Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The EPIC-MOS Particle-Induced Background Spectra

In order to analyse diffuse emission that fills the field of view, one must accurately characterize the instrumental backgrounds. For the XMM-Newton EPIC instrument these backgrounds include a temporally variable "quiescent" component. as well as the strongly variable soft proton contamination. We have characterized the spectral and spatial response of the EPIC detectors to these background components and have developed tools to remove these backgrounds from observations. The "quiescent" component was characterized using a combination of the filter-wheel-closed data and a database of unexposed-region data. The soft proton contamination was characterized by differencing images and spectra taken during flared and flare-free intervals. After application of our modeled backgrounds, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear spectral evidence of solar wind charge exchange emission. Using a large sample of blank sky data, we show that strong magnetospheric SWCX emission requires elevated solar wind fluxes; observations through the densest part of the magnetosheath are not necessarily strongly contaminated with SWCX emission.

Kuntz, K. D.↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Summary of Quantitative Interpretation of Image Far Ultraviolet Auroral Data

Direct imaging of the magnetosphere by instruments on the IMAGE spacecraft is supplemented by simultaneous observations of the global aurora in three far ultraviolet (FUV) wavelength bands. The purpose of the multi-wavelength imaging is to study the global auroral particle and energy input from thc magnetosphere into the atmosphere. This paper describes provides the method for quantitative interpretation of FUV measurements. The Wide-Band Imaging Camera (WIC) provides broad band ultraviolet images of the aurora with maximum spatial and temporal resolution by imaging the nitrogen lines and bands between 140 and 180 nm wavelength. The Spectrographic Imager (SI), a dual wavelength monochromatic instrument, images both Doppler-shifted Lyman alpha emissions produced by precipitating protons, in the SI-12 channel and OI 135.6 nm emissions in the SI-13 channel. From the SI-12 Doppler shifted Lyman alpha images it is possible to obtain the precipitating proton flux provided assumptions are made regarding the mean energy of the protons. Knowledge of the proton (flux and energy) component allows the calculation of the contribution produced by protons in the WIC and SI-13 instruments. Comparison of the corrected WIC and SI-13 signals provides a measure of the electron mean energy, which can then be used to determine the electron energy fluxun-. To accomplish this reliable modeling emission modeling and instrument calibrations are required. In-flight calibration using early-type stars was used to validate the pre-flight laboratory calibrations and determine long-term trends in sensitivity. In general, very reasonable agreement is found between in-situ measurements and remote quantitative determinations.

Frey, H. U.↗

Structural Changes to the Gd‐DTPA Complex at Varying Ligand Protonation State

Abstract Diethylenetriaminepentaacetic acid (DTPA) is a chelating agent whose complex with the Gd 3+ ion is used in medical imaging. DTPA is also used in lanthanide‐actinide separation processes. As protonation of the DTPA ligand can facilitate dissociation of the Gd 3+ ion from the Gd‐DTPA complex, this work investigates the coordination structures of the aqueous Gd 3+ ion and its environment when chelated by DTPA in eight different DTPA protonation states. Both classical and ab initio molecular dynamics (MD) simulations are conducted to model the solvated complexes. Extended X‐ray absorption fine structure (EXAFS) measurements of the Gd 3+ aqua ion, and the Gd‐DTPA complex at pH 1 and 11, are compared to EXAFS spectra predicted from the MD simulations to verify the accuracy of the MD structures. The findings of this work provide atomic‐level details into the fluctuating Gd‐DTPA complex environment as the DTPA ligand gradually detaches from the Gd 3+ ion with increased protonation.

Chemistry↗

Proton deflectometry with in situ x-ray reference for absolute measurement of electromagnetic fields in high-energy-density plasmas

In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

47 OTHER INSTRUMENTATION↗

A Mars Pathfinder landing on a recently drained ephemeral sea: Cerberus Plains, 6 deg N, 188 deg W

Along a 500 km-wide belt extending between 202 deg and 180 deg W and lying astride the martian equator, moderately low-albedo, uncratered smooth plains exhibit low thermal inertia and potentially favorable conditions for the preservation of near-surface ice. The Cerberus Plains occupy a topographic trough as much as 2 km below the planetary datum, and the denser atmosphere at these altitudes would also favor long residence times for near-surface ice once emplaced. The plains have previously been interpreted as the result of young (late Amazonian) low viscosity lava flows or similarly youthful fluvial deposition. However, the plains are also included in maps of possibly extensive martian paleoseas or paleolakes. Ice emplaced as such seas dissipated could still be preserved under thin (a few tens of centimeters) sedimentary cover. In any case, and if a sea once existed, aqueous-born interstitial cementation, probably including hydrated iron oxides and sulfate minerals, would have been favored and is now susceptible to investigation by the Pathfinder alpha proton x-ray spectrometer and multispectral imager.

Brakenridge, G. Robert↗

Search for a heavy composite Majorana neutrino in events with dilepton signatures from proton-proton collisions at s = 13 TeV

Results are presented of a search for a heavy Majorana neutrino Image 1 decaying into two same-flavor leptons ℓ (electrons or muons) and a quark-pair jet. A model is considered in which the Image 1 is an excited neutrino in a compositeness scenario. The analysis is performed using a sample of proton-proton collisions at s = 13 TeV recorded by the CMS experiment at the CERN LHC, corresponding to an integrated luminosity of 138 fb − 1 . The data are found to be in agreement with the standard model prediction. For the process in which the Image 1 is produced in association with a lepton, followed by the decay of the Image 1 to a same-flavor lepton and a quark pair, an upper limit at 95% confidence level on the product of the cross section and branching fraction is obtained as a function of the Image 1 mass Image 2 and the compositeness scale Λ. For this model the data exclude the existence of Image 3 (Image 4) for Image 2 below 6.0 (6.1) TeV, at the limit where Image 2 is equal to Λ. For Image 5, values of Λ less than 20 (23) TeV are excluded. These results represent a considerable improvement in sensitivity, covering a larger parameter space than previous searches in Image 6 collisions at 13 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plasma Distribution in Mercury's Magnetosphere Derived from MESSENGER Magnetometer and Fast Imaging Plasma Spectrometer Observations

We assess the statistical spatial distribution of plasma in Mercury's magnetosphere from observations of magnetic pressure deficits and plasma characteristics by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. The statistical distributions of proton flux and pressure were derived from 10months of Fast Imaging Plasma Spectrometer (FIPS) observations obtained during the orbital phase of the MESSENGER mission. The Magnetometer-derived pressure distributions compare favorably with those deduced from the FIPS observations at locations where depressions in the magnetic field associated with the presence of enhanced plasma pressures are discernible in the Magnetometer data. The magnitudes of the magnetic pressure deficit and the plasma pressure agree on average, although the two measures of plasma pressure may deviate for individual events by as much as a factor of approximately 3. The FIPS distributions provide better statistics in regions where the plasma is more tenuous and reveal an enhanced plasma population near the magnetopause flanks resulting from direct entry of magnetosheath plasma into the low-latitude boundary layer of the magnetosphere. The plasma observations also exhibit a pronounced north-south asymmetry on the nightside, with markedly lower fluxes at low altitudes in the northern hemisphere than at higher altitudes in the south on the same field line. This asymmetry is consistent with particle loss to the southern hemisphere surface during bounce motion in Mercury's offset dipole magnetic field.

magnetic↗

Displacement Damage Induced Dark Current and Random Telegraph Signal in P-Type Deep-Trench Pinned Photogates

This study focuses on displacement damage induced dark current and Random Telegraph Signal (RTS) in STMicroelectronics P-Type photogate, a device moving away from the 4T Pinned-Photodiode, with a sensitive volume exclusively made of boron-doped P-type epitaxy, and collecting holes instead of electrons. Results show a typical trend for the shape of dark current and RTS degradation in CMOS Image Sensors with the exception that the measured generation rates seem 2 times smaller than typical literature values in irradiated silicon. Different hypothesis on the origin of this discrepancy are explored.

displacement damage dose↗

High-resolution ultra-low field magnetic resonance imaging with a high-sensitivity sensing coil

We present high-resolution magnetic resonance imaging (MRI) at ultra-low field (ULF) with a proton Larmor frequency of around 120 kHz. The key element is a specially designed high-sensitivity sensing coil in the shape of a solenoid with a few millimeter gap between windings to decrease the proximity effect and, hence, increase the coil’s quality ([Formula: see text]) factor and sensitivity. External noise is strongly suppressed by enclosing the sensing coil in a copper cylindrical shield, large enough not to negatively affect the coil’s [Formula: see text] factor and sensitivity, measured to be 217 and 0.47 fT/Hz[Formula: see text], respectively. To enhance small polarization of proton spins at ULF, a strong pulsed 0.1 T prepolarization field is applied, making the signal-to-noise ratio (SNR) of ULF MRI sufficient for high-quality imaging in a short time. We demonstrate ULF MRI of a copper sulfate solution phantom with a resolution of [Formula: see text] and SNR of 10. The acquisition time is 6.3 min without averaging. The sensing coil size in the current realization can accommodate imaging objects of 9 cm in size, sufficient for hand, and it can be further increased for human head imaging in the future. Since the in-plane resolution of [Formula: see text] is typical in anatomical medical imaging, this ULF MRI method can be an alternative low-cost, rapid, portable method for anatomical medical imaging of the human body or animals. This ULF MRI method can supplement other MRI methods, especially when such methods are restricted due to high cost, portability requirement, imaging artifacts, and other factors.

59 BASIC BIOLOGICAL SCIENCES↗

A study of the sensitivity of an imaging telescope (GRITS) for high energy gamma-ray astronomy

When a gamma-ray telescope is placed in Earth orbit, it is bombarded by a flux of cosmic protons much greater than the flux of interesting gammas. These protons can interact in the telescope's thermal shielding to produce detectable gamma rays, most of which are vetoed. Since the proton flux is so high, the unvetoed gamma rays constitute a significant background relative to some weak sources. This background increases the observing time required to pinpoint some sources and entirely obscures other sources. Although recent telescopes have been designed to minimize this background, its strength and spectral characteristics were not previously calculated in detail. Monte Carlo calculations are presented which characterize the strength, spectrum and other features of the cosmic proton background using FLUKA, a hadronic cascade program. Several gamma-ray telescopes, including SAS-2, EGRET and the Gamma Ray Imaging Telescope System (GRITS), are analyzed, and their proton-induced backgrounds are characterized. In all cases, the backgrounds are either shown to be low relative to interesting signals or suggestions are made which would reduce the background sufficiently to leave the telescope unimpaired. In addition, several limiting cases are examined for comparison to previous estimates and calibration measurements.

Yearian, Mason R.↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delivering Robust Proton-Only Sensing of Hyperpolarized [1,2- 13 C 2 ]-Pyruvate Using Broad-Spectral-Range Nuclear Magnetic Resonance Pulse Sequences

Hyperpolarized [1- 13 C]pyruvate is the leading hyperpolarized injectable contrast agent and is currently under evaluation in clinical trials for molecular imaging of metabolic diseases, including cardiovascular disease and cancer. One aspect limiting broad scalability of the technique is that hyperpolarized 13 C MRI requires specialized 13 C hardware and software that are not generally available on clinical MRI scanners, which employ proton-only detection. Here, we present an approach that uses pulse sequences to transfer 13 C hyperpolarization to methyl protons for detection of the 13 C– 13 C pyruvate singlet, employing proton-only excitation and detection only. The new pulse sequences are robust to the B 1 and B 0 magnetic field inhomogeneities. The work focuses on singlet-to-magnetization (S2M) and rotor-synchronized (R) pulses, both relying on trains of hard pulses with broad spectral width coverage designed to effectively transform hyperpolarized 13 C 2 -singlet hyperpolarization to 1 H polarization on the CH 3 group of [1,2- 13 C 2 ]pyruvate. Finally, this approach may enable a broader adoption of hyperpolarized MRI as a molecular imaging technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anisotropic neutron response of trans-stilbene and impact on a handheld dual particle imager

Here this manuscript details measurements of the anisotropic light-output response of trans-stilbene, henceforth referred to as stilbene, along the three primary crystal planes and analyzes how this anisotropic response impacts neutron image reconstruction in a handheld dual particle imager (H2DPI). A prototype H2DPI composed of stilbene pillars (6 x 6 x 50 mm 3 ) coupled to silicon photomultipliers was built and is capable of imaging both fast neutrons and gamma rays from kilogram quantities of special nuclear material. Stilbene was chosen as the scintillating medium for the imager because of its pulse shape discrimination capability, time resolution and relatively high light output. A drawback to using stilbene, however, is the anisotropic response. A recoiling proton from a neutron elastic-scattering event in stilbene will yield different amounts of scintillation light depending on the direction of the recoiling proton with respect to the crystal lattice. This manuscript analyzes how this anisotropic response impacts neutron image reconstruction in 4π. The light output in the three primary crystal planes of stilbene were independently measured 6–7 times for proton recoil energies ranging from 0.5–5.0 MeV using a quasi-monoenergetic time-of-flight neutron source. The measured light-output data in the three crystal planes were fit with a semi-empirical function based on Birks’ formula. These fits were used to reconstruct the location of a 252 Cf source in front of the imager (0°, -0.8°), to the left of the imager (-90°, -0.8°) and directly above the imager (0°, 90°) to determine if it is necessary to apply the directionally-dependent response of stilbene to accurately reconstruct source locations. A bootstrapping technique was applied to the measured data sets to produce 1000 images composed of 2000 cone projections for each source location and each measured light-output curve. List-mode maximum likelihood expectation maximization was applied to each image; the highest pixel location and the full width at half maximum (FWHM) were then recorded. The average and standard deviations of these parameters were taken for each set of images. The maximum difference in the average azimuthal pixel location when varying between the appropriate and incorrect light-output curves for the source locations at (0°, -0.8°) and (-90°, -0.8°) were respectively found to be 1.85 ± 1.39° and 2.03 ± 1.78°. All other pixel locations and FWHMs were within a single standard deviation of uncertainty. Taken together, the anisotropic response of stilbene has negligible impact on the neutron image reconstruction capability of the H2DPI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the polarizations of prompt and non-prompt J/ψ and ψ ( 2S ) mesons produced in pp collisions at s = 13 TeV

The polarizations of prompt and non-prompt Image 2 and ψ ( 2S ) mesons are measured in proton-proton collisions at s = 13 TeV, using data samples collected by the CMS experiment in 2017 and 2018, corresponding to a total integrated luminosity of 103.3 fb − 1 . Based on the analysis of the dimuon decay angular distributions in the helicity frame, the polar anisotropy, λ ϑ , is measured as a function of the transverse momentum, p T , of the charmonium states, in the 25–120 and 20–100 GeV ranges for the Image 2 and ψ ( 2S ) , respectively. The non-prompt polarizations agree with predictions based on the hypothesis that, for p T ≳ 25 GeV , the non-prompt Image 2 and ψ ( 2S ) are predominantly produced in two-body B meson decays. The prompt results clearly exclude strong transverse polarizations, even for p T exceeding 30 times the Image 2 mass, where λ ϑ tends to an asymptotic value around 0.3. Taken together with previous measurements, by CMS and LHCb at s = 7 TeV, the prompt polarizations show a significant variation with p T , at low p T .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation and experimental study of proton bunch self-modulation in plasma with linear density gradients

We present numerical simulations and experimental results of the self-modulation of a long proton bunch in a plasma with linear density gradients along the beam path. Simulation results agree with the experimental results reported [F. Braunmller, T. Nechaeva et al. (AWAKE Collaboration), Phys. Rev. Lett. 125, 264801 (2020)]: with negative gradients, the charge of the modulated bunch is lower than with positive gradients. In addition, the bunch modulation frequency varies with gradient. Simulation results show that dephasing of the wakefields with respect to the relativistic protons along the plasma is the main cause for the loss of charge. The study of the modulation frequency reveals details about the evolution of the self-modulation process along the plasma. In particular for negative gradients, the modulation frequency across time-resolved images of the bunch indicates the position along the plasma where protons leave the wakefields. Simulations and experimental results are in excellent agreement.

43 PARTICLE ACCELERATORS↗