Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design of a Particle Beam Satellite System for Lunar Prospecting

One potential use for neutral particle beam (NPB) technology is as an active orbital probe to investigate the composition of selected locations on the lunar surface. Because the beam is narrow and can be precisely directed, the NPB probe offers possibilities for high resolution experiments that cannot be accomplished using passive techniques. Rather, the combination of both passive and active techniques can be used to provide both full-coverage mapping (passively) at low resolution (tens of kilometers) and high-resolution information for discrete locations of special interest. A preliminary study of NPB applicability for this dual-use application was recently conducted. The study was completed in Feb. 1993. A novel feature was the consideration of the use of a Russian launch vehicle (e.g., the Proton). The use of other Russian space hardware and capabilities was also encouraged. This paper describes the lunar prospector system design. Other researchers discuss the issues and opportunities involving lunar scientific experimentation using an NPB. The NPB lunar prospector utilizes a modified design of the Far Field Optics Experiment (FOX). Like the Earth-orbiting FOX, the core capability of the NPB lunar prospector will be a pulsed RF LINAC that produces a 5-MeV proton beam that is projected to the target with a 30-micro-r beam divergence and a 10-micro-r beam-pointing accuracy. Upon striking the lunar surface, the proton beam will excite characteristic radiation (e.g., X-rays) that can be sensed by one or more detectors on the NPB platform or on a separate detector satellite.

Berwald, D. H.↗

Performance Evaluation Modeling of Network Sensors

Substantial benefits are promised by operating many spatially separated sensors collectively. Such systems are envisioned to consist of sensor nodes that are connected by a communications network. A simulation tool is being developed to evaluate the performance of networked sensor systems, incorporating such metrics as target detection probabilities, false alarms rates, and classification confusion probabilities. The tool will be used to determine configuration impacts associated with such aspects as spatial laydown, and mixture of different types of sensors (acoustic, seismic, imaging, magnetic, RF, etc.), and fusion architecture. The QualNet discrete-event simulation environment serves as the underlying basis for model development and execution. This platform is recognized for its capabilities in efficiently simulating networking among mobile entities that communicate via wireless media. We are extending QualNet's communications modeling constructs to capture the sensing aspects of multi-target sensing (analogous to multiple access communications), unimodal multi-sensing (broadcast), and multi-modal sensing (multiple channels and correlated transmissions). Methods are also being developed for modeling the sensor signal sources (transmitters), signal propagation through the media, and sensors (receivers) that are consistent with the discrete event paradigm needed for performance determination of sensor network systems. This work is supported under the Microsensors Technical Area of the Army Research Laboratory (ARL) Advanced Sensors Collaborative Technology Alliance.

probability of detection↗

Achievable Precision for Optical Ranging Systems

Achievable RMS errors in estimating the phase, frequency, and intensity of a direct-detected intensity-modulated optical pulse train are presented. For each parameter, the Cramer-Rao-Bound (CRB) is derived and the performance of the Maximum Likelihood estimator is illustrated. Approximations to the CRBs are provided, enabling an intuitive understanding of estimator behavior as a function of the signaling parameters. The results are compared to achievable RMS errors in estimating the same parameters from a sinusoidal waveform in additive white Gaussian noise. This establishes a framework for a performance comparison of radio frequency (RF) and optical science. Comparisons are made using parameters for state-of-the-art deep-space RF and optical links. Degradations to the achievable errors due to clock phase noise and detector jitter are illustrated.

estimation theory↗

Integrated horn antennas for millimeter-wave applications

The development of integrated horn antennas since their introduction in 1987 is reviewed. The integrated horn is fabricated by suspending a dipole antenna, on a thin dielectric membrane, in a pyramidal cavity etched in silicon. Recent progress has resulted in optimized low- and high-gain designs, with single and double polarization for remote-sensing and communication applications. A full-wave analysis technique has resulted in an integrated antenna with performance comparable to that of waveguide-fed corrugated-horn antennas. The integrated horn design can be extended to large arrays, for imaging and phased-array applications, while leaving plenty of room for the RF and IF processing circuitry. Theoretical and experimental results at microwave frequencies and at 90 GHz, 240 GHz, and 802 GHz are presented.

Rebeiz, Gabriel M.↗

Comparison of bit synchronization schemes using AM and summed clocks

This paper considers bit synchronization through the use of a separate clock signal which is either amplitude modulated onto or summed with the data signal. For continuous data transmission, such schemes are known to be inferior, in the sense of efficient use of power, to schemes which derive synchronization directly from the data signal. However, these techniques have application in burst systems such as spacecraft command systems, and in systems where receiver simplicity is more important than power conservation. For systems in which the composite data-clock signal subsequently modulates an RF carrier, it is shown that the summed clock signal performs slightly better than the AM clock signal, and that for both signal types, the optimum allocation of power between data and clock is approximately 9:1.

Geist, J. M.↗

Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column

This passive laser heterodyne radiometer (LHR) instrument simultaneously measures multiple trace gases in the atmospheric column including carbon dioxide (CO2) and methane (CH4), and resolves their concentrations at different altitudes. This instrument has been designed to operate in tandem with the passive aerosol sensor currently used in AERONET (an established network of more than 450 ground aerosol monitoring instruments worldwide). Because aerosols induce a radiative effect that influences terrestrial carbon exchange, simultaneous detection of aerosols with these key carbon cycle gases offers a uniquely comprehensive measurement approach. Laser heterodyne radiometry is a technique for detecting weak signals that was adapted from radio receiver technology. In a radio receiver, a weak input signal from a radio antenna is mixed with a stronger local oscillator signal. The mixed signal (beat note, or intermediate frequency) has a frequency equal to the difference between the input signal and the local oscillator. The intermediate frequency is amplified and sent to a detector that extracts the audio from the signal. In the LHR instrument described here, sunlight that has undergone absorption by the trace gas is mixed with laser light at a frequency matched to a trace gas absorption feature in the infrared (IR). Mixing results in a beat signal in the RF (radio frequency) region that can be related to the atmospheric concentration. For a one-second integration, the estimated column sensitivities are 0.1 ppmv for CO2, and <1 ppbv for CH4. In addition to producing a standalone ground measurement product, this instrument could be used to calibrate/validate four Earth observing missions: ASCENDS (Active Sensing of CO2 Emissions over Nights, Days, and Seasons), OCO-2 (Orbiting Carbon Observatory), OCO-3, and GOSAT (Greenhouse gases Observational SATellite). The only network that currently measures CO2 and CH4 in the atmospheric column is TCCON (Total Carbon Column Observing Network), and only two of its 16 operational sites are in the United States. TCCON data is used for validation of GOSAT data, and will be used for OCO-2 validation. While these Fourier-transform spectrometers (FTS) can measure the largest range of trace gases, the network is severely limited due to the high cost and extreme size of these instruments (these occupy small buildings and require personnel for operation). The LHR/AERONET instrument offers a significantly smaller (carry-on luggage size) autonomous instrument that can be incorporated into AERONET s much larger (450 instruments) global network.

Steel, Emily↗

Advanced Sensor Systems for Biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 microW, which yields a lifetime of approximately 6 - 9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38 x 28 mm to 22 x 8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗

Advanced sensor systems for biotelemetry

The present invention relates to telemetry-based sensing systems that continuously measures physical, chemical and biological parameters. More specifically, these sensing systems comprise a small, modular, low-power implantable biotelemetry system capable of continuously sensing physiological characteristics using implantable transmitters, a receiver, and a data acquisition system to analyze and record the transmitted signal over several months. The preferred embodiment is a preterm labor and fetal monitoring system. Key features of the invention include Pulse Interval Modulation (PIM) that is used to send temperature and pressure information out of the biological environment. The RF carrier frequency is 174-216 MHz and a pair of RF bursts (pulses) is transmitted at a frequency of about 1-2 Hz. The transmission range is 3 to 10 feet, depending on the position of the transmitter in the body and its biological environment. The entire transmitter is encapsulated in biocompatible silicone rubber. Power is supplied by on-board silver-oxide batteries. The average power consumption of the current design is less than 30 .mu.W., which yields a lifetime of approximately 6-9 months. Chip-on-Board technology (COB) drastically reduces the size of the printed circuit board from 38.times.28 mm to 22.times.8 mm. Unpackaged dies are flip-chip bonded directly onto the printed circuit board, along with surface mount resistors and capacitors. The invention can monitor additional physiological parameters including, but not limited to, ECG, blood gases, glucose, and ions such as calcium, potassium, and sodium.

Hines, John W.↗

RFID Torque Sensing Tag System for Fasteners

The present invention provides an RFID-based torque sensor that can be used to quickly monitor off the shelf fasteners including fasteners that are used in expensive satellites or other uses where fastener failure can be very costly. In one embodiment, an antenna, RFID ring and spring comprise a sensor tag that can be interrogated with an interrogation signal produced by an interrogator device. When sufficient torque is applied to the fastener, an RFID circuit is connected, and produces a radio frequency (RF) signal that can be read by the interrogator. In one embodiment, the RFID circuit does not transmit when the spring member is not compressed, thereby indicating insufficient tensioning of the fastener. The present invention offers the ability to remotely, quickly, and inexpensively verify that any number of fasteners are torqued properly upon initial installation. Where applicable, the present invention allows low cost monitoring over the life of the fastener.

Fink, Patrick W.↗

A Machine Learning Approach to Objective Identification of Dust in Satellite Imagery

Airborne dust has broad adverse effects on human activity, including aviation, human health, and agriculture. Remote sensing observations are used to detect dust and aerosols in the atmosphere using long established techniques. False color Red-Green-Blue (RGB) imagery using band differences sensitive to dust absorption (Dust RGB) is currently used operationally to assist forecasters and decision-makers in identifying dust at night, but there are still limitations, subjectivity, and nuances to image interpretation making night-time dust identification difficult even for experts. This study applies machine learning to the problem of night-time dust detection with a simple random forest (RF) model using Geostationary Operational Environmental Satellite-16 (GOES-16) Advanced Baseline Imager (ABI) infrared imagery, band differences sensitive to dust absorption, and Dust RGB color components as inputs to the model. The RF model achieves an Area-Under-Curve (AUC) of 0.97 with a standard deviation of 0.04 for dust cases. For images with dust present, the model correctly labels 85% of dust pixels and 99.96% of no-dust pixels for all dust images in the validation data set. The addition of a single null case to the training data set drastically reduces error in labeling no-dust pixels as dust from 45% to 14.5%. Application of the machine learning model to the April 13–14, 2019 dust event demonstrates the ability of the model to identify dust during night-time hours when visual dust detection is limited by the cooling ground surface characteristics.

dust↗

A long-range and long-life telemetry data-acquisition system for heart rate and multiple body temperatures from free-ranging animals

The system includes an implantable transmitter, external receiver-retransmitter collar, and a microprocessor-controlled demodulator. The size of the implant is suitable for animals with body weights of a few kilograms or more; further size reduction of the implant is possible. The ECG is sensed by electrodes designed for internal telemetry and to reduce movement artifacts. The R-wave characteristics are then specifically selected to trigger a short radio frequency pulse. Temperatures are sensed at desired locations by thermistors and then, based on a heartbeat counter, transmitted intermittently via pulse interval modulation. This modulation scheme includes first and last calibration intervals for a reference by ratios with the temperature intervals to achieve good accuracy even over long periods. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as RF interference.

Lund, G. F.↗

Radio Frequency Survey of the 21-cm Wavelength(l.4 GHz) Allocation for Passive Microwave Observing

Because of the need to develop 1.4-GHz radiometers, a set of RF surveys was conducted in and around our laboratories. In this paper, a measurement campaign and analysis of radio frequency interference (RFI) in the 21 cm wavelength allocation for passive microwave observing, was undertaken. The experimental setup and measurement procedure are outlined and measured data are interpreted. Significant signals were discovered within and surrounding the allocated spectrum at 1.4 GHz. Some implications for remote sensing are discussed.

J R Piepmeier↗

Radar Scattering and Block Size Properties of Lunar Crater Ejecta From Mini-RF and LROC NAC Data

A major objective of the Mini-RF experiment is to distinguish lunar surfaces that may contain water/ice deposits [1,2]. Better understanding of the backscattering properties of craters of varying age and size is crucial for interpreting data received from the Mini-RF. The Mini-RF transmits a circularly polarized RF electromagnetic energy and coherently receives orthogonal linear polarization echoes [1]. The Mini- RF maps in two separate bands ( =12.6 and 4.5 cm) at a high resolution mode of 30 m/pixel [1]. Given the variables mentioned, the four stokes parameters are reconstructed. The Circular Polarization Ratio (CPR) is calculated for the purposes of understanding subsurface and surface roughness. The CPR is determined from reflections acquired from the ratio of power of the transmitted radio wave in same sense to the reflected radio wave in the opposite sense [1]. Ice in the permanently shadowed regions (PSRs) would be transparent to radar, but the inclusions of materials and imperfections would cause the radio wave to reflect multiple times [3], enhancing the number of same sense reflections and increasing the CPR. In addition, ice also displays the coherent backscatter opposition effect (CBOE), an interferrometric addition of same sense backscatter that further increases the CPR of ice targets [7]. High CPR values also correlate to multiple reflections and are typically associated with very rough surfaces [3]. The average dry lunar surface has a CPR in the range of 0.2-0.4 at 48deg incidence [3]. The purpose of this study is to begin to quantify degrees of surface wavelength-scale roughness with CPR and to understand how such surface roughness is created and gradually destroyed by erosion on the lunar surface. Another goal is to identify and isolate the possible causes of high CPR within the shadowed areas of anomalous polar craters [3]. All the studied craters are non-polar, so that we can see into their interiors in NAC images. The idea is to understand what controls blockiness in these craters so that we can rule out rocks (and rule in ice) for the anomalous polar dark ones [3].

Spudis, P. D.↗

Embedded Thermal Control for Spacecraft Subsystems Miniaturization

Optimization of spacecraft size, weight and power (SWaP) resources is an explicit technical priority at Goddard Space Flight Center. Embedded Thermal Control Subsystems are a promising technology with many cross cutting NSAA, DoD and commercial applications: 1.) CubeSatSmallSat spacecraft architecture, 2.) high performance computing, 3.) On-board spacecraft electronics, 4.) Power electronics and RF arrays. The Embedded Thermal Control Subsystem technology development efforts focus on component, board and enclosure level devices that will ultimately include intelligent capabilities. The presentation will discuss electric, capillary and hybrid based hardware research and development efforts at Goddard Space Flight Center. The Embedded Thermal Control Subsystem development program consists of interrelated sub-initiatives, e.g., chip component level thermal control devices, self-sensing thermal management, advanced manufactured structures. This presentation includes technical status and progress on each of these investigations. Future sub-initiatives, technical milestones and program goals will be presented.

Thermal Control↗

Multi-Layer RF Tissue Phantoms for Mimicking a Human Core

This work presents the design recipe, fabrication process and characterization of tissue-simulating materials, configured as a physical model to mimic the electrical and some physical properties of an abdominal cavity. The complete three layer design is called the human core model (HCM). To our knowledge, presented is the first hybrid skin-muscle phantom developed to mimic the electrical properties of the intervening tissue layers of an abdominal cavity within the frequency band of 1 GHz 2 GHz, a band of interest for human body sensing due to its deep detection depth. To complete the model, a liquid blood phantom was also developed and characterized in this frequency band. The phantoms were characterized with respect to complex dielectric constant using the Agilent 85070E dielectric probe kit, and the results compared to the Gabriel model, which is used as the standard for human tissue characterization. Since the tissue impedance is an important parameter for characterizing on-body sensors and near field antenna performance, the impedance of the phantoms were also calculated and presented in the analysis.

Bonds, Quenton↗

Adaptive Bio-Inspired Wireless Network Routing for Planetary Surface Exploration

Wireless mobile networks suffer connectivity loss when used in a terrain that has hills, and valleys when line of sight is interrupted or range is exceeded. To resolve this problem and achieve acceptable network performance, we have designed an adaptive, configurable, hybrid system to automatically route network packets along the best path between multiple geographically dispersed modules. This is very useful in planetary surface exploration, especially for ad-hoc mobile networks, where computational devices take an active part in creating a network infrastructure, and can actually be used to route data dynamically and even store data for later transmission between networks. Using inspiration from biological systems, this research proposes to use ant trail algorithms with multi-layered information maps (topographic maps, RF coverage maps) to determine the best route through ad-hoc network at real time. The determination of best route is a complex one, and requires research into the appropriate metrics, best method to identify the best path, optimizing traffic capacity, network performance, reliability, processing capabilities and cost. Real ants are capable of finding the shortest path from their nest to a food source without visual sensing through the use of pheromones. They are also able to adapt to changes in the environment using subtle clues. To use ant trail algorithms, we need to define the probability function. The artificial ant is, in this case, a software agent that moves from node to node on a network graph. The function to calculate the fitness (evaluate the better path) includes: length of the network edge, the coverage index, topology graph index, and pheromone trail left behind by other ant agents. Each agent modifies the environment in two different ways: 1) Local trail updating: As the ant moves between nodes it updates the amount of pheromone on the edge; and 2) Global trail updating: When all ants have completed a tour the ant that found the shortest route updates the edges in its path.

Alena, Richard I.↗

An implantable blood pressure and flow transmitter.

A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

Rader, R. D.↗

Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique

Pulse compression has been widely used in radars so that low-power, long RF pulses can be transmitted, rather than a highpower short pulse. Pulse compression radars offer a number of advantages over high-power short pulsed radars, such as no need of high-power RF circuitry, no need of high-voltage electronics, compact size and light weight, better range resolution, and better reliability. However, range sidelobe associated with pulse compression has prevented the use of this technique on spaceborne radars since surface returns detected by range sidelobes may mask the returns from a nearby weak cloud or precipitation particles. Research on adaptive pulse compression was carried out utilizing a field-programmable gate array (FPGA) waveform generation board and a radar transceiver simulator. The results have shown significant improvements in pulse compression sidelobe performance. Microwave and millimeter-wave radars present many technological challenges for Earth and planetary science applications. The traditional tube-based radars use high-voltage power supply/modulators and high-power RF transmitters; therefore, these radars usually have large size, heavy weight, and reliability issues for space and airborne platforms. Pulse compression technology has provided a path toward meeting many of these radar challenges. Recent advances in digital waveform generation, digital receivers, and solid-state power amplifiers have opened a new era for applying pulse compression to the development of compact and high-performance airborne and spaceborne remote sensing radars. The primary objective of this innovative effort is to develop and test a new pulse compression technique to achieve ultrarange sidelobes so that this technique can be applied to spaceborne, airborne, and ground-based remote sensing radars to meet future science requirements. By using digital waveform generation, digital receiver, and solid-state power amplifier technologies, this improved pulse compression technique could bring significant impact on future radar development. The novel feature of this innovation is the non-linear FM (NLFM) waveform design. The traditional linear FM has the limit (-20 log BT -3 dB) for achieving ultra-low-range sidelobe in pulse compression. For this study, a different combination of 20- or 40-microsecond chirp pulse width and 2- or 4-MHz chirp bandwidth was used. These are typical operational parameters for airborne or spaceborne weather radars. The NLFM waveform design was then implemented on a FPGA board to generate a real chirp signal, which was then sent to the radar transceiver simulator. The final results have shown significant improvement on sidelobe performance compared to that obtained using a traditional linear FM chirp.

Li, Lihua↗