Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality Management System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ARM FY2026 Radar Plan

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility maintains a suite of advanced atmospheric radar systems that serve as critical tools in ARM’s mission to provide continuous, high-quality observations for advancing the understanding and modeling of atmospheric processes. These radar systems enable detailed characterization of clouds, precipitation, and dynamic structures in the atmosphere, supporting a broad range of scientific applications. The number of deployed systems exceeds what current staffing levels can fully support for continuous 24/7/365 operation. As such, it is essential to have a clearly defined and community-informed plan that prioritizes radar operations and communicates ARM’s strategy for sustaining and evolving these observational assets. This FY2026 Radar Plan outlines ARM’s approach to managing its radar portfolio—balancing scientific impact, operational feasibility, and long-term sustainability. It reflects ARM’s continued commitment to delivering calibrated, well-documented radar data products that enable process-level studies and support the development and evaluation of weather and climate models. Through this plan, ARM aims to ensure transparency in decision-making, alignment with user needs, and support for innovative science across the facility’s fixed and mobile observatories. Given uncertainties around the Fiscal Year (FY) 2026 budget, this plan was developed to assume business as usual and will be updated as budgets and plans may change. It should be noted that, given the limited timeframe involved, this plan will be more succinct than previous plans.

47 OTHER INSTRUMENTATION↗

Hot, Cold, or Just Right? Using a Wide-View Infrared Biometric Sensor to Improve Occupant Comfort and Reduce Overcooling in Buildings via Closed-loop Control (CRADA Final Report)

This research adds to the understanding of building energy management by fundamentally challenging the long-standing paradigm of controlling an environmental parameter—air temperature—and assuming occupant comfort will follow. The project developed and demonstrated a novel approach that directly senses physiological indicators of human comfort to enable closedloop, human-centric control of heating, ventilation, and air conditioning (HVAC) systems. This work shifts the focus from open-loop environmental control to a closed-loop system that prioritizes the occupants' actual thermal state. The primary benefit to the public is the potential for a simultaneous improvement in the quality of indoor environments, where people spend most of their time, and a significant reduction in national energy consumption. Overcooling, or the overuse of cooling energy in a way that discomforts occupants, wastes approximately 0.5 Quads of primary energy annually in U.S. commercial buildings and creates unproductive indoor environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six total institutions performing testing. The outcomes of this internship contribute to Fermilab s mission to advance high-energy physics and support the DOE s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [William Rainey Harper Coll.]↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos—tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab’s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE’s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six institutions performing testing. The outcomes of this internship contribute to Fermilab’s mission to advance high-energy physics and support the DOE’s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [Fermilab]↗

The Concept and Role of Reference Architectures In NIF LRU Refurbishment Factories within LLNL

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) operates one of the most advanced laser systems in the world, relying on a vast number of optical components and Line Replaceable Units (LRUs) to maintain its functionality. Over time, these components degrade due to operational wear, necessitating refurbishment to sustain performance. However, many NIF LRU refurbishment factories have been “mothballed” or suffer from aging infrastructure, inconsistent work flows, and inefficiencies due to different approaches to production control and management. This paper explores the concept of reference architecture as a standardized framework to guide the redevelopment and restructuring of NIF LRU refurbishment factories. By establishing a common reference architecture, the refurbishment process can achieve reduced inefficiencies, produce quality products, and enhanced coordination across factories. This paper evaluates existing reference architectures, particularly those that integrate technical architecture, business architecture, customer context perspectives, and proposes tailored reference architecture for NIF LRU refurbishment factories.

42 ENGINEERING↗

JUSTIFI: Open-Source Software for Identifying and Quantifying Non-Energy Benefits

The integration of Non-Energy Benefits (NEBs) into energy efficiency initiatives is essential for operational excellence in manufacturing. This presentation and software demonstration explore how quantifying NEBs such as improved safety, increased quality, and enhanced productivity, can strengthen business cases for energy investments, leading to better payback periods and alignment with organizational goals. We introduce JUSTIFI, a free, open-source software by the U.S. Department of Energy that aids in the measurement of NEBs and enhances understanding of their impact on Key Performance Indicators (KPIs) and return on investment (ROI). JUSTIFI features an intuitive interface for identifying NEBs, customizable reporting tools, and comprehensive system cataloging, empowering companies to effectively communicate the value of energy efficiency projects. By leveraging this innovative tool, organizations can better navigate energy efficiency assessments and drive support for their energy management initiatives.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Operational and Performance Monitoring of East Tennessee Technology Park Ponds—2025 Results

Performance and operational monitoring are regulatory requirements associated with a non–time-critical removal action for three surface water bodies at the East Tennessee Technology Park (ETTP) in Oak Ridge, Tennessee (Figure 1): the K-1007-P1 Pond, the K-901-A Pond, and the K-720 Slough. This progress report summarizes the monitoring activities and results from FY 2025. The goal of ecological enhancement of the K-1007-P1 and K-901-A Ponds is to reduce risk from polychlorinated biphenyl (PCB) contamination in fish to humans and wildlife. Lowering PCB concentrations in the water column and in the food that fish eat is expected to decrease PCB bioaccumulation in fish. Performance monitoring of the K-1007-P1 Pond focuses on annual PCB trends in water, clams, and fish. PCBs in fish also are sampled annually at the K-720 Slough. Operational monitoring ensures that ecological enhancement measures—including water quality, plant community, fish community, and wildlife actions—have been implemented as intended. Monitoring provides the information necessary to determine whether modifications are needed to attain the design end state (i.e., a heavily vegetated, clearwater pond dominated by sunfish with significantly diminished or at least downwardly trending PCB levels in fish). In FY 2025, fish removal efforts and vegetation planting primarily focused on the K-901-A Pond. These actions were implemented to help push the systems toward the desired end state. Descriptions of the various monitoring activities and preliminary 2025 results are provided in the following sections. An update on fish and plant management actions in FY 2025 is also included in this report. A summary of the more detailed information in this report will be presented as required in the upcoming Remediation Effectiveness Report.

54 ENVIRONMENTAL SCIENCES↗

Hydrological connectivity: a review and emerging strategies for integrating measurement, modeling, and management

This review synthesizes methods for measuring, modeling, and managing hydrologic connectivity, offering pathways to improve practices and address environmental challenges (e.g., climate change) and sustainability. As a key driver of water movement and nutrient cycling, hydrologic connectivity influences flood mitigation, water quality regulation, and biodiversity conservation. However, traditional field-based methods (e.g., dye tracing), indirect measurements (e.g., runoff analysis), and remote sensing techniques (e.g., InSAR) often struggle to capture the complexity of catchment-scale interactions. Similarly, modeling approaches—including process-based and percolation theory-based models, graph theory, and entropy-based metrics—face limitations in fully representing these interconnected processes. Both modeling and measurement techniques are constrained by inadequate spatial and temporal coverage, high data demands, computational complexity, and difficulties in representing subsurface connectivity. Subsequently, we critique current management practices that prioritize isolated variables (e.g., streamflow, sediment transport) over system-wide strategies and emphasize the need for adaptive, connectivity-based approaches in water resource planning and restoration. Moving forward, we highlight the importance of interdisciplinary collaboration, technological innovations (e.g., AI-driven modeling, real-time monitoring), and integrated frameworks to improve connectivity measurement, modeling, and adaptive management to restore fragmented hydrologic networks. This integrated approach sets the stage for transformative water resource management, fostering proactive policy development and stakeholder engagement.

Dwivedi, Dipankar↗

Glass Formulation Development for Al, Fe, and Na Phosphate HLW

The primary objective of the work described herein was to develop and identify HLW glass compositions and glass forming additive blends that achieve high waste loadings and processing rates for high phosphorus HLW streams while maintaining acceptable glass properties. Another objective was to determine the effect of phosphate form (aluminum, iron, sodium) on feed processing properties, glass production rates, and product quality while vitrifying a high phosphorus HLW stream. This was accomplished through a combination of crucible-scale tests, vertical gradient furnace tests, and confirmation tests on a DM100 melter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management and Operation of the Oak Ridge National Laboratory

ThermaMatrix, Inc provides novel vision inspection solutions for a wide range of manufacturers and industries, providing and implementing the leading technologies for nondestructive inspection (NDI) and material characterization. Many other inspection solutions are either not adequate or are not approachable due to implementation barriers needing expert level operators, excessive inspection time, and high cost. ThermaMatrix’sadvanced vision inspection technology addresses all of these limitations. The Lab Embedded Entrepreneurial Program (LEEP) opportunity by the Department of Energy (DOE) allows small-business start-ups to leverage national laboratory capabilities and skilled scientists to rapidly develop their technology that aligns with DOE goals. ThermaMatrix, Inc.was positioned in the Innovation Crossroads program at Oak Ridge National Laboratory to further develop thenovel Watson Vision Inspection System to support manufacturing quality control efforts. Theresearch goals were (1) explore fundamental parameters that would improve preexisting capabilities, (2) full-scale industrial setup for demonstration, and (3) capability testing and verification. Manufacturing is demanding more NDI implementation to support their quality control needs, which this technology development would support. Figure 1: Ryan Spencer of ThermaMatrix with Watson Vision Inspection System.

99 GENERAL AND MISCELLANEOUS↗

Machine learning of factors for improving oyster hatchery production

Oyster aquaculture and restoration in the Chesapeake Bay are vital, yet hatcheries frequently struggle with inconsistent larval growth and sudden mass mortality events. Unpredictable disruptions in larval production cause large economic losses, represent a perceived risk to growers, and impede industry expansion. To better understand associations between production yield and its potential predictors, we applied machine learning (random forest, and neural network) and statistical (generalized additive model) models to a comprehensive dataset of environmental, water quality, and operational parameters from a Maryland oyster hatchery, aiming to identify key yield predictors and develop a robust forecasting tool. We used recursive Boruta algorithm for variable selection, pinpointing critical predictors, and employed cross-validation to fine-tune model settings. Shapley value analysis offered crucial insights into model interpretations, highlighting week number, Normalized Difference Vegetation Index, salinity, turbidity, and fecundity as primary drivers of yield variability. For low-yield cases, salinity-related variables were particularly important. Our findings provide an early warning system for potential production downturns, empowering hatchery operators to make data-driven decisions for optimizing water conditions, feeding schedules, and broodstock management. By boosting predictability and efficiency, this research directly supports economic stability of the oyster industry and ecological health of the Chesapeake Bay.

Vishwakarma, Srishti [Oak Ridge National Laborator↗

LNPK 156 Geothermal Coalition: Designing and Deploying Clean Energy in a Justice40 Cold Climate Community

The LNPK 156 Geothermal Coalition formed around the idea of building a new geothermal heating and cooling system in Duluth, MN for the Lincoln Park Justice40 neighborhood. The Coalition has been spearheaded by the City of Duluth and the local non-profit Ecolibrium3, and is named after the census tract of the neighborhood containing large portions of Lincoln Park, as well as a wastewater treatment plant, managed by the Western Lake Superior Sanitary District (WLSSD). The idea of building a geothermal system came to fruition over the period of about a decade, with repeated observations that the warm water discharged from the wastewater treatment plant was an energy-rich resource that has currently been untapped and released into the St. Louis River. The objective of this project was to build a geothermal system that harnesses wastewater heat recovery methods and satisfies the demand in a portion of Lincoln Park – a neighborhood experiencing high energy burdens, low life-expectancy, and where the natural gas and fuel oil used to heat homes and businesses results in decreased air quality and increased carbon emissions. The goal was to utilize this wastewater heat recovery method to benefit the neighborhood hosting the wastewater plant itself.

15 GEOTHERMAL ENERGY↗

Study of eVTOL Charging Impact on Airport Electrical Grids

Growth in commercial air traffic has increased the aviation industry's contribution to global emissions. Aircraft electrification can reduce greenhouse gas emissions along with being efficient and reliable. Advanced air mobility introduces the idea of an advanced and more efficient air transportation system. Electric and hybrid aircraft designs, such as electric vertical takeoff and landing (eVTOL), are being considered for a number of applications, such as urban air mobility, cargo delivery, and medical emergencies. Although the electrification of aircraft provides environmental benefits, their charging needs will place significant demand on the electrical grid. This work presents a grid impact study and infrastructure upgrade requirements analysis of eVTOL charging on a realistic distribution grid through power flow simulation analysis. The case study results show that the eVTOL charging can lead to power quality issues, such as undervoltage and equipment capacity overloading. Grid infrastructure, such as lines and transformers, would need to be upgraded, and voltage management strategies would need to be deployed to accommodate eVTOL charging at an existing airport.

advanced air mobility (AAM)↗

Facilitating Data Collection of Maintenance Events to Populate the Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety and reliability for hydrogen facilities by implementing component reliability data taxonomies that support hydrogen infrastructure failure rate analysis. The project aims to quantify failure rates of hydrogen components through high-quality data collection and analysis on root causes and maintenance needed. HyCReD provides a common database for cataloging hydrogen component failures which exists for reliability research in many other mature industries [2]. The database fills a gap for the hydrogen community by providing a scientifically rigorous approach to quantitative risk assessment (QRA), prognostic health management (PHM), and reliability-centered maintenance (RCM) analysis. High level results will be aggregated and anonymized to protect company sensitive information; detailed results will be used to help address issues of hydrogen components. These advanced analytics will support accelerated deployment of hydrogen infrastructure by enabling better: design and safety of projects (safety codes and standards development), infrastructure reliability and cost (component failure rates, maintenance protocols), and component R&D needs (robust supply chain). A key to a successful HyCReD implementation is facilitating the ease of reporting and data quality in the database that can be used for analysis. Maintenance data was a previously identified gap in initial efforts to populate and validate the database taxonomies [3]. Collection of maintenance data will be instrumental in identifying failure modes and rates, identifying incipient component failures or reduced performance, cataloging best practices for maintenance routines and methods for prognostic health management, and quantifying the risk and effect of different failure modes. Several key priorities are identified for streamlined data collection to achieve quality and detailed failure data: Applicability, Ease of Use, Accessibility, and Information Security. The HyCReD team has now begun deployment of the database to several companies and groups that have signed non-disclosure agreements to facilitate the data collection of failures in industry hydrogen refueling station infrastructure. This paper will provide an update into the process of HyCReD deployment including the development of a coding guide for facility personnel to reference and ensure data quality and consistency from one station to another as well as implementation of contextually dependent data fields of system taxonomy and formatted entries to provide ease of use. The goal is to communicate the lessons learned from the roll-out to technicians and engineers in the field, and the addition of need for high level of security to protect all stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Synthesis Roadmap for Actinide Chloride Salts

Molten salt reactors (MSRs) are among the main advanced nuclear reactor types at the forefront of development by industry, with the support of the US government, for the next fleet of nuclear reactors to support the demand for energy in the coming decades. MSRs are highly unique because they are cooled and typically also fueled by molten salt. This quality brings about safety benefits such as low-pressure operation and self-stabilization of the neutron flux, operational benefits such as high-temperature operation and the ability for online refueling, and fuel and waste management benefits thanks to the flexibility of post-processing of molten salts and reprocessing options that involve removal of fission products and actinide separation. In fact, domestic deployment of molten salt (or molten salt–cooled) reactors is an approaching reality: a handful of molten salt reactor developers are planning to operate demonstration-scale reactors, as a step toward commercial-scale power reactors, within the decade. For example, Natura Resources received a construction permit in September 2024 for the deployment of MSR-1, which is a graphite-moderated thermal spectrum reactor, at Abilene Christian University. Also, TerraPower, in a collaborative effort with Southern Company and Idaho National Laboratory (INL), received approval from DOE in 2023 to proceed with the construction of the Molten Chloride Reactor Experiment (MCRE), a homogeneous chloride fast reactor at INL, and has begun assembly of system components. There are several other examples of developers at different stages of development of their own unique MSR designs (Jenet et al., 2025). As developers are in the process of obtaining approvals for their designs, deploying demonstration-scale reactors, and planning for their commercial-scale power reactors, there is a critical supply chain need for the synthesis of fuel for these reactors that must be addressed. The challenge generally is three-fold: (1) the quantity of fueled salt needed for these reactors is extraordinarily high (>100s of kilograms), but demonstrations of scaled-up techniques for fueled salt synthesis are significantly more limited than demonstrations of lab-scale syntheses; (2) each developer has a unique reactor design, which means different actinide halide elements in different carrier salts must be synthesized; and (3) there is a need for particularly high-purity salt so as to ensure the long-term operability of these reactors with minimal degradation to salt-wetted components, which necessitates synthesis techniques with high levels of quality control, repeatability, and well-characterized precursor and reactant materials. It is crucial that this supply chain challenge be addressed by demonstrating synthesis techniques that are scalable, de-risked, and well-documented so that these technologies may be adopted and utilized by industry to support the fueling needs of MSRs that are to come online within the next 10 years. With this supply chain challenge clearly defined for the developing MSR industry, it is important to consider that addressing such a challenge is oftentimes complex and context-dependent. There is not necessarily a single synthesis technique that can be scaled up and adopted to address the needs of all MSR developers; the synthesis approach that may be viable for producing a desired fuel salt will be entirely dependent on the exact salt composition needed, the quantity needed, purity needed, the refueling and waste plans, and the availability of a carrier salt for the fuel. Therefore, it is important to consider more broadly what synthesis techniques are available and have been demonstrated to understand the benefits, challenges, and general nuances that should be considered when evaluating a particular route for efficient production of high-purity fuel salts at scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ARM Lead Mentor Selection Process

The Atmospheric Radiation Measurement (ARM) Program was created in 1989 with funding from the U.S. Department of Energy (DOE) to develop several highly instrumented ground stations to study cloud-formation processes and their influence on radiative transfer. This scientific infrastructure provides for fixed sites, mobile facilities, an aerial facility, and a data archive available for use by scientists worldwide through the ARM Climate Research Facility—a scientific user facility. The ARM Climate Research Facility currently operates more than 300 instrument systems that provide ground-based observations of the atmospheric column. To keep ARM at the forefront of climate observations, the ARM infrastructure depends heavily on instrument scientists and engineers, known as Mentors. Mentors must have an excellent understanding of instrumentation theory and operation for their instrument areas and have comprehensive knowledge of critical scale-dependent atmospheric processes. They must also possess the technical and analytical skills to develop new data retrievals that provide innovative approaches for creating research-quality data sets. The ARM Facility seeks the best overall qualified candidate, or team when appropriate, that can fulfill Mentor requirements in a timely manner. The roles and responsibilities of the ARM Instrument Operations Manager are provided in Appendix A. The key role and responsibilities and detailed responsibilities of ARM Lead Mentors are provided in Appendix B and Appendix C, respectively.

47 OTHER INSTRUMENTATION↗