Automating security monitoring and analysis for Space Station Freedom's electric power system

Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

Dolce, James L.↗

Chance-Constrained System of Systems Based Operation of Power Systems

In this paper, a chance-constrained system of systems (SoS) based decision-making approach is presented for stochastic scheduling of power systems encompassing active distribution grids. Based on the concept of SoS, the independent system operator (ISO) and distribution companies (DISCOs) are modeled as self-governing systems. These systems collaborate with each other to run the entire power system in a secure and economic manner. Each self-governing system accounts for its local reserve requirements and line flow constraints with respect to the uncertainties of load and renewable energy resources. A set of chance constraints are formulated to model the interactions between the ISO and DISCOs. The proposed model is solved by using analytical target cascading (ATC) method, a distributed optimization algorithm in which only a limited amount of information is exchanged between collaborative ISO and DISCOs. In this paper, a 6-bus and a modified IEEE 118-bus power systems are studied to show the effectiveness of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Roles of Dynamic State Estimation in Power System Modeling, Monitoring and Operation

—Power system dynamic state estimation (DSE) remains an active research area. This is driven by the absence of accurate models, the increasing availability of fast-sampled, time synchronized measurements, and the advances in the capability, scalability, and affordability of computing and communications. This paper discusses the advantages of DSE as compared to static state estimation, and the implementation differences between the two, including the measurement configuration, modeling framework and support software features. The important roles of DSE are discussed from modeling, monitoring and operation aspects for today’s synchronous machine dominated systems and the future power electronics-interfaced generation systems. Several examples are presented to demonstrate the benefits of DSE on enhancing the operational robustness and resilience of 21st century power system through time critical applications. Future research directions are identified and discussed, paving the way for developing the next generation of energy management systems.

Zhao, Junbo↗

Operation of a High Renewable Penetrated Power System With CSP Plants: A Look-Ahead Stochastic Unit Commitment Model

The integration of variable renewable energy (VRE) generation, i.e., wind power and solar photovoltaic, brings significant uncertainty for the power system operation. Different with VRE techniques, concentrating solar power (CSP) is an appealing renewable generation technology due to its dispatch ability through the use of thermal energy storage and is thus expected to play a significant role in high renewable energy penetrated power systems. In this paper, we propose a look-ahead stochastic unit commitment model to operate power systems with CSP under high renewable energy penetration. It has a three-stage structure. The first stage optimizes the operational decisions in a day-ahead framework based on forecasts; the second stage minimizes the expected generation cost for possible realizations in the real time; and the third stage accounts for look-ahead operation in future operating days. This paper has a dual purpose: first, exploring how CSP plants operate in high renewable penetrated power systems; and second, analyzing the benefits of CSP in accommodating VRE generation. A case study on a modified IEEE RTS-79 system with actual solar and wind power data is provided to validate the proposed method.

14 SOLAR ENERGY↗

Hybrid power system control and operating strategy based on power system state vector calculation

Controlling a hybrid power system includes calculating a power system state vector based on energy demand and a stored data array including a matrix defined by a power system hardware configuration. The control further includes producing a power request based on the power system state vector, and varying a flow of energy amongst energy devices using drive linkages in the hybrid power system based on the power request. Related apparatus, control logic and controller structure is disclosed.

Guo, Fang↗

Wind Power Forecasting Error Distributions: An International Comparison; Preprint

Wind power forecasting is expected to be an important enabler for greater penetration of wind power into electricity systems. Because no wind forecasting system is perfect, a thorough understanding of the errors that do occur can be critical to system operation functions, such as the setting of operating reserve levels. This paper provides an international comparison of the distribution of wind power forecasting errors from operational systems, based on real forecast data. The paper concludes with an assessment of similarities and differences between the errors observed in different locations.

17 WIND ENERGY↗

Wind Energy Management System EMS Integration Project: Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind and solar power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation), and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind/solar forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. To improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. Currently, uncertainties associated with wind and load forecasts, as well as uncertainties associated with random generator outages and unexpected disconnection of supply lines, are not taken into account in power grid operation. Thus, operators have little means to weigh the likelihood and magnitude of upcoming events of power imbalance. In this project, funded by the U.S. Department of Energy (DOE), a framework has been developed for incorporating uncertainties associated with wind and load forecast errors, unpredicted ramps, and forced generation disconnections into the energy management system (EMS) as well as generation dispatch and commitment applications. A new approach to evaluate the uncertainty ranges for the required generation performance envelope including balancing capacity, ramping capability, and ramp duration has been proposed. The approach includes three stages: forecast and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence levels. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis, incorporating all sources of uncertainties of both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures) nature. A new method called the “flying brick” technique has been developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation algorithm has been developed to validate the accuracy of the confidence intervals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Line Rating Models and Their Potential for a Cost‐Effective Transition to Carbon‐Neutral Power Systems

Most transmission system operators (TSOs) currently use seasonally steady-state models considering limiting weather conditions that serve as reference to compute the transmission capacity of overhead power lines. The use of dynamic line rating (DLR) models can avoid the construction of new lines, market splitting, false congestions, and the degradation of lines in a cost-effective way. DLR can also be used in the long run in grid extension and new power capacity planning. In the short run, it should be used to help operate power systems with congested lines. The operation of the power systems is planned to have the market trading into account; thus, it computes transactions hours ahead of real-time operation, using power flow forecasts affected by large errors. In the near future, within a “smart grid” environment, in real-time operation conditions, TSOs should be able to rapidly compute the capacity rating of overhead lines using DLR models and the most reliable weather information, forecasts, and line measurements, avoiding the current steady-state approach that, in many circumstances, assumes ampacities above the thermal limits of the lines. Here, this work presents a review of the line rating methodologies in several European countries and the United States. Furthermore, it presents the results of pilot projects and studies considering the application of DLR in overhead power lines, obtaining significant reductions in the congestion of internal networks and cross-border transmission lines.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Review of Machine Learning Applications in Power System Resilience

The integration of power electronics enabled devices and the high penetration of renewable energy drastically increase the complexity of power system operation and control. Power systems are still vulnerable to large-scale blackouts caused by extreme natural events or man-made attacks. With the recent development in artificial intelligence technique, machine learning has shown a processing ability in computational, perceptual and cognitive intelligence. It is an urgent challenge to integrate the advanced machine learning technology and large amount of real-time data from wide area measurement systems and intelligent electronic devices, in order to effectively enhance power system resilience and ensure the reliable and secure operation of power systems. Therefore, this paper aims to systematically review the existing application of machine learning methods on power system resilience enhancement, to expand the interest of researchers and scholars in this topic, and to jointly promote the application of artificial intelligence in the field of power systems.

Deep Learning↗

Evaluating the Impact of Managed EV Charging for Reliable Operation of Bulk Power Systems with High Non-Dispatchable Generation

The growth of electric vehicles (EVs) and variable-generation (VG) sources introduces new challenges for power-system operations. This study introduces a modeling framework and evaluates five EV charging strategies under projected 2040 grid conditions in the Evergy service territory with high non-dispatchable generation. Using realistic EV behavior and generation models, their impacts on system peak demand, ramp rate, and reserve capacity are evaluated. Results show that only the peak-avoidance strategy effectively reduces system peak demand, while decentralized strategies-particularly cost based dynamic charging-can exacerbate peaks due to synchronized user behavior. However, ramp-rate minimization strategy significantly reduce the stress on dispatchable generation achieving the lowest maximum absolute ramp rate (MARR) (56.81 MW) and lowest reserve requirement (2.39 GW). In contrast, unmanaged and TOU random strategies increase the stress on dispatchable generation sources with increased MARR and reserve requirements. These findings highlight the importance of coordinated, system-aware managed charging strategies to ensure reliable and affordable grid operation in the presence of EVs and VG sources.

14 - SOLAR ENERGY↗

Wind Energy Management System Integration Project Incorporating Wind Generation and Load Forecast Uncertainties into Power Grid Operations

The power system balancing process, which includes the scheduling, real time dispatch (load following) and regulation processes, is traditionally based on deterministic models. Since the conventional generation needs time to be committed and dispatched to a desired megawatt level, the scheduling and load following processes use load and wind power production forecasts to achieve future balance between the conventional generation and energy storage on the one side, and system load, intermittent resources (such as wind and solar generation) and scheduled interchange on the other side. Although in real life the forecasting procedures imply some uncertainty around the load and wind forecasts (caused by forecast errors), only their mean values are actually used in the generation dispatch and commitment procedures. Since the actual load and intermittent generation can deviate from their forecasts, it becomes increasingly unclear (especially, with the increasing penetration of renewable resources) whether the system would be actually able to meet the conventional generation requirements within the look-ahead horizon, what the additional balancing efforts would be needed as we get closer to the real time, and what additional costs would be incurred by those needs. In order to improve the system control performance characteristics, maintain system reliability, and minimize expenses related to the system balancing functions, it becomes necessary to incorporate the predicted uncertainty ranges into the scheduling, load following, and, in some extent, into the regulation processes. It is also important to address the uncertainty problem comprehensively, by including all sources of uncertainty (load, intermittent generation, generators’ forced outages, etc.) into consideration. All aspects of uncertainty such as the imbalance size (which is the same as capacity needed to mitigate the imbalance) and generation ramping requirement must be taken into account. The latter unique features make this work a significant step forward toward the objective of incorporating of wind, solar, load, and other uncertainties into power system operations. In this report, a new methodology to predict the uncertainty ranges for the required balancing capacity, ramping capability and ramp duration is presented. Uncertainties created by system load forecast errors, wind and solar forecast errors, generation forced outages are taken into account. The uncertainty ranges are evaluated for different confidence levels of having the actual generation requirements within the corresponding limits. The methodology helps to identify system balancing reserve requirement based on a desired system performance levels, identify system “breaking points”, where the generation system becomes unable to follow the generation requirement curve with the user-specified probability level, and determine the time remaining to these potential events. The approach includes three stages: statistical and actual data acquisition, statistical analysis of retrospective information, and prediction of future grid balancing requirements for specified time horizons and confidence intervals. Assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on a histogram analysis incorporating all sources of uncertainty and parameters of a continuous (wind forecast and load forecast errors) and discrete (forced generator outages and failures to start up) nature. Preliminary simulations using California Independent System Operator (California ISO) real life data have shown the effectiveness of the proposed approach. A tool developed based on the new methodology described in this report will be integrated with the California ISO systems. Contractual work is currently in place to integrate the tool with the AREVA EMS system.

17 WIND ENERGY↗

Global Power System Transformation Consortium

The Global Power System Transformation (G-PST) Consortium, an expert- and practitioner-driven initiative, engages key power system operators, research and educational institutes, governments, businesses, and stakeholders in all regions of the world to accelerate clean energy transitions at the ambitious scope and scale that is required. The G-PST Consortium provides coordinated, holistic support and knowledge infusion for system operators pursuing clean energy transitions, including performing cutting-edge research; providing implementation support for world-class engineering and operational solutions; supporting workforce development; building and disseminating open-access data and tools; and accelerating localized technology adoption, standards development, and testing programs.

consortium↗

Capturing Dynamics in the Power Grid: Formulation of Dynamic State Estimation through Data Assimilation

With the increasing complexity resulting from uncertainties and stochastic variations introduced by intermittent renewable energy sources, responsive loads, mobile consumption of plug-in vehicles, and new market designs, more and more dynamic behaviors are observed in everyday power system operation. To operate a power system efficiently and reliably, it is critical to adopt a dynamic paradigm so that effective control actions can be taken in time. The dynamic paradigm needs to include three fundamental components: dynamic state estimation; look-ahead dynamic simulation; and dynamic contingency analysis (Figure 1). These three components answer three basic questions: where the system is; where the system is going; and how secure the system is against accidents. The dynamic state estimation provides a solid cornerstone to support the other 2 components and is the focus of this study.

97 MATHEMATICS AND COMPUTING↗

A Comprehensive Comparison of Current Operating Reserve Methodologies

Electric power systems are currently experiencing a paradigm shift from a traditionally static system to a system that is becoming increasingly more dynamic and variable. Emerging technologies are forcing power system operators to adapt to their performance characteristics. These technologies, such as distributed generation and energy storage systems, have changed the traditional idea of a distribution system with power flowing in one direction into a distribution system with bidirectional flows. Variable generation, in the form of wind and solar generation, also increases the variability and uncertainty in the system. As such, power system operators are revisiting the ways in which they treat this evolving power system, namely by modifying their operating reserve methodologies. This paper intends to show an in-depth analysis on different operating reserve methodologies and investigate their impacts on power system reliability and economic efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 2: Preface: Wind Power Myths Debunked

Wind power use has grown significantly in recent years. As power system planners, investors, and other stakeholders evaluate the development of wind power plants, many questions about wind power plant operational characteristics have arisen. These questions range from asking whether wind power plants require storage, to how fast can wind power plants' output fall to zero. Recent experience in operating power systems with increasing levels of wind power, along with a significant body of analysis, has provided answers to many of these questions. In this chapter, we discuss many of these key questions and answers drawing on international experience and analysis of wind power plant operations.

17 WIND ENERGY↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales in the seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are large enough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large ({approx}50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Impact of Spatial Variation in Flexibility on System Operations in Electric Power Systems

With the expansion of renewable energy resources in the electric power systems, having flexibility in the setup will allow to maintain the system's reliability and prevailing operations. Such flexibility can be extracted from utility operated and/or consumer owned devices, such as, storage devices, electric vehicles, etc. For the demand side, generally consumer preferences, incentives, etc. enact on the availability of the flexibility; besides, both the spatial and temporal dimension dictates the degree of the flexibility. Consequently, the optimal dispatch of the grid resources might appear intractable as the considerable amount of flexibility are obliquely stemming from the ungovernable consumer devices. Thus characterizing the consequences of diverged feasible flexibility in the system is crucial for operations. In this paper, a procedure is developed to quantify the degree of flexibility of power systems in terms of resource dispatch reconfiguration. Specifically, we develop optimization problems to attain equivalent resource configurations for the power systems to evaluate the spatial volatility of the network and asses the flexibility of the system. The developed process is then validated using numerical simulations for IEEE-30 bus test system.

Sadnan, Rabayet↗