Search NASA⌕ Search

SEARCH · Search NASA

Results for “REFUELING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Synthesis Roadmap for Actinide Chloride Salts

Molten salt reactors (MSRs) are among the main advanced nuclear reactor types at the forefront of development by industry, with the support of the US government, for the next fleet of nuclear reactors to support the demand for energy in the coming decades. MSRs are highly unique because they are cooled and typically also fueled by molten salt. This quality brings about safety benefits such as low-pressure operation and self-stabilization of the neutron flux, operational benefits such as high-temperature operation and the ability for online refueling, and fuel and waste management benefits thanks to the flexibility of post-processing of molten salts and reprocessing options that involve removal of fission products and actinide separation. In fact, domestic deployment of molten salt (or molten salt–cooled) reactors is an approaching reality: a handful of molten salt reactor developers are planning to operate demonstration-scale reactors, as a step toward commercial-scale power reactors, within the decade. For example, Natura Resources received a construction permit in September 2024 for the deployment of MSR-1, which is a graphite-moderated thermal spectrum reactor, at Abilene Christian University. Also, TerraPower, in a collaborative effort with Southern Company and Idaho National Laboratory (INL), received approval from DOE in 2023 to proceed with the construction of the Molten Chloride Reactor Experiment (MCRE), a homogeneous chloride fast reactor at INL, and has begun assembly of system components. There are several other examples of developers at different stages of development of their own unique MSR designs (Jenet et al., 2025). As developers are in the process of obtaining approvals for their designs, deploying demonstration-scale reactors, and planning for their commercial-scale power reactors, there is a critical supply chain need for the synthesis of fuel for these reactors that must be addressed. The challenge generally is three-fold: (1) the quantity of fueled salt needed for these reactors is extraordinarily high (>100s of kilograms), but demonstrations of scaled-up techniques for fueled salt synthesis are significantly more limited than demonstrations of lab-scale syntheses; (2) each developer has a unique reactor design, which means different actinide halide elements in different carrier salts must be synthesized; and (3) there is a need for particularly high-purity salt so as to ensure the long-term operability of these reactors with minimal degradation to salt-wetted components, which necessitates synthesis techniques with high levels of quality control, repeatability, and well-characterized precursor and reactant materials. It is crucial that this supply chain challenge be addressed by demonstrating synthesis techniques that are scalable, de-risked, and well-documented so that these technologies may be adopted and utilized by industry to support the fueling needs of MSRs that are to come online within the next 10 years. With this supply chain challenge clearly defined for the developing MSR industry, it is important to consider that addressing such a challenge is oftentimes complex and context-dependent. There is not necessarily a single synthesis technique that can be scaled up and adopted to address the needs of all MSR developers; the synthesis approach that may be viable for producing a desired fuel salt will be entirely dependent on the exact salt composition needed, the quantity needed, purity needed, the refueling and waste plans, and the availability of a carrier salt for the fuel. Therefore, it is important to consider more broadly what synthesis techniques are available and have been demonstrated to understand the benefits, challenges, and general nuances that should be considered when evaluating a particular route for efficient production of high-purity fuel salts at scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Marine Hydrogen Demonstration

This report summarizes Phase 1 of a project involving the design of a Floating Hydrogen Production and Dispensing Barge destined for the Port of San Francisco (SF). The H 2 Barge is designed to produce renewable H 2 at the rate of ~ 530 kg/day, storing 512 kg of hydrogen at 517-bar, allowing fast refueling of hydrogen fuel cell vessels and land-side hydrogen delivery trailers for distribution into the nascent SF hydrogen ecosystem. The broader considerations that impacted the H2 Barge design are also described. An account is given of a new review process formulated by the United States Coast Guard (USCG) to review this first-of-its-kind maritime implementation of hydrogen technology. The immediate goals of the H 2 Barge Project are to 1) demonstrate the feasibility, viability and methods of hydrogen production, storage and fueling in a maritime context, 2) help shape (where needed) and navigate the required local, state and federal regulatory gauntlet and 3) catalyze a “green hydrogen ecosystem” (both marine and landside) with locally produced renewable hydrogen at the San Francisco waterfront. A summary is also given of the modeling and experimental activity of Phase 1 directed to the development of science-based refueling protocols for large marine Type IV 250-bar hydrogen tanks. Combined modeling and experimental studies are reported of the filling of large (28 kg) 250-bar Type IV hydrogen tanks of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary question was to determine how such tanks can be successfully filled (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit historically set for such tanks. The studies show that a gas injector is needed avoid thermal stratification during filling which can result in potential hot spots. Pre-cooling of the hydrogen was found to be essential in most cases, as ambient conditions greatly affect the need for a pre-cooling to achieve the 45-minute fill time. Pre-cooling cannot be supplied by nearby water, such as that found in nature (bays, lakes, rivers, etc.) because pre-cooling cooling below 0 °C was found to be necessary to avoid excessive compression heating. The experimental results afforded a calibration of the engineering model (SOFIL) for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen filling temperatures to an accuracy of +/- 2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks of the type examined here.

08 HYDROGEN↗

Tools and Methods for Optimization of Nuclear Plant Outages

Refueling outages are one of the most challenging phases in a nuclear power plants (NPP) operating cycle. Refueling outages are extremely costly for a NPP due to the large amount of required resources and because of lost revenue due to plant being off the grid. Outage durations have steadily decreased across the industry over that last few decades primarily due to improved planning and coordination, but there are still many plants that struggle to meet the performance metrics accomplished by other utilities. Schedule resilience is one of the issues. NPP outages require scheduling thousands of activities in a duration of around 30 days on average. Outage staff begin working on the schedule more than a year ahead of the outage start and make every effort to build a robust schedule. Despite the robust and detailed planning, once the outage starts, numerous emergent issues typically appear along with schedule delays requiring continuous replanning and adjusting. When schedule disruption occurs during an outage, plant staff make urgent efforts to recover but often not able to maintain the planned outage duration. These outage delays can cost a utility several million dollars per day. Tools that could help outage schedulers create a more resilient schedule and allow them to optimally reschedule emergent work could significantly reduce outage delays. One key aspect of creating a resilient schedule is to have accurate estimates for activity duration. Another important outage scheduling capability is the ability to schedule emergent work with minimal disruption. The Optimization of Outage Activities project under the Risk-Informed Systems Analysis Pathway (RISA) sponsored by Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program focuses on developing tools and methods to support nuclear power plants with optimization of outage schedules. The goal of the outage optimization is the completion of all planned and emergent outage activities as fast as possible while maintaining highest level of safety. This report describes the initial development of tools to support outage management that leverage computational and machine learning methods developed in other RISA and LWRS projects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Resin to Reduce Silica in Borated Fluid - 20072

The Electric Power Research Institute (EPRI) strongly recommends the concentration of silica in the reactor coolant be limited, potential ingress be carefully controlled, and frequently monitored to assess potential silica deposits on fuel cladding surfaces. Boraflex is a product with silicone rubber encasing a neutron absorber for criticality control, and it was installed in the majority of nuclear power plant spent fuel pools. Over time and in the presence of radiation, the silicone rubber lining degrades into silica (SiO{sub 2}) and hydrogen gas. Silica is somewhat soluble in water and spent fuel pool water communicates with other plant systems during refueling outages, leading to a buildup of silica in the reactor coolant and connected systems. Due to the prevalence of Boraflex racks in spent fuel pools, the presence of silica is a chronic nuclear industry concern. To address this concern, many nuclear plants have installed reverse osmosis skid systems to remove the silica from their spent fuel pools and, by extension, from reactor coolant. These skids are expensive to install and maintain. Arcadis personnel demonstrated that an iron-impregnated resin could be used to remove silica from borated systems without impacting the water quality. The resin was readily available, inexpensive, and easy to install in existing plant equipment. During a nuclear power plant's refueling outage the iron-impregnated resin proved to be effective in reducing the need for feed and bleed operations, with concurrent cost savings and reduction in required outage water management activities. Thus, the following savings were realized: - Eliminated the need to purchase, install, and maintain a reverse osmosis system avoiding more than $10 million in up-front capital cost and ongoing operating and maintenance costs. - Removed 9.57 kilograms (21 pounds) of silica dioxide from the primary system fluid. - Reduced the volume of feed and bleed from 70,000 gallons (2.65 E+05 liters) to 35,000 gallons (1.32 E+05 liters). - Saved $380,000 in water production and disposal costs. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods and Tools To Assess Robustness of Nuclear Plant Outages

Refueling outages are one of the most challenging phases in a nuclear power plant (NPP) operating cycle. Refueling outages are extremely costly for an NPP due to the large amount of required resources and because of lost revenue due to plant being off the grid. Outage durations have steadily decreased across the industry over that last few decades primarily due to improved planning and coordination, but there are still many plants that struggle to meet the performance metrics accomplished by other utilities. Schedule resilience is one of the issues. NPP outages require scheduling thousands of activities within 30 days on average. Despite detailed planning, once the outage starts, numerous emergent issues typically appear along with schedule delays requiring continuous replanning and adjustment. When schedule disruption occurs during an outage, plant staff make urgent efforts to recover but are often not able to maintain the planned outage duration. These outage delays can cost a utility several million dollars per day. Tools that could help outage schedulers create a more resilient schedule and allow them to optimally reschedule emergent work could significantly reduce outage delays. One key aspect of creating a resilient schedule is to have accurate estimates for activity duration. Another important outage scheduling capability is the ability to schedule emergent work with minimal disruption. This paper focuses on developing tools and methods to support NPPs with outage schedule optimization and it describes the initial development of tools to support outage management that leverage computational and machine learning methods.

97 - MATHEMATICS AND COMPUTING↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Delivering Clean Air in Denver: Propane Trucks and Infrastructure in Mail Delivery Application

In 2021, Drive Clean Colorado, a Denver-based Clean Cities coalition, initiated the deployment of five Class 6 medium-duty propane autogas delivery trucks into a United States Postal Service (USPS) mail delivery contractor fleet with the goal of providing a proof-of-concept demonstration for mail delivery fleets nationwide. Funded by the U.S. Department of Energy's Office of Energy Efficiency & Renewable Energy, the project, titled "Delivering Clean Air in Denver: Propane Trucks and Infrastructure in Mail Delivery Application," enabled the purchase and deployment of the propane-powered trucks, refueling infrastructure, and supporting analysis by the National Renewable Energy Laboratory (NREL). Key objectives of the analysis included calculating the propane vehicles' emissions reductions, analyzing the costs and operational performance of the propane fleet compared to conventional diesel-powered vehicles, and evaluating the viability of propane as a clean and cost-effective alternative to conventional diesel trucks (AFDC 2023b, 2023c). The primary goal of the project was to demonstrate alternative fuel vehicles in a mail transport application and evaluate the viability of propane as a clean and cost-effective alternative to conventional diesel trucks. This proof-of-concept demonstration is expected to lead to improved understanding of the performance attributes, costs, and operational issues to inform technology adoption decisions, helping to spur market transformation toward lower-emission truck fleets. By reducing the risk of first adoption, potential exists to transform the U.S. Postal Service (USPS) mail delivery system into a lower-carbon national fleet. This technical report details the vehicle duty cycle characterization and fleet cost and performance comparison performed by the National Renewable Energy Laboratory, in addition to estimated emissions reductions for delivery operations.

33 ADVANCED PROPULSION SYSTEMS↗

Levelized Cost of Dispensed Hydrogen for Heavy-Duty Vehicles

In this short technical report, we explore the range of levelized costs of dispensed hydrogen (H2) from hydrogen refueling (or fueling) stations (HRS) for H2 heavy-duty fuel cell electric vehicles (FCEVs) that are feasible in the 2030 timeframe. We explore different scenarios by varying hydrogen delivery distances, HRS sizes, HRS utilization rates, and economies of scale in the Hydrogen Delivery Scenario Analysis Model (HDSAM). Thus, we observe how the contribution to the levelized cost of each supply chain component changes.

30 DIRECT ENERGY CONVERSION↗

Next Generation Hydrogen Station Analysis

This presentation was part of the U.S. Department of Energy Hydrogen Program's Annual Merit Review and Peer Evaluation Meeting, reporting on project TA042, hydrogen refueling station evaluation.

CDP↗

Modeling a Thermal-Spectrum LEU-fueled Molten Salt Reactor Co-fueled with Thorium in SCALE 6.3.1 and Serpent-2

Interest in the development of advanced nuclear fission reactors for commercial electricity production has risen in recent years, with Generation IV reactor designs offering numerous advantages in safety, efficiency, fuel cycle sustainability, and waste management. In particular, thorium-fueled molten salt reactors (MSRs) are considerably promising for enhancing fuel cycle sustainability in their ability to breed fissile 233U fuel from thorium, a presently untapped and widely abundant resource. A novel MSR fuel cycle concept, the ”Sourdough” refueling and waste management strategy, has previously been demonstrated with a traditional uranium-based fuel cycle in a thermal-spectrum MSR operating with low enriched uranium (LEU) fuel with favorable neutronic performance. However, the ability to use this unique fuel cycle approach with thorium-based molten salt fuels has not yet been studied. In this work, the Sourdough fuel cycle was implemented in a small, thermal-spectrum MSR fueled with high assay low enriched uranium (HALEU) and fertile 232Th for breeding 233U fuel. Relevant neutronic data, including fuel and isothermal temperature feedback behavior, was studied using the SCALE 6.3.1 and Serpent-2 code systems, and keff data was measured during simulated depletion at 400 MWth. The Sourdough fuel cycle concept is shown to perform favorably with a thorium-fueled MSR model, thus warranting further study into its use in other MSR designs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Designing Electrolytes With Controlled Solvation Structure for Fast‐Charging Lithium‐Ion Batteries

Recharging battery-powered electric vehicles (EVs) in a similar timeframe as those used for refueling gas-powered internal combustion vehicles is highly desirable for rapid penetration of the EV market. It is well known that the electrolyte in a battery plays a critical role in fast-charging capability of the battery because it determines the rate of ion transport together with its derived electrode/electrolyte interphases on both cathode and anode of the battery. In this study, the effects of contents of salt, coordinating solvent, and noncoordinating diluent on salt dissociation degree and electrolyte ionic conductivity are investigated, and a controlled solvation structure electrolyte is developed to improve the lithium ion mobility and conductivity in the electrolyte and to enhance the kinetics and stability of the electrode/electrolyte interphases in the battery. This electrolyte enables fast-charging capability of high energy density lithium-ion batteries (LIBs) at up to 5 C rate (12-min charging), which significantly outperforms the state-of-the-art electrolyte. The controlled solvation structure sheds light on the future electrolyte design for fast-charging LIBs.

25 ENERGY STORAGE↗

Strategies for thorium fuel cycle transition in the SD-TMSR

Liquid-fueled Molten Salt Reactor (MSR) systems represent advances in safety, economics, and sustainability. The MSR has been designed to operate with a Th/ 233 U fuel cycle with 233 U used as startup fissile material. Since 233 U does not exist in nature, we must examine other available fissile materials to start up these reactor concepts. This work investigates the fuel cycle and neutronics performance of the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR) with different fissile material loadings at startup: High Assay Low Enriched Uranium (HALEU) (19.79%), Pu mixed with HALEU (19.79%), reactor-grade Pu (a mixture of Pu isotopes chemically extracted from Pressurized Water Reactor (PWR) spent nuclear fuel (SNF) with 33 GW d/tHM burnup), transuranic elements (TRU) from Light Water Reactor (LWR) SNF, and 233 U. The MSR burnup routine provided by SERPENT-2 is used to simulate the online reprocessing and refueling in the SD-TMSR. The effective multiplication factor, fuel salt composition evolution, and net production of 233 U are studied in the present work. Additionally, the neutron spectrum shift during the reactor operation is calculated. The results show that the continuous flow of reactorgrade Pu helps transition to the thorium fuel cycle within a relatively short time (≈ 4.5 years) compared to 26 years for 233 U startup fuel. Finally, using TRU as the initial fuel materials offers the possibility of operating the SD-TMSR for an extended period of time (≈ 40 years) without any external feed of 233 U.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conceptual core design of the molten metal fueled microreactor with self-regulating capability

The microreactor concept has received significant attention in the United States for its lower capital investment, siting flexibility and high mobility. A microreactor aims to provide reliable electricity in remote communities, mining areas, or isolated islands, which will save the high fuel transportation cost. Thus, minimizing the staff level for operating and maintaining a microreactor is desirable. The objective of the study is to design a self-regulated Molten Metal fueled microReactor core (MMR) and to demonstrate the self-regulating capability of the MMR core. The control of the reactor is solely relying on reactivity feedbacks from fuel temperature perturbation. Molten UMn (liquid form at the temperature over 720°C) was utilized as the fuel material in MMR due to the larger thermal expansion coefficient compared to the conventional solid fuel. The MMR core has a fast neutron spectrum, which corresponds to a small burnup reactivity swing. The core design parameters were selected based on DAKOTA, REBUS, and ANLHTP calculations. The MMR is designed to run for 10 years at a power level of 15 MWth. Furthermore, no refueling is needed during the reactor lifetime. The system dynamic analyses were performed, and it was found that the reactor can be self-regulating within a temperature range of 800 ± 80°C for a loss of heat sink transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-fidelity simulations of the run-in process for a pebble-bed reactor

Pebble-bed reactors (PBRs) rely on a continual feed of fuel pebbles being cycled through the core. As a result, they require a “run-in” period in order to reach an equilibrium state. The run-in period for a PBR is a complex, time-dependent problem that requires the injection of new fuel, different types of fuel, and power increases. This complexity in the run-in makes it important to capture the physical processes in order to generate an accurate representation. The present work details the creation of a high-fidelity Monte Carlo methodology for analyzing the run-in and subsequent approach to equilibrium for PBRs. The methodology entails a Python module wrapped around Serpent so as to perform neutronics calculations, move pebbles, refuel the core, and discharge pebbles, thereby modeling the explicit behavior of the PBR run-in. Further, three run-in simulations (a constant temperature profile, a linear temperature profile, and a constant temperature profile using control rods) were examined in order to identify the key physical phenomena present in the run-in process. Utilizing kugelpy, we found the inclusion of a temperature profile to be important for accurately capturing a discharge burnup (around 141 MWd/kg), a consistent k-eff (around 1.005), and an average pebble power (around 2.5 kW/pebble) that all fall within acceptable limits.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗