Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL SECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Installed Cost Benchmarks and Deployment Barriers for Residential Solar Photovoltaics with Energy Storage: Q1 2016

In this report, we fill a gap in the existing knowledge about PV-plus-storage system costs and value by providing detailed component- and system-level installed cost benchmarks for residential systems. We also examine other barriers to increased deployment of PV-plus-storage systems in the residential sector. The results are meant to help technology manufacturers, installers, and other stakeholders identify cost-reduction opportunities and inform decision makers about regulatory, policy, and market characteristics that impede solar plus storage deployment. In addition, our periodic cost benchmarks will document progress in cost reductions over time. To analyze costs for PV-plus-storage systems deployed in the first quarter of 2016, we adapt the National Renewable Energy Laboratory's component- and system-level cost-modeling methods for standalone PV. In general, we attempt to model best-in-class installation techniques and business operations from an installed-cost perspective. In addition to our original analysis, model development, and review of published literature, we derive inputs for our model and validate our draft results via interviews with industry and subject-matter experts. One challenge to analyzing the costs of PV-plus-storage systems is choosing an appropriate cost metric. Unlike standalone PV, energy storage lacks universally accepted cost metrics, such as dollars per watt of installed capacity and lifetime levelized cost of energy. We explain the difficulty of arriving at a standard approach for reporting storage costs and then provide the rationale for using the total installed costs of a standard PV-plus-storage system as our primary metric, rather than using a system-size-normalized metric.

14 SOLAR ENERGY↗

The Energy Modeling Forum (EMF)-30 Study on Short-Lived Climate Forcers: Introduction and Overview

The Energy Modeling Forum (EMF)-30 inter-comparison study on short-lived climate forcers (SLCFs) focuses on black carbon (BC) and methane, two of the most important warming SLCFs. The potential impact on climate change of methane and BC-focused emission reductions in the transport and residential sectors were quantified using nine integrated assessment models and a simple climate model. These SLCF reductions reduced global temperatures by 0.18–0.26 °C in 2050 across the models for central climate parameters, with methane being the dominant contributor. The incremental impact of SLCF-focused reductions is much smaller when combined with a broader climate policy. Individual modeling groups examined the health benefits of air pollutant reductions, climate policy co-benefits, and quantified market impacts from air pollutant damages. Model structure and set-up impact on results are discussed along with areas for future work.

Smith, Steven J.↗

Life cycle impact assessment of home energy management systems (HEMS) using dynamic emissions factors for electricity in Finland

Decarbonising the European economy is a long-term goal in which the residential sector will play a significant role. Smart buildings for energy management are one means of decarbonisation, by reducing energy consumption and related emissions. This study investigated the environmental impacts of smart house automation using life cycle impact assessment. The ReCiPe method was selected for use, in combination with dynamic emissions factors for electricity in Finland. The results indicated that a high level of technology deployment may be counter-effective, due to high electricity consumption by the sensor network, automation system and computing devices. The results also indicated that number of inhabitants per household directly affected the environmental impacts of home automation. A single-person household saw its environmental impacts increase by 15%, while those of a five-person household increased by 3% in the worst-case scenario. The manufacturing phase contributed the major share of environmental impacts, exceeding the use phase in multiple categories. These findings indicate that finding the sweet spot in which technology can promote decarbonisation will be crucial to achieving the goal of a low‑carbon economy. - Highlights: •HEMS did not reduce the overall environmental impact of households. •Environmental impacts of HEMS are greater for single inhabitant households. •Energy efficiency of sensing devices must drastically increase to promote decarbonisation. •The highest life cycle environmental impacts of electronics are during the manufacturing phase. •Raising awareness is a critical part in decreasing the environmental impact of households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing electrification readiness in U.S. single-family homes based on a nationwide survey of electrical panel capacities

Electrification of residential buildings is a key strategy for increasing the use of renewable energy sources. Central to this transition is understanding the capacity of existing electrical infrastructure—specifically electrical panels—to safely and effectively manage increased electricity demands from electrification technologies. However, comprehensive nationwide data on electrical panel capacities in U.S. single-family homes is currently lacking. To address this gap, we conducted a nationwide survey of single-family homes, collecting detailed data on electrical panel capacities, breaker slot availability, major electric and gas appliances, electrical panel models, and home characteristics such as construction year and floor area. Photographic documentation was used to verify electrical panel data and appliance information. Results show that approximately 60% of surveyed homes have electrical panels rated at ≥200 amperes (A), indicating that a significant portion of the existing housing stock can accommodate additional electric loads. However, 31% of homes possess panels rated at ≤100 A, potentially restricting their ability to adopt new electric appliances without significant upgrades. Panel capacities positively correlate with both home size and construction year, with newer and larger homes generally better suited for electrification. Homes with higher-capacity panels tend to have fewer gas appliances, reflecting a gradual shift toward electric technologies. Conversely, homes with lower-capacity panels frequently rely on multiple gas appliances, highlighting substantial electrification challenges. Additionally, approximately 3% of surveyed homes had potentially hazardous electrical panel models, emphasizing important safety considerations in the residential electrification process. Our findings underscore the need for targeted policies, financial incentives, and infrastructure investments designed specifically to address infrastructural and safety barriers, particularly in older and smaller homes, to support equitable and efficient electrification across the U.S. residential sector.

Gul, Sadia↗

Spatial and temporal characterization of municipal solid waste based on resource recovery pathways

This study presents a two-year, quarterly assessment of MSW across four source sectors (residential, schools, restaurants, and grocery stores) from sixteen sites across five U.S. states. MSW was manually sorted into 27 categories and aggregated into pathway fractions: high-moisture (HM) organics, low-moisture (LM) organics, recyclable (RC) materials, and residuals for disposal. Organics represented 89 % of the MSW stream. The largest fraction was HM organics consisting of food waste (31 %) and yard waste (3 %), with large coefficient of variations (CV), 79 and 278 %, respectively, reflecting high seasonal and site variability that varied significantly (p < 0.01) across sampling periods. The HM fraction showed properties favorable for anaerobic digestion, with moisture content ranging from 56 to 95 % and volatile solids ranges of 86-95 %. In contrast, the LM and RC fractions remained more stable (plastics CV = 41 %; paper CV = 53 %) with heating values up to 26.9 MJ/kg across sources, reflecting suitability for gasification. Microstructural analysis revealed less porosity in residential waste sampled at the landfill, which can influence preprocessing efficiency and microbial accessibility. Pathway informed allocations showed that 35 % of MSW is suitable for anaerobic digestion, 36 % for gasification, and 18 % for recycling, leaving 11 % requiring landfill disposal. These results provide quantitative evidence to determine feedstock allocation, waste-to-energy system design, and the development of data-driven sustainability and resource recovery strategies within a circular bioeconomy.

09 BIOMASS FUELS↗

Residential green power demand in the United States

This paper investigates the demand determinants of green power in the U.S. residential sector. The data employed were collected by the National Renewable Energy Laboratory and consist of a cross-section of seven utilities observed over 13 years. A series of tests are performed that resulted in estimating a demand equation using the one-way cross-section random effects model. As expected, we find that demand is highly price inelastic. More interestingly though, is that elasticity with respect to number of customers is 0.52 leading to the conclusion that new subscribers tend to purchase less green power on average than the existing customers. Another compelling finding is that obtaining accreditation will have a 28.5% positive impact on consumption. Knowing that gaining green accreditation is important to the success of programs, utilities may want to seek certification and highlight it in their advertising campaigns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Connecting the resource nexus to basic urban service provision – with a focus on water-energy interactions in New York City

Urban water and energy systems are crucial for sustainably meeting basic service demands in cities. Therefore, this paper proposes and applies a technology-independent “reference resource-to-service system” framework for concurrent evaluation of urban water and energy system interventions and their ‘nexus’ or ‘interlinkages’. In a concrete application, data that approximate New York City conditions are used to evaluate a limited set of interventions in the residential sector, spanning from low-flow toilet shifts to extensive green roof installations. Results indicate that interventions motivated primarily by water management goals can considerably reduce energy use and contribute to mitigation of greenhouse gas emissions. Similarly, energy efficiency interventions can considerably reduce water use in addition to lowering emissions. However, interventions yielding the greatest reductions in energy use and emissions are not necessarily the most water conserving ones, and vice versa. Useful further research, expanding the present analysis should consider a broader set of resource interactions, towards a full climate, land, energy and water (CLEW) nexus approach. Overall, assessing the impacts, trade-offs and co-benefits from interventions in one urban resource system on others also holds promise as support for increased resource efficiency through integrated decision making.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large scale energy analysis and renovation strategies for social housing in the historic city of Venice

Social houses built after the Second World War to accommodate workers and low-income families represent one of the major energy consumers and greenhouse gas emitters in the residential sector. Plans for their renovation are underway in all European countries, and the process is more complicated for Italian cities due to the lack of space and the large number of historical buildings. This study addresses this challenge by proposing a methodology to renovate a low-income district in the city of Venice using CityBES to model and evaluate energy conservation measures. CityBES is a web-based tool that allows users to employ urban building energy modeling for large-scale energy and retrofit analyses of building stocks. In the case study conducted for Venice's Santa Marta district, due to the particular context, four common energy conservation measures covering both the building envelope and heat generation boilers have been applied. The evaluation of energy-saving performances at the district level showed that the four measures together achieved 67% energy savings, an abatement in energy cost equal to 67%, and annual carbon dioxide emissions reduction of 1.1 MtCO 2 . Furthermore, the case study demonstrates a method and workflow replicable for energy retrofit analysis of building stocks in other historical districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forecasting residential solar photovoltaic deployment in California

Residential distributed photovoltaic (PV) deployment in the United States has experienced robust growth, and policy changes impacting the value of solar are likely to occur at the federal and state levels. To establish a credible baseline and evaluate impacts of potential new policies, this analysis employs multiple methods to forecast residential PV deployment in California, including a time-series forecasting model, a threshold heterogeneity diffusion model, a Bass diffusion model, and National Renewable Energy Laboratory's dSolar model. As a baseline, the residential PV market in California is modeled to peak in the early 2020s, with a peak annual installation of 1.5-2 GW across models. We then use the baseline results from the dSolar model and the threshold model to gauge the impact of the recent federal investment tax credit (ITC) extension, the newly approved California net energy metering (NEM) policy, and a hypothetical value-of-solar (VOS) compensation scheme. We find that the recent ITC extension may increase annual PV installations by 12%-18% (roughly 500 MW, MW) for the California residential sector in 2019-2020. The new NEM policy only has a negligible effect in California due to the relatively small new charges (< 100 MW in 2019-2020). Moreover, impacts of the VOS compensation scheme (0.12 cents per kilowatt-hour) are larger, reducing annual PV adoption by 32% (or 900-1300 MW) in 2019-2020.

14 SOLAR ENERGY↗

Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Source Contributions to Fine Particulate Matter and Attributable Mortality in India and the Surrounding Region

Fine particulate matter (PM 2.5 ) is a leading mortality risk factor in India and the surrounding region of South Asia. This study evaluates the contribution of emission sectors and fuels to PM 2.5 mass for 29 states in India and 6 surrounding countries (Pakistan, Bangladesh, Nepal, Bhutan, Sri Lanka, and Myanmar) by combining source-specific emission estimates, stretched grid simulations from a chemical transport model, high resolution hybrid PM 2.5 , and disease-specific mortality estimates. We find that 1.02 (95% Confidence Interval (CI): 0.78-1.26) million deaths in South Asia attributable to ambient PM 2.5 in 2019 were primarily from three leading sectors: residential combustion (28%), industry (15%), and power generation (12%). Solid biofuel is the leading combustible fuel contributing to the PM 2.5 -attributable mortality (31%), followed by coal (17%), and oil and gas (14%). State-level analyses reveal higher residential combustion contributions (35%-39%) in states (Delhi, Uttar-Pradesh, Haryana) with high ambient PM 2.5 (>95 µg/m 3 ). The combined mortality burden associated with residential combustion (ambient) and household air pollution (HAP) in India is 0.72 million (95% CI:0.54-0.89) (68% attributable to HAP, 32% attributable to residential combustion). Our results illustrate the potential to reduce PM 2.5 mass and improve population health by reducing emissions from traditional energy sources across multiple sources in South Asia.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Electricity consumption variation versus economic structure during COVID-19 on metropolitan statistical areas in the US

The outbreak of novel coronavirus disease (COVID-19) has resulted in changes in productivity and daily life patterns, and as a result electricity consumption (EC) has also shifted. In this paper, we construct estimates of EC changes at the metropolitan level across the continental U.S., including total EC and residential EC during the initial two months of the pandemic. The total and residential data on the state level were broken down into the county level, and then metropolitan level EC estimates were aggregated from the counties included in each metropolitan statistical area (MSA). This work shows that the reduction in total EC is related to the shares of certain industries in an MSA, whereas regardless of the incidence level or economic structure, the residential sector shows a trend of increasing EC across the continental U.S. Since the MSAs account for 86% of the total population and 87% of the total EC of the continental U.S., the analytical result in this paper can provide important guidelines for future social-economic crises.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Global Building Occupant Behavior Database

This paper introduces a database of 34 field-measured building occupant behavior datasets collected from 15 countries and 39 institutions across 10 climatic zones covering various building types in both commercial and residential sectors. This is a comprehensive global database about building occupant behavior. The database includes occupancy patterns (i.e., presence and people count) and occupant behaviors (i.e., interactions with devices, equipment, and technical systems in buildings). Brick schema models were developed to represent sensor and room metadata information. The database is publicly available, and a website was created for the public to access, query, and download specific datasets or the whole database interactively. The database can help to advance the knowledge and understanding of realistic occupancy patterns and human-building interactions with building systems (e.g., light switching, set-point changes on thermostats, fans on/off, etc.) and envelopes (e.g., window opening/closing). With these more realistic inputs of occupants’ schedules and their interactions with buildings and systems, building designers, energy modelers, and consultants can improve the accuracy of building energy simulation and building load forecasting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Day-ahead continuous double auction-based peer-to-peer energy trading platform incorporating trading losses and network utilisation fee

Integration of distributed energy resources, such as photovoltaic solar (PV), introduces new opportunities to establish local energy market frameworks to improve renewable energy utilisation in residential sectors. Such peer-to-peer (P2P) energy trading refers to a local market structure where customers (and prosumers) interact to share excess PV generation to enhance the individual and community social welfare. In this work, a day-ahead continuous double auction (CDA)-based P2P market structure considering network losses and network utilisation fees was designed. Day-ahead PV energy is modelled using fractional integral polynomials and the output is forecasted using an autoregressive integrated moving average model for each market interval. Based on the customer load and excess PV energy, the CDA market is cleared using a bid/ask matching mechanism. The performance of the P2P market was evaluated by computing different welfare metrics while analysing the effect of network constraints. The results show that the designed CDA-based P2P market structure increases the social welfare of all participants by an average of 17.75% compared to the baseline for the presented cases. Moreover, the impact of the forecasting error between the day-ahead and real-time market was also quantified.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Searching for Suitable Binary Fluid for an Ejector Heat Pump for Domestic Water Heating

Water heating is a major source of energy consumption in the U.S. residential sector. Heat pumps can significantly increase the energy efficiency of water heating. An ejector heat pump (EHP) is a novel, thermally driven heat pump that uses an ejector as a thermocompressor. Choosing suitable working fluids is critical in developing high-performance EHPs. Therefore, this research screens binary fluid pairs (BFPs) for EHPs to produce domestic hot water at a high coefficient of performance (COP). The criteria for screening BFP candidates for EHP water heaters (EHPWHs) are established, and BFP candidates are shortlisted. This study identifies HFE7000, Novec649, HFE7100, HFE7200, and HFE7500 for the primary fluids and RE170, R600a, R600, and R1234ze(Z) for the secondary fluids. The thermodynamic model is employed to investigate the performance of EHPWHs using the shortlisted BFPs under various operating parameters, including the evaporation pressure of the primary working fluid in the high-temperature evaporator and the condensation temperature. In conclusion, the highest heating-cycle COP of 1.328 is achieved by an EHPWH operating with HFE7000/R600 at a condenser temperature of 50 °C and a pressure of 1.69 MPa in the high-temperature evaporator.

42 ENGINEERING↗

Updated U.S. Low-Temperature Heating and Cooling Demand by County and Sector

This dataset includes U.S. low-temperature heating and cooling demand at the county level in major end-use sectors: residential, commercial, manufacturing, agricultural, and data centers. Census division-level end-use energy consumption, expenditure, and commissioned power database were dis-aggregated to the county level. The county-level database was incorporated with climate zone, numbers of housing units and farms, farm size, and coefficient of performance (COP) for heating and cooling demand analysis. This dataset also includes a paper containing a full explanation of the methodologies used and maps. Residential data were updated from the latest Residential Energy Consumption Survey (RECS) dataset (2015) using 2020 census data. Commercial data were baselined off the latest Commercial Building Energy Consumption Survey (CBECS) dataset (2012). Manufacturing data were baselined off the latest Manufacturing Energy Consumption Survey (MECS) dataset (2021).

15 GEOTHERMAL ENERGY↗

On the Inclusion of Energy-Shifting Demand Response in Production Cost Models: Methodology and a Case Study

In the context of future power system requirements for additional flexibility, demand response (DR) is an attractive potential resource. Its proponents widely laud its prospective benefits, which include enabling higher penetrations of variable renewable generation at lower cost than alternative storage technologies, and improving economic efficiency. In practice, DR from the commercial and residential sectors is largely an emerging, not a mature, resource, and its actual costs and benefits need to be studied to determine promising combinations of physical DR resource, enabling controls and communications, power system characteristics, regulatory environments, market structures, and business models. The work described in this report focuses on the enablement of such analysis from the production cost modeling perspective. In particular, we contribute a bottom-up methodology for modeling load-shifting DR in production cost models. The resulting model is sufficiently detailed to reflect the physical characteristics and constraints of the underlying flexible load, and includes the possibility of capturing diurnal and seasonal variations in the resource. Nonetheless, the model is of low complexity and thus suitable for inclusion in conventional unit commitment and market clearing algorithms. The ability to simulate DR as an operational resource on a power system over a year facilitates an assessment of its time-varying value to the power system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗