Residual gas analysis device

A system is provided for testing the hermeticity of a package, such as a microelectromechanical systems package containing a sealed gas volume, with a sampling device that has the capability to isolate the package and breach the gas seal connected to a pulse valve that can controllably transmit small volumes down to 2 nanoliters to a gas chamber for analysis using gas chromatography/mass spectroscopy diagnostics.

47 OTHER INSTRUMENTATION↗

Carbothermal Reduction Demonstration (CaRD) Gas Analysis Subsystem Development

The Carbothermal Reduction Demonstration (CaRD) project is currently developing a subscale system to demonstrate the operation and performance of the carbothermal reduction process and quantify the production of molar equivalent oxygen via carbon monoxide (CO) and carbon dioxide (CO2). Traditionally, gas chromatography (GC) systems are utilized to quantify gases due to their ability to separate volatile compounds within the gas mixture, followed by detection of the isolated component of interest. Despite their capabilities, GCs require carrier gas consumables for their operational mobile phase and consequently are not often considered a flight-forward option. An alternative analytical technique known as mass spectrometry measures the presence of gas phase molecules without the need of carrier gas. Residual gas analyzers (RGAs), which are smaller and rugged mass spectrometers, are not traditionally used to quantify analytes as they serve more as a monitoring tool. However, proper application and calibration can result in a flight-forward analytical instrument capable of direct quantification of volatile compounds of interest. Kennedy Space Center's role for the JSC led CaRD project is to design a gas analyzer system to detect and quantify the CO and CO2 gases produced during the carbothermal reaction utilizing a commercial version of the Mass Spectrometer observing lunar operations (MSolo) instrument. MSolo is a modified commercial off-the-shelf RGA, which consists of quadrupole mass filter and space rated electronics. MSolo is currently a TRL 6 technology and manifested on the PRIME-1 and VIPER missions. This paper describes leveraging MSolo based instrumentation to develop a gas analysis system for the work outlined in the 2023 International Conference on Environmental Systems (ICES) paper number 313.

Ryan P Gott↗

Speciation, Characterization and Mobility of As, Se and Hg in Flue Gas Desulphurization Residues

Flue gas from coal combustion contains significant amounts of volatile toxic trace elements such as arsenic (As), selenium (Se), and mercury (Hg). The capture of these elements in the flue gas desulphurization (FGD) scrubber unit has resulted in generation of a metal-laden residue. With increasing reuse of the FGD residues in beneficial applications, it is important to determine metal speciation and mobility to understand the environmental impact of its reuse. In this paper, we report the solid phase speciation of As, Se, and Hg in FGD residues using X-ray absorption spectroscopy (XAS), X-ray fluorescence spectroscopy (XRF), and sequential chemical extraction (SCE) techniques. The SCE results combined with XRF data indicated a strong possibility of As association with iron oxides, whereas Se was distributed among all geochemical phases. Hg appeared to be mainly distributed in the strong-complexed phase. XRF images also suggested a strong association of Hg with Fe oxide materials within FGD residues. XAS analysis indicated that As existed in its oxidized state (As(V)), whereas Se and Hg was observed in primarily reduced states as selenite (Se(IV)) and Hg(I), respectively. The results from the SCE and variable pH leaching tests indicated that the labile fractions of As, Se, and Hg were fairly low and thus suggestive of their stability in the FGD residues. However, the presence of a fine fraction enriched in metal content in the FGD residue suggested that size fractionation is important in assessing the environmental risks associated with their reuse.

01 COAL, LIGNITE, AND PEAT↗

Quantitative planar laser-induced fluorescence imaging of multi-component fuel/air mixing in a firing gasoline-direct-injection engine: Effects of residual exhaust gas on quantitative PLIF

A study of in-cylinder fuel-air mixing distributions in a firing gasoline-direct-injection engine is reported using planar laser-induced fluorescence (PLIF) imaging. A multi-component fuel synthesised from three pairs of components chosen to simulate light, medium and heavy fractions was seeded with one of three tracers, each chosen to co-evaporate with and thus follow one of the fractions, in order to account for differential volatility of such components in typical gasoline fuels. In order to make quantitative measurements of fuel-air ratio from PLIF images, initial calibration was by recording PLIF images of homogeneous fuel-air mixtures under similar conditions of in-cylinder temperature and pressure using a re-circulation loop and a motored engine. This calibration method was found to be affected by two significant factors. Firstly, calibration was affected by variation of signal collection efficiency arising from build-up of absorbing deposits on the windows during firing cycles, which are not present under motored conditions. Secondly, the effects of residual exhaust gas present in the firing engine were not accounted for using a calibration loop with a motored engine. In order to account for these factors a novel method of PLIF calibration is presented whereby 'bookend' calibration measurements for each tracer separately are performed under firing conditions, utilising injection into a large upstream heated plenum to promote the formation of homogeneous in-cylinder mixtures. These calibration datasets contain sufficient information to not only characterise the quantum efficiency of each tracer during a typical engine cycle, but also monitor imaging efficiency, and, importantly, account for the impact of exhaust gas residuals (EGR). By use of this method EGR is identified as a significant factor in quantitative PLIF for fuel mixing diagnostics in firing engines. The effects of cyclic variation in fuel concentration on burn rate are analysed for different fuel injection strategies. Finally, mixture distributions for late injection obtained using quantitative PLIF are compared to predictions of computational fluid dynamics calculations. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Response to 'Comment on 'Controllable local modification of fractured Nb-doped SrTiO{sub 3} surfaces' [Appl. Phys. Lett. 98, 256102 (2011)'.

In their comment, Chen et al. try to argue that the experimentally observed controllable voltage-induced surface modification, which was attributed to a local electric field-induced atom transfer from the surface to the tip, is rather caused by either an oxidation process and/or a resistance change. In this response, we will show that we can rule out these two effects in our experiment. The statements by Chen et al. are based on two arguments: (1) the tip modification after transferring an adatom should alter the dI/dV contrast, which was not seen in our experiments and (2) the vacuum conditions in our experiment are similar to earlier reports on resistance switching. First, Chen et al. discuss that the adsorption on the tip should alter the topographic contrast, as many papers have reported. In fact, in our experiments we frequently observed tip modifications at high bias voltage. These typically result in slight changes in scanning tunneling spectroscopy data [see, for example, the spectra in Fig. 3(b) in Ref. 4 and Fig. 2(d) of Ref. 5] but only weakly affected the topographic contrast. Second, Chen et al. claim that oxidation is another possible mechanism to explain our experimental observations. To support this claim, they compare our results to an earlier publication showing resistance switching. In fact, the resistance switching mechanism is related to oxygen vacancy migration or local surface oxidation. The mechanism of oxygen vacancy migration requires a 'forming' process with a threshold current in the order of microampere or even milliampere. In our experimental setup, however, we used tunneling currents in the order of 50 pA. Even during surface modification, which was performed at open feedback loop conditions with voltage pulse of up to 3 or -5 V, the maximum transient current did not exceed a few nanoampere. Therefore, we can safely exclude oxygen vacancy migration as a potential mechanism for the observed surface modification. As a second potential mechanism Chen et al. mention a local surface oxidation process. However, the total pressure at high-vacuum conditions used in experiments, where resistance switching was observed (10{sup -7} torr in Ref. 3) is three order magnitude higher than in our experiment performed under ultrahigh vacuum (UHV) conditions (below 10{sup -10} torr). Furthermore, mass spectra measured with a residual gas analyzer show that the main residue gas in our UHV system is hydrogen ({approx} 90%). Water, oxygen, and other oxygen-related gases are negligible with a partial pressure in the order of 10{sup -12} torr range or lower. Therefore, we can also exclude that local oxidation with reactants from the residual gas causes the observed modifications. In addition, in our experiment, the refilling of the modified areas at negative bias could not be observed with fresh tip, even for bias voltages as high as -10 V. In short, the mechanism for the modification on the UHV in situ fractured Nb:SrTiO{sub 3} (Nb-doped Strontium titanate) surfaces with scanning tunneling microscope (STM) tip is different from the mechanisms such as local surface oxidation or filament formation, used to explain the largecurrent induced resistance switching works.

08 HYDROGEN↗

Isotopic fractionation of Kr and Xe implanted in solids at very low energies

Results on the implantation of Kr and Xe in W under closed system conditions at very low energies (50-500 eV) are reported. Investigation of the fraction of gas trapped as a function of time reveals the existence of competing trapping and release mechanisms, and analysis of recovered trapped gas and residual gas phases shows that both elemental and isotropic fractionation result from these mechanisms. It is determined that the mass dependence for the overall implantation process is at or near m exp 1, with heavier isotopes enriched in the implanted gas. This mass dependence is inferred to result from implantation and a combination of diffusive and gas sputtering release mechanisms. These results reaffirm the conclusion of Bernatowicz and Fahey (1986) that previously observed isotopic fractionation of Kr and Xe in carbonaceous material synthesized in electrical discharges owes its origin to low-energy ion implantation, and also suggest that this process may be relevant to incorporation of noble gases in early solar system materials. The implication of these results for noble gas mass spectrometry are discussed.

Bernatowicz, Thomas J.↗

Novel method for cleaning a vacuum chamber from hydrocarbon contamination

A novel method for cleaning a high vacuum chamber is presented. This method is based on concurrent in situ high-energetic UV light activation of contaminants located in the residual gas and at the vacuum chamber surfaces as well as the in situ generation of highly reactive ozone. Ozone oxidizes the contaminants to volatile species. Investigations by energy-dispersive x-ray analysis of residual gas depositions and mass-spectroscopy measurements of the residual gas in the vacuum chamber identify the contaminant species as hydrocarbons. After a cleaning period of 8 h, a decrease in measured chamber contamination by about 90% could be achieved according to atomic force microscope analysis. Mass spectroscopy measurements using a residual gas analyzer indicate the creation of volatile, carbonaceous species during the cleaning process.

36 MATERIALS SCIENCE↗

Analysis of a 100-W Regenerative Fuel Cell Demonstration

A 100-W regenerative fuel cell (RFC) demonstration was successfully completed at the NASA Glenn Research Center on December 11, 2014. This effort was funded by Advanced Space Power Systems milestone and represented the first demonstration of passive laboratory-scale stacks arranged as an RFC, consisting of a non-flow-through fuel cell and a static-feed electrolyzer. Once developed, these stacks present the potential to minimize system mass, volume, and parasitic power in comparison to existing terrestrial electrochemical systems and nonnuclear power generation options. Testing involved the fuel cell powering a simulated load then recycling fuel cell product water by subsequently electrolyzing it to regenerate hydrogen and oxygen gases for fuel cell operations. A total of five cycles were completed over a 2-week period, yielding cell voltage data for stack performance and quality measures for regenerated reactants. Overall, round-trip efficiency was calculated to be 47.4 percent. Gas crossover was observed in electrolyzer gas products, as residual gas analysis showed 1.1 percent hydrogen in oxygen and 0.4 percent oxygen in hydrogen. Fuel cell product water was determined to be more acidic and conductive and have a higher fluoride content when compared to deionized water.

fuel cell↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

INL Intern Poster Session

Characterization of off-gas constituents from nuclear fuel reprocessing can be measured using a residual gas analyzer. Characterization of this off-gas is important in a closed fuel cycle, where gasses such as Nox, Kr, I, and C-14 need to be removed from reprocessing plants to meet regulatory requirements. Both Kr and Xe have low chemical reactivity, making capture and separation difficult. Solid sorbents can be used to capture these gases as an alternative to cryogenic distillation, which is energy intensive and hazardous. AgZ-PAN and HZ-PAN are two solid sorbents that have demonstrated selective capture of Xe and Kr. A residual gas analyzer can be used to obtain breakthrough curves that demonstrate how well this adsorption and separation occur. The breakthrough curve is dependent on packing density, column size, and flow rate. Data obtained from the RGA was verified with a gas chromatographer.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of low resolution mass spectra

Computer program determines gas constituents from measurements of mass/peak-height spectrum from residual gas analyzer. Applications of program include residual gas analysis for work in space environmental simulators, space environment contamination, and air pollution monitoring.

Babst, R. W.↗

Engine Operating Conditions and Fuel Properties on Pre-Spark Heat Release and SPI Promotion in SI Engines

This work explores the dependence of fuel ignition delay on stochastic pre-ignition (SPI). Findings are based on bulk gas thermodynamic state, where the effects of kinetically controlled bulk gas pre-spark heat release (PSHR) are correlated to SPI tendency and magnitude. Specifically, residual gas and low temperature PSHR chemistry effects and observations are explored, which are found to be indicative of bulk gas conditions required for strong SPI events. Analyzed events range from non-knocking SPI to knocking SPI and even detonation SPI events in excess of 325 bar peak cylinder pressure. The work illustrates that singular SPI event count and magnitude are found to be proportional to PSHR of the bulk gas mixture and residual gas fraction. Cycle-to-cycle variability in trapped residual mass and temperature are found to impose variability in singular SPI event count and magnitude. However, clusters and short lived bursts of multiple SPI events are found to better correlate with fuel-wall interaction. The results highlight the interplay of bulk gas thermodynamics and SPI ignition source, on SPI event magnitude and cluster tendency. Moreover, the results highlight fundamental fuel reactivity and associated hypersensitivity to operating conditions at SPI prone operating conditions.

Splitter, Derek↗

Fatigue crack growth rates of X100 steel welds in high pressure hydrogen gas considering residual stress effects

Fatigue crack growth rate (FCGR) data were measured in high pressure hydrogen gas versus stress intensity factor range (ΔK) in specimens removed from a X100 welded steel pipe. Three distinct regions of the pipe weld were examined: base metal, weld fusion zone, and heat affected zone. Tests were performed at a load ratio (R) of 0.5, frequency of 1 Hz, and at a hydrogen gas pressure of 21 MPa. Tests were also performed in air at 10 Hz as a reference. Fatigue crack growth rates were observed to be over an order of magnitude higher for tests performed in hydrogen compared to the rates from tests in air. Residual stress measurements were collected on identical specimens cut from the base metal, weld, and heat affected zone to account for their influence on measured FCGR data. The slitting method provided residual stress and residual stress intensity factor (K res ), the effect of which was removed from the FCGR data using K norm in order to provide a more direct comparison of crack growth resistance of the base metal, weld and heat affected zone. Prior to accounting for residual stress, FCGR in hydrogen gas appeared to be highest in the weld fusion zone. Furthermore, after accounting for residual stress effects, the weld fusion zone FCGR data converged to the base metal FCGR data, which underscores the importance of accounting for residual stress effects when assessing fatigue performance.

42 ENGINEERING↗

First storage of ion beams in the Double Electrostatic Ion-Ring Experiment: DESIREE

We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment, DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C{sub n}{sup -}, n= 1, 2, 3, 4) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C{sub 2}{sup -} molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s {+-} 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10{sup -14} mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity.

43 PARTICLE ACCELERATORS↗