Search NASASearch

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

DPOD2020: A DORIS Extension of the ITRF2020 for Precise Orbit Determination

As one of the tracking systems used to determine orbits of the altimeter mission satellites (such as TOPEX/Poseidon, Envisat, Jason-1/-2/-3, CryoSat-2, Saral/Altika, Sentinel-3A/-3B, HY-2A/C/D, Jason-CS/Sentinel-6A, SWOT), DORIS (Doppler Orbitography Radiopositionning Integrated by Satellite) allows to determine positions and velocities of tracking stations that define a stable reference for the estimation of the precise orbits and thus are fundamental for the quality of the altimeter data and derived mean sea level products. Due to the time evolution of the DORIS ground network, some stations included in the 2020 realization of the International Terrestrial Reference Frame (ITRF2020) have been decommissioned and since 2021.0 a few new stations were added to the tracking network. Therefore, to satisfy operational requirements for POD (Precise Orbit Determination) and routine delivery of geodetic products, the International DORIS Service (IDS) regularly updates the DPOD (DORIS terrestrial reference frame for Precise Orbit Determination). The DPOD solutions include mean positions and velocities of all the DORIS stations since 1993.0 derived from the stacking of the latest IDS weekly combined series aligned to the current ITRF. In this paper, we first present the stacking process of the DPOD2020 version 1.0. Then, we address the validation procedure of the DPO2020 including comparison with ITRF2020 and POD tests. For eighty percent of all the time segments of all the DORIS stations, the station position differences between DPOD2020 version 1.0 and ITRF2020 are smaller than ten millimeters. The major position differences between these two solutions are associated with the DORIS sites either localized in the South Atlantic Anomaly region or with time spans smaller than one year. Compared to DPOD2014, the DPOD2020 shows reduction of the main statistics of the DORIS-to-DORIS tie residuals (differences between the estimated and measured ties). The POD tests showed similar results for DPOD2020 and DPOD2014 for most of the altimetric satellites (TOPEX/Poseidon, Jason-1, CryoSat-2, Jason-3). In addition, we observed better POD results with DPOD2020 for the latest altimetric satellite Sentinel-3A as well as a slight degradation for Jason-2. That degradation was fully explained by slightly worst results for the stations localized in the South Atlantic Anomaly region.

DORIS

Navigation for space shuttle approach and landing using an inertial navigation system augmented by data from a precision ranging system or a microwave scan beam landing guidance system

A preliminary study has been made of the navigation performance which might be achieved for the high cross-range space shuttle orbiter during final approach and landing by using an optimally augmented inertial navigation system. Computed navigation accuracies are presented for an on-board inertial navigation system augmented (by means of an optimal filter algorithm) with data from two different ground navigation aids; a precision ranging system and a microwave scanning beam landing guidance system. These results show that augmentation with either type of ground navigation aid is capable of providing a navigation performance at touchdown which should be adequate for the space shuttle. In addition, adequate navigation performance for space shuttle landing is obtainable from the precision ranging system even with a complete dropout of precision range measurements as much as 100 seconds before touchdown.

Mcgee, L. A.

Study of precise positioning at L-band using communications satellites

The L-band positioning experiment is reported which encompassed experiment design, experimentation, and data reduction and analysis. In the experiment the ATS-5 synchronous satellite L-band transponder was used in conjunction with the modified ALPHA 2 navigation receivers to demonstrate the technical capability of precision position fixing for oceanographic purposes. The feasibility of using relative ranging techniques implemented by two identical receiving systems, properly calibrated, to determine a line of position accurately on the surface of the earth was shown. The program demonstrated the level of resolution, repeatibility, precision, and accuracy of existing modest-cost effective navigation equipment. The experiment configuration and data reduction techniques were developed in parallel with the hardware modification tasks. Test results verify the ability of a satellite-based system to satisfy the requirements of precision position fixing.

Source record

Feedback precision and postfeedback interval duration

Precision of feedback gain was manipulated in a simple positioning task. An optimum was found; an increase in precision past that optimum produced deleterious effects upon rate of acquisition. In a second study, increasing postfeedback interval removed that optimum. The feedback precision effects were then replicated in a timing task. The combined results of the 3 studies were interpreted as supportive of an information-processing approach to the study of postfeedback interval events for simple motor skills. The findings additionally supported specific predictions by Bilodeau and deductions from Adams' 1971 theory of motor learning.

Rogers, C. A., Jr.

Low cost automated precise time measurement system

The Aerospace Guidance and Metrology Center (AGMC) has the responsibility for the dissemination of Precise Time and Time Interval (PTTI) to Air Force timing systems requiring microsecond time. In order to maintain traceability to the USNO Master Clock in Washington D.C., and accomplish efficient logging of time and frequency data on individual precision clocks, a simple automatic means of acquiring precise time has been devised. The Automatic Time Interval Measurement System (ATIMS) consists of a minicomputer (8K Memory), teletype terminal, electronic counter, Loran C receiver, time base generator and locally-manufactured relay matrix panel. During the measurement process, the computer controls the relay matrix which selects for comparison 13 atomic clocks against a reference clock and the reference versus Loran C. Through use of the system teletype, the operator is able to set the system clock (hours, minutes and seconds), examine and/or modify all clock data and constants, and set measurement intervals. This is done in a conversational manner. A logic flow diagram, system schematic, source listing and software components are included in the presentation.

Alpert, A.

Precise time and time interval (PTTI), an overview

Present applications of precise time and frequency (T/F) technology can be grouped as follows: (1) Communications systems which require T/F for time division multiplexing and for using spread spectrum techniques. (2) Navigation systems which need T/F for position fixing using a timed signal. (3) Scientific-Metrological applications which use T/F as the most precisely reproducible standard of measurement. (4) Astronomical-Space applications which cover a variety of the most demanding applications such as pulsar research, Very Long Baseline Interferometry (VLBI) and laser/radar ranging. In particular, pulsar time-of-arrival measurements require submicrosecond precision over a period of one-half year referred to an extraterrestrial inertial system, and constitute the most stringent requirements for uniform timekeeping to date.

Winkler, G. M. R.

Absolute calibration of the RADSCAT scatterometer using precision spheres

Tests using precision sphere targets suspended from balloons were conducted to calibrate the received-power/transmitted-power tatio of the RADSCAT scatterometer. Comparisons were made of these measured results with theoretical return from spheres. The RADSCAT scatterometer measurements at 13.9 GHz should be corrected by -2.4 dB, and those at 9.3 GHz, by -4.3 dB. The techniques described should be generally applicable to calibration of scatterometers where measurement precision is of prime importance. Inferred from the magnitude of these RADSCAT corrections was the present state of technology in building precision scatterometers.

Grantham, W. L.

Proceedings of the 7th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

The Proceedings contain the papers presented at the Seventh Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting and the edited record of the discussion period following each paper. This meeting provided a forum to promote more effective, efficient, economical and skillful applications of PTTI technology to the many problem areas to which PTTI offers solutions. Specifically the purpose of the meeting is to: disseminate, coordinate, and exchange practical information associated with precise time and frequency; acquaint systems engineers, technicians and managers with precise time and frequency technology and its applications; and review present and future requirements for PTTI.

Source record

The Seasat Precision Orbit Determination Experiment

The objectives and conclusions reached during the Seasat Precision Orbit Determination Experiment are discussed. It is noted that the activities of the experiment team included extensive software calibration and validation and an intense effort to validate and improve the dynamic models which describe the satellite's motion. Significant improvement in the gravitational model was obtained during the experiment, and it is pointed out that the current accuracy of the Seasat altitude ephemeris is 1.5 m rms. An altitude ephemeris for the Seasat spacecraft with an accuracy of 0.5 m rms is seen as possible with further improvements in the geopotential, atmospheric drag, and solar radiation pressure models. It is concluded that since altimetry missions with a 2-cm precision altimeter are contemplated, the precision orbit determination effort initiated under the Seasat Project must be continued and expanded.

Tapley, B. D.

Kinematic precision of gear trains

Kinematic precision is affected by errors which are the result of either intentional adjustments or accidental defects in manufacturing and assembly of gear trains. A method for the determination of kinematic precision of gear trains is described. The method is based on the exact kinematic relations for the contact point motions of the gear tooth surfaces under the influence of errors. An approximate method is also explained. Example applications of the general approximate methods are demonstrated for gear trains consisting of involute (spur and helical) gears, circular arc (Wildhaber-Novikov) gears, and spiral bevel gears. Gear noise measurements from a helicopter transmission are presented and discussed with relation to the kinematic precision theory.

Litvin, F. L.

Precision machining technology and metrology for AXAF study

The optical surfaces for the Advanced X-ray Astrophysical Facility (AXAF), was studied. The applicability of precision machining technology to the manufacture of the AXAF objective mirrors and the proposed and alternative methods for manufacturing and testing; (1) the AXAF technology mirrors and (2) the AXAF high resolution mirror assembly were reviewed. Surface shape and smoothness metrology for grazing incidence X-ray surfaces and the feasibility of applying heterodyne surface profilometry to nonflat surfaces were investigated. Three sets of scattering flats with known surface profiles and microtopographic character produced by precision machining and polished precision machine surfaces were analyzed.

Sanger, G. M.

Kinematic precision of gear trains

Kinematic precision is affected by errors which are the result of either intentional adjustments or accidental defects in manufacturing and assembly of gear trains. A method for the determination of kinematic precision of gear trains is described. The method is based on the exact kinematic relations for the contact point motions of the gear tooth surfaces under the influence of errors. An approximate method is also explained. Example applications of the general approximate methods are demonstrated for gear trains consisting of involute (spur and helical) gears, circular arc (Wildhaber-Novikov) gears, and spiral bevel gears. Gear noise measurements from a helicopter transmission are presented and discussed with relation to the kinematic precision theory. Previously announced in STAR as N82-32733

Litvin, F. L.

High precision U-PB geochronology and implications for the tectonic evolution of the Superior Province

The underlying mechanisms of Archean tectonics and the degree to which modern plate tectonic models are applicable early in Earth's history continue to be a subject of considerable debate. A precise knowledge of the timing of geological events is of the utmost importance in studying this problem. The high precision U-Pb method has been applied in recent years to rock units in many areas of the Superior Province. Most of these data have precisions of about + or - 2-3 Ma. The resulting detailed chronologies of local igneous development and the regional age relationships furnish tight constraints on any Archean tectonic model. Superior province terrains can be classified into 3 types: (1) low grade areas dominated by meta-volcanic rocks (greenstone belts); (2) high grade, largely metaplutonic areas with abundant orthogneiss and foliated to massive I-type granitoid bodies; and (3) high grade areas with abundant metasediments, paragneiss and S-type plutons. Most of the U-Pb age determinations have been done on type 1 terrains with very few having been done in type 3 terrains. A compilation of over 120 ages indicates that the major part of igneous activity took place in the period 2760-2670 Ma, known as the Kenoran event. This event was ubiquitous throughout the Superior Province.

Davis, D. W.

Results of wind simulations in the mesosphere using precision C-band radars and the inflatable falling sphere technique

The inflatable sphere technique represents a relatively inexpensive approach for obtaining density and wind data between 30 and 90 km. The procedure in its current form is adequate for operational rocket network type application. However, detailed information is lost because of oversmoothing. The present study had the objective to determine whether more detailed wind profiles could be obtained using the inflatable falling sphere and Hirobin. Hirobin is the name for the sphere reduction program used at NASA Wallops Island, VA. In connection with the aim of the study, information had to be obtained regarding the precision of the radar used to track the sphere. For this purpose, data from three C-band radars, each with a different tracking precision, were simulated. On the basis of the results of the investigation, it is concluded that, given a radar with a known precision and a perfectly performing sphere, the Hirobin filters can be adjusted to provide small-scale wind information to about 70 km.

Schmidlin, F. J.

A demonstration of high precision GPS orbit determination for geodetic applications

High precision orbit determination of Global Positioning System (GPS) satellites is a key requirement for GPS-based precise geodetic measurements and precise low-earth orbiter tracking, currently under study at JPL. Different strategies for orbit determination have been explored at JPL with data from a 1985 GPS field experiment. The most successful strategy uses multi-day arcs for orbit determination and includes fine tuning of spacecraft solar pressure coefficients and station zenith tropospheric delays using the GPS data. Average rms orbit repeatability values for 5 of the GPS satellites are 1.0, 1.2, and 1.7 m in altitude, cross-track, and down-track componenets when two independent 5-day fits are compared. Orbit predictions up to 24 hours outside the multi-day arcs agree within 4 m of independent solutions obtained with well tracked satellites in the prediction interval. Baseline repeatability improves with multi-day as compared to single-day arc orbit solutions. When tropospheric delay fluctuations are modeled with process noise, significant additional improvement in baseline repeatability is achieved. For a 246-km baseline, with 6-day arc solutions for GPS orbits, baseline repeatability is 2 parts in 100 million (0.4-0.6 cm) for east, north, and length components and 8 parts in 100 million for the vertical component. For 1314 and 1509 km baselines with the same orbits, baseline repeatability is 2 parts in 100 million for the north components (2-3 cm) and 4 parts in 100 million or better for east, length, and vertical components.

Lichten, S. M.

Apparatus Makes Precisely Saturated Solutions

Simple laboratory apparatus establishes equilibrium conditions of temperature and concentration in solutions for use in precise measurements of saturation conditions. With equipment typical measurement of saturation concentration of protein in solution established and measured within about 24 hours. Precisely saturated solution made by passing solvent or solution slowly along column packed with solute at precisely controlled temperature. If necessary, flow stopped for experimentally determined interval to allow equilibrium to be established in column.

Pusey, Marc L.

Wavelength-precise slit spectroscopy with optical fiber image scramblers

The application of optical-fiber image scramblers in wavelength-precise slit spectroscopy is discussed together with the design strategy for the optimal instrument configuration incorporating an optical-fiber image scrambler. Particular attention is given to the aspects of data analysis and interpretation techniques which must be specially designed for high-precision spectroscopy. In a specific application to an existing coude spectrograph, the instrumentation and data reduction techniques described in this paper demonstrate an achievable precision corresponding to a systematic radial velocity error of about 30 m/sec.

Heacox, William D.

A new fabrication method for precision antenna reflectors for space flight and ground test

The use of higher frequencies on communications satellites has led to the requirement for increasingly precise antenna reflectors for use in space. Typical industry fabrication methods for space antenna reflectors employ successive molding techniques for reflector face sheets and a final fit-up to a master mold in order to achieve the required accuracies. However, new missions at much higher frequencies will require greater accuracies than may be achievable using these present methods. A new approach for the fabrication of ground-test antenna reflectors is to machine the reflective surface into a stainless steel and fiberglass composite structure. A 2.7-m diameter ground-test antenna reflector fabricated using this method has an accuracy of better than 0.013 mm (0.0005 in.) rms. A similar design concept for a solid surface reflector for use on spacecraft would involve fabrication in a similar manner but using space-qualified materials. This report describes the design, analysis, and fabrication of the 2.7-m-diameter precision antenna reflector for antenna ground test and the extension of this technology to precision space antenna reflectors.

Sharp, G. Richard