Search NASA⌕ Search

SEARCH · Search NASA

Results for “Proximity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Closed-Form Approximation of the Total Variation Proximal Operator

Total variation (TV) is a widely used function for regularizing imaging inverse problems that is particularly appropriate for images whose underlying structure is piecewise constant. TV regularized optimization problems are typically solved using proximal methods, but the way in which they are applied is constrained by the absence of a closed-form expression for the proximal operator of the TV function. A closed-form approximation of the TV proximal operator has previously been proposed, but its accuracy was not theoretically explored in detail. Here, we address this gap by making several new theoretical contributions, proving that the approximation leads to a proximal operator of some convex function, it is equivalent to a gradient descent step on a smoothed version of TV, and that its error can be fully characterized and controlled with its scaling parameter. We experimentally validate our theoretical results on image denoising and sparse-view computed tomography (CT) image reconstruction.

97 MATHEMATICS AND COMPUTING↗

The Thermal Proximity Effect: A New Probe of the He ii Reionization History and Quasar Lifetime

Despite decades of effort, the timing and duration of He ii reionization and the properties of the quasars believed to drive it are still not well constrained. We present a new method to study both via the thermal proximity effect—the heating of the intergalactic medium (IGM) around quasars when their radiation doubly ionizes helium. We post-process hydrodynamical simulations with 1D radiative transfer and study how the thermal proximity effect depends on the He ii fraction, x{sub HeII,0}, which prevailed in the IGM before the quasar turned on, and the quasar lifetime t{sub Q}. We find that the amplitude of the temperature boost in the quasar environment depends on x{sub HeII,0}, with a characteristic value of ΔT≃10{sup 4} K for x{sub HeII,0}=1.0, whereas the size of the thermal proximity zone is sensitive to t{sub Q}, with typical sizes of ≃100 cMpc for t{sub Q}=10{sup 8} yr. This temperature boost increases the thermal broadening of H i absorption lines near the quasar. We introduce a new Bayesian statistical method based on measuring the Lyα forest power spectrum as a function of distance from the quasar, and demonstrate that the thermal proximity effect should be easily detectable. For a mock data set of 50 quasars at z≃4, we predict that one can measure x{sub HeII,0} to an (absolute) precision ≈0.04 and t{sub Q} to a precision of ≈0.1 dex. By applying our formalism to existing high-resolution Lyα forest spectra, one should be able to reconstruct the He ii reionization history, providing a global census of hard photons in the high-z universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Versus Distal Splenic Artery Embolisation for Blunt Splenic Trauma: What is the Impact on Splenic Immune Function?

PurposeTo compare the impact of proximal or distal splenic artery embolisation versus that of splenectomy on splenic immune function as measured by IgM memory B cell levels.Materials and MethodsPatients with splenic trauma who were treated by splenic artery embolisation (SAE) were enrolled. After 6 months splenic volume was assessed by CT, and IgM memory B cells in peripheral blood were measured and compared to a local normal reference population and to a post-splenectomy population.ResultsOf the 71 patients who underwent embolisation, 38 underwent proximal embolisation, 11 underwent distal embolisation, 22 patients were excluded, 1 had both proximal and distal embolisation, 5 did not survive and 16 did not return for evaluation. There was a significant difference between splenectomy and proximal or distal embolisation and a trend towards greater preservation of IgM memory B cell number in those with distal embolisation—a difference that could not be attributed to differences in age, grade of injury or residual splenic volume.ConclusionIgM memory B cell levels are significantly higher in those treated with SAE compared to splenectomy. Our data provide evidence that splenic embolisation should reduce immunological complications of spleen trauma and suggest that distal embolisation may maintain better function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin and Proximity Effects in Electrodes and Furnace Shells

A review of two-dimensional (2D) analytical models of skin and proximity effects in large industrial furnaces with three electrodes arranged in an equilateral triangle is given. The models cover three different cases: one electrode only, three electrodes where two are approximated by line currents, and induced shell currents where all electrodes are approximated by line currents. The first two models show how the skin and proximity effects depend on electrode material properties and size, and the distance between the electrodes. The third model shows how the strength of the induced shell currents will depend on electrode position and furnace size. These models are compared to numerical studies including distributed electrodes and shell currents. The analytical models are accurate when induced shell currents can be disregarded. However, strong shell currents may have a significant impact on the current distribution within the electrodes. This electrode-shell proximity effect competes with the electrode-electrode proximity effect. Finally, the 2D models have been compared with three-dimensional (3D) case studies of large industrial furnaces. In 3D, the shell currents are significantly smaller than what are predicted by the 2D models, but they are sufficiently strong to cause a significant correction of the electrode current density.

36 MATERIALS SCIENCE↗

Predicting the proximity to macroscopic failure using local strain populations from dynamic in situ X-ray tomography triaxial compression experiments on rocks

Predicting the proximity of large-scale dynamic failure is a critical concern in the engineering and geophysical sciences. Here we use evolving contractive, dilatational, and shear strain deformation preceding failure in dynamic X-ray tomography experiments to examine which strain components best predict the proximity to failure. We develop machine learning models to predict the proximity to failure using time series of three-dimensional local incremental strain tensor fields acquired in rock deformation experiments under stress conditions of the upper crust. Three-dimensional scans acquired in situ throughout triaxial compression experiments provide a distribution of density contrasts from which we estimate the three-dimensional incremental strain that accumulates between each scan acquisition. Training machine learning models on multiple experiments of six rock types provides suites of feature importance that indicate the predictive power of each feature. Comparing the average importance of groups of features that include information about each strain component quantifies the ability of the contractive, dilatational and shear strain to predict the proximity of macroscopic failure. A total of 24 models of four machine learning algorithms with six rock types indicate that 1) the dilatational strain provides the best predictive power of the strain components, and 2) the intermediate values (25th-75th percentile) of the strain population provide the best predictive power of the statistics of the strain populations. In addition, the success of the predictions of models trained on one rock type and tested on other rock types quantifies the similarities and differences of the precursory strain accumulation process in the six rock types. These similarities suggest the potential existence of a unified theory of brittle rock deformation for a range of rock types.

58 GEOSCIENCES↗

Extended Oxygen Octahedral Tilt Proximity near Oxide Heterostructures

The oxide interfaces between materials with different structural symmetries have been actively studied due to their novel physical properties. However, the investigation of intriguing interfacial phenomena caused by the oxygen octahedral tilt (OOT) proximity effect has not been fully exploited, as there is still no clear understanding of what determines the proximity length and what the underlying control mechanism is. Here, we achieved scalability of the OOT proximity effect in SrRuO 3 (SRO) by epitaxial strain near the SRO/SrTiO 3 heterointerface. We demonstrated that the OOT proximity length scale of SRO is extended from 4 unit cells to 14 unit cells by employing advanced scanning transmission electron microscopy. We also suggest that this variation may originate from changes in phonon dispersions due to electron-phonon coupling in SRO. Here, this study will provide in-depth insights into the structural gradients of correlated systems and facilitate potential device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymmetric magnetic proximity interactions in MoSe 2 /CrBr 3 van der Waals heterostructures

Magnetic proximity interactions between atomically thin semiconductors and two-dimensional magnets provide a means to manipulate spin and valley degrees of freedom in non-magnetic monolayers, without using applied magnetic fields. In such van der Waals heterostructures, magnetic proximity interactions originate in the nanometre-scale coupling between spin-dependent electronic wavefunctions in the two materials, and typically their overall effect is regarded as an effective magnetic field acting on the semiconductor monolayer. Here we demonstrate that magnetic proximity interactions in van der Waals heterostructures can in fact be markedly asymmetric. Valley-resolved reflection spectroscopy of MoSe2/CrBr3 van der Waals structures reveals strikingly different energy shifts in the K and K' valleys of the MoSe2 due to ferromagnetism in the CrBr3 layer. Density functional calculations indicate that valley-asymmetric magnetic proximity interactions depend sensitively on the spin-dependent hybridization of overlapping bands and as such are likely a general feature of hybrid van der Waals structures. Here, these studies suggest routes to control specific spin and valley states in monolayer semiconductors.

36 MATERIALS SCIENCE↗

Proximity ferroelectricity in wurtzite heterostructures

Proximity ferroelectricity is an interface-associated phenomenon in electric-field-driven polarization reversal in a non-ferroelectric polar material induced by one or more adjacent ferroelectric materials. Here, in this paper, we report proximity ferroelectricity in wurtzite ferroelectric heterostructures. In the present case, the non-ferroelectric layers are AlN and ZnO, whereas the ferroelectric layers are Al 1−x B x N, Al 1−x Sc x N and Zn 1−x Mg x O. The layered structures include nitride–nitride, oxide–oxide and nitride–oxide stacks that feature two-layer (asymmetric) and three-layer (symmetric) configurations. Ferroelectric switching in both layers is validated by multimodal characterization methods, including polarization hysteresis, anisotropic chemical etching, second harmonic generation, piezo response force microscopy, electromechanical testing and atomic resolution polarization orientation imaging in real space by scanning transmission electron microscopy. We present a physical switching model in which antipolar nuclei originate in the ferroelectric layer and propagate towards the internal non-ferroelectric interface. The domain wall leading edge produces elastic and electric fields that extend beyond the interface at close proximity, reducing the switching barrier in the non-ferroelectric layer, and allowing complete domain propagation without breakdown. Density functional theory calculations of polymorph energies, reversal barriers and domain wall energies support this model. Proximity ferroelectricity enables polarization reversal in wurtzites without the chemical or structural disorder that accompanies elemental substitution, opening new questions and opportunities regarding interface-based ferroelectricity.

36 MATERIALS SCIENCE↗

Analytical parametrization of fusion barriers using proximity potentials

Using the three versions of proximity potentials, namely proximity 1977, proximity 1988, and proximity 2000, we present a pocket formula for fusion barrier heights and positions. This was achieved by analyzing as many as 400 reactions with mass between 15 and 296. Our parametrized formula can reproduced the exact barrier heights and positions within an accuracy of +-1%. A comparison with the experimental data is also in good agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the use of the proximity force approximation for deriving limits to short-range gravitational-like interactions from sphere-plane Casimir force experiments

We discuss the role of the proximity force approximation in deriving limits to the existence of Yukawian forces--predicted in the submillimeter range by many unification models--from Casimir force experiments using the sphere-plane geometry. Two forms of this approximation are discussed, the first used in most analyses of the residuals from the Casimir force experiments performed so far, and the second recently discussed in this context in R. Decca et al.[Phys. Rev. D 79, 124021 (2009)]. We show that the former form of the proximity force approximation overestimates the expected Yukawa force and that the relative deviation from the exact Yukawa force is of the same order of magnitude, in the realistic experimental settings, as the relative deviation expected between the exact Casimir force and the Casimir force evaluated in the proximity force approximation. This implies both a systematic shift making the actual limits to the Yukawa force weaker than claimed so far, and a degree of uncertainty in the {alpha}-{lambda} plane related to the handling of the various approximations used in the theory for both the Casimir and the Yukawa forces. We further argue that the recently discussed form for the proximity force approximation is equivalent, for a geometry made of a generic object interacting with an infinite planar slab, to the usual exact integration of any additive two-body interaction, without any need to invoke approximation schemes. If the planar slab is of finite size, an additional source of systematic error arises due to the breaking of the planar translational invariance of the system, and we finally discuss to what extent this may affect limits obtained on power-law and Yukawa forces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Proximity-driven enhanced magnetic order at ferromagnetic-insulator-magnetic-topological-insulator interface

Magnetic exchange driven proximity effect at a magnetic-insulator–topological-insulator (MI-TI) interface provides a rich playground for novel phenomena as well as a way to realize low energy dissipation quantum devices. In this study, we report a dramatic enhancement of proximity exchange coupling in the MI/magnetic-TI EuS/Sb 2–x V x Te 3 hybrid heterostructure, where V doping is used to drive the TI (Sb 2 Te 3 ) magnetic. We observe an artificial antiferromagneticlike structure near the MI-TI interface, which may account for the enhanced proximity coupling. The interplay between the proximity effect and doping in a hybrid heterostructure provides insights into the engineering of magnetic ordering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences↗

Dose ratio proton radiography using the proximal side of the Bragg peak

Purpose: In recent years, there has been a movement toward single-detector proton radiography, due to its potential ease of implementation within the clinical environment. One such single-detector technique is the dose ratio method in which the dose maps from two pristine Bragg peaks are recorded beyond the patient. To date, this has only been investigated on the distal side of the lower energy Bragg peak, due to the sharp falloff. The authors investigate the limits and applicability of the dose ratio method on the proximal side of the lower energy Bragg peak, which has the potential to allow a much wider range of water-equivalent thicknesses (WET) to be imaged. Comparisons are made with the use of the distal side of the Bragg peak. Methods: Using the analytical approximation for the Bragg peak, the authors generated theoretical dose ratio curves for a range of energy pairs, and then determined how an uncertainty in the dose ratio would translate to a spread in the WET estimate. By defining this spread as the accuracy one could achieve in the WET estimate, the authors were able to generate lookup graphs of the range on the proximal side of the Bragg peak that one could reliably use. These were dependent on the energy pair, noise level in the dose ratio image and the required accuracy in the WET. Using these lookup graphs, the authors investigated the applicability of the technique for a range of patient treatment sites. The authors validated the theoretical approach with experimental measurements using a complementary metal oxide semiconductor active pixel sensor (CMOS APS), by imaging a small sapphire sphere in a high energy proton beam. Results: Provided the noise level in the dose ratio image was 1% or less, a larger spread of WETs could be imaged using the proximal side of the Bragg peak (max 5.31 cm) compared to the distal side (max 2.42 cm). In simulation, it was found that, for a pediatric brain, it is possible to use the technique to image a region with a square field equivalent size of 7.6 cm{sup 2}, for a required accuracy in the WET of 3 mm and a 1% noise level in the dose ratio image. The technique showed limited applicability for other patient sites. The CMOS APS demonstrated a good accuracy, with a root-mean-square-error of 1.6 mm WET. The noise in the measured images was found to be σ = 1.2% (standard deviation) and theoretical predictions with a 1.96σ noise level showed good agreement with the measured errors. Conclusions: After validating the theoretical approach with measurements, the authors have shown that the use of the proximal side of the Bragg peak when performing dose ratio imaging is feasible, and allows for a wider dynamic range than when using the distal side. The dynamic range available increases as the demand on the accuracy of the WET decreases. The technique can only be applied to clinical sites with small maximum WETs such as for pediatric brains.

60 APPLIED LIFE SCIENCES↗

The Distribution and Evolution of Quasar Proximity Zone Sizes

In this paper, we study the sizes of quasar proximity zones with synthetic quasar absorption spectra obtained by postprocessing a Cosmic Reionization On Computers (CROC) simulation. CROC simulations have both relatively large box sizes and high spatial resolution, allowing us to resolve Lyman limit systems (LLSs), which are crucial for modeling the quasar absorption spectra. We find that before reionization, most quasar proximity zone sizes grow steadily for ~10 Myr, while after reionization, they grow rapidly but only for ~0.1 Myr. We also find a slow growth of R obs with decreasing turn-on redshift. In addition, we find that ~1%–2% of old quasars (30 Myr old) display extremely small proximity zone sizes (<1 proper Mpc), the vast majority of which are due to the occurrence of a damped Lyα absorber (DLA) or an LLS along the line of sight. These DLAs and LLSs are contaminated with metal, which offers a way to distinguish them from the normal proximity zones of young quasars.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of Quasar Proximity Zones with the Lyα Forest of DESI Y1 Quasars

Abstract The intergalactic medium (IGM) around a quasar is shaped by its dense environment and by its excess ionizing radiation, which form a “quasar proximity zone” whose size and anisotropy depend on the quasar’s halo mass, luminosity, age, and radiation geometry. Using over 10,000 quasar pairs from the Dark Energy Spectroscopic Instrument (DESI) Year 1 data, with projected comoving separations r ⊥ < 2 h −1 Mpc, we investigate how the proximity zone of foreground quasars at z ∼ 2–3.5 affects Lyα absorption in their background quasars. The large DESI sample enables unprecedented precision in measuring this “transverse proximity” effect, allowing a detailed investigation of the signal’s dependence on the projected separation of quasar pairs and the luminosity of the foreground quasar. We find that enhanced gas clustering near quasars dominates over their ionizing effect, leading to stronger absorption on neighboring sightlines. Under the assumption that quasar ionizing luminosity is isotropic and steady, we infer the IGM overdensity profile in the vicinity of quasars, finding overdensities as high as Δ ∼ 10 at comoving distance ∼1 h −1 Mpc from the most luminous systems. Surprisingly, however, we find no significant dependence of the proximity profile on the luminosity of the foreground quasar. This lack of luminosity dependence could reflect a cancellation between higher ionizing flux and higher gas overdensity, or it could indicate that quasar emission is highly time-variable or anisotropic, so that the observed luminosity does not trace the ionizing flux on nearby sightlines.

79 ASTRONOMY AND ASTROPHYSICS↗

Proximity sensor technology for manipulator end effectors

Optical proximity sensing devices suitable for hand mounting on a manipulator are described, which use near IR LED light sources operating at 0.94 micron and silicon detectors, with appropriate signal processing so that the data are unaffected by ambient light. Laboratory tests with simple proximity sensors are described. Extension of the same techniques to yield multipoint or digital sensors is also discussed. A cooperative proximity sensor concept is described, which employs a composite mirror attached to the work piece to generate an unambiguous set of position and orientation signals. A very rudimentary experiment in local control of a manipulator with a pair of hand mounted proximity sensors is also described.

Johnston, A. R.↗