Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA's Next Generation Optical Communications Relay

NASA's Space Communications and Navigation (SCaN) program is creating an operational optical communications network to complement its current radio frequency (RF) networks. NASA is currently planning for a new optical communications relay node in geostationary (GEO) orbit to be commissioned in 2025, developed by NASA's Goddard Space Flight Center (GSFC), as evolved from Goddard's Laser Communications Relay Demonstration (LCRD) GEO relay payload that will launch in 2019. The Next Generation optical relay node will serve as an initial element in a larger optical networking constellation that will consist of Government and commercial, and international relays. NASA's nodes will aggregate traffic at data rates of up to 10 Gigabits per second (Gbps) from users on the Earth's surface and up through suborbital, LEO, MEO, GEO, cislunar and even out to Earth-Sun Lagrange (1.25 Mkm) distances. Users that require low-latency will be serviced with an onboard complementary Ka-band downlink service. The next generation network will deploy > 100 Gbps space-to-ground links and also optical crosslinks between nodes to allow for user traffic backhaul to minimize ground station location constraints.

Israel, David↗

Proximity Link Design and Performance Options for a Mars Areostationary Relay Satellite

Current and near-term Mars relay telecommunications services are provided by a set of NASA and ESA Mars science orbiters equipped with UHF relay communication payloads employing operationally simple low gain antennas. These have been extremely successful in supporting a series of landed Mars mission, greatly increasing data return relative to direct-to-Earth lander links. Yet their relay services are fundamentally constrained by the short contact times available from the selected science orbits. Future Mars areostationary orbiters, flying in circular, equatorial, 1- sol orbits, offer the potential for continuous coverage of Mars landers and rovers, radically changing the relay support paradigm. Achieving high rates on the longer slant ranges to areostationary altitude will require steered, high-gain links. Both RF and optical options exist for achieving data rates in excess of 100 Mb/s. Several point designs offer a measure of potential user burden, in terms of mass, volume, power, and pointing requirements for user relay payloads, as a function of desired proximity link performance.

telecommunications↗

NASA's Next Generation ≥100 Gbps Optical Communications Relay

NASA’s Space Communications and Navigation (SCaN) program is creating an operational optical communications network to complement its current radio frequency (RF) networks. NASA is currently planning for a new optical communications relay node in geostationary (GEO) orbit to be commissioned in 2025, developed by NASA’s Goddard Space Flight Center (GSFC), as evolved from Goddard’s Laser Communications Relay Demonstration (LCRD) GEO relay payload that will launch in 2019. The Next Generation optical relay node will serve as an initial element in a larger optical networking constellation that will consist of Government and commercial, and international relays. NASA’s nodes will aggregate traffic at data rates of up to 10 Gigabits per second (Gbps) from users on the Earth’s surface and up through suborbital, LEO, MEO, GEO, cislunar and even out to Earth-Sun Lagrange (1.25 Mkm) distances. Users that require low-latency will be serviced with an onboard complementary Ka-band downlink service. The next generation network will deploy ≥ 100 Gbps space-to-ground links and also optical crosslinks between nodes to allow for user traffic backhaul to minimize ground station location constraints.

Park, Elizabeth A.↗

Assessment of Potential Mars Relay Network Enhancements

In anticipation of increased demands on Mars relay services, including planned arrivals of NASA’s InSight Lander in November 2018, and of NASA’s Mars 2020 rover and ESA’s ExoMars Rover & Surface Platform mission in Feb-Mar.2021, we have assessed a number of potential modifications and upgrades to Mars relay orbiters and quantified their impacts in terms of key relay support metrics, to support NASA and ESA programmatic decisions. Specific areas of investigation include: 1) implementation of “split-pass” relay capability for support to collocated landers, 2) modifications of the extended mission orbit for the Mars Atmosphere and Volatile EvolutioN Mission (MAVEN), and 3) introduction of Low-Density Parity Check (LDPC) coding. We report here on each of these potential upgrades, quantify the performance implications each would have on future Mars relay services in the context of future mission support scenarios, and provide a status on implementation.

Wenkert, Daniel↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Impact Analysis of High-Altitude Electromagnetic Pulse Coupling Effects on Power Grid Protection Relays

Protection relays are important equipment used for protection, control, and metering functions in the power grid. These relays are used to protect critical and difficult-to-replace equipment, like generators, transformers, and capacitor banks. Once the protection devices are disturbed or damaged, a high risk of power generation interruption occurs. Therefore, it is important and necessary to study the relay’s immunity to electromagnetic pulse (EMP) events. As a preliminary step toward empirical experimentation on actual equipment, this manuscript outlines an economical and efficient methodology for evaluating the impact of an EMP. An impedance measurement strategy was employed to model the equipment, setting the stage for subsequent immunity analyses. These analyses included the pulse current injection (PCI) method, which utilized an injecting probe to introduce the transient, and frequency domain electromagnetic (FEKO) simulation, which integrated electromagnetic coupling effects into the transient simulation. The impedance measurement and simulation results in this paper provide a reliable basis for gauging equipment performance in the face of HEMP threats. The results obtained using the PCI and FEKO simulations demonstrated the performance of different port responses under a high-altitude EMP, indicating the requirement for some protection to ensure the reliable operation of relays.

42 ENGINEERING↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

Impact of Geomagnetic Induced Current Neutral Blocking Devices on Distance Relays in Sub-transmission Networks with IBR

Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.

Patel, Trupal R [Sandia National Laboratories (SNL↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on differential protection which utilizes peer to peer communication between substations to determine if the current is not equivalent. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for such a widely implemented technology. For differential protection a GPS resilient architecture was implemented and tested for differential protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for differential protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How Inverter-Based Resources (IBRs) Affect Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.

14 SOLAR ENERGY↗

Magnetoresistor monitors relay performance

Magnetoresistor monitors the action of relays without disturbing circuit parameters or degrading relay performance. The magnetoresistor measures the relay magnetic flux produced under transient conditions to establish the characteristic signature of the relay.

Krebs, D. Q.↗

The Lunar Communications Relay Unit system design

Lunar Surface Exploration by Early Apollo Astronauts was limited by the range capabilities and configuration of the surface communications. To permit greater scientific yield from manned lunar exploration, it was necessary to provide improvements in crew mobility plus communications compatible with extended extravehicular activity. Expansion of EVA** and video communications capability was constrained by the requirement of interfacing with existing earth and lunar surface facilities, vehicle payload requirements, and crew operational considerations. Various trade-off s were conducted to permit rapid development of a feasible communication’s system which are described herein. The revision of the EVA mission profile necessitated establishment of new signal design parameters compatible with mobile and fixed site relay configurations. The design approach selected required strict discipline to enable integration of the electrical, mechanical, thermal and human factor fields. The resultant design of the Lunar Communications Relay Unit is a portable communications package to provide relay-to-earth of voice, data and color television from lunar surface locations far beyond the LM landing site and relay of ground voice to the EVA crew.

B. Trachtenberg↗

The Role of Remotely Sensed and Relayed Data in the Delaware River Basin

The planned integration of the existing water quality monitoring and data processing systems in the Delaware River Basin with a data relay experiment proposed for the ERTS-1 is discussed. The experiment is designed to use ERTS-1 as a data relay link for a maximum of 20 hydrologic stations in the basin, including stream gaging, reservoir level, ground water level, and water quality monitoring stations. This experiment has the potential for reducing the time lag between data collection and dissemination to less than 12 hours. The experiment will also provide impetus to develop an operational system of real time data processing and dissemination to handle the large quantity of data that will be obtained from the stations in the basin. The results of this experiment will demonstrate the relative merits of satellite relay of data versus conventional means of data telemetry and will provide a basis for the development of operational satellite relay of hydrologic data.

Paulson, R. W.↗

A method for compensating on-off relay control systems

A method is proposed for adjusting the characteristics of an on-off relay or contactor servomechanism to make it behave as a positive hysteresis relay intended to stabilize a control system. In this method, the nonlinear portion of the system, instead of the linear portion, is shaped by adding a positive hysteresis circuit to the system. A servomotor system using a typical relay for position control is studied as an application of the proposed method. It is shown that since the synthesis is mainly to improve the nonlinear characteristics of the on-off relay, the method will not affect the characteristics of other elements in the system, which is indispensable to the control of space vehicles.

Thompson, Z.↗

Orbit determination with the tracking data relay satellite system

The possibility of employing the tracking data relay satellite system to satisfy the orbit determination demands of future applications missions is investigated. It is shown that when the relay satellites are continuously and independently tracked from ground stations it is possible, using six hour data arcs, to recover user satellite state with an average error of about 25 m radially, 260 m along track, and 20 m cross track. For this arc length, range sum data and range sum rate data are equally useful in determining orbits. For shorter arc lengths (20 min), range sum rate data is more useful than range sum data. When relay satellites are not continuously tracked, user satellite state can be recovered with an average error of about 140 m radially, 515 m along track, and 110 m cross track. These results indicate that the TDRS system can be employed to satisfy the orbit determination demands of applications missions, such as the MAGSAT and potential gradiometer missions, provided the relay satellites are continuously and independently tracked.

Argentiero, P.↗

Scheduler software for tracking and data relay satellite system loading analysis: User manual and programmer guide

A user guide and programmer documentation is provided for a system of PRIME 400 minicomputer programs. The system was designed to support loading analyses on the Tracking Data Relay Satellite System (TDRSS). The system is a scheduler for various types of data relays (including tape recorder dumps and real time relays) from orbiting payloads to the TDRSS. Several model options are available to statistically generate data relay requirements. TDRSS time lines (representing resources available for scheduling) and payload/TDRSS acquisition and loss of sight time lines are input to the scheduler from disk. Tabulated output from the interactive system includes a summary of the scheduler activities over time intervals specified by the user and overall summary of scheduler input and output information. A history file, which records every event generated by the scheduler, is written to disk to allow further scheduling on remaining resources and to provide data for graphic displays or additional statistical analysis.

Craft, R.↗

Latching-Relay Driver And Continuity Checker

Driving circuit and associated continuity-checking circuit enable use of latching relay switch instead of non-latching relay switch in 120-Vdc power-distribution system. Average power consumed reduced by about 15 W. Latching-relay driver and continuity checker provides automatic turnoff relay when power fails, or alarm indicating discontinuity in turn-off circuit, respectively.

Kachelski, Thomas A.↗