Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESOLVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

On symmetry-resolved generalized entropies

Symmetry-resolved entanglement, capturing the refined structure of quantum entanglement in systems with global symmetries, has attracted a lot of attention recently. In this manuscript, introducing the notion of symmetry-resolved generalized entropies, we aim to develop a computational framework suitable for the study of excited state symmetry-resolved entanglement as well as the dynamical evolution of symmetry-resolved entanglement in symmetry-preserving out-of-equilibrium settings. We illustrate our framework using the example of (1+1)-d free massless compact boson theory, and benchmark our results using lattice computation in the XX chain. As a byproduct, our computational framework also provides access to the probability distribution of the symmetry charge contained within a subsystem and the corresponding full counting statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

Spatially-resolved soot evolution and statistics in high-pressure diesel spray flames using two-color pyrometry

Previous studies of diesel spray flames have focused on details of the sooting behavior mainly during the quasi-steady period, but few have considered the spatially-resolved transient evolution in combination with injection-to-injection variations. In this study, a 500-injection data set is utilized to investigate the temporal evolution of a spray flame during auto-ignition, the premixed burn phase, and the quasi-steady period. Spatially-resolved OH* chemiluminescence data provide ignition delay times and reaction zone locations. Two-color pyrom-etry with a vastly improved optical system is used to quantify spatially-resolved soot evolution and its statistical variations. The ambient thermodynamic con-ditions are slightly below those in modern diesel engines, resulting in longer lift-off lengths and lower overall soot production. Spatially, soot formation in the lift-off region is small, but appreciable soot forms in the jet core and jet head regions, while it oxidizes gradually on the jet periphery. Total soot mass profiles indicate that regions with larger local soot mass take longer to form, but are the first to oxidize. Probability distributions of soot mass in localized regions indicate that a few injections with high soot mass bias the average soot mass data towards higher values. Altogether, results show good agreement with previous studies employing different diagnostic techniques while providing statistical details of transient and localized soot behavior in high pressure diesel spray flames in support of the related modeling efforts.

09 BIOMASS FUELS↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Overestimated Eddy Kinetic Energy in the Eddy‐Rich Regions Simulated by Eddy‐Resolving Global Ocean–Sea Ice Models

Abstract The performance of eddy‐resolving global ocean–sea ice models in simulating mesoscale eddies is evaluated using six eddy‐resolving experiments forced by different atmospheric reanalysis products. Interestingly, eddy‐resolving ocean general circulation models (OGCMs) tend to simulate more (less) energetic eddy‐rich (eddy‐poor) regions with a smaller (larger) spatial extent than satellite observation, which finally shows that larger (smaller) mesoscale energy intensity (EI) is simulated in the eddy‐rich (eddy‐poor) regions. Quantitatively, there is an approximately 27%–60% overestimation of EI in the eddy‐rich regions, which are mainly located in the Kuroshio–Oyashio Extension, the Gulf Stream, and the Antarctic Circumpolar Currents regions, although the global mean EI is underestimated by 25%–45%. Apparently, the eddy kinetic energy in the eddy‐poor region is underestimated. Further analyses based on coherent mesoscale eddy properties show that the overestimation in the eddy‐rich regions is mainly attributed to mesoscale eddies’ intensity and is more prominent when mesoscale eddies are in their growth stage.

54 ENVIRONMENTAL SCIENCES↗

Modeling Land-Atmosphere Coupling at Cloud-Resolving Scale Within the Multiple Atmosphere Multiple Land (MAML) Framework in SP-E3SM

Representing subgrid variabilities of land surface processes and their upscaled effects is crucial for global climate modeling. Here, we implement a Multiple Atmosphere Multiple Land (MAML) framework in the superparamaterized version of E3SM (SP32 E3SM) to explicitly simulate the subgrid variabilities of land states and fluxes at cloud-resolving scale and their interactions with atmosphere. Comparing to the standard SP-E3SM in which all the atmospheric columns of the cloud resolving model embedded within the global atmospheric model grid interact with the same land surface (i.e., Multiple Atmosphere Single Land (MASL)), the impact of MAML on the strength of land-atmosphere coupling is limited, partly because the current implementation mainly facilitates one-way coupling between the cloud-resolving model and the land surface model. Despite such limitation, MAML increases the surface latent heat flux at the expense of sensible heat flux, and increases precipitation in India, Amazon, and Central Africa, reducing the model dry bias compared to the standard SP-E3SM. By employing a normalized gross moist stability (NGMS) diagnostic framework, we find that the increase in precipitation minus evaporation (PE) is primarily driven by the change in large-scale moisture convergence, particularly by the increase of water vapor in the lower atmosphere, while the local effect of total surface energy flux plays a minor role in the P-E change. More specifically, MAML changes the surface energy partitioning (evaporative fraction), increases the atmosphere water vapor, and further increases P-E by decreasing the NGMS. Finally, future development in the MAML framework is discussed.

54 ENVIRONMENTAL SCIENCES↗

Evaluating E3SM Global Storm‐Resolving Model Simulations of Deep Convection: Insights From DP‐SCREAM During TRACER

Global Storm-Resolving Models (GSRMs) are becoming increasingly vital for advancing climate modeling and improving the prediction of extreme weather events. Houston, a coastal region frequently affected by deep convective storms, offers an ideal setting to evaluate the ability of GSRMs to simulate deep convection. This study assesses the performance of the Doubly Periodic Simple Cloud-Resolving E3SM (Energy Exascale Earth System Model) Atmosphere Model (DP-SCREAM) using observations from the TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign. DP-SCREAM effectively reproduces the diurnal cycles of clouds and precipitation, demonstrating much greater skill than the E3SM single column model. The DP-SCREAM is demonstrated to be applicable to coastal regions, partially due to the forcing data sets already capturing the influence of breezes. DP-SCREAM also replicates biases persistent in the global version of SCREAM: the underrepresentation of boundary layer shallow clouds, a lack of mid-level congestus clouds, and the popcorn convection, characterized by small and disorganized convective cells generating the strongest precipitation. To investigate these issues, two sensitivity experiments were conducted: increasing the mixing length and scaling up the buoyancy flux within the Simplified Higher Order Closure scheme. Increasing the mixing length improved mid-level congestus representation and reduced unrealistic early morning fog occurrence. Enhancing buoyancy flux only marginally improved the bias of underproduced big convective cells. In conclusion, an additional resolution sensitivity test at 0.5 km grid spacing demonstrated that a refined horizontal resolution alone is insufficient to resolve these biases.

54 ENVIRONMENTAL SCIENCES↗

Development of deflector mode for spin-resolved time-of-flight photoemission spectroscopy

Spin- and angle-resolved photoemission spectroscopy (“spin-ARPES”) is a powerful technique for probing the spin degree-of-freedom in materials with nontrivial topology, magnetism, and strong correlations. Spin-ARPES faces severe experimental challenges compared to conventional ARPES attributed to the dramatically lower efficiency of its detection mechanism, making it crucial for instrumentation developments that improve the overall performance of the technique. Here in this paper, we demonstrate the functionality of our spin-ARPES setup based on time-of-flight spectroscopy and introduce our recent development of an electrostatic deflector mode to map out spin-resolved band structures without sample rotation. We demonstrate the functionality by presenting the spin-resolved spectra of the topological insulator Bi2Te3 and describe in detail the spectrum calibrations based on numerical simulations. By implementing the deflector mode, we minimize the need for sample rotation during measurements, hence improving the overall efficiency of experiments on small or inhomogeneous samples.

47 OTHER INSTRUMENTATION↗

Few-femtosecond resolved imaging of laser-driven nanoplasma expansion

Abstract The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-driven particle acceleration. Here, we show that x-ray coherent diffractive imaging can surpass existing approaches and enables the quantitative real-time analysis of the sudden free expansion of laser-heated nanoplasmas. For laser-ionized SiO 2 nanospheres, we resolve the formation of the emerging nearly self-similar plasma profile evolution and expose the so far inaccessible shell-wise expansion dynamics including the associated startup delay and rarefaction front velocity. Our results establish time-resolved diffractive imaging as an accurate quantitative diagnostic platform for tracing and characterizing plasma expansion and indicate the possibility to resolve various laser-driven processes including shock formation and wave-breaking phenomena with unprecedented resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved resonant inelastic x-ray scattering in a pumped Mott insulator

Collective excitations contain rich information about photoinduced transient states in correlated systems. In a Mott insulator, charge degrees of freedom are frozen, but can be activated by photodoping. The energy-momentum distribution of the charge excitation spectrum reflects the propagation of charge degrees of freedom and provides information about the interplay among various intertwined instabilities on the timescale set by the pump. To reveal charge excitations out of equilibrium, here we simulate time-resolved x-ray absorption and resonant inelastic x-ray scattering using a Hubbard model. After pumping, the former resolves photodoping, while the latter characterizes the formation, dispersion, weight, and nonlinear effects of collective excitations. Intermediate-state information from time-resolved resonant inelastic x-ray scattering (trRIXS) can be used to decipher the origin of these excitations, including bimagnons, Mott-gap excitations, doublon and single-electron in-gap states, and anti-Stokes relaxation during an ultrafast pump. This paper provides a theoretical foundation for existing and future trRIXS experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Size-Resolved Chemical Composition of Particles Collected Using STAC at the Ground Site During the SAIL Campaign in Gunnison, Colorado

Aerosol particles were collected using a four-stage Size and Time-resolved Aerosol Collector (STAC) during the SAIL field campaign. Each stage of STAC separates particles into distinct aerodynamic size fractions with 50% cut-off diameters: Stage A: 2.27 µm Stage B: 0.615 µm Stage C: 0.421 µm Stage D: 0.119 µm Each stage provides both size- and time-resolved sampling, enabling investigation of particle composition across different atmospheric regimes. Only a subset of samples was selected for analysis based on prevailing meteorological conditions (e.g., temperature, humidity, and air-mass influence) to capture representative aerosol types under distinct weather patterns. Collected substrates were first examined under Scanning Electron Microscopy (SEM) to evaluate particle loading, morphology, and spatial distribution. Subsequently, Computer-Controlled Scanning Electron Microscopy with Energy-Dispersive X-ray Spectroscopy (CCSEM/EDX) was performed to obtain size-resolved elemental composition of individual particles. A rule-based classification scheme was applied to categorize particles into major compositional groups (e.g., biological, carbonaceous, dust, sulfate, Na-rich, and mixed types). This dataset provides high-resolution morphological and chemical information on atmospheric particles collected during the SAIL campaign, offering insights into the influence of meteorology on aerosol composition and mixing state.

Size and Time-resolved Aerosol Collector↗

Time-Resolved Structural Kinetics of an Organic Mixed Ionic–Electronic Conductor

The structure and packing of organic mixed ionic–electronic conductors have an especially significant effect on transport properties. In operating devices, this structure is not fixed but is responsive to changes in electrochemical potential, ion intercalation, and solvent swelling. Toward this end, the steady-state and transient structure of the model organic mixed conductor, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), is characterized using multimodal time-resolved operando techniques. Steady-state operando X-ray scattering reveals a doping-induced lamellar expansion of 1.6 Å followed by 0.4 Å relaxation at high doping levels. Time-resolved operando X-ray scattering reveals asymmetric rates of lamellar structural change during doping and dedoping that do not directly depend on potential or charging transients. Further, time-resolved spectroscopy establishes a link between structural transients and the complex kinetics of electronic charge carrier subpopulations, in particular the polaron–bipolaron equilibrium. These findings provide insight into the factors limiting the response time of organic mixed-conductor-based devices, and present the first real-time observation of the structural changes during doping and dedoping of a conjugated polymer system via X-ray scattering.

36 MATERIALS SCIENCE↗

Nanoscale Compositional and Strain Gradients Enable High‐Speed and Amplitude‐Resolved Pyroelectric Sensing

The frequency response of pyroelectric sensors is fundamentally governed by thermal time constant (τth, determined by thermal mass and thermal conductance) and electrical impedance arising from film capacitance and readout circuit. Conventional bulk LiTaO3 detectors are optimized for high responsivity at low modulation frequencies (0.1-10 Hz), possessing a large τth that thermally averages rapid temperature oscillations at elevated modulation frequencies, limiting fidelity in resolving dynamic varying thermal signals. Here, compositional and strain gradients are introduced into 100-nm-thick relaxor-ferroelectric films reducing τth to ≈2 µs and producing built-in potentials (≈1.45 V or 145 kV cm-1) that enhance the pyroelectric coefficient and suppress the dielectric constant. This enables complementary dual-mode operation by enhancing current-mode electrical responsivity and improving the voltage-mode figure of merit - advantageous for superior temperature resolution (ΔTmin ≈ 30 µK). The responsivity peak shifts to near 1 kHz (>2500-times higher than conventional bulk sensors), with measurable responsivity extending to a carrier frequency of 100 kHz and amplitude-resolved detection at modulation frequencies up to 15 kHz. These results establish nanoscale internal-field engineering can reshape electro-thermal trade-off in pyroelectric thin films toward zero-bias, high-thermal-sensitivity, and amplitude-resolved thermal sensing across a wide frequency bandwidth.

Lin, Ching‐Che↗