Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton Exchange Membrane Fuel Cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Regulating catalyst and ionomer interactions to promote oxygen transport in fuel cells

The cost of proton exchange membrane fuel cells (PEMFCs) has been a major impediment to their widespread commercialization. Reducing platinum (Pt) usage in PEMFC represents an essential step in lowering the cost. However, decreasing Pt loading in the cathode catalyst layer (CCL) often leads to a significant increase in the local oxygen transport resistance (R Local ), which not only slows the oxygen reduction reaction but also causes a higher polarization overpotential. The poisoning of Pt by perfluorosulfonic acid ionomers also becomes more predominant at low Pt loadings. Therefore, regulating catalyst and ionomer interactions by optimizing their interface in the CCL is crucial to improving PEMFC performance. Here, in this review, the strategies of improving oxygen transport by controlling Pt-ionomer interactions and interfaces through catalyst design, ionomer structure, and incorporation of additives are summarized. Finally, perspectives on future optimization of catalyst and ionomer interactions are proposed.

25 ENERGY STORAGE↗

Systems and methods for monitoring fuel cell membrane degradation

Systems and methods for real-time continuous monitoring of fuel cell membrane degradation are provided. At least one microsensor can be used as an inline sensor integrated at the cathode exhaust and/or the anode exhaust of a fuel cell, such as a proton exchange membrane fuel cell (PEMFC)). The microsensor can monitor the PEMFC degradation status by sensing the emission of fluoride.

Dong, Dongmei↗

Systems and methods for monitoring fuel cell membrane degradation

Systems and methods for real-time continuous monitoring of fuel cell membrane degradation are provided. At least one microsensor can be used as an inline sensor integrated at the cathode exhaust and/or the anode exhaust of a fuel cell, such as a proton exchange membrane fuel cell (PEMFC)). The microsensor can monitor the PEMFC degradation status by sensing the emission of fluoride.

Dong, Dongmei↗

PILBCP-IL Composite Ionomers for High Current Density Performance

Wide-spread commercialization of fuel cell electric vehicles using proton exchange membrane fuel cell (PEMFC) power sources requires that several existing limitations be addressed. These include: (1) a reduction in platinum (Pt) loading in the catalytic electrodes, (2) improvements in reactant and electronic mobility throughout the catalytic electrodes, (3) reduction in the reliance on materials derived from polluting “forever chemicals”, and (4) a significant improvement in the operational longevity of catalytic electrode components. In this project, a team of two universities, Drexel University and Texas A&M University, one national lab, National Renewable Energy Laboratory, and one company, General Motors, collaborated to develop a new cathode ionomer chemistry that would address these limitations and result in an improvement in performance over existing ionomer materials. The key technology developed through this collaborative project was a composite cathode ionomer encompassing an ionic liquid interlayer between Pt catalysts and a sulfonated polymerized ionic liquid block co-polymer (S-PILBCP) that possess the orthogonal properties of protonic conductivity and ionic liquid enhanced kinetics and durability (see schematic in Figure 1). The composite S-PILBCP ionomer eliminates many of the existing issues with perfluorosulfonic acid-based ionomers including active site blocking by sulfonate specific adsorption, restricted O 2 transport through ionomer films, limited humidity tolerance and active area loss for carbon pore confined catalyst particles, and use of polluting “forever chemicals”. Following successful integration of the developed composite ionic liquid into a PEMFC cathode catalyst layer, we demonstrate enhanced performance over Nafion containing cathodes with Pt/C and PtCo/C at both low and high current density. The performance with our composite S-PILBCP ionomer meets the Department of Energy (DOE) targets for light duty vehicle applications

08 HYDROGEN↗

Topological Bismuth (1 1̅ 0) Facet for Efficient Oxygen Reduction Cathode in Fuel Cells

The performance of proton-exchange membrane fuel cells is strongly dependent on the efficiency of the electrochemical oxygen reduction reaction (ORR). Here, we report both two-dimensional (4 monolayer, ML) and three-dimensional Bi (16 ML) (11̅0) facets deliver a strong correlation between nontrivial topological surface states and low electrochemical overpotential toward ORR. Both topological Bi (11̅0) film and slab have two slightly gapped (9–45 meV) Dirac cones with the invariant Z 2 =1, derived from the parity products for the occupied states at four time-reversal invariant momentum points. By contrast, the Bi (110) film is stabilized as an ordinary insulator due to atomic buckling. The much lower thermodynamic ORR overpotential (η = 0.58 V) and higher H 2 O selectivity by four steps of H + /e – transfer are obtained on the topological Bi (11̅0) surface compared with the nontopological (110) facet (η = 0.84 V). This promotional effect can be attributed to the accumulation of topological surface bands (Bi 6p orbitals) near the Fermi energy, which provide stronger electronic transport channels along the surface Bi–Bi and Bi–O bonds. Finally, a 16 ML Bi (11̅0) slab is also constructed to simulate the topological (11̅0) surface of three-dimensional bulk Bi as a topological crystalline insulator (TCI). Furthermore, the consistent topological properties and slightly lower thermodynamic ORR overpotential (η = 0.53 V) are also observed on the thicker slab.

25 ENERGY STORAGE↗

Mediated Fuel Cells: Soluble Redox Mediators and their Applications to Electrochemical Reduction of O2 and Oxidation of H2, Alcohols, Biomass, and Complex Fuels

Mediated fuel cells are electrochemical devices that produce power in a manner similar to that of conventional proton exchange membrane fuel cells (PEMFCs). They differ from PEMFCs in their use of redox mediators dissolved in liquid electrolyte to conduct oxidation of the fuel or reduction of the oxidant, typically O2, in bulk solution. The mediators transport electrons (and often protons) between the electrode and the catalysts or chemical reagents in solution. This strategy can help overcome many of the challenges associated with conventional fuel cells, including managing complex multi-phase reactions (as in O2 reduction) or the use of challenging or heterogeneous fuels, such as hydrocarbons, polyols and biomass. Mediators are also commonly used in enzymatic fuel cells, where direct electron transfer from the electrode to the enzymatic active site can be slow. This review provides a comprehensive survey of historical and recent mediated fuel cell efforts, including applications using chemical and enzymatic catalysts. Our research on in this field has been exploring a number of different topics and has been supported different funding sources: the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences (molecular mediators for catalytic oxygen reduction); the Great Lakes Bioenergy Research Center, DOE Office of Science DE-SC0018409 (research on biomass-based fuels; U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Catalysis Program, DE-FG02-05ER15690 (copper-catalyzed oxidation reactions); and the NIH NIGMS, R01 GM100143 and R35 GM134929 (use of molecular mediators for organic chemical synthesis).

Anson, Colin W.↗

Proton Conducting Sulfonated Poly(Ionic Liquid) Block Copolymers

Herein, we report the synthesis of proton-conducting sulfonated poly(ionic liquid) block copolymers (S-PILBCPs) containing one block with sulfonic acid (sulfonated styrene, SS) and the other with an IL moiety (vinylbenzylmethylimidazolium bis(trifluoromethylsulfonyl)imide, VBMIm-TFSI) using reversible addition–fragmentation chain-transfer (RAFT) polymerization and post-polymerization modifications (i.e., functionalization, anion exchange reactions, and sulfonation). The S-PILBCPs uniquely conjoin the SS block with mobile protons (H + ) and the PIL block with mobile anions (TFSI – ), where multiple highly desired properties, including high proton conductivity (from the SS block), and high IL-philicity and oxygen solubility (from the PIL block) can exist compartmentally within a microphase separated morphology (evidenced by differential scanning calorimetry (DSC) and small-angle X-ray scattering (SAXS)). High ion conductivity of 79.7 mS/cm at a PIL block composition of 21.6 mol % was observed at 80 °C and 90% relative humidity (RH) (comparable to the benchmark Nafion ionomer). This work successfully demonstrates the design of S-PILBCPs as a new material platform and showcases its promise as an ionomer for proton exchange membrane fuel cells (PEMFCs) as they simultaneously and compartmentally combine proton conductivity and oxygen solubility. Furthermore, these benefits have recently been leveraged to achieve substantial improvement in oxygen reduction reaction (ORR) activity and subsequently fuel cell performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Nanoparticle Degradation in Hydrogen Fuel Cell Systems through Automated Electron Microscopy

Proton exchange membrane fuel cells (PEMFC) are promising devices for the deployment of hydrogen-powered heavy-duty vehicles, providing a higher efficiency for similar driving range and fueling time than the existing ones. However, PEMFCs still encounter durability challenges mainly due to catalyst degradation in the cathode. Mitigating these performance losses requires a better understanding of the degradation mechanisms under heavy-duty accelerated stress tests (ASTs) [1]. Scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray spectroscopy (EDS) are key tools for the analysis of Pt and PtCo nanoparticle size, spatial distribution and composition [2]. Electron tomography is also used to determine the rate and type of degradation of catalyst nanoparticles as a function of their position on the carbon support. In this work, automated data acquisition software, paired with a custom Python code, have been used to study the effect of different accelerated stress tests (ASTs) on nanoparticle coarsening [2]. Figure 1 shows high-angle annular dark-field (HAADF)-STEM images and EDS maps comparing the cathodes of membrane electrode assemblies (MEAs) following an electrocatalyst AST performed under H2/N2 with that of the heavy-duty AST performed under H2/air. We will discuss how AST conditions affect considerably the spatial distribution of the nanoparticles across the electrode between the membrane and microporous layer. Although the median particle size increased more in the MEA aged under the heavy-duty AST, as determined using a high-throughput image analysis, the quantitative EDS measurements demonstrate that the electrocatalyst AST resulted in more Pt and Co dissolution from the cathode, which is another important indicator of electrocatalyst degradation. We will further present the impact of the relative humidity (% RH) on the degradation mechanisms demonstrated using the same approach. Electron tomography has been used to distinguish the Pt nanoparticles residing on the carbon support surface (exterior) from those within the pore structure (interior) in order to determine the relative stability of interior and exterior nanoparticles. As shown in Figure 2, we will compare the Pt catalyst particle size at the beginning of test (BOT) and end of test (EOT), and discuss the importance of automating the electron tomography workflow, i.e. acquisition, reconstruction, and visualization, to increase sampling and determine the standard deviation of these measurement. The outlook for utilizing low-dose cryo-tomography for limiting damage to the catalyst, support, and especially proton-conducting ionomer will also be discussed [3].

Amichi, Lynda↗

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗

Blended conventional and high oxygen permeability ionomers as a fuel cell electrode binder

Ionomer strongly influences the performance of proton exchange membrane fuel cells (PEMFCs), affecting catalyst activity and reactant transport within the electrodes. While recent work on high oxygen permeability ionomers (HOPI) has demonstrated improved performance compared to conventional perfluorosulfonic acid (PFSA) ionomers such as Nafion™, there have also been reports of increased cracking in fabricated electrodes. We investigated the effects of blending HOPI with Nafion™ ionomer dispersions when fabricating cathode catalyst layers (CCLs). Small-angle x-ray scattering suggests that the ionomers mix well, and adsorption measurements indicate that HOPI adsorbs less strongly to the carbon-supported platinum (Pt) catalyst, and in blends, the Nafion™ ionomer exhibits a greater degree of adsorption. Imaging CCLs revealed a decrease in crack formation in blended samples as HOPI content decreased, with 14% HOPI having the lowest crack density. In a membrane electrode assembly (MEA) using a high surface area carbon support, the 14% HOPI blend exhibited similar performance to 100% HOPI. However, similar performance enhancements were not achieved with a medium surface area carbon support. These findings suggest a path for low-crack CCLs with enhanced oxygen transport, while highlighting a need for further investigation of ionomer blending towards efficient and durable PEMFCs.

25 ENERGY STORAGE↗

Recreating Fuel Cell Catalyst Degradation in Aqueous Environments for Identical-Location Scanning Transmission Electron Microscopy Studies

The recent surge in interest of proton exchange membrane fuel cells (PEMFCs) for heavy-duty vehicles increases the demand on the durability of oxygen reduction reaction electrocatalysts used in the fuel cell cathode. This prioritizes efforts aimed at understanding and subsequently controlling catalyst degradation. Identical-location scanning transmission electron microscopy (IL-STEM) is a powerful method that enables precise characterization of degradation processes in individual catalyst nanoparticles across various stages of cycling. Recreating the degradation processes that occur in PEMFC membrane electrode assemblies (MEAs) within the aqueous cell used for IL-STEM experiments is vital for generating an accurate understanding of these processes. In this work, we investigate the type and degree of catalyst degradation achieved by cycling in an aqueous cell compared to a PEMFC MEA. While significant degradation is observed in IL-STEM experiments performed on a traditional Pt catalyst using the standard accelerated stress test potential window (0.6-0.95 VRHE), degradation of a PtCo catalyst designed for heavy-duty vehicle use is very limited compared to that observed in MEAs. We therefore explore various experimental parameters such as temperature, acid type, acid concentration, ionomer content, and potential window to identify conditions that reproduce the degradation observed in MEAs. We find that by extending the cycling potential window to 0.4-1.0 V RHE in an electrolyte containing Pt ions, the degraded particle size distribution and alloy composition better match that observed in MEAs. In particular, these conditions increase the relative contribution of Ostwald ripening, which appears to play a more significant role in the degradation of larger alloy particles supported on high-surface-area carbons than coalescence. Results from this work highlight the potential for discrepancies between ex situ aqueous experiments and MEA tests. While different catalysts may require a unique modification to the AST protocol, strategies provided in this work enable future in situ and identical-location experiments that will play an important role in the development of robust catalysts for heavy-duty vehicle applications.

30 DIRECT ENERGY CONVERSION↗

Final Technical Report for project entitled Highly Active, Durable, and Ultra-Low PGM NSTF Thin Film ORR Catalysts and Support

In this project, the objective was to develop new oxygen reduction reaction (ORR) electrocatalysts for proton exchange membrane fuel cells (PEMFCs) which could exceed all of the Department of Energy (DOE) 2020 targets listed in DE-FOA-0001224, Subtopic 1b, Table I. The expected outcome was development of one or more electrocatalysts which are substantially improved over the current state-of-the-art in terms of overall activity, durability, and cost, and are suitable for automotive traction and stationary fuel cell applications. This report summarizes this project’s progress towards meeting the stated objectives and includes a summary of key findings and conclusions. The development activities towards new highly active and durable thin film electrocatalysts has led to the discovery of several electrocatalysts which approached or exceeded several DOE 2020 targets for activity, durability, and performance in proton exchange membrane fuel cell (membrane electrode assemblies (MEAs). In this project, electrocatalyst development focused on systematic physical and electrochemical characterization of electrocatalyst activity, durability, and performance in MEAs as a function of electrocatalyst fabrication, compositional and structural variables. The project approach was to develop relationships between the catalyst functional responses (activity, durability and performance) with catalyst physical properties and catalyst fabrication methods. Additionally, the thin film catalysts were integrated onto the unique and durable 3M Nanostructured Thin Film (NSTF) support, consisting of arrays of self-assembled organic crystalline whiskers. The catalysts were evaluated against the project targets via extensive electrochemical characterization in MEA format at 3M, advanced structural and compositional microscopy at Oak Ridge National Laboratory (ORNL), and atomic structure analysis via XAFS at Argonne National Laboratory (ANL). The extensive electrochemical and physical characterization resulted in development of several trends which correlate the catalysts’ electrochemical properties to their physical properties, including composition, structure, and method of fabrication. The development was guided by density functional theory (DFT) modeling at Purdue University and kinetic Monte Carlo (kMC) modeling at Johns Hopkins University. The catalyst simulations provided key insights into the observed experimental activity and durability trends, and additionally were utilized to assess new electrocatalyst concepts prior to or coincident with physical catalyst development. This development has led to several electrocatalyst candidates with activity and durability which approach or exceed DOE targets. One class of catalysts, based on nm-scale thin layers of Pt on Ir, met or exceeded 6 of the 6 DOE targets the project addressed.

08 HYDROGEN↗

Migration and Precipitation of Platinum in Anion‐Exchange Membrane Fuel Cells

Abstract Despite the recent progress in increasing the power generation of Anion‐exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X‐ray micro‐computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X‐ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt +2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo−N−C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

Raut, Aniket↗

Migration and Precipitation of Platinum in Anion–Exchange Membrane Fuel Cells

Despite the recent progress in increasing the power generation of Anion-exchange membrane fuel cells (AEMFCs), their durability is still far lower than that of Proton exchange membrane fuel cells (PEMFCs). Using the complementary techniques of X-ray micro-computed tomography (CT), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray (EDX) spectroscopy, we have identified Pt ion migration as an important factor to explain the decay in performance of AEMFCs. In alkaline media Pt+2 ions are easily formed which then either undergo dissolution into the carbon support or migrate to the membrane. In contrast to PEMFCs, where hydrogen cross over reduces the ions forming a vertical “Pt line” within the membrane, the ions in the AEM are trapped by charged groups within the membrane, leading to disintegration of the membrane and failure. Furthermore, diffusion of the metal components is still observed when the Pt/C of the cathode is substituted with a FeCo–N–C catalyst, but in this case the Fe and Co ions are not trapped within the membrane, but rather migrate into the anode, thereby increasing the stability of the membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eliminating dissolution of platinum-based electrocatalysts at the atomic scale

Deployment of proton-exchange membrane fuel cells is limited by the durability of Pt-nanoscale catalysts during cathodic oxygen reduction reactions. Dissolution processes on single crystalline and thin film surfaces are now correlated leading to the design of PtAu catalysts with suppressed dissolution. A remaining challenge for the deployment of proton-exchange membrane fuel cells is the limited durability of platinum (Pt) nanoscale materials that operate at high voltages during the cathodic oxygen reduction reaction. In this work, atomic-scale insight into well-defined single-crystalline, thin-film and nanoscale surfaces exposed Pt dissolution trends that governed the design and synthesis of durable materials. A newly defined metric, intrinsic dissolution, is essential to understanding the correlation between the measured Pt loss, surface structure, size and ratio of Pt nanoparticles in a carbon (C) support. It was found that the utilization of a gold (Au) underlayer promotes ordering of Pt surface atoms towards a (111) structure, whereas Au on the surface selectively protects low-coordinated Pt sites. Finally, this mitigation strategy was applied towards 3 nm Pt 3 Au/C nanoparticles and resulted in the elimination of Pt dissolution in the liquid electrolyte, which included a 30-fold durability improvement versus 3 nm Pt/C over an extended potential range up to 1.2 V.

36 MATERIALS SCIENCE↗

Study of Cathode Gas Diffusion Architecture for Improved Oxygen Transport in Hydroxide Exchange Membrane Fuel Cells

The high pH environment in hydroxide exchange membrane fuel cells (HEMFCs) has the potential to reach lower costs than the current proton exchange membrane fuel cells (PEMFCs), the incumbent technology. A significant difference between HEMFCs and PEMFCs is the location of water production within the cell. In PEMFCs, the water is produced on the cathode, limiting oxygen transport. In HEMFCs, the water is produced on the anode where the fuel is pure hydrogen. This allows the cathode to be optimized for oxygen transport without the presence of excess liquid water. Limiting current analysis, a technique previously used in PEMFCs, is adopted in HEMFCs to evaluate the oxygen mass transport resistances for different sections of the cathode. Through elimination of the microporous layer (MPL), gas diffusion layer (GDL), and traditional flow field and using porous nickel foam for gas distribution, the transport resistance at an operating condition of 150 kPa(g) and with the cell temperature at 80 °C was decreased from 112 s m −1 to 48 s m −1 , effectively halved. The optimal configuration for performance was found with Ni foam and a GDL, eliminating the MPL and traditional flow field, which vastly improved oxygen transport while maintaining adequate electrical contact with the cathode catalyst layer.

25 ENERGY STORAGE↗

Microscopy Studies of the Catalyst Inks for PEM Fuel Cells

The microstructure of the catalyst layer in proton exchange membrane fuel cells (PEMFC) is one of the key factors that determine fuel cell performance. The ink preparation, including dispersion solvent, mixing time, and mixing power, are among the less reported parameters that would influence the ionomer distribution on the catalyst surface and the continuity of the carbon network. In this work, novel characterization approaches have been used to investigate the effect of the Pt/C catalyst ink preparation conditions on the morphology and structures of the catalyst layer. Microscopy analysis revealed that longer mixing time led to better performing electrode structures than shorter mixing time. The longer mixing time enabled improved continuity of the ionomer network and high porosity in the cathode layer that contributes to improved proton conductivity and mass transport. This has been reflected in performance and durability tests, where the electrode made from a 5-day catalyst ink displayed improved performance compared to the one made from a 3-day ink. Durability studies showed 26% and 43% loss of the initial mass activity for 5 days and 3 days mixing, respectively. Finally, in addition, the catalyst layer prepared with ethylene glycol as the dispersion solvent showed better durability than water/1-propanol based solution.

25 ENERGY STORAGE↗