Search NASA⌕ Search

SEARCH · Search NASA

Results for “Predictive Value of Tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase to phase ground and phase to ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase to ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and non-faulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/ Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

Piesciorovsky, Emilio↗

An assessment of a modified potential flow code for calculating the effect of small geometric change on the pressure and forces of supercritical airfoils

Wind-tunnel test data for two closely related supercritical airfoils were compared with calculations obtained from a nonconservative, potential flow code over a Mach number range from 0.20 to 0.80. The potential flow code includes an iterated, integral boundary-layer correction. The theoretical pressure distributions correlated more closely with the experimental pressure distributions when the flow was entirely subsonic or subsonic with a small supersonic zone than when the flow contained a large supersonic zone. The predicted drag level was below the experimental values at nearly all test conditions and the difference in drag level for the two airfoils was not accurately predicted.

Hicks, R. M.↗

Monitoring Noble Gases (Xe and Kr) and Aerosols (Cs and Rb) in a Molten Salt Reactor Surrogate Off-Gas Stream Using Laser-Induced Breakdown Spectroscopy (LIBS)

In this study with surrogate materials we show that laser-induced breakdown spectroscopy (LIBS) is a robust tool with promising capability toward monitoring gaseous (Xe and Kr) and aerosol (Cs and Rb) species in an off-gas stream from a molten salt reactor (MSR). MSRs will continually evolve fission products into the cover gas flowing across the reactor headspace. The cover gas entrains Xe and Kr gases, along with aerosol particles, before passing into an off-gas treatment system. Univariate models of Xe and Kr peaks showed a strong correlation to concentration indicated by their coefficients of determination of 0.983 and 0.997, respectively. Multivariate models were built for all four analytes using partial least squares regression coupled with preprocessing steps including normalization, trimming, and/or genetic algorithm derived filters. The models were evaluated by predicting the concentrations of the analytes in four validation samples, in which all calibration models were successfully validated at a confidence interval of 99.9%. Finally, pressure controllers were used to regulate the mass flow rate of Kr flowing into the measurement cell in sinusoidal and stepwise waveforms to test the real-time monitoring capabilities of the regression models. Both univariate and partial least squares Kr models were able to successfully quantify the gas concentration in the real-time evaluation. The root mean squared error of prediction (RMSEP) values for these real-time tests were calculated to be 0.051, 0.060, and 0.121 mol% demonstrating the measurement systems’ capability to perform online monitoring with acceptable accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Zernike test. I - Analytical aspects. II - Experimental aspects

The Zernike phenomenon is interpreted in general interferometric terms to gain insight into the optimum design of disks suitable for a particular experimental situation. The design of Zernike disks for measuring small low-order aberrations is considered and evaluated; optimum parameters for disks 2, 3, 4, and 5 microns in radius are determined for an f/12 large-space-telescope system with an obscuration ratio of 0.4 at 0.6 micron. It is shown that optimization in this case provides sensitivities of better than one hundredth of a wavelength for the measurement of low-order aberrations. The procedure for manufacturing a Zernike disk is then described in detail, and results are reported for tests of a laboratory Zernike figure sensor containing a disk manufactured according to this procedure. In the tests, a laboratory wavefront-error simulator was used to introduce small aberration ranges, measurements of the changes in reimaged pupil intensity introduced by the disk were made for several aberration settings, and the measured changes were compared with the values predicted by the interferometric theory of Zernike tests. The results are found to agree within an error of one two-hundredth of a wavelength.

Golden, L. J.↗

Spacecraft Communications System Verification Using On-Axis Near Field Measurement Techniques

Determination of the readiness of a spacecraft for launch is a critical requirement. The final assembly of all subsystems must be verified. Testing of a communications system can mostly be done using closed-circuits (cabling to/from test ports), but the final connections to the antenna require radiation tests. The Tropical Rainfall Measuring Mission (TRMM) Project used a readily available 'near-fleld on-axis' equation to predict the values to be used for comparison with those obtained in a test program. Tests were performed in a 'clean room' environment at both Goddard Space Flight Center (GSFC) and in Japan at the Tanegashima Space Center (TnSC) launch facilities. Most of the measured values agreed with the predicted values to within 0.5 dB. This demonstrates that sometimes you can use relatively simple techniques to make antenna performance measurements when use of the 'far field ranges, anechoic chambers, or precision near-field ranges' are neither available nor practical. Test data and photographs are provided.

Keating, Thomas↗

Validation of Thermal Scattering Laws for Light Water at Elevated Temperatures with Diffusion Experiments

Light water is the most important neutron moderator in many reactor applications. Thermal neutron scattering kernels for H bound in H 2 O are represented by ENDF-format thermal scattering laws (TSLs) evaluated at discrete temperatures T . Nuclear data evaluations are conventionally validated utilizing a combination of critical benchmarks and experimental cross section data. Existing public critical benchmarks may be inadequate for testing water TSLs over the full range of T of interest in reactor applications, and experimental thermal scattering cross section data for water is sparse at elevated T . In this work, MC21 is used to simulate the decay of the equilibrium thermal neutron flux in light-water spheres of several radii. The fundamental-mode time eigenvalue $\mathcal{a}$ is calculated at 22 °C and 227 °C (at saturation pressure) for each sphere using three different H-H 2 O TSLs. Fitting $\mathcal{a}$ to a polynomial function of geometric buckling allows calculation of the thermal neutron diffusion length L . Extrapolation lengths are treated as a function of the transport mean free path and geometry. Experimental L data from 25 publications at 49 temperatures (from 10 °C to 295 °C), computed by several different time-dependent and space-dependent decay methods, is used to develop an empirical fit of L vs. T . The MC21-calculated L for the TSLs tested are within ±1% of the predicted values at 22 °C and 227 °C. This validation approach, which may be repeated at arbitrary T , constitutes an integral benchmark specific to and characterizing the detailed physics of the thermal scattering kernel applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Turbopumps for cryogenic upper stage engines

Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.

Zachary, A. T.↗

Igniter adapter-to-igniter chamber deflection test

Testing was performed to determine the maximum RSRM igniter adapter-to-igniter chamber joint deflection at the crown of the inner joint primary seal. The deflection data was gathered to support igniter inner joint gasket resiliency predictions which led to launch commit criteria temperature determinations. The proximity (deflection) gage holes for the first test (Test No. 1) were incorrectly located; therefore, the test was declared a non-test. Prior to Test No. 2, test article configuration was modified with the correct proximity gage locations. Deflection data were successfully acquired during Test No. 2. However, the proximity gage deflection measurements were adversely affected by temperature increases. Deflections measured after the temperature rise at the proximity gages were considered unreliable. An analysis was performed to predict the maximum deflections based on the reliable data measured before the detectable temperature rise. Deflections to the primary seal crown location were adjusted to correspond to the time of maximum expected operating pressure (2,159 psi) to account for proximity gage bias, and to account for maximum attach and special bolt relaxation. The maximum joint deflection for the igniter inner joint at the crown of the primary seal, accounting for all significant correction factors, was 0.0031 in. (3.1 mil). Since the predicted (0.003 in.) and tested maximum deflection values were sufficiently close, the launch commit criteria was not changed as a result of this test. Data from this test should be used to determine if the igniter inner joint gasket seals are capable of maintaining sealing capability at a joint displacement of (1.4) x (0.0031 in.) = 0.00434 inches. Additional testing should be performed to increase the database on igniter deflections and address launch commit criteria temperatures.

Cook, M.↗

Orion Pad Abort 1 Crew Module Inertia Test Approach and Results

The Flight Loads Laboratory at the Dryden Flight Research Center conducted tests to measure the inertia properties of the Orion Pad Abort 1 (PA-1) Crew Module. These measurements were taken to validate analytical predictions of the inertia properties of the vehicle and assist in reducing uncertainty for derived aero performance results calculated post launch. The first test conducted was to determine the Ixx of the Crew Module. This test approach used a modified torsion pendulum test step up that allowed the suspended Crew Module to rotate about the x axis. The second test used a different approach to measure both the Iyy and Izz properties. This test used a Knife Edge fixture that allowed small rotation of the Crew Module about the y and z axes. Discussions of the techniques and equations used to accomplish each test are presented. Comparisons with the predicted values used for the final flight calculations are made. Problem areas, with explanations and recommendations where available, are addressed. Finally, an evaluation of the value and success of these techniques to measure the moments of inertia of the Crew Module is provided.

Herrera, Claudia↗

Orion Pad Abort 1 Crew Module Mass Properties Test Approach and Results

The Flight Loads Laboratory at the Dryden Flight Research Center conducted tests to measure the inertia properties of the Orion Pad Abort 1 (PA-1) Crew Module (CM). These measurements were taken to validate analytical predictions of the inertia properties of the vehicle and assist in reducing uncertainty for derived aero performance coefficients to be calculated post-launch. The first test conducted was to determine the Ixx of the Crew Module. This test approach used a modified torsion pendulum test setup that allowed the suspended Crew Module to rotate about the x axis. The second test used a different approach to measure both the Iyy and Izz properties. This test used a Knife Edge fixture that allowed small rotation of the Crew Module about the y and z axes. Discussions of the techniques and equations used to accomplish each test are presented. Comparisons with the predicted values used for the final flight calculations are made. Problem areas, with explanations and recommendations where available, are addressed. Finally, an evaluation of the value and success of these techniques to measure the moments of inertia of the Crew Module is provided.

Herrera, Claudia↗

Comparisons of AEROX computer program predictions of lift and induced drag with flight test data

The AEROX aerodynamic computer program which provides accurate predictions of induced drag and trim drag for the full angle of attack range and for Mach numbers from 0.4 to 3.0 is described. This capability is demonstrated comparing flight test data and AEROX predictions for 17 different tactical aircraft. Values of minimum (skin friction, pressure, and zero lift wave) drag coefficients and lift coefficient offset due to camber (when required) were input from the flight test data to produce total lift and drag curves. The comparisons of trimmed lift drag polars show excellent agreement between the AEROX predictions and the in flight measurements.

Axelson, J.↗

Comparison of Predicted and Measured Attenuation of Turbine Noise from a Static Engine Test

Aircraft noise has become an increasing concern for commercial airlines. Worldwide demand for quieter aircraft is increasing, making the prediction of engine noise suppression one of the most important fields of research. The Low-Pressure Turbine (LPT) can be an important noise source during the approach condition for commercial aircraft. The National Aeronautics and Space Administration (NASA), Pratt & Whitney (P&W), and Goodrich Aerostructures (Goodrich) conducted a joint program to validate a method for predicting turbine noise attenuation. The method includes noise-source estimation, acoustic treatment impedance prediction, and in-duct noise propagation analysis. Two noise propagation prediction codes, Eversman Finite Element Method (FEM) code [1] and the CDUCT-LaRC [2] code, were used in this study to compare the predicted and the measured turbine noise attenuation from a static engine test. In this paper, the test setup, test configurations and test results are detailed in Section II. A description of the input parameters, including estimated noise modal content (in terms of acoustic potential), and acoustic treatment impedance values are provided in Section III. The prediction-to-test correlation study results are illustrated and discussed in Section IV and V for the FEM and the CDUCT-LaRC codes, respectively, and a summary of the results is presented in Section VI.

Chien, Eugene W.↗

Use of Dynamically Scaled Models for Studies of the High-Angle-of-Attack Behavior of Airplanes

Dynamically scaled, free-flying models are used by the National Aeronautics and Space Administration (NASA) to study the stalling and spinning characteristics of civil and military airplane configurations. Such tests have been conducted for many different designs, and it has been possible to correlate the results predicted by the model tests with flight test results obtained in the investigations. The present paper describes four of the dynamic model testing techniques used at the NASA Langley Research Center, including the scaling laws used in the construction of models and in the interpretation of results. Predictions of stall/spin behavior based on model results have generally been very accurate, and the model tests are regarded as an invaluable precursor to full-scale flight tests. However, aerodynamic scale effects between some models and full-scale airplanes due to differences in test values of Reynolds number have resulted in erroneous predictions for a few configurations. A discussion of these effects is provided, together with the approach used to modify the model so that its behavior more closely matches that of the airplane. Finally, two typical applications of the techniques to the X-29A research airplane and several general aviation research airplanes are presented to illustrate the type of information provided by the tests.

Joseph R Chambers↗

Use of dynamically scaled models for studies of the high-angle-of-attack behavior of airplanes

Dynamically scaled, free-flying models are used by the National Aeronautics and Space Administration (NASA) to study the stalling and spinning characteristics of civil and military airplane configurations. Such tests have been conducted for many different designs, and it has been possible to correlate the results predicted by the model tests with flight test results obtained in the investigations. The present paper describes four of the dynamic model testing techniques used at the NASA Langley Research Center, including the scaling laws used in the construction of models and in the interpretation of results. Predictions of stall/spin behavior based on model results have generally been very accurate, and the model tests are regarded as an invaluable precursor to full-scale flight tests. However, aerodynamic scale effects between some models and full-scale airplanes due to differences in test values of Reynolds number have resulted in erroneous predictions for a few configurations. A discussion of these effects is provided, together with the approach used to modify the model so that its behavior more closely matches that of the airplane. Finally, two typical applications of the techniques to the X-29A research airplane and several general aviation research airplanes are presented to illustrate the type of information provided by the tests.

Joseph R Chambers↗

A Simple Test Method for Large Deformation Bending of Thin High Strain Composite Flexures

A simple test method for large deformation bending of thin composite laminates is investigated using image processing and full-field strain measurements. The assumptions and kinematic equations that represent the test are used to calculate numerically the laminate bending stiffness and strength as well as the curvature and strains at failure. In order to validate the test methodology, a comparison is performed between analytical model predictions and empirical data in terms of computed surface strains versus digital image correlation data and calculated rotation angles of the fixture arms throughout the test versus measured ones. The new test method is then used to calculate the bending stiffness in the D11 and D22 directions as well as failure strains for various thin-ply laminates of interest. These parameters are ultimately compared with predicted values using micromechanics and classical lamination theory analysis. In general, bending stiffness and strain test results and predictions for 0 degree orientation coupons have a maximum difference of 10% and 35%.

Fernandez, Juan M.↗

Multiaxial Plastic Deformation of Zircaloy-4 Nuclear Fuel Cladding Tubes

Here, this work is motivated by the desire to devise an internal pressure test that can mimic a displacement-controlled loading scenario and demonstrate how to apply the multiaxial stress and strain data from the test to develop an elastic/plastic constitutive model for a thin-walled tubular component. This is achieved by conducting simultaneous measurements of tangential and axial strain during the pressure test and integrating these strain measures into a feedback loop with the pressure controller. It is shown how data from such a test can be used to develop a large mechanical property data set relevant to biaxial loading conditions. The data obtained have high confidence evidenced by their low variability and alignment with other literature studies. Additionally, data from these internal pressure tests combined with full-tube axial tensile tests allow for the derivation of the Hill anisotropic yield function. The developed Hill yield function is validated by comparing the plastic strain ratios from the full-tube tension tests and by comparing the predicted yield stress in the tangential direction with measured values from ring tension tests in a previous study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Model-scale sound propagation experiment

The results of a scale model propagation experiment to investigate grazing propagation above a finite impedance boundary are reported. In the experiment, a 20 x 25 ft ground plane was installed in an anechoic chamber. Propagation tests were performed over the plywood surface of the ground plane and with the ground plane covered with felt, styrofoam, and fiberboard. Tests were performed with discrete tones in the frequency range of 10 to 15 kHz. The acoustic source and microphones varied in height above the test surface from flush to 6 in. Microphones were located in a linear array up to 18 ft from the source. A preliminary experiment using the same ground plane, but only testing the plywood and felt surfaces was performed. The results of this first experiment were encouraging, but data variability and repeatability were poor, particularly, for the felt surface, making comparisons with theoretical predictions difficult. In the main experiment the sound source, microphones, microphone positioning, data acquisition, quality of the anechoic chamber, and environmental control of the anechoic chamber were improved. High-quality, repeatable acoustic data were measured in the main experiment for all four test surfaces. Comparisons with predictions are good, but limited by uncertainties of the impedance values of the test surfaces.

Willshire, William L., Jr.↗