Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIONUCLIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Decontamination of Terrorist-Dispersed Radionuclides from Surfaces in Urban Environments

Research is currently underway at Lawrence Livermore National Laboratory (LLNL) to advance the basic scientific knowledge of radionuclide-substrate interactions in the urban environment. Investigations have focused on more optimized decontamination agents for cesium (Cs) and americium (Am) specifically for use in mass transit infrastructure and urban environments. This project is designed to enhance the capability of the United States to effectively respond to a Radiological Dispersal Device (RDD) attack. The work addresses recognized data gaps by advancing the basic scientific knowledge of radionuclide-substrate interactions in the urban environment and provides a solution to a national need. The research is focused in four major areas: (1) a better understanding of urban surface conditions that influence the efficacy of decontamination processes, (2) development of prototype decontamination agents for Am and Cs optimized for use in urban environments, (3) the development of capabilities to realistically contaminate surfaces at both the real world and laboratory scale and (4) a validated model for radionuclide-surface interactions. The decontamination of urban surfaces following the detonation of an RDD presents a number of challenges. The following key points are found to be critical for the efficiency of decontamination agents in an urban environment: - Particle size and surface deposition of radionuclide particles on urban surface materials. - Interactions between radionuclides and urban materials. - The presence of grime and carbonation/alteration layers on the surface of urban surfaces. - Post-detonation penetration of radionuclides strongly affected by the dynamic wetting/drying processes. A laboratory scale contamination system has been developed allowing for samples to be contaminated and radionuclide interactions to be studied. In combination with laboratory scale experiments, a real scale outdoor test is scheduled for the spring of 2007. In conclusion, integrated laboratory, field, and numerical approaches are utilized to better understand the radionuclide behavior and the development/utility of decontamination agents.

54 ENVIRONMENTAL SCIENCES↗

ASSESSMENT OF RADIONUCLIDES DATABASES IN CAP88 MAINFRAME VERSION 1.0 AND WINDOWS-BASED VERSION 3.0

In this study the radionuclide databases for two versions of the Clean Air Act Assessment Package-1988 (CAP88) computer model were assessed in detail. CAP88 estimates radiation dose and the risk of health effects to human populations from radionuclide emissions to air. This program is used by several Department of Energy (DOE) facilities to comply with National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. CAP88 Mainframe, referred to as Version 1.0 on the Environmental Protection Agency (EPA) website (http://www.epa.gov/radiation/assessment/CAP88/), was the very first CAP88 version released in 1988. Some DOE facilities including the Savannah River Site still employ this version (1.0) while others use the more user-friendly personal computer Windows-based Version 3.0 released in December 2007. Version 1.0 uses the program RADRISK based on International Commission on Radiological Protection (ICRP) Publication 30 as its radionuclide database. Version 3.0 uses half-life, dose and risk factor values based on Federal Guidance Report 13. Differences in these values could cause different results for the same input exposure data (same scenario), depending on which version of CAP88 is used. Consequently, the differences between the two versions are being assessed in detail at Savannah River National Laboratory. The version 1.0 and 3.0 database files contain 496 and 838 radionuclides, respectively, and though one would expect the newer version to include all the 496 radionuclides, thirty-five radionuclides are listed in version 1.0 that are not included in version 3.0. The majority of these has either extremely short or long half-lives or is no longer in production; however, some of the short-lived radionuclides might produce progeny of great interest at DOE sites. In addition, one hundred and twenty-two radionuclides were found to have different half-lives in the two versions, with 21 over 3 percent different and 12 over 10 percent different.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A High Separation Factor for 165Er from Ho for Targeted Radionuclide Therapy

Background: Radionuclides emitting Auger electrons (AEs) with low (0.02–50 keV) energy, short (0.0007–40 µm) range, and high (1–10 keV/µm) linear energy transfer may have an important role in the targeted radionuclide therapy of metastatic and disseminated disease. Erbium-165 is a pure AE-emitting radionuclide that is chemically matched to clinical therapeutic radionuclide 177Lu, making it a useful tool for fundamental studies on the biological effects of AEs. This work develops new biomedical cyclotron irradiation and radiochemical isolation methods to produce 165Er suitable for targeted radionuclide therapeutic studies and characterizes a new such agent targeting prostate-specific membrane antigen. Methods: Biomedical cyclotrons proton-irradiated spot-welded Ho(m) targets to produce 165Er, which was isolated via cation exchange chromatography (AG 50W-X8, 200–400 mesh, 20 mL) using alpha-hydroxyisobutyrate (70 mM, pH 4.7) followed by LN2 (20–50 µm, 1.3 mL) and bDGA (50–100 µm, 0.2 mL) extraction chromatography. The purified 165Er was radiolabeled with standard radiometal chelators and used to produce and characterize a new AE-emitting radiopharmaceutical, [165Er]PSMA-617. Results: Irradiation of 80–180 mg natHo targets with 40 µA of 11–12.5 MeV protons produced 165Er at 20–30 MBq·µA−1·h−1. The 4.9 ± 0.7 h radiochemical isolation yielded 165Er in 0.01 M HCl (400 µL) with decay-corrected (DC) yield of 64 ± 2% and a Ho/165Er separation factor of (2.8 ± 1.1) · 105. Radiolabeling experiments synthesized [165Er]PSMA-617 at DC molar activities of 37–130 GBq·µmol−1. Conclusions: A 2 h biomedical cyclotron irradiation and 5 h radiochemical separation produced GBq-scale 165Er suitable for producing radiopharmaceuticals at molar activities satisfactory for investigations of targeted radionuclide therapeutics. This will enable fundamental radiation biology experiments of pure AE-emitting therapeutic radiopharmaceuticals such as [165Er]PSMA-617, which will be used to understand the impact of AEs in PSMA-targeted radionuclide therapy of prostate cancer.

165Er↗

Determination Of Reportable Radionuclides For DWPF Sludge Batch 7B (Macrobatch 9)

The Waste Acceptance Product Specifications (WAPS) 1.2 require that “The Producer shall report the inventory of radionuclides (in Curies) that have half-lives longer than 10 years and that are, or will be, present in concentrations greater than 0.05 percent of the total inventory for each waste type indexed to the years 2015 and 3115”. As part of the strategy to comply with WAPS 1.2, the Defense Waste Processing Facility (DWPF) will report for each waste type, all radionuclides (with half-lives greater than 10 years) that have concentrations greater than 0.01 percent of the total inventory from time of production through the 1100 year period from 2015 through 3115. The initial listing of radionuclides to be included is based on the design-basis glass as identified in the Waste Form Compliance Plan (WCP) and Waste Form Qualification Report (WQR). However, it is required that this list be expanded if other radionuclides with half-lives greater than 10 years are identified that may meet the greater than 0.01% criterion for Curie content. Specification 1.6 of the WAPS, International Atomic Energy Agency (IAEA) Safeguards Reporting for High Level Waste (HLW), requires that the ratio by weights of the following uranium and plutonium isotopes be reported: U-233, U-234, U-235, U-236, U-238, Pu-238, Pu-239, Pu-240, Pu-241, and Pu-242. Therefore, the complete set of reportable radionuclides must also include this set of U and Pu isotopes. The DWPF is receiving radioactive sludge slurry from HLW Tank 40. The radioactive sludge slurry in Tank 40 is a blend of the heel from Sludge Batch 7a (SB7a) and Sludge Batch 7b (SB7b) that was transferred to Tank 40 from Tank 51. The blend of sludge in Tank 40 is also referred to as Macrobatch 9 (MB9). This report develops the list of reportable radionuclides and associated activities as a function of time. The DWPF will use this list and the activities as one of the inputs for the development of the Production Records that relate to radionuclide inventory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mobility of Source Zone Heavy Metals and Radionuclides: The Mixed Roles of Fermentative Activity on Fate and Transport of U and Cr. Final Report

Various U. S. Department of Energy (DOE) low and medium-level radioactive waste sites contain mixtures of heavy metals, radionuclides and assorted organic materials. In addition, there are numerous sites around the world that are contaminated with a mixture of organic and inorganic contaminants. In most sites, over time, water infiltrates the wastes, and releases metals, radionuclides and other contaminants causing transport into the surrounding environment. We investigated the role of fermentative microorganisms in such sites that may control metal, radionuclide and organics migration from source zones. The project was initiated based on the following overarching hypothesis: Metals, radionuclides and other contaminants can be mobilized by infiltration of water into waste storage sites. Microbial communities of lignocellulose degrading and fermenting microorganisms present in the subsurface of contaminated DOE sites can significantly impact migration by directly reducing and immobilizing metals and radionuclides while degrading complex organic matter to low molecular weight organic compounds. These low molecular weight organic acids and alcohols can increase metal and radionuclide mobility by chelation (i.e., certain organic acids) or decrease mobility by stimulating respiratory metal reducing microorganisms. We demonstrated that fermentative organisms capable of affecting the fate of Cr6+, U6+ and trinitrotoluene can be isolated from organic-rich low level waste sites as well as from less organic rich subsurface environments. The mechanisms, pathways and extent of contaminant transformation depend on a variety of factors related to the type of organisms present, the aqueous chemistry as well as the geochemistry and mineralogy. This work provides observations and quantitative data across multiple scales that identify and predict the coupled effects of fermentative carbon and electron flow on the transport of radionuclides, heavy metals and organic contaminants in the subsurface; a primary concern of the DOE Environmental Remediation Science Division (ERSD) and Subsurface Geochemical Research (SBR) Program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Emission Standards for Hazardous Air Pollutants - Radionuclide Emissions Calendar Year 2013

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office (NNSA/NFO) operates the Nevada National Security Site (NNSS) and North Las Vegas Facility (NLVF). From 1951 through 1992, the NNSS was the continental testing location for U.S. nuclear weapons. The release of radionuclides from NNSS activities has been monitored since the initiation of atmospheric testing. Limitations to underground detonations after 1962 greatly reduced radiation exposure to the public surrounding the NNSS. After nuclear testing ended in 1992, NNSS radiation monitoring focused on detecting airborne radionuclides from historically contaminated soils. These radionuclides are derived from re-suspension of soil (primarily by wind) and emission of tritium-contaminated soil moisture through evapotranspiration. Low amounts of legacy-related tritium are also emitted to air at the NLVF, an NNSS support complex in North Las Vegas. To protect the public from harmful levels of man-made radiation, the Clean Air Act, National Emission Standards for Hazardous Air Pollutants (NESHAP) (Title 40 Code of Federal Regulations [CFR] Part 61 Subpart H) (CFR 2010a) limits the release of radioactivity from a U.S. Department of Energy (DOE) facility to that which would cause 10 millirem per year (mrem/yr) effective dose equivalent to any member of the public. This limit does not include radiation unrelated to NNSS activities. Unrelated doses could come from naturally occurring radioactive elements, from sources such as medically or commercially used radionuclides, or from sources outside of the United States, such as the damaged Fukushima nuclear power plant in Japan in 2011. NNSA/NFO demonstrates compliance with the NESHAP limit by using environmental measurements of radionuclide air concentrations at critical receptor locations on the NNSS (U.S. Environmental Protection Agency [EPA] and DOE 1995). This method was approved by the EPA for use on the NNSS in 2001 (EPA 2001a) and has been the sole method used since 2005. Six locations on the NNSS have been established to act as critical receptor locations to demonstrate compliance with the NESHAP limit. These locations are actually pseudo-critical receptor stations, because no member of the public actually resides at these onsite locations. Compliance is demonstrated if the measured annual average concentration is less than the NESHAP Concentration Levels (CLs) for Environmental Compliance listed in 40 CFR 61, Appendix E, Table 2 (CFR 2010a). For multiple radionuclides, compliance is demonstrated when the sum of the fractions (determined by dividing each radionuclide’s concentration by its CL and then adding the fractions together) is less than 1.0. In 2013, the potential dose from radiological emissions to air, resulting from both current and past NNSS activities, was well below the 10 mrem/yr dose limit. Air sampling data collected at all air monitoring stations had average concentrations of radioactivity that were a fraction of the CL values. Concentrations ranged from 0.2% to a maximum of 10.1% of the allowed NESHAP limit. Because the nearest member of the public resides about 9 kilometers from potential release points on the NNSS, dose to the public would be only a small fraction of the value measured on the NNSS. The potential dose to the public from NLVF emissions was also very low at 0.000011 mrem/yr, more than 900,000 times lower than the 10 mrem/yr limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for radionuclide redistribution due to biotic intrusion: Aboveground biomass study at the Los Alamos National Laboratory for the closure of Material Disposal Area G

Low-level radioactive waste generated at the Los Alamos National Laboratories (LANL) is disposed of at Technical Area (TA) 54, Material Disposal Area (MDA) G. The ability of MDA G to safely contain radioactive waste was evaluated in the facility's performance assessment (PA) and composite analysis (CA). The PA and CA project that, due to uptake and incorporation of radionuclides into aboveground plant material, plant roots penetrating into buried waste may lead to releases of radionuclides to the accessible environment and potentially lead to the exposure to members of the public. The potential amount of contamination deposited on the ground surface, due to plant intrusion into buried waste, is a function of the quantity of litter generated by plants, as well as radionuclide concentrations within the litter. Radionuclide concentrations in plant litter is dependent on the distribution of root mass with depth and the efficiency with which radionuclides are extracted from contaminated soils by the plants roots. In order to reduce uncertainties associated with the PA and CA for MDA G, aboveground biomass surveys, plant litter production rates, and root mass with depth analyses for the four prominent vegetation types (grasses, forbs, shrubs and trees) are being conducted. Sampling occurred during the months of August and September of 2007 which measured aboveground biomass for the types of grasses and forbs that may become established at MDA G after the disposal facility undergoes final closure. Biomass data are representative of the future potential for the amount of contaminated plant litter fall, which could act as a latent conduit for radionuclide transport from the closed disposal area. Follow on work will be conducted to evaluate frequency and coverage of all growth forms, litter production rates will be measured, and root mass with depth for grasses, forbs, shrubs, and trees will be analyzed. Together, data collected are expected to reduce uncertainties associated with the PA and CA for MDA G and ultimately aid in the prevention of radionuclide transport within the environment from the closed disposal area and exposure to the public. In summary: Collection of aboveground grasses and forbs at TA-54 resulted in dry-weight biomass data for two of the four growth forms of interest for the MDA G PA and CA. Shrubs were not encountered in any of the grid cells selected for sampling. Trees were not encountered within MDA J. Mature trees (Juniper) were located in five grid cell locations at Zone 4. Dead and down trees (Pinon) were located in two of the grid cells at Zone 4. The grid size at MDA J was reduced to 15.2 m by 15.2 m (50 ft by 50 ft) because of the anticipated mass to be collected. MDA J has achieved a relatively uniform grass and forbs coverage, and due to time constraints the size was reduced by half. Material that was originally oven dried was weighed again after several weeks. Data from post oven drying reports weight gain, indicating a higher error associated with air versus oven drying methodology. The drying methods will be explored in greater depth with future studies. Future surveys will include measurement of aboveground biomass of shrubs and trees, measurement of litter production rates; root mass with depth for grasses, forbs, shrubs, and trees; and frequency and coverage surveys to determine the percent coverage of each growth form. The collection of this additional data will provide further site-specific information regarding the growth of grasses, forbs, shrubs, and trees within the expected successional growth stages expected at MDA G. These data will be incorporated into the biotic intrusion modeling for the MDA G PA and CA. (authors)

54 ENVIRONMENTAL SCIENCES↗

Radionuclide Inventory Distribution Project Data Evaluation and Verification White Paper

Testing of nuclear explosives caused widespread contamination of surface soils on the Nevada Test Site (NTS). Atmospheric tests produced the majority of this contamination. The Radionuclide Inventory and Distribution Program (RIDP) was developed to determine distribution and total inventory of radionuclides in surface soils at the NTS to evaluate areas that may present long-term health hazards. The RIDP achieved this objective with aerial radiological surveys, soil sample results, and in situ gamma spectroscopy. This white paper presents the justification to support the use of RIDP data as a guide for future evaluation and to support closure of Soils Sub-Project sites under the purview of the Federal Facility Agreement and Consent Order. Use of the RIDP data as part of the Data Quality Objective process is expected to provide considerable cost savings and accelerate site closures. The following steps were completed: - Summarize the RIDP data set and evaluate the quality of the data. - Determine the current uses of the RIDP data and cautions associated with its use. - Provide recommendations for enhancing data use through field verification or other methods. The data quality is sufficient to utilize RIDP data during the planning process for site investigation and closure. Project planning activities may include estimating 25-millirem per industrial access year dose rate boundaries, optimizing characterization efforts, projecting final end states, and planning remedial actions. In addition, RIDP data may be used to identify specific radionuclide distributions, and augment other non-radionuclide dose rate data. Finally, the RIDP data can be used to estimate internal and external dose rates. The data quality is sufficient to utilize RIDP data during the planning process for site investigation and closure. Project planning activities may include estimating 25-millirem per industrial access year dose rate boundaries, optimizing characterization efforts, projecting final end states, and planning remedial actions. In addition, RIDP data may be used to identify specific radionuclide distributions, and augment other non-radionuclide dose rate data. Finally, the RIDP data can be used to estimate internal and external dose rates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radionuclide Sensors for Environmental Monitoring: From Flow Injection Solid-Phase Absorptiometry to Equilibration-Based Preconcentrating Minicolumn Sensors with Radiometric Detection

The development of in situ sensors for ultratrace detection applications in process control and environmental monitoring remains a significant challenge. Such sensors must meet difficult detection limit requirements while selectively detecting the analyte of interest in complex or otherwise challenging sample matrixes. Nowhere are these requirements more daunting than in the field of radionuclide sensing. The detection limit requirements can be extremely low. Nevertheless, a promising approach to radionuclide sensing based on preconcentrating minicolumn sensors has been developed. In addition, a method of operating such sensors, which we call equilibration-based sensing, has been developed that provides substantial preconcentration and a signal that is proportional to analyte concentration, while eliminating the need for reagents to regenerate the sorbent medium following each measurement. While this equilibration-based sensing method was developed for radionuclide sensing, it can be applied to nonradioactive species as well, given a suitable on-column detection system. By replacing costly sampling and laboratory analysis procedures, in situ sensors could have a significant impact on monitoring and long term stewardship applications. The aim of this review is to cover radionuclide sensors that combine some form of selective sorption with a radiometric detection method, and­as a primary aim­to comprehensively review preconcentrating minicolumn sensors for radionuclide detection. As a secondary aim, we will cover radionuclide sensors that combine sorption and scintillation in formats other than minicolumn sensors. We are particularly concerned with the detection of alpha- and beta-emitting radionuclides, which present particular challenges for measurements in liquid media.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solubility of {sup 238}U radionuclide from various types of soil in synthetic gastrointestinal fluids using “US in vitro” digestion method

238U radionuclide is a naturally occuring radioactive material that can be found in soil. In this study, the solubility of 238U radionuclide obtained from various types of soil in synthetic gastrointestinal fluids was analysed by “US P in vitro” digestion method. The synthetic gastrointestinal fluids were added to the samples with well-ordered, mixed throughly and incubated according to the human physiology digestive system. The concentration of 238U radionuclide in the solutions extracted from the soil was measured using Induced Coupling Plasma Mass Spectrometer (ICP-MS). The concentration of 238U radionuclide from the soil samples in synthetic gastrointestinal fluids showed different values due to different homogenity of soil types and chemical reaction of 238U radionuclide. In general, the solubility of 238U radionuclide in gastric fluid was higher (0.050 – 0.209 ppm) than gastrointestinal fluids (0.024 – 0.050 ppm). It could be concluded that the US P in vitro digestion method is practicle for estimating the solubility of 238U radionuclide from soil materials and could be useful for monitoring and risk assessment purposes applying to environmental, health and contaminated soil samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Differences among Monte Carlo codes in the calculations of voxel S values for radionuclide targeted therapy and analysis of their impact on absorbed dose evaluations

Several updated Monte Carlo (MC) codes are available to perform calculations of voxel S values for radionuclide targeted therapy. The aim of this work is to analyze the differences in the calculations obtained by different MC codes and their impact on absorbed dose evaluations performed by voxel dosimetry. Voxel S values for monoenergetic sources (electrons and photons) and different radionuclides ({sup 90}Y, {sup 131}I, and {sup 188}Re) were calculated. Simulations were performed in soft tissue. Three general-purpose MC codes were employed for simulating radiation transport: MCNP4C, EGSnrc, and GEANT4. The data published by the MIRD Committee in Pamphlet No. 17, obtained with the EGS4 MC code, were also included in the comparisons. The impact of the differences (in terms of voxel S values) among the MC codes was also studied by convolution calculations of the absorbed dose in a volume of interest. For uniform activity distribution of a given radionuclide, dose calculations were performed on spherical and elliptical volumes, varying the mass from 1 to 500 g. For simulations with monochromatic sources, differences for self-irradiation voxel S values were mostly confined within 10% for both photons and electrons, but with electron energy less than 500 keV, the voxel S values referred to the first neighbor voxels showed large differences (up to 130%, with respect to EGSnrc) among the updated MC codes. For radionuclide simulations, noticeable differences arose in voxel S values, especially in the bremsstrahlung tails, or when a high contribution from electrons with energy of less than 500 keV is involved. In particular, for {sup 90}Y the updated codes showed a remarkable divergence in the bremsstrahlung region (up to about 90% in terms of voxel S values) with respect to the EGS4 code. Further, variations were observed up to about 30%, for small source-target voxel distances, when low-energy electrons cover an important part of the emission spectrum of the radionuclide (in our case, for {sup 131}I). For {sup 90}Y and {sup 188}Re, the differences among the various codes have a negligible impact (within few percents) on convolution calculations of the absorbed dose; thus either one of the MC programs is suitable to produce voxel S values for radionuclide targeted therapy dosimetry. However, if a low-energy beta-emitting radionuclide is considered, these differences can affect also dose depositions at small source-target voxel distances, leading to more conspicuous variations (about 9% for {sup 131}I) when calculating the absorbed dose in the volume of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of specific calibration coefficients for gamma-emitting sources measured by radionuclide calibrators in nuclear medicine

Purpose: In nuclear medicine, the activity of a radionuclide is measured with a radionuclide calibrator that often has a calibration coefficient independent of the container type and filling. Methods: To determine the effect of the container on the accuracy of measuring the activity injected into a patient, The authors simulated a commercial radionuclide calibrator and 18 container types most typically used in clinical practice. The instrument sensitivity was computed for various container thicknesses and filling levels. Monoenergetic photons and electrons as well as seven common radionuclides were considered. Results: The quality of the simulation with gamma-emitting sources was validated by an agreement with measurements better than 4% in five selected radionuclides. The results show that the measured activity can vary by more than a factor of 2 depending on the type of container. The filling level and the thickness of the container wall only have a marginal effect for radionuclides of high energy but could induce differences up to 4%. Conclusions: The authors conclude that radionuclide calibrators should be tailored to the uncertainty required by clinical applications. For most clinical cases, and at least for the low-energy gamma and x-ray emitters, measurements should be performed with calibration coefficients specific to the container type.

61 RADIATION PROTECTION AND DOSIMETRY↗

Innovative methodology for intercomparison of radionuclide calibrators using short half-life in situ prepared radioactive sources

Purpose: An original radionuclide calibrator method for activity determination is presented. The method could be used for intercomparison surveys for short half-life radioactive sources used in Nuclear Medicine, such as{sup 99m}Tc or most positron emission tomography radiopharmaceuticals. Methods: By evaluation of the resulting net optical density (netOD) using a standardized scanning method of irradiated Gafchromic XRQA2 film, a comparison of the netOD measurement with a previously determined calibration curve can be made and the difference between the tested radionuclide calibrator and a radionuclide calibrator used as reference device can be calculated. To estimate the total expected measurement uncertainties, a careful analysis of the methodology, for the case of{sup 99m}Tc, was performed: reproducibility determination, scanning conditions, and possible fadeout effects. Since every factor of the activity measurement procedure can influence the final result, the method also evaluates correct syringe positioning inside the radionuclide calibrator. Results: As an alternative to using a calibrated source sent to the surveyed site, which requires a relatively long half-life of the nuclide, or sending a portable calibrated radionuclide calibrator, the proposed method uses a source preparedin situ. An indirect activity determination is achieved by the irradiation of a radiochromic film using {sup 99m}Tc under strictly controlled conditions, and cumulated activity calculation from the initial activity and total irradiation time. The irradiated Gafchromic film and the irradiator, without the source, can then be sent to a National Metrology Institute for evaluation of the results. Conclusions: The methodology described in this paper showed to have a good potential for accurate (3%) radionuclide calibrators intercomparison studies for{sup 99m}Tc between Nuclear Medicine centers without source transfer and can easily be adapted to other short half-life radionuclides.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-666: Radionuclides and Activity of the Patient Apertures Used in a Proton Beam of Wobbling System

Purpose: To identify the radionuclides and quantify the activity of the patient apertures used in a 190-MeV proton beam of wobbling system. Methods: A proton beam of wobbling system in the first proton center in Taiwan, Chang Gung Memorial Hospital at Linkou, was used to bombard the patient apertures. The patient aperture was composed of 60.5 % copper, 39.4 % Zinc, 0.05 % iron, 0.05 % lead. A protable high-purity germanium (HPGe) coaxial detector was used to measure the spectra of the induced nuclides of patient apertures. The analysis of the spectra and the identification of the radionuclides were preliminarily operated by the Nuclide Navigator III Master Library. On the basis of the results by Nuclide Navigator III Master Library, we manually selected the reliable nuclides by the gamma-ray energies, branching ratio, and half life. In the spectra, we can quantify the activity of radionuclides by the Monte Carlo efficiency transfer method. Results: In this study, the radioisotopes activated in patient apertures by the 190-MeV proton beam were divided into two categories. The first category is long half-life radionuclides, such as Co-56 (half life, 77.3 days). Other radionuclides of Cu-60, Cu-61, Cu-62, Cu-66, and Zn-62 have shorter half life. The radionuclide of Cu-60 had the highest activity. From calculation with the efficiency transfer method, the deviations between the computed results and the measured efficiencies were mostly within 10%. Conclusion: To identify the radionuclides and quantify the activity helps us to estimate proper time intervals for cooling the patient apertures. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

07 ISOTOPE AND RADIATION SOURCES↗

SLUDGE BATCH 7 ACCEPTANCE EVALUATION: RADIONUCLIDE CONCENTRATIONS IN TANK 51 SB7 QUALIFICATION SAMPLE PREPARED AT SRNL

Presented in this report are radionuclide concentrations required as part of the program of qualifying Sludge Batch Seven (SB7) for processing in the Defense Waste Processing Facility (DWPF). The SB7 material is currently in Tank 51 being washed and prepared for transfer to Tank 40. The acceptance evaluation needs to be completed prior to the transfer of the material in Tank 51 to Tank 40. The sludge slurry in Tank 40 has already been qualified for DWPF and is currently being processed as SB6. The radionuclide concentrations were measured or estimated in the Tank 51 SB7 Qualification Sample prepared at Savannah River National Laboratory (SRNL). This sample was prepared from the three liter qualification sample of Tank 51 sludge slurry (HTF-51-10-125) received on September 18, 2010. The sample was delivered to SRNL where it was initially characterized in the Shielded Cells. With consultation from the Liquid Waste Organization, the qualification sample was then modified by several washes and decants, which included addition of Pu from H Canyon and sodium nitrite per the Tank Farm corrosion control program. This final slurry now has a composition expected to be similar to that of the slurry in Tank 51 after final preparations have been made for transfer of that slurry to Tank 40. Determining the radionuclide concentrations in this Tank 51 SB7 Qualification Sample is part of the work requested in Technical Task Request (TTR) No. HLW-DWPF-TTR-2010-0031. The radionuclides included in this report are needed for the DWPF Radiological Program Evaluation, the DWPF Waste Acceptance Criteria (TSR/WAC) Evaluation, and the DWPF Solid Waste Characterization Program (TTR Task I.2). Radionuclides required to meet the Waste Acceptance Product Specifications (TTR Task III.2.) will be measured at a later date after the slurry from Tank 51 has been transferred to Tank 40. Then a sample of the as-processed SB7 will be taken and transferred to SRNL for measurement of these radionuclides. The results presented in this report are those necessary for DWPF to assess if the Tank 51 SB7 sample prepared at SRNL meets the requirements for the DWPF Radiological Program Evaluation, the DWPF Waste Acceptance Criteria evaluation, and the DWPF Solid Waste Characterization Program. Concentrations are given for thirty-four radionuclides along with total alpha and beta activity. Values for total gamma and total gamma plus beta activities are also calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater and Intruder Radionuclide Screening

Solid Waste Management (SWM) operates the E-Area Low-Level Waste Facility (ELLWF) where low level on-site and off-site solid waste streams are buried. The facility has been in operation since late 1994 and is currently projected to remain in operation until 2065. This facility can accommodate a broad range of waste forms resulting from the six different types of disposal unit options (i.e., varying degrees of engineered barriers → trenches to concrete vaults). This facility is currently operating under a Performance Assessment (PA) issued back in 2008, along with several subsequent supporting Special Analyses (SA). The Savannah River National Laboratory (SRNL) developed the prior PAs and SAs and has been tasked to update the facility’s PA. For operating the E-Area facility, a Waste Inventory Tracking System (e.g., WITS) is actively employed by waste generators where every radionuclide entering the facility (to be buried in one of its many disposal units) must be either directly or indirectly accounted for. Since there is a large number of radionuclides in existence (>3,000), the International Commission on Radiological Protection (ICRP-107) has provided guidance on the subset of radionuclides requiring further assessment in landfills such as the E-Area LLWF. The ICRP-107 publication provides critical radiological information on 1,252 radionuclides of 97 elements. This database is the critical starting point for developing a consistent inventory limit system. The explicit measurement and tracking of all radionuclides are not necessary when process knowledge, burial history, and radiological aspects are factored into conservative groundwater and intruder screening processes. Across the DOE complex these screening processes have been historically performed using the methodology suggested by the National Council on Radiation Protection and Measurements (NCRP) as presented in their original report (NCRP 1984) and then refined in a later report (NCRP 1996). In the recommended screening models employed within this report the traditional NCRP models are updated to better handle progeny and better reflect the known characteristics of E-Area. This improved screening process is referred to as the “NCRP-like” method. Various upgrades to the traditional NCRP methodology have been used by others (e.g., NRC funded effort by Kennedy and Strenge 1992). The more detailed models by Kennedy and Strenge (1992) were considered in this effort and are compared to the results from the more traditional NCRP-like models. The groundwater and inadvertent intruder screening analyses presented in this report start with this 1,252 radionuclide list and reduces it down to more manageable lists that are applicable to the various disposal unit types contained within E-Area. In order to reduce this starting list, some level of exposure risk must be considered acceptable. Historically, a dose (or concentration level) has been compared with a screening criterion set to 1% of a performance measure (e.g., a beta-gamma dose not to exceed the 4 mrem/yr beta-gamma performance measure x 0.01 = 0.04 mrem/yr). Thus, if a radionuclide produced a bounding or screening-level dose (or concentrations) less than the screening criterion, it could be safely removed from further consideration. Several tiers of screening and bounding level analyses have been considered in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

M4SF-20LL010302042: Process Model for Radionuclide Incorporation into Corrosion Products

This progress report (Level 4 Milestone Number M4SF-20LL010302042) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Crystalline Activity Number SF-20LL010302041. The research is focused on actinide and radionuclide sequestration in steel corrosion products. Fuel matrix degradation models suggest that the near field is likely to be reducing at the time of canister breaching, steel corrosion, and radionuclide release, but more oxidizing conditions may prevail in the far field. The incorporation of radionuclides into corrosion phases may limit the rate of radionuclide release by sequestering a portion of the radionuclide source term. For these reasons there is a need to evaluate the incorporation of Pu and other radionuclides into various Fe-oxide phases, and to understand the behavior of coprecipitated phases during mineral recrystallization processes and during re-oxidation events. Radionuclide coprecipitation with Fe minerals may impact long-term repository performance and is an ongoing research focus at Lawrence Livermore National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Groundwater and Intruder Radionuclide Screening

Solid Waste Management (SWM) operates the E-Area Low-Level Waste Facility (ELLWF) where low level on-site and off-site solid waste streams are buried. The facility has been in operation since late 1994 and is currently projected to remain in operation until 2065. This facility can accommodate a broad range of waste forms resulting from the six different types of disposal unit options (i.e., varying degrees of engineered barriers → trenches to concrete vaults). This facility is currently operating under a Performance Assessment (PA) issued back in 2008, along with several subsequent supporting Special Analyses (SA). The Savannah River National Laboratory (SRNL) developed the prior PAs and SAs and has been tasked to update the facility’s PA. For operating the E-Area facility, a Waste Inventory Tracking System (e.g., WITS) is actively employed by waste generators where every radionuclide entering the facility (to be buried in one of its many disposal units1) must be either directly or indirectly accounted for. Since there is a large number of radionuclides in existence (>3,000), the International Commission on Radiological Protection (ICRP-107) has provided guidance on the subset of radionuclides requiring further assessment in landfills such as the E-Area LLWF. The ICRP-107 publication provides critical radiological information on 1,252 radionuclides of 97 elements. This database is the critical starting point for developing a consistent inventory limit system. The explicit measurement and tracking of all 1,252 ICRP-107 radionuclides can be reduced when process knowledge, burial history, and radiological aspects are factored into conservative groundwater and intruder screening processes. Across the DOE complex these screening processes have been historically performed using the methodology suggested by the National Council on Radiation Protection and Measurements (NCRP) as presented in their original report (NCRP 1984) and then refined in a later report (NCRP 1996). In the recommended screening models employed within this report the traditional NCRP models are updated to better handle progeny and better reflect the known characteristics of E-Area. This improved screening process is referred to as the “NCRP-like” method. Various upgrades to the traditional NCRP methodology have been used by others (e.g., NRC funded effort by Kennedy and Strenge 1992). The more detailed models by Kennedy and Strenge (1992) were considered in this effort and are compared to the results from the more traditional NCRP-like models. The groundwater and inadvertent intruder screening analyses presented in this report start with this 1,252 radionuclide list and reduces it down to more manageable lists that are applicable to the various disposal unit types contained within E-Area. In order to reduce this starting list, some level of exposure risk must be considered acceptable. Historically, a dose (or concentration level) has been compared with a screening criterion set to 1% of a performance measure (e.g., a betagamma dose not to exceed the 4 mrem/yr beta-gamma performance measure x 0.01 = 0.04 mrem/yr). Thus, if a radionuclide produced a bounding or screening-level dose (or concentrations) less than the screening criterion, it could be safely removed from further consideration. Several tiers of screening and bounding level analyses have been considered in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗