building cells in CRBR. Under more recent DOE NE programmatic activities, the SPCA-II code was recovered from existing literature and underwent minor modifications to generate a stable executable. This recovered version of the code was not formally released. As part of the Versatile Test Reactor (VTR) Project in the 2010s, the SPCA-II code underwent key modifications to improve stability, address modeling deficiencies, improve consistency between the code manual and software, and address numerous bugs. At this point, SPCA-II was renamed SPCA-ANL. Given that SPCA-II served as the original basis for SPCA-ANL, both codes share an integrated history. Following termination of the VTR Project, the DOE NE Fast Reactor Program resumed support of the software with the goal of building and maintaining software infrastructure that can enable commercial-grade dedication of SPCA-ANL by an end user. Version 1.0, the first external release of SPCA-ANL, was generated in June 2024. This report summarizes the development and maintenance activities completed for SPCAANL in FY2025. This year’s work was focused on improving quality and usability of the code. The provisional Software Quality Assurance (SQA) program has been established and was used to test the procedures for infrastructure improvements, code development, bug fixes, and code releases, as described in the following sections of this report. A code Version 1.0.1 was released in FY25, as described in Chapter 4.

97 MATHEMATICS AND COMPUTING↗

Potential release of fibers from burning carbon composites

A comprehensive experimental carbon fiber source program was conducted to determine the potential for the release of conductive carbon fibers from burning composites. Laboratory testing determined the relative importance of several parameters influencing the amounts of single fibers released, while large-scale aviation jet fuel pool fires provided realistic confirmation of the laboratory data. The dimensions and size distributions of fire-released carbon fibers were determined, not only for those of concern in an electrical sense, but also for those of potential interest from a health and environmental standpoint. Fire plume and chemistry studies were performed with large pool fires to provide an experimental input into an analytical modelling of simulated aircraft crash fires. A study of a high voltage spark system resulted in a promising device for the detection, counting, and sizing of electrically conductive fibers, for both active and passive modes of operation.

Bell, V. L.↗

MELCOR/CONTAIN LMR Implementation Report. FY14 Progress

This report describes the preliminary implementation of the sodium thermophysical properties and the design documentation for the sodium models of CONTAIN-LMR to be implemented into MELCOR 2.1. In the past year, the implementation included two separate sodium properties from two different sources. The first source is based on the previous work done by Idaho National Laboratory by modifying MELCOR to include liquid lithium equation of state as a working fluid to model the nuclear fusion safety research. To minimize the impact to MELCOR, the implementation of the fusion safety database (FSD) was done by utilizing the detection of the data input file as a way to invoking the FSD. The FSD methodology has been adapted currently for this work, but it may subject modification as the project continues. The second source uses properties generated for the SIMMER code. Preliminary testing and results from this implementation of sodium properties are given. In this year, the design document for the CONTAIN-LMR sodium models, such as the two condensable option, sodium spray fire, and sodium pool fire is being developed. This design document is intended to serve as a guide for the MELCOR implementation. In addition, CONTAIN-LMR code used was based on the earlier version of CONTAIN code. Many physical models that were developed since this early version of CONTAIN may not be captured by the code. Although CONTAIN 2, which represents the latest development of CONTAIN, contains some sodium specific models, which are not complete, the utilizing CONTAIN 2 with all sodium models implemented from CONTAIN-LMR as a comparison code for MELCOR should be done. This implementation should be completed in early next year, while sodium models from CONTAIN-LMR are being integrated into MELCOR. For testing, CONTAIN decks have been developed for verification and validation use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of coolant temperature on piston wall-wetting and smoke generation in a stratified-charge DISI engine operated on E30 fuel

A late-injection strategy is typically adopted in stratified-charge direct injection spark ignition (DISI) engines to improve combustion stability for lean operation, but this may induce wall wetting on the piston surface and result in high soot emissions. E30 fuel, i.e., gasoline with 30% ethanol, is a potential alternative fuel that can offer a high Research Octane Number. However, the relatively high ethanol content increases the heat of vaporization, potentially exacerbating wall-wetting issues in DISI engines. In this study, the Refractive Index Matching (RIM) technique is used to measure fuel wall films in the piston bowl. The RIM implementation uses a novel LED illumination, integrated in the piston assembly and providing side illumination of the piston-bowl window. This RIM diagnostics in combination with high-speed imaging was used to investigate the impact of coolant temperature on the characteristics of wall wetting and combustion in an optical DISI engine fueled with E30. The experiments reveal that the smoke emissions increase drastically from 0.068 FSN to 1.14 FSN when the coolant temperature is reduced from 90 °C to 45 °C. Consistent with this finding, natural flame luminosity imaging reveals elevated soot incandescence with a reduction of the coolant temperature, indicative of pool fires. Further, the RIM diagnostics show that a lower coolant temperature also leads to increased fuel film thickness, area, and volume, explaining the onset of pool fires and smoke.

42 ENGINEERING↗