Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIO FREQUENCY MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A New Interferometer for Monitoring Atmospheric Phase Fluctuations

Water vapor in the Earth's troposphere introduces an extra electrical path in the propagation of radio signals through the atmosphere. The distribution of water vapor is irregular and distorts the wavefronts of incoming radio waves, limiting the angular resolution that can be achieved with ground-based telescopes. The level of fluctuations depends both on the location of the site ,and on the prevailing atmospheric conditions. The ability to measure the fluctuations is therefore important when choosing a site for a new instrument, and for scheduling observations of existing telescopes. Existing phase monitors are radio interferometers that monitor monochromatic beacon tones from geostationary communications satellites at a frequency of about 12 GHz. They have a classical heterodyne design based on two satellite receiving antennas; each has a front-end for amplifying and down-converting the incoming signals using a local oscillator that is phase-locked to a common reference frequency. In addition to multiple phase-locked loops these instruments require expensive phase-stable cabling to reduce the effects of thermal drift. The new system uses two consumer 18" digital satellite TV dishes to monitor satellite TV broadcast signals over a bandwidth of 500 MHz (12.2 to 12.7 GHz). The novel design eliminates the need for phase-locked loops and thermally stable components, and uses a pair of Gilbert Cell multipliers to perform the broadband correlation. A phase monitor has been been built and deployed at the site of the Berkeley-Illinois-Maryland Association Millimeter Array in Northern California, and has been operating successfully since June 1998, measuring the difference in electrical path length for parallel lines of sight to the satellite separated by a baseline of 100 m. With a hardware cost of approximately $4000, it is much cheaper than previous instruments, and the low power requirements and high reliability make the system suitable for site testing in remote locations.

Lay, Oliver↗

Indirect Phase Height Measurements in Central and Eastern Europe for Monitoring D Region Plasma

Low-frequency propagation experiments for the investigation of the lower part of the ionospheric D region were at first used by BRACEWELL et al. (1951) in the early fifties. Among these was the method of indirect phase height measurements for continuous monitoring of the lower ionosphere. It is based upon field strength measurements of commercial radio transmitters in the frequency range between 50 and 200 kHz at distances from 500 to 1500 km. The field strength records show characteristic diurnal variations with maxima and minima, produced by interference between the ground wave and the ionospherically reflected sky wave, the phase difference between varies in correspondence to the diurnal variation of the reflection height. In order to check the validity of interpretations of indirect phase height data, comparisons were made with simultaneous rocket soundings. Results are summarized.

Cossart, G. V.↗

Simultaneous radio and X-ray observations of the X-ray burst source MXB 1636-53

On June 17, 1977, the X-ray burst source MXB 1636-53 was simultaneously monitored for about 4 hr with the Parkes 64-m radio telescope at a frequency of 14.7 GHz and the SAS 3 X-ray satellite (1.3-12 keV). One X-ray burst was observed; an upper limit (2 sigmas) of 200 mJy is reported for any radio burst coincident with the X-ray event. During the X-ray burst the radio/X-ray time-integrated flux ratio was no more than 375 with a 90 percent confidence. An upper limit (2 sigmas) of 22 mJy was determined for any steady 14.7-GHz source coincident with the X-ray position.

Thomas, R. M.↗

Active Wireless Temperature Sensors for Aerospace Thermal Protection Systems

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life-cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to advance inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and Korteks to develop active wireless sensors that can be embedded in the thermal protection system to monitor sub-surface temperature histories. These devices are thermocouples integrated with radio-frequency identification circuitry to enable acquisition and non-contact communication of temperature data through aerospace thermal protection materials. Two generations of prototype sensors are discussed. The advanced prototype collects data from three type-k thermocouples attached to a 2.54-cm square integrated circuit.

Milos, Frank S.↗

Photonic Links for High-Performance Arraying of Antennas

An architecture for arraying microwave antennas in the next generation of NASA s Deep Space Network (DSN) involves the use of all photonic links between (1) the antennas in a given array and (2) a signal processing center. In this architecture, all affected parts at each antenna pedestal [except a front-end low-noise amplifier for the radio-frequency (RF) signal coming from the antenna and an optical transceiver to handle monitor and control (M/C) signals] would be passive optical parts

Huang, Shouhua↗

The Spectrum Outlook for Earth Remote Sensing Post WRC-19

Every three to four years the International Telecommunication Union (ITU), a specialized agency of the United Nations, holds a treaty level meeting known as the World Radiocommunication Conference (WRC) to set international regulations on the use of the radio frequency spectrum. These regulations include protections for critical remote sensing bands. This paper presents the background information on, and the outcomes of, WRC-19. It also provides an examination of the potential regulatory actions that could impact the remote sensing community at the next WRC slated to be held in 2023. Lastly, the paper discusses the need for coordinated, intercalibrated interference monitoring and reporting within the remote sensing community.

radio frequency interference↗

A gamma-ray pulsar timing array constrains the nanohertz gravitational wave background

We report after large galaxies merge, their central supermassive black holes are expected to form binary systems. Their orbital motion should generate a gravitational wave background (GWB) at nanohertz frequencies. Searches for this background use pulsar timing arrays, which perform long-term monitoring of millisecond pulsars at radio wavelengths. We used 12.5 years of Fermi Large Area Telescope data to form a gamma-ray pulsar timing array. Results from 35 bright gamma-ray pulsars place a 95% credible limit on the GWB characteristic strain of 1.0 × 10 -14 at a frequency of 1 year –1 . The sensitivity is expected to scale with t obs , the observing time span, as t$^{-13/6}_{obs}$. This direct measurement provides an independent probe of the GWB while offering a check on radio noise models.

79 ASTRONOMY AND ASTROPHYSICS↗

Wireless Subsurface Sensors for Health Monitoring of Thermal Protection Systems on Hypersonic Vehicles

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles (RLVs) in order to reduce life cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to develop inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and industry partners to develop "wireless" devices that can be embedded in the thermal protection system to monitor temperature or other quantities of interest. These devices are sensors integrated with radio-frequency identification (RFID) microchips to enable non-contact communication of sensor data to an external reader that may be a hand-held scanner or a large portal. Both passive and active prototype devices have been developed. The passive device uses a thermal fuse to indicate the occurrence of excessive temperature. This device has a diameter under 0.13 cm. (suitable for placement in gaps between ceramic TPS tiles on an RLV) and can withstand 370 C for 15 minutes. The active device contains a small battery to provide power to a thermocouple for recording a temperature history during flight. The bulk of the device must be placed beneath the TPS for protection from high temperature, but the thermocouple can be placed in a hot location such as near the external surface.

Milos, Frank S.↗

Development of an IEEE Standard to Assess Interference on Remote Sensing Frequency Bands

Radio Frequency Interference contamination for Earth Observation satellites is an on-growing problem, but the situation is not properly reported. A new IEEE standard is being developed to quantify the amount of RFI in the frequency bands used by remote sensing satellites. This standard will allow for a proper monitoring of the RFI trends in each frequency band

Radio Frequency Interference↗

Additively Manufactured Tamper Evident Container (TEC)

The protection of sensitive data, proprietary information, and physical assets from adversarial disclosure is a high priority in today’s environment of government and industrial espionage. Furthermore, knowledge of the security history and monitoring for potential acquisition or disclosure of the protected assets from oppositional sources is equally important. In 2016, as part of an LANL Institute for Materials Science (IMS) rapid response research initiative, the investigators of this technology demonstration project developed the concept of an additively manufactured tamper resistant container that possessed tamper evident features. Tamper evident seals and detection technologies have a long history in protecting consumers from product tampering, recording the installation and activation of mechanical safety panels and fasteners on dangerous electro-mechanical systems, and serving as a warranty void indicator on expensive electronic equipment. Examples of such tamper evident seals range from “no-tech” versions, e.g., the paper seals under medicine caps, to “high-tech” seals that are radio frequency-active and include encryption capabilities used by the International Atomic Energy Agency (IAEA) to monitor stored nuclear materials in support of safeguards missions. The tamper evident container (TEC) technology would have many uses.

36 MATERIALS SCIENCE↗

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Wireless Subsurface Microsensors for Health Monitoring of Thermal Protection Systems on Hypersonic Vehicles

Health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles in order to reduce life cycle costs, to increase safety margins, and to improve mission reliability. NASA Ames is leading the effort to develop inspection and health management technologies for thermal protection systems. This paper summarizes a joint project between NASA Ames and SRI International to develop 'SensorTags,' radio frequency identification devices coupled with event-recording sensors, that can be embedded in the thermal protection system to monitor temperature or other quantities of interest. Two prototype SensorTag designs containing thermal fuses to indicate a temperature overlimit are presented and discussed.

Milos, Frank S.↗

Shielding the Quantum Realm: Technical Considerations for Maintaining a Stable and Secure Radio Frequency Environment for Quantum Research

Advancements in quantum technology, which include quantum computing, quantum sensing, quantum communications, and associated research, continue to revolutionize various fields of study by solving challenging problems deemed too difficult or more efficient than those used for classical computers. However, as these systems become ever so complex, it is critical to secure their electromagnetic operational environments and the associated impact on quantum systems and infrastructure. The goal of this synopsis is to bring attention to the susceptibility of quantum technology facilities to potential issues related to the radio frequency (RF) environment within the broader electromagnetic context. A framework is proposed for identifying, mitigating, monitoring, and auditing these often complex operational environments. By establishing best practices in the consideration and evaluation of these criteria, one can enhance the operational integrity, resilience, and security of quantum technology systems and facilities, thereby supporting their continued development and application in research and industry.

42 ENGINEERING↗

Radiative lifetime of the 5S2 metastable state of N/+/

The radiative lifetime of metastable N(+)(5S2) has been measured to be 4.2 + or - 0.6 msec, a value generally in agreement with theory, by direct monitoring of the spontaneous emission from approximately 1,000,000 ions stored in a radio-frequency ion trap. Additional measurements were made of the quenching rate coefficient (2.5 x 10 to the -9th cu cm/sec) and the production cross section (greater than or equal to 10 to the -18th sq cm) of N(+)(5S2) in N2. This work supports the interpretation of the 2145-A feature in the spectrum of aurorae as being due to N(+)(5S2) emission.

Knight, R. D.↗

A Multi-Center Space Data System Prototype Based on CCSDS Standards

Deep space missions beyond earth orbit will require new methods of data communications in order to compensate for increasing Radio Frequency (RF) propagation delay. The Consultative Committee for Space Data Systems (CCSDS) standard protocols Spacecraft Monitor & Control (SM&C), Asynchronous Message Service (AMS), and Delay/Disruption Tolerant Networking (DTN) provide such a method. However, the maturity level of this protocol stack is insufficient for mission inclusion at this time. This Space Data System prototype is intended to provide experience which will raise the Technical Readiness Level (TRL) of this protocol set. In order to reduce costs, future missions can take advantage of these standard protocols, which will result in increased interoperability between control centers. This prototype demonstrates these capabilities by implementing a realistic space data system in which telemetry is published to control center applications at the Jet Propulsion Lab (JPL), the Marshall Space Flight Center (MSFC), and the Johnson Space Center (JSC). Reverse publishing paths for commanding from each control center are also implemented. The target vehicle consists of realistic flight computer hardware running Core Flight Software (CFS) in the integrated Power, Avionics, and Power (iPAS) Pathfinder Lab at JSC. This prototype demonstrates a potential upgrade path for future Deep Space Network (DSN) modification, in which the automatic error recovery and communication gap compensation capabilities of DTN would be exploited. In addition, SM&C provides architectural flexibility by allowing new service providers and consumers to be added efficiently anywhere in the network using the common interface provided by SM&C's Message Abstraction Layer (MAL). In FY 2015, this space data system was enhanced by adding telerobotic operations capability provided by the Robot API Delegate (RAPID) family of protocols developed at NASA. RAPID is one of several candidates for consideration and inclusion in a new international standard being developed by the CCSDS Telerobotic Operations Working Group. Software gateways for the purpose of interfacing RAPID messages with the existing SM&C based infrastructure were developed. Telerobotic monitor, control, and bridge applications were written in the RAPID framework, which were then tailored to the NAO telerobotic test article hardware, a product of Aldebaran Robotics.

Rich, Thomas M.↗

VLF Radio Field Strength Measurement of power line carrier system in San Diego, California

The radio frequency interference (RFI) potential was evaluated for a Powerline Carriet (PLC) installed in San Diego which monitors the performance of an electrical power system. The PLC system generated 30 amperes at 5.79 kHz. The RF radiations were measured to be (typically) 120 dBuV/m at the beginning of the 12 kV powerline and 60 dBuV/m at the end of the powerline. The RF fields varied inversely as the distance squared. Measurements were also performed with a 45 kHz PLC system. The RF fields were of similar amplitude.

Mertel, H. K.↗

In search of Uranian decametric emission

An experiment to detect decametric radiation from Uranus is described. It is argued that in light of recent discoveries of a magnetic field on Uranus, it may be possible to detect low-frequency radio emission similar to the decametric emission from Jupiter. The experiment consisted of 106 hours of monitoring using the 26.3 MHz array of the University of Florida Dixie County Radio Observatory. No radiation from Uranus was detected. An upper flux density limit of 400 Jy was obtained.

Lebo, G. R.↗