Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse circuits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Precise delay measurement through combinatorial logic

A high resolution circuit and method for facilitating precise measurement of on-chip delays for FPGAs for reliability studies. The circuit embeds a pulse generator on an FPGA chip having one or more groups of LUTS (the "LUT delay chain"), also on-chip. The circuit also embeds a pulse width measurement circuit on-chip, and measures the duration of the generated pulse through the delay chain. The pulse width of the output pulse represents the delay through the delay chain without any I/O delay. The pulse width measurement circuit uses an additional asynchronous clock autonomous from the main clock and the FPGA propagation delay can be displayed on a hex display continuously for testing purposes.

Burke, Gary R.↗

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment.

time stamp offset↗

Cheap, Easy-To-Read Frequency Monitor For Pulsed Laser

Electronic circuit provides bar-graph display of difference between carrier frequency of pulsed laser transmitter and frequency of another laser serving as local oscillator in receiver. Display device linear array of light-emitting diodes (LED's), each representing 1-MHz portion of beat-frequency range from 20 to 40 MHz. Middle LED and neighbors green; LED's representing edges of passband yellow; LED's of frequencies outside passband red. Operator determines approximate relative frequency of transmitter at a glance by observing color and position of illuminated LED.

Esporoles, Carlos↗

INPIStron switched pulsed power for dense plasma pinches

The inverse plasma switch INPIStron was employed for 10kJ/40kV capacitor bank discharge system to produce focused dense plasmas in hypocycloidal-pinch (HCP) devices. A single unit and an array of multiple HCP's were coupled as the load of the pulsed power circuit. The geometry and switching plasma dynamics were found advantageous and convenient for commutating the large current pulse from the low impedance transmission line to the low impedance plasma load. The pulse power system with a single unit HCP, the system A, was used for production of high temperature plasma focus and its diagnostics. The radially running down plasma dynamics, revealed in image converter photographs, could be simulated by a simple snow-plow model with a correction for plasma resistivity. The system B with an array of 8-HCP units which forms a long coaxial discharge chamber was used for pumping a Ti-sapphire laser. The intense UV emission from the plasma was frequency shifted with dye-solution jacket to match the absorption band of the Ti crystal laser near 500 nm. An untuned laser pulse energy of 0.6 J/pulse was obtained for 6.4 kJ/40 kV discharge, or near 103 times of the explosion limit of conventional flash lamps. For both systems the advantages of the INPIStron were well demonstrated: a single unit is sufficient for a large current (greater than 50 kA) without increasing the system impedance, highly reliable and long life operation and implied scalability for the high power ranges above I(sub peak) = 1 MA and V(sub hold) = 100 kV.

Han, Kwang S.↗

Digital Sequence Controller

Length and timing of pulse sequences user controlled. Digital circuit generates several pulse streams to control loads that must be synchronized allowing duration and phasing of each stream to be varied independently. Application of circuit to control pump for biomedical applications.

Lonborg, J. O.↗

A transformer of closely spaced pulsed waveforms

Passive circuit, using diodes, transistors, and magnetic cores, transforms the voltage of repetitive positive or negative pulses. It combines a pulse transformer with switching devices to effect a resonant flux reset and can transform various pulsed waveforms that have a nonzero average value and are relatively cosely spaced in time.

Niedra, J.↗

Digital parallel-to-series pulse-train converter

Circuit converts number represented as two level signal on n-bit lines to series of pulses on one of two lines, depending on sign of number. Converter accepts parallel binary input data and produces number of output pulses equal to number represented by input data.

Hussey, J.↗

Recovering Energy From A Rapidly Switched Gate

Circuit proposed to recover energy usually lost in charging and discharging internal gate capacitance of field-effect transistor during high-frequency switching. Scheme includes pulse-forming circuit generating rectangular waveform with zero-level notches near beginning and end of "on" period. Inductor resonates internal gate capacitance so energy recovered during notches.

Rippel, Wally E.↗

Obtaining One-Degree Accuracy With Shaft Encoders

Circuit converts output of 1-pulse-per-revolution shaft encoder to precise 360-pulses-per-revolution output. Circuit allows shaft angular position to be measured with 1-degree accuracy. With simple modifications, circuit provides higher or lower resolution from single- or multiple-pulse-perrevolution sources. Circuit used to synchronize aircraft beacon transponder-based plan-position indicator (PPI) display to remote host interrogator search antenna. Constructed using standard, commercially available components.

Franke, J. M.↗

Isolated Fast High-Voltage Switching Circuit

Electrically isolated switching circuit supplies pulses at potentials up to 6.5 kV and currents up to 6.5 A, lasting as long as few microseconds. Turn-on time about 40 ns; turn-off time about 3 microseconds. Electrically isolated from control circuitry by means of fiber-optic signal coupling and isolated power supply. Electrical isolation protects both technician and equipment. This and similar circuits useful in such industrial and scientific applications as high-voltage, high-frequency test equipment; electrostatic-discharge test equipment; plasma-laboratory instrumentation; spark chambers; and electromagnetic-interference test equipment.

Rizzi, Anthony↗

Solid-state time-to-pulse-height converter developed

Solid-state circuit produces an output pulse with an amplitude directly proportional to the time interval between two input pulses. It uses selected circuit options to achieve variable mode operation and a tunnel diode controls the charging time of a capacitor in proportion to the time interval being measured.

Lynch, R. J.↗

Four parameter pulse height analyzer

Circuit design modification of converter and readout system by addition of charge amplifiers at inputs and by addition of fourth D channel- four-parameter pulse height analyzer

PARAMETRIC AMPLIFIER↗

Feedback oscillator functions as low-level pulse stretcher

Low trigger pulses of the pulse stretcher circuit are obtained by forward biasing the transistor oscillator. The loop gain is kept below unity and prevents free-running oscillation. Two parallel feedback loops improve the stretching capabilities.

Source record↗

A spark gap switching system for gasdynamic facilities

A spark gap switching system has been developed to coordinate the discharge of a 300 kJ capacitor bank with the high speed flow of helium in a shock tube driver. The trigger system includes a flow transducer, a pulse forming circuit, a high voltage spark generator, and four heavy duty spark gaps that can carry total peak currents greater than 1.5 million A. A glow gauge flow transducer sensitive to small gas density changes was used whose input power and signal output can withstand high voltage fluctuations. This switching system is of use with gasdynamic discharge devices requiring a minimum number of switches.

Leibowitz, L. P.↗

Resistive anode image converter

The invention of an apparatus for imaging soft X-ray and ultraviolet electromagnetic radiation and charged particles was described. The apparatus includes a pair of microchannel electron multiplier plates connected in a cascaded chevron configuration which intercepts an incident beam of radiation or charged particles. Incident photons or charged particles strike the front surface of the chevron configuration causing emission of electrons. The electrons are accelerated by a voltage gradient and strike the inner side walls of the individual channels, causing emission of secondary electrons. Accelerated and multiplied secondary electrons impinge upon a resistive anode after they transverse the chevron configuration. A pulse position circuit converts the magnitude or transit time of the currents flowing from the point of impact of the electrons on the resistive anode to four contact electrodes mounted on their periphery of the resistive anode into the spatial coordinates of electron impact.

Lampton, M. L.↗

A precision star tracker utilizing advanced techniques and materials

An image dissector star tracker has been developed which operates in the photon counting mode making it possible to utilize all digital electronics. A unique pulse processing circuit allows bright stars to be tracked as well as dim stars. Thermal mechanical stability has been greatly enhanced by fabricating a housing with graphite/epoxy composite material with a linear coefficient of thermal expansion near zero. Test results indicate the +10 Mv stars can be acquired and tracked, while position variation with star intensity is less than 2 arc seconds from 2.5 Mv to +10 Mv. The noise equivalent angle for a +8 Mv star is 3 arc seconds. Polynominal correction for remaining cross-coupling and nonlinearity reduced error over total 1 x 1 deg field to 1.5 arc seconds.

Gates, R. F.↗