Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proton imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the Deeply Virtual Neutral Pion Electroproduction Cross Section off the Proton at 10.6 GeV using the CLAS12 Detector

Deeply virtual exclusive reactions provide unique channels to study both transverse and longitudinal properties of the nucleon simultaneously, allowing for a 3D image of nucleon substructure. This presentation will discuss work towards extracting an absolute cross section for one such exclusive process, deeply virtual neutral pion production, using 10.6 GeV electron scattering data off a proton target from the CLAS12 experiment in Jefferson Lab Hall B. This measurement is important as exclusive meson production has unique access to the chiral odd Generalized Parton Distributions, and is also a background for other exclusive processes such as Deeply Virtual Compton Scattering, making the determination of this cross section crucial for other exclusive analyses.

Johnston, Robert↗

From quantitative trait loci towards mechanisms: Linkage Integration Hypothesis Testing (LIgHT) sheds light on the mechanisms of genetically modulated stress tolerance

The goal of this work is to assess the mechanistic bases of natural genetic variations in plant responses of photosynthesis to stress. To achieve this goal, we devised the Linkage Integration Hypothesis Testing (LIgHT) approach, comparing chromosomal locations of quantitative trait loci (QTLs) for multiple phenotypes to distinguish between hypothetical mechanisms. As a use case, we explored genetic variations in photosynthesis-related processes under chilling stress in recombinant inbred lines of cowpea ( Vigna unguiculata L. Walp.). We focused on photosynthesis-related parameters measurable in high throughput and indicative of proposed chilling responses, including the states of PSI and PSII, photoprotective non-photochemical quenching, PSII photodamage, and nyctinastic leaf movements (NLMs). The patterns of QTL linkages indicated that chilling stress tolerance is genetically controlled by avoiding PSII photodamage rather than PSI damage or NLMs. This model was validated in a separate experiment measuring the rates of PSII photodamage and repair. Additional linkages suggest that chilling-induced damage to PSII is controlled by the thylakoid proton motive force and redox state of PSII. This regulation appears to be modulated by thylakoid fatty acid composition, previously associated with the same genetic loci and now supported by broader mechanistic evidence. We propose that the LIgHT approach can be broadly applied to test mechanisms underlying genetic variations.

MultispeQ↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Point cloud-based diffusion models for the Electron-Ion Collider

At high-energy collider experiments, generative models can be used for a wide range of tasks, including fast detector simulations, unfolding, searches of physics beyond the Standard Model, and inference tasks. In particular, it has been demonstrated that score-based diffusion models can generate high-fidelity and accurate samples of jets or collider events. This work expands on previous generative models in three distinct ways. First, our model is trained to generate entire collider events, including all particle species with complete kinematic information. We quantify how well the model learns event-wide constraints such as the conservation of momentum and discrete quantum numbers. We focus on the events at the future Electron-Ion Collider, but we expect that our results can be extended to proton-proton and heavy-ion collisions. Second, previous generative models often relied on image-based techniques. The sparsity of the data can negatively affect the fidelity and sampling time of the model. We address these issues using point clouds and a novel architecture combining edge creation with transformer modules called Point Edge Transformers. Third, we adapt the foundation model OmniLearn, to generate full collider events. This approach may indicate a transition toward adapting and fine-tuning foundation models for downstream tasks instead of training new models from scratch.

Araz, Jack Y. [Stony Brook Univ., NY (United State↗

Analysis of the automatic reconstruction of protons from simulated neutrino interactions in the ICARUS detector: study of the performance of track vs shower discrimination algorithms

ICARUS, Imaging Cosmic and Rare Underground Signals, is the far detector of the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). This program was born with the purpose of definitely explaining some anomalies in the field of neutrino oscillation physics, that can suggest the existence of a 4-type of neutrino: the sterile neutrino. It doesn’t interact directly with ordinary matter through the weak interaction, but we can observed the effect of its oscillation. In this chapter I will briefly observe: • the physics goals of the SBN Program; • the role of ICARUS as SBN far detector; • the detection technology.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy

The general concept of radiation therapy used in conventional cancer treatment is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and radiation beams that deliver a radiation dose with high conformality, e.g., protons and ions. However, the treatment and cure are still limited by normal tissue radiation toxicity, with the corresponding side effects. A fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged recently, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high-dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. While dose delivery conditions to achieve a FLASH effect are not yet fully characterized, it is currently estimated that doses delivered in less than 200 ms produce normal-tissue-sparing effects, yet effectively kill tumor cells. Despite a great opportunity, there are many technical challenges for the accelerator community to create the required dose rates with novel compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proton radiography inversions with source extraction and comparison to mesh methods

In this article, proton radiography is a central diagnostic technique for measuring electromagnetic (EM) fields in high-energy-density, laser-produced plasmas. In this technique, protons traverse the plasma where they accumulate small EM deflections which lead to variations in the proton fluence pattern on a detector. Path-integrated EM fields can then be extracted from the fluence image through an inversion process. In this work, experiments of laser-driven foils were conducted on the OMEGA laser and magnetic field reconstructions were performed using both “fluence-based” techniques and high-fidelity “mesh-based” methods. We implement nonzero boundary conditions into the inversion and show their importance by comparing against mesh measurements. Good agreement between the methods is found only when nonzero boundary conditions are used. We also introduce an approach to determine the unperturbed proton source profile, which is a required input in fluence reconstruction algorithms. In this approach, a fluence inversion is embedded inside of a mesh region, which provides overconstrained magnetic boundary conditions. A source profile is then iteratively optimized to satisfy the boundary information. This method substantially enhances the accuracy in recovering EM fields. Lastly, we propose a scheme to quantify uncertainty in the final inversion that is introduced through errors in the source retrieval.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Deeply Virtual Compton Scattering Cross Section from the Proton at 10.6 GeV using the CLAS12 Detector

Deeply Virtual Compton Scattering (DVCS) is an exclusive process that produces a real photon when a lepton scatters from a quark inside a nucleon or a nucleus. Measurement of the DVCS cross section enables the study of the Generalized Parton Distributions (GPD), which plays a central role in understanding the QCD dynamics inside a hadron. Thus, the quark and gluon origin of the nucleon spin and mass can be probed and three-dimensional images of the target nucleon or nucleus can be realized. This thesis presents a cross section analysis of DVCS from the proton in the presence of its background, Bethe-Heitler (BH) process. The CEBAF Large Acceptance Spectrometer for operation at 12 GeV beam energy (CLAS12) collaboration has taken electron-proton scattering data in fall 2018 using a liquid hydrogen target and the 10.6 GeV polarized electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF). The CLAS12 detector is a nearly hermetic fixed-target detector, located in Hall B, Jefferson Lab at Newport News, Virginia. The experimentally determined BH-DVCS cross section is in good agreement with a phenomenological-model based theoretical prediction. The kinematic dependence of the cross section is reported over a wide range. The short-term plan to utilize the results presented here for a thorough tomography study and the long-term plan for GPD studies at future facilities such as the Electron-Ion Collider (EIC) are discussed.

Lee, Sangbaek↗

Gain characterization of LGAD sensors with beta particles and 28-MeV protons

Low Gain Avalanche Diodes, also known as LGADs, are widely considered for fast-timing applications in high energy physics, nuclear physics, space science, medical imaging, and precision measurements of rare processes. Such devices are silicon-based and feature an intrinsic gain due to a p + -doped layer that allows the production of a controlled avalanche of carriers, with multiplication on the order of 10–100. This technology can provide time resolution on the order of 20–30 ps, and variants of this technology can provide precision tracking too. The characterization of LGAD performance has so far primarily been focused on the interaction of minimum ionizing particles for high energy and nuclear physics applications. This article expands the study of LGAD performance to highly-ionizing particles, such as 28-MeV protons, which are relevant for several future scientific applications, e.g. in biology and medical physics, among others. These studies were performed with a beam of 28-MeV protons from a tandem Van de Graaff accelerator at Brookhaven National Laboratory and beta particles from a ^90Sr source; these were used to characterize the response and the gain of an LGAD as a function of bias voltage and collected charge. Here, the experimental results are also compared to TCAD simulations.

47 OTHER INSTRUMENTATION↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗