Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

FY-24 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the computational modeling of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY24. This year’s modeling campaign focuses on the continual testing of the RELAP5 model against experimental data. Several fault cases were simulated with the RELAP5 model in FY23 to study the accuracy of the model under complex flow conditions. Similarly, in FY24, a case is simulated where the chimney outlet is throttled with a valve while the flow is undergoing two-phase oscillations. The purpose of this case is to study the effects of increasing pressure drop in the two-phase region on the system behavior. Even though the model is able to capture the experimental data qualitatively, it overpredicts the pressure drops experienced by the flow in the two-phase regime. Nevertheless, the model and the experiment show that oscillations are stabilized with increased pressure drop in the two-phase region.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Acoustic Sensing to Estimate the Permeability

Optical fiber in a borehole can be interrogated with distributed acoustic sensors (DAS) to capture fracture displacements with the potential to map surrounding fracture networks. We designed a laboratory experiment to test the capability of DAS to determine borehole flow characteristics, and we show that for the first time DAS can be used to remotely estimate permeability. Optical fiber was wrapped around a bead filled pipe and the pressure drop and flow velocity were measured to directly calculate permeability. A machine learning model using statistical features from continuous DAS estimated the bulk permeability. Fluid interactions with the permeable material demonstrate insufficient resolution using DAS amplitude-based measurements for estimating pressure drop to infer permeability. Variations in the spectral domain relate DAS measurements to the pressure drop and provide consistent permeability estimates. Resolution with DAS is sufficient to estimate permeability and provides a reliable method to monitor at depth in borehole conditions.

58 GEOSCIENCES↗

High-Fidelity CFD Simulation of Mixed Convection and Forced Convection in a Pebble Bed Test Reactor Core

The Hermes low-power [35-MW(thermal)] reactor will be built and operated by Kairos Power LLC (KP) to demonstrate its fluoride salt-cooled high-temperature reactor (FHR) technology. In the KP FHR, the reactor core is composed of randomly packed pebbles with TRISO fuel particles inside with FLiBe flow upward through the core acting as a coolant. Previous numerical and experimental studies have been limited to either a small-size bed or to a lack of detailed measurements for heat transfer. Here, to address the lack of high-fidelity heat transfer data in a real-size FHR core, in this study, we simulated a pebble bed core with 34 374 pebbles randomly packed, similar to the Hermes reactor's size. The core radius was 14 times that of the pebble diameter, while the core height was 45 times. In this work, we were particularly interested in a mixed convection regime, where buoyancy is important. Therefore, we performed several large-eddy simulations at different Reynolds numbers (160 to 1000) with gravitational force included. The spectral element computational fluid dynamics code NekRS with graphics processing unit acceleration was used for this study. The low-Mach number approximation was applied to address property changes in the FLiBe and to account for buoyancy. A pure hexahedral mesh with 60 million elements was generated by the Voronoi cell method. At the polynomial order of 5, the total degrees of freedom was 7.5 billion. The developed case in this work is the first of its kind in terms of size and complexity. The local numerical data across the domain were obtained and compared with empirical correlations. After examining the data, we found the following conclusions. For pressure drop, the Reger correlation predicted less than a 5% error. On the other hand, for heat transfer, the Wakao correlation outperformed the others. Based on our findings, we recommend the use of the Wakao correlation for the Nusselt number calculation, and for pressure drop, the KTA (Kerntechnischer Ausschuss) correclation, among the available experimental correlations. In conclusion, the Reger direct numerical simulation-driven correlation for pressure drops should also be considered, given its best agreement with our calculations.

Mixed Convection↗

CFD analysis of a solid pin-fueled small modular fluoride salt-cooled reactor

A computational fluid dynamics (CFD) study is performed for the pre-conceptual solid pin-fueled small modular fluoride salt-cooled reactor developed by the Oak Ridge National Laboratory (ORNL). The solid and fluid regions in a 1/12th section of a fuel assembly are modeled. The solid region includes fuel and non-fuel pins, with heat generation in the active region of the fuel pins. Two different power profiles, uniform and center-peaked, are considered. The FLiBe coolant flows from the bottom to the top of the core, parallel to the bank of fuel and non-fuel pins. The k-ω shear-stress transport (SST) model is chosen as the baseline turbulence model. The effects of grid refinement, inlet turbulence specification, and turbulence models on the temperature and pressure drop predictions are studied. Turbulence model sensitivity is investigated by comparing the results from the k-ω SST model with other two-equation models (k-ω baseline or BSL and k-ε realizable) as well as with anisotropic Reynolds stress transport models (linear pressure-strain and stress-BSL). Here the results show that the choice of turbulence model has a significant impact on the pin temperature and bundle pressure drop predictions. The results from the baseline turbulence model show good agreement between the fuel pin temperatures and bundle pressure drop values predicted using a subchannel model previously developed by the authors of the present study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Investigation of Vapor Formation in Liquid CO2 Flow Through a Converging-Diverging Nozzle

Carbon dioxide is an attractive working fluid for many cycles, including for pumped thermal energy storage (PTES). A challenge with some proposed sCO2 PTES cycles is the operation of sCO2 machinery outside the typical bounds of experience, with local phase change from the liquid state being particularly unknown. Presently, there is insufficient data in the literature regarding multiphase CO2 to adequately design a multiphase-tolerant turbine, so generation of foundational data is required. This experimental study investigates the flow characteristics of sub-sonic liquid CO2 undergoing expansion and phase change in a converging-diverging nozzle. The nozzle is instrumented to measure static pressure, unsteady pressure, temperature, and density. The static pressure transducers are located at 27 axial locations to accurately characterize the pressure profile in the nozzle. High-accuracy RTDs are located at the entrance and exit of the nozzle, and three dynamic pressure transducers are strategically located to capture any unsteady phenomena. During testing, values of mass flow and nozzle inlet pressure are swept to vary the pressure drop and fluid properties. The measured total pressure drop in the nozzle is compared to a homogenous model and the Lockhart-Martinelli correlation method, with the latter predicting loss quite closely. The resulting data set is valuable for validating multiphase numerical models in a simple geometry before implementation of these models in turbomachinery design.

25 ENERGY STORAGE↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward full simulations for a liquid metal blanket: part 2. Computations of MHD flows with volumetric heating for a PbLi blanket prototype at Ha ~10 4 and Gr ~10 12

On the pathway toward full simulations for a liquid metal (LM) blanket, this part 2 extends a previous study of purely magnetohydrodynamic (MHD) flows in a DCLL blanket in reference Chen et al (2020 Nucl. Fusion 60 076003) to more general conditions when the MHD flow is coupled with heat transfer. The simulated prototypic blanket module includes all components of a real LM blanket system, such as supply ducts, inlet and outlet manifolds, multiple poloidal ducts and a U-turn zone. Volumetric heating generated by fusion neutrons is added to simulate thermal effects in the flowing lead–lithium (PbLi) breeder. The MHD flow equations and the energy equation are solved with a DNS-type finite-volume code ‘MHD-UCAS’ on a very fine mesh of 470 × 10 6 cells. The applied magnetic field is 5 T (Hartmann number Ha ~ 10 4 ), the PbLi velocity in the poloidal ducts is 10 cm s –1 (Reynolds number Re ~10 5 ), whereas the maximum volumetric heating is 30 MW m –3 (Grashof number Gr ~ 10 12 ). Four cases have been simulated, including forced- and mixed-convection flows, and either an electrically conducting or insulating blanket structure. Various comparisons are made between the four computed cases and also against the purely MHD flows computed earlier in reference Chen et al (2020 Nucl. Fusion 60 076003) with regards to the (1) MHD pressure drop, (2) flow balancing, (3) temperature field, (4) flows in particular blanket components, and (5) 3D and turbulent flow effects. The strongest buoyancy effects were found in the poloidal ducts. In the electrically non-conducting blanket, the buoyancy forces lead to significant modifications of the flow structure, such as formation of reverse flows, whereas their effect on the MHD pressure drop is relatively small. In the electrically conducting blanket case, the buoyancy effects on the flow and MHD pressure drop are almost negligible.

Physics↗

Formation and characterization of hydride rim structures in Zircaloy-4 nuclear fuel cladding tubes

Zirconium alloy tubes used as nuclear fuel cladding are subject to oxidation and subsequent hydrogen pickup during their long service in commercial light water reactors. The hydrogen picked up in the cladding can precipitate as a brittle hydride rim feature on the cladding outer surface. Here, to better understand the effect of hydride rims on the fracture behavior of stress-relieved zirconium alloy cladding tubes, a procedure to produce these rim-like structures has been developed and is described herein. Extensive characterization of the ‘as hydrided’ tubes is performed. The hydrogen charging apparatus consists of a tube furnace with a quartz chamber that is connected to a vacuum pump as well as a bottle of pure hydrogen gas. The charging station uses a static charge of hydrogen as opposed to a flowing gas. The chief advantage of this approach is the ability to monitor the pressure drop in the hydriding chamber and correlate this pressure drop to a known rate of hydrogen pickup in the cladding tube. It was found that the hydrogen partial pressure, metal temperature, and surface treatment all clearly played a role in whether a hydride rim was formed. Extensive characterization of the hydride rims shows they consist of needle like platelets of δ phase hydrides (ZrH1.66) oriented in the circumferential direction with a radial spacing of several microns in a sandwich-like structure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status of the LCLS-II Cryogenic Distribution System

The LINAC Coherent Light Source II (LCLS-II) located at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA, is a U.S. Department of Energy project tasked to design and build a world-class x-ray free-electron laser facility for scientific research. The Linac has superconducting radio frequency cryomodules that are connected to the cryogenic plant by the Cryogenic Distribution System (CDS), which consists of distribution boxes with heat exchangers and reliefs, feed caps, end caps, and surface, vertical, and bypass transfer lines. The CDS components were designed and built to specification by industry. The components have been delivered and their installation at SLAC will be discussed. The as-built relief system design will be presented, showing minimization of relief inlet pressure drops while meeting capacity requirements. The relieving flow pressure drops along the lengths of the CDS to centrally located reliefs at the distribution box were analysed to satisfy Pressure Vessel and Process Piping Code criteria to ensure relief performance. The sub-atmospheric 2 K circuit relieving approach will be discussed, which includes a three-way diverter isolation valve suitable for sub-atmospheric service. The component anchoring load design approach and installation into concrete floor will be discussed. This addresses loading, including seismic loading, along the component’s load path to floor anchoring system.

43 PARTICLE ACCELERATORS↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experiment and simulation of high-speed gas jet penetration into a semicircular fluidized bed

This work marks the third in a series of experiments that were in a semi-circular, gas-fluidized bed with side jets. In this work, the particles are (nominally) 1 mm ceramic beads. The bed is operated just at and slightly above and below the minimum fluidization velocity and additional fluidization is provided by two high-speed gas located on the sides of the bed near the flat, front face of the unit. Two primary measurements are taken: high-speed video recording of the front of the bed and bed pressure drop from a tap in the back of the bed. Particle Image Velocimetry (PIV) is used to determine particle motion, characterized as a mean Froude number, from the high-speed video. A CFD-DEM model of the bed is presented using the recently released MFIX-Exa code. Four model subvariants are considered using two methods of representing the jets and two drag models, both of which are calibrated to exactly match the experimentally measured minimum fluidization velocity. Although it is more difficult to determine the jet penetration depths in a straightforward manner as in the previous works using Froude number contours, the CFD-DEM results compare quite well to the PIV measurements, particularly for submodel flow Syam. Unfortunately, the good agreement of the solids-phase is overshadowed by significant disagreement in the gas-phase data. Specifically, the predicted time averaged standard deviation of the pressure drop is found to be over an order of magnitude larger than measured. Due to the low value of the measurements, just 1% of the mean bed pressure drop, it seems possible that the data is in error. On the other hand, the model may not be accurately capturing pressure attenuation through an under-fluidized region in the back of the bed. Without the possibility additional experiments to test the validity of the data, this work is simply being reported “as is” without being able to indicate which, either the simulation or the experiment, is more correct.<br>

Fullmer, William D.↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel lung-inspired 3D-printed desiccant-coated heat exchanger for high-performance humidity management in buildings

Offering an independent humidity management method for buildings, desiccant-coated heat exchangers (DCHXs) are deemed a promising approach to improve the overall energy efficiency of air conditioning (AC) systems. State-of-the-art DCHXs, however, are bound with conventional HX topologies either providing limited desiccant-air interfacial areas or introducing excessive pressure drop penalties. In this paper a novel 3D-printed DCHX concept inspired by the bronchi arrangement of a human lung is introduced to address the shortcomings inherent in existing DCHX designs. The proposed lung-inspired DCHX utilizes two intertwined bicontinuous flow networks enabling highly efficient heat and mass transfer characteristics for augmented adsorption and regeneration processes at low pressure drop penalties. While the first network evenly distributes an incoming air stream through the entire volume of the lung-inspired DCHX, the second network volumetrically splits a cooling water stream within and through the first network. Effects of various parameters including air flow rate, outdoor air humidity ratio, and regeneration temperature on dehumidification performance and energy efficiency of the proposed lung-inspired DCHX were investigated. Experimental results indicated the proposed lung-inspired 3D-printed DCHX outperforms existing DCHX systems by demonstrating an excellent balance between a high volumetric adsorption rate and a low pressure drop penalty. The volumetric adsorption rate of the proposed lung-inspired DCHX technology is 54.8 g/m 3 -s, a more than two-fold improvement compared with state-of-the-art DCHX systems. Additionally, the lung-inspired DCHX offers high thermal energy efficiency of 56% at a low regeneration temperature of 40 °C. Therefore, the proposed lung-inspired 3D-printed DCHX offers a new solid-desiccant-based air dehumidification pathway for next-generation high-performance AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Simulation of Helium Flow Loop Test Section

A helium flow loop is being assembled at Oak Ridge National Laboratory to analyze heat transfer enhancement for systems such as blanket and divertor components. To efficiently identify optimum geometries for heat transfer enhancement in these applications, simulation work is performed to optimize test section designs that are built and tested in the helium flow loop that operates at 4 MPa and a mass flow rate of 100 g/s. Different ribbed geometries that examine rib shape, rib height, rib orientation, rib spacing, and three dimensional orientation are modeled and simulated in STAR-CCM+ to compare their ability to remove heat and mitigate pressure drop. Following the simulations, models are selected and manufactured for the helium flow loop tests. Simulations initially focus on a hydrodynamic study to determine the appropriate mesh and physics models and then add a heat flux to analyze the heat transfer abilities of the models. The simulations are run in steady state and use a Reynolds-averaged Navier-Stokes k-ε turbulence model. The helium is modeled as an ideal gas. The simulation explores models of geometries that enhance the heat transfer and decrease pressure drop with an overall goal of increasing fluid collision with the wall. Enhanced geometries are simulated to select appropriate designs for manufacturing, and preliminary experimental results are used to validate the simulations. Furthermore, the factors that are being analyzed in the comparison between the experimental and the simulated results include matching thermocouple temperatures, pressure drop, roughness, and fluid velocity.

42 ENGINEERING↗