Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROI evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-D-303-03: Impact of Uncertainty in T1 Measurements On Quantification of Dynamic Contrast Enhanced MRI

Purpose: Quantification of dynamic contrast enhanced (DCE) MRI requires native longitudinal relaxation time (T1) measurement. This study aimed to assess uncertainty in T1 measurements using two different methods. Methods and Materials: Brain MRI scans were performed on a 3T scanner in 9 patients who had low grade/benign tumors and partial brain radiotherapy without chemotherapy at pre-RT, week-3 during RT (wk-3), end-RT, and 1, 6 and 18 months after RT. T1-weighted images were acquired using gradient echo sequences with 1) 2 different flip angles (50 and 150), and 2) 5 variable TRs (100–2000ms). After creating quantitative T1 maps, average T1 was calculated in regions of interest (ROI), which were distant from tumors and received a total of accumulated radiation doses < 5 Gy at wk-3. ROIs included left and right normal Putamen and Thalamus (gray matter: GM), and frontal and parietal white matter (WM). Since there were no significant or even a trend of T1 changes from pre-RT to wk-3 in these ROIs, a relative repeatability coefficient (RC) of T1 as a measure of uncertainty was estimated in each ROI using the data pre-RT and at wk-3. The individual T1 changes at later time points were evaluated compared to the estimated RCs. Results: The 2-flip angle method produced small RCs in GM (9.7–11.7%) but large RCs in WM (12.2–13.6%) compared to the saturation-recovery (SR) method (11.0–17.7% for GM and 7.5–11.2% for WM). More than 81% of individual T1 changes were within T1 uncertainty ranges defined by RCs. Conclusion: Our study suggests that the impact of T1 uncertainty on physiological parameters derived from DCE MRI is not negligible. A short scan with 2 flip angles is able to achieve repeatability of T1 estimates similar to a long scan with 5 different TRs, and is desirable to be integrated in the DCE protocol. Present study was supported by National Institute of Health (NIH) under grant numbers; UO1 CA183848 and RO1 NS064973.

60 APPLIED LIFE SCIENCES↗

MO-C-17A-02: A Novel Method for Evaluating Hepatic Stiffness Based On 4D-MRI and Deformable Image Registration

Purpose: Quantitative imaging of hepatic stiffness has significant potential in radiation therapy, ranging from treatment planning to response assessment. This study aims to develop a novel, noninvasive method to quantify liver stiffness with 3D strains liver maps using 4D-MRI and deformable image registration (DIR). Methods: Five patients with liver cancer were imaged with an institutionally developed 4D-MRI technique under an IRB-approved protocol. Displacement vector fields (DVFs) across the liver were generated via DIR of different phases of 4D-MRI. Strain tensor at each voxel of interest (VOI) was computed from the relative displacements between the VOI and each of the six adjacent voxels. Three principal strains (E{sub 1}, E{sub 2} and E{sub 3}) of the VOI were derived as the eigenvalue of the strain tensor, which represent the magnitudes of the maximum and minimum stretches. Strain tensors for two regions of interest (ROIs) were calculated and compared for each patient, one within the tumor (ROI{sub 1}) and the other in normal liver distant from the heart (ROI{sub 2}). Results: 3D strain maps were successfully generated fort each respiratory phase of 4D-MRI for all patients. Liver deformations induced by both respiration and cardiac motion were observed. Differences in strain values adjacent to the distant from the heart indicate significant deformation caused by cardiac expansion during diastole. The large E{sub 1}/E{sub 2} (∼2) and E{sub 1}/E{sub 2} (∼10) ratios reflect the predominance of liver deformation in the superior-inferior direction. The mean E{sub 1} in ROI{sub 1} (0.12±0.10) was smaller than in ROI{sub 2} (0.15±0.12), reflecting a higher degree of stiffness of the cirrhotic tumor. Conclusion: We have successfully developed a novel method for quantitatively evaluating regional hepatic stiffness based on DIR of 4D-MRI. Our initial findings indicate that liver strain is heterogeneous, and liver tumors may have lower principal strain values than normal liver. Thorough validation of our method is warranted in future studies. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-08: Results of a Multi-Institutional Study for the Evaluation of Deformable Image Registration Algorithms for Structure Delineation Via Computational Phantoms

Purpose: To investigate the accuracy of various algorithms for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on patient images using different commercial systems. This work is part of an Italian multi-institutional study to test on common datasets the accuracy, reproducibility and safety of DIR applications in Adaptive Radiotherapy. Methods: Eleven institutions with three available commercial solutions provided data to assess the agreement of DIR-propagated ROIs with automatically drown ROIs considered as ground-truth for the comparison. The DIR algorithms were tested on real patient data from three different anatomical districts: head and neck, thorax and pelvis. For every dataset two specific Deformation Vector Fields (DVFs) provided by ImSimQA software were applied to the reference data set. Three different commercial software were used in this study: RayStation, Velocity and Mirada. The DIR-mapped ROIs were then compared with the reference ROIs using the Jaccard Conformity Index (JCI). Results: More than 600 DIR-mapped ROIs were analyzed. Putting together all JCI data of all institutions for the first DVF, the mean JCI was 0.87 ± 0.7 (1 SD) while for the second DVF JCI was 0.8 ± 0.13 (1 SD). Several considerations on different structures are available from collected data: the standard deviation among different institutions on specific structure raise as the larger is the applied DVF. The higher value is 10% for bladder. Conclusion: Although the complexity of deformation of human body is very difficult to model, this work illustrates some clinical scenarios with well-known DVFs provided by specific software. CI parameter gives the inter-user variability and may put in evidence the need of improving the working protocol in order to reduce the inter-institution JCI variability.

60 APPLIED LIFE SCIENCES↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-20: Adaptive Aperture Morphing for Online Correction for Prostate Cancer Radiotherapy

Purpose: Online adaptive aperture morphing is desirable over translational couch shifts to accommodate not only the target position variation but also anatomic changes (rotation, deformation, and relation of target to organ-atrisks). We proposed quick and reliable method for adapting segment aperture leaves for IMRT treatment of prostate. Methods: The proposed method consists of following steps: (1) delineate the contours of prostate, SV, bladder and rectum on kV-CBCT; (2) determine prostate displacement from the rigid body registration of the contoured prostate manifested on the reference CT and the CBCT; (3) adapt the MLC segment apertures obtained from the pre-treatment IMRT planning to accommodate the shifts as well as anatomic changes. The MLC aperture adaptive algorithm involves two steps; first move the whole aperture according to prostate translational/rotational shifts, and secondly fine-tune the aperture shape to maintain the spatial relationship between the planning target contour and the MLC aperture to the daily target contour. Feasibility of this method was evaluated retrospectively on a seven-field IMRT treatment of prostate cancer patient by comparing dose volume histograms of the original plan and the aperture-adjusted plan, with/without additional segments weight optimization (SWO), on two daily treatment CBCTs selected with relative large motion and rotation. Results: For first daily treatment, the prostate rotation was significant (12degree around lateral-axis). With apertureadjusted plan, the D95 to the target was improved 25% and rectum dose (D30, D40) was reduced 20% relative to original plan on daily volumes. For second treatment-fraction, (lateral shift = 6.7mm), after adjustment target D95 improved by 3% and bladder dose (D30, maximum dose) was reduced by 1%. For both cases, extra SWO did not provide significant improvement. Conclusion: The proposed method of adapting segment apertures is promising in treatment position correction, including target translational displacement, rotation and deformation. Additional SWO could improve ROIs dose distribution.

60 APPLIED LIFE SCIENCES↗

Assessment and Simulation of Particulate Transport for Delivery of Solid Amendments into the Subsurface: FY25 Status Report

For particulate-based amendments to be viable for field-scale remediation at the Hanford Site (e.g., the 200 DV-1 Operable Unit), amendment particles need to be delivered a reasonable distance away from an injection well to provide cost effective in situ treatment. Field-scale particle transport models can estimate spatial deposition of amendment particles in the subsurface, which is critical for developing an overall remediation strategy. However, field-scale particle simulations are currently limited due to insufficient simulation capability and a lack of experimental data to validate and parameterize particle transport models. During this fiscal year, the following progress has been made toward a field-scale particle transport modeling evaluation: (1) in addition to the two particle transport models implemented last FY, four additional particle transport models have been implemented within PFLOTRAN; (2) a Python-based pre-screening tool was finalized, enabling users to quickly estimate the particle radius of influence (ROI) for any given particle-amendment system; and (3) an initial compatibility assessment was completed using both particle transport simulations deployed through the pre-screening tool, in conjunction with general guidelines to (a) identify the most suitable amendment particle sizes for various Hanford sediments and (b) evaluate amendment-delivery fluid compatibility. The preliminary compatibility assessment revealed that for amendment delivery success to the various Hanford target formations, amendment particle sizes will likely need to be smaller than the amendment sizes tested in the DV-1 treatability study. It is recommended that amendment particles be decreased in size, or alternative smaller size amendments be obtained from the manufacture, prior to any further experimental testing. Also, preliminary testing suggests that xanthan gum may be the most broadly compatible delivery fluid. Planned laboratory experiments will be instrumental in validating and refining the PFLOTRAN particulate transport model formulations, ultimately enabling predictive capabilities to facilitate the design of field-scale amendment delivery systems. This work consists of acquiring new theoretical or experimental knowledge. The information associated with this report should not be used as design input or operating parameters without additional qualification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-J-29: Dosimetric Effect of Image Registration ROI Size and Focus in Automated CBCT Registration for Spine SBRT

Purpose: Spinal stereotactic body radiotherapy (SBRT) involves highly conformal dose distributions and steep dose gradients due to the proximity of the spinal cord to the treatment volume. To achieve the planning goals while limiting the spinal cord dose, patients are setup using kV cone-beam CT (kV-CBCT) with 6 degree corrections. The kV-CBCT registration with the reference CT is dependent on a user selected region of interest (ROI). The objective of this work is to determine the dosimetric impact of ROI selection. Methods: Twenty patients were selected for this study. For each patient, the kV-CBCT was registered to the reference CT using three ROIs including: 1) the external body, 2) a large anatomic region, and 3) a small region focused in the target volume. Following each registration, the aligned CBCTs and contours were input to the treatment planning system for dose evaluation. The minimum dose, dose to 99% and 90% of the tumor volume (D99%, D90%), dose to 0.03cc and the dose to 10% of the spinal cord subvolume (V10Gy) were compared to the planned values. Results: The average deviations in the tumor minimum dose were 2.68%±1.7%, 4.6%±4.0%, 14.82%±9.9% for small, large and the external ROIs, respectively. The average deviations in tumor D99% were 1.15%±0.7%, 3.18%±1.7%, 10.0%±6.6%, respectively. The average deviations in tumor D90% were 1.00%±0.96%, 1.14%±1.05%, 3.19%±4.77% respectively. The average deviations in the maximum dose to the spinal cord were 2.80%±2.56%, 7.58%±8.28%, 13.35%±13.14%, respectively. The average deviation in V10Gy to the spinal cord were 1.69%±0.88%, 1.98%±2.79%, 2.71%±5.63%. Conclusion: When using automated registration algorithms for CBCT-Reference alignment, a small target-focused ROI results in the least dosimetric deviation from the plan. It is recommended to focus narrowly on the target volume to keep the spinal cord dose below tolerance.

60 APPLIED LIFE SCIENCES↗

SU-E-J-104: Single Photon Image From PET with Insertable SPECT Collimator for Boron Neutron Capture Therapy: A Feasibility Study

Purpose: The aim of our proposed system is to confirm the feasibility of extraction of two types of images from one positron emission tomography (PET) module with an insertable collimator for brain tumor treatment during the BNCT. Methods: Data from the PET module, neutron source, and collimator was entered in the Monte Carlo n-particle extended (MCNPX) source code. The coincidence events were first compiled on the PET detector, and then, the events of the prompt gamma ray were collected after neutron emission by using a single photon emission computed tomography (SPECT) collimator on the PET. The obtaining of full width at half maximum (FWHM) values from the energy spectrum was performed to collect effective events for reconstructed image. In order to evaluate the images easily, five boron regions in a brain phantom were used. The image profiles were extracted from the region of interest (ROI) of a phantom. The image was reconstructed using the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The image profiles and the receiver operating characteristic (ROC) curve were compiled for quantitative analysis from the two kinds of reconstructed image. Results: The prompt gamma ray energy peak of 478 keV appeared in the energy spectrum with a FWHM of 41 keV (6.4%). On the basis of the ROC curve in Region A to Region E, the differences in the area under the curve (AUC) of the PET and SPECT images were found to be 10.2%, 11.7%, 8.2% (center, Region C), 12.6%, and 10.5%, respectively. Conclusion: We attempted to acquire the PET and SPECT images simultaneously using only PET without an additional isotope. Single photon images were acquired using an insertable collimator on a PET detector. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, Information and Communication Technologies (ICT) and Future Planning (MSIP)(Grant No.2009 00420) and the Radiation Technology R and D program (Grant No.2013M2A2A7043498), Republic of Korea.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-94: Daily Fraction Dose Recalculation Based On Rigid Registration Using Cone Beam CT

Purpose: To calculate the daily fraction dose for a CBCT recalculation based on rigid registration and compare it to the planned CT dose. Methods: For this study, 30 patients that were previously treated (10 SBRT lung, 10 prostate and 10 abdomen) were considered. The daily CBCT images were imported into the Pinnacle treatment planning system from Mosaic. The prescribing physician contoured the regions of interest (ROI) on each CBCT and then dose was computed on each CBCT. Each CBCT dose distribution was then compared against the plan. The evaluation was based on isodose line comparison and Dose Volume Histogram comparison. Results: In the case of lung patients the dose differences between daily dose and plan dose were considered small. The PTV coverage was not compromised and the dose to the organs at risk had negligible differences. Larger differences were observed for prostate and abdomen patients. In these cases, although the PTV doses did not change on a daily basis, the doses to the organs at risk had significant differences. For a prostate patient, the bladder dose at 35% volume was 2714.444 cGy for the CT plan and 2844.747, 2801.556, 3552.37, and 2970.968 cGy for subsequent CBCTs. For the PTV on a SBRT patient, however, the CT plan had a dose at 35% volume of 6917.71 cGy and 6815.385, 6892.5, 6896.25, and 6922.9 cGy for the CBCTs. Conclusion: Daily dose validation is feasible using CBCT and treatment planning system. It provides means to evaluate the course of treatment for the patient undergoing radiation therapy and can assist in the decision of the need of adaptation of the treatment plan.

60 APPLIED LIFE SCIENCES↗

Data-Driven Surface Traversability Analysis for Mars 2020 Landing Site Selection

The objective of this paper is three-fold: 1) to describe the engineering challenges in the surface mobility of the Mars 2020 Rover mission that are considered in the landing site selection processs, 2) to introduce new automated traversability analysis capabilities, and 3) to present the preliminary analysis results for top candidate landing sites. The analysis capabilities presented in this paper include automated terrain classification, automated rock detection, digital elevation model (DEM) generation, and multi-ROI (region of interest) route planning. These analysis capabilities enable to fully utilize the vast volume of high-resolution orbiter imagery, quantitatively evaluate surface mobility requirements for each candidate site, and reject subjectivity in the comparison between sites in terms of engineering considerations. The analysis results supported the discussion in the Second Landing Site Workshop held in August 2015, which resulted in selecting eight candidate sites that will be considered in the third workshop.

Ono, Masahiro↗

SU-E-T-604: Penumbra Characteristics of a New InCiseâ„¢ Multileaf Collimator of CyberKnife M6â„¢ System

Purpose: The InCise™ Multileaf Collimator (MLC) of CyberKnife M6™ System has been released recently. The purpose of this study was to explore the dosimetric characteristics of the new MLC. In particular, the penumbra characteristics of MLC fields at varying locations are evaluated. Methods: EBT3-based film measurements were performed with varying MLC fields ranging from 7.5 mm to 27.5 mm. Seventeen regions of interests (ROIs) were identified for irradiation. These are regions located at the central area (denoted as reference field), at the left/right edge areas of reference open field, at an intermediate location between central and edge area. Single beam treatment plans were designed by using the MultiPlan and was delivered using the Blue Phantom. Gafchromic films were irradiated at 1.5 cm depth in the Blue Phantom and analyzed using the Film Pro software. Variation of maximum dose, penumbra of MLC-defined fields, and symmetry/flatness were calculated as a function of locations of MLC fields. Results: The InCise™ MLC System showed relatively consistent dose distribution and penumbra size with varying locations of MLC fields. The measured maximum dose varied within 5 % at different locations compared to that at the central location and agreed with the calculated data well within 2%. The measured penumbrae were in the range of 2.9 mm and 3.7 mm and were relatively consistent regardless of locations. However, dose profiles in the out-of-field and in-field regions varied with locations and field sizes. Strong variation was seen for all fields located at 55 mm away from the central field. The MLC leakage map showed that the leakage is dependent on position. Conclusion: The size of penumbra and normalized maximum dose for MLC-defined fields were consistent in different regions of MLC. However, dose profiles in the out-field region varied with locations and field sizes.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-FG-209-04: Testing of Digital Image Receptors Using AAPM TG-150’s Draft Recommendations - Investigating the Impact of Different Processing Parameters

Purpose: To evaluate implementation of AAPM TG-150’s draft recommendations via a parameter study for testing the performance of digital image receptors. Methods: Flat field images were acquired from 9 calibrated digital image receptors associated with 9 new portable digital radiography systems (Carestream Health, Inc.) based on the draft recommendations and manufacturer-specified calibration conditions (set of 4 images at input detector air kerma ranging from 1 to 25 µGy). Effects of exposure response function (linearized and logarithmic), ‘Presentation Intent Type’ (‘For Processing’ and ‘For Presentation’), detector orientation with respect to the anode-cathode axis (4 orientations; 900 rotations per iteration), different ROI sizes (5×5–40×40 mm{sup 2}) and elimination of varying dimensions of image border (0 mm i.e., without boundary elimination to 150 mm) on signal, noise, signal-to-noise ratio (SNR) and the associated nonuniformities were evaluated. Images were analyzed in Matlab and quantities were compared using ANOVA. Results: Signal, noise and SNR values averaged over 9 systems with default parameter values in draft recommendations were 4837.2±139.4, 19.7±0.9 and 246.4±10.1 (mean ± standard deviation), respectively (at input detector air kerma: 12.5 µGy). Signal, noise and SNR showed characteristic dependency on exposure response function and on ‘Presentation Intent Type’. These values were not affected by ROI size and detector orientation, but analysis showed that eliminating the edge pixels along the boundary was required for the noise parameter (coefficient of variation range for noise: 72%–106% and 3%–4% without and with boundary elimination; respectively). Local and global nonuniformities showed a similar dependence on the need for boundary elimination. Interestingly, computed non-uniformities showed agreement with manufacturer-reported values except for noise non-uniformities in two units; artifacts were seen in images from these two units highlighting the importance of independent evaluations. Conclusion: The effect of different parameters on performance characterization of digital image receptors was evaluated based on TG-150’s draft recommendations.

60 APPLIED LIFE SCIENCES↗

Mars Surface System Common Capabilities and Challenges for Human Missions

NASA has begun a process to identify and evaluate candidate locations where humans could land, live and work on the martian surface. These locations are referred to as Exploration Zones (EZs). Given current mission concepts, an EZ is a collection of Regions of Interest (ROIs) that are located within approximately 100 kilometers of a centralized landing site. ROIs are areas that are relevant for scientific investigation and/or development/maturation of capabilities and resources necessary for a sustainable human presence. The EZ also contains a landing site and a habitation site that will be used by multiple human crews during missions to explore and utilize the ROIs within the EZ. In parallel with this process, NASA continues to make progress on the Evolvable Mars Campaign examining alternatives that can pioneer an extended human presence on Mars that is Earth independent. This involves ongoing assessments of surface systems and operations to enable a permanent, sustainable human presence. Because of the difficulty in getting equipment and supplies to the surface of Mars, part of these assessments involve identifying those systems and processes that can perform in multiple, sometimes completely unrelated, situations. These assessments have been performed in a very generic surface mission carried out at a very generic surface location. As specific candidate EZs are identified it becomes important to evaluate the current suite of surface systems and operations as they are likely to perform for the specific locations and for the types of operations - both scientific and development - that are proposed for these EZs. It is also important to evaluate the proposed EZs for their suitability to be explored or developed given the range of capabilities and constraints for the types of surface systems and operations being considered within the EMC. This means looking at setting up and operating a field station at a central location within the EZ as well as traversing to and exploring the scientific ROIs within the boundaries of the EZ. The proposed paper will describe the current status of common systems and operations as they can be applied to actual EZ locations on Mars. Initially these EZs will be the four locations identified MEPAG's Human Exploration of Mars Science Analysis Group (HEM‐SAG) that will be used as representative of the EZs that will emerge from the process that NASA has initiated. An example process that could be commonly applied is an approach for developing a field station site plan that would be demonstrated by applying this process to each of the four HEM‐SAG sites. Examples of common systems include (a) mobility systems that can be used to off‐load and move payloads to specific locations at the central field station location that could also be used to traverse long distances to reach some of the more remote ROIs or (b) robotic systems that can support various activities (such as system set up and maintenance) at the field station that could also be used to explore scientific ROIs and used to support site‐specific ISRU production activities.

Hoffman, Stephen J.↗

SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.

60 APPLIED LIFE SCIENCES↗

Evaluation of MODIS and Sentinel-3 SLSTR Thermal Emissive Bands Calibration Consistency Using Dome C

Over the years, data from different satellites has provided invaluable information about Earth's atmosphere, land and oceans. The thermal emissive bands (TEB) on the Moderate Resolution Imaging Spectroradiometer (MODIS) are comprised of 16 spectral bands with wavelengths ranging from 3.7 to 14.4 μm. MODIS TEB are calibrated on orbit on a scan-by-scan basis using an on-board blackbody (BB). Sentinel-3 Sea and Land Surface Temperature Radiometer (SLSTR), launched on 16 February 2016, has 11 spectral bands with wavelengths from 0.55 to 12 μm. In this study, we compare the observed brightness temperature from MODIS bands 31 and 32 and SLSTR bands S8 and S9 over Dome C using a 20 × 20 km region of interest (ROI) centered at (75.102 °S,123.395 °E). A total of 2989 scenes for Terra, 2963 for Aqua and 1961 for SLSTR from November, 2016 to January 2018 are analyzed. The relative bias between MODIS and SLSTR is evaluated using the near-surface temperature measurements from an Automatic Weather Station (AWS).

Shrestha, Ashish↗

SU-E-J-94: Geometric and Dosimetric Evaluation of Deformation Image Registration Algorithms Using Virtual Phantoms Generated From Patients with Lung Cancer

Purpose: To generate virtual phantoms with clinically relevant deformation and use them to objectively evaluate geometric and dosimetric uncertainties of deformable image registration (DIR) algorithms. Methods: Ten lung cancer patients undergoing adaptive 3DCRT planning were selected. For each patient, a pair of planning CT (pCT) and replanning CT (rCT) were used as the basis for virtual phantom generation. Manually adjusted meshes were created for selected ROIs (e.g. PTV, lungs, spinal cord, esophagus, and heart) on pCT and rCT. The mesh vertices were input into a thin-plate spline algorithm to generate a reference displacement vector field (DVF). The reference DVF was used to deform pCT to generate a simulated replanning CT (srCT) that was closely matched to rCT. Three DIR algorithms (Demons, B-Spline, and intensity-based) were applied to these ten virtual phantoms. The images, ROIs, and doses were mapped from pCT to srCT using the DVFs computed by these three DIRs and compared to those mapped using the reference DVF. Results: The average Dice coefficients for selected ROIs were from 0.85 to 0.96 for Demons, from 0.86 to 0.97 for intensity-based, and from 0.76 to 0.95 for B-Spline. The average Hausdorff distances for selected ROIs were from 2.2 to 5.4 mm for Demons, from 2.3 to 6.8 mm for intensity-based, and from 2.4 to 11.4 mm for B-Spline. The average absolute dose errors for selected ROIs were from 0.2 to 0.6 Gy for Demons, from 0.1 to 0.5 Gy for intensity-based, and from 0.5 to 1.5 Gy for B-Spline. Conclusion: Virtual phantoms were modeled after patients with lung cancer and were clinically relevant for adaptive radiotherapy treatment replanning. Virtual phantoms with known DVFs serve as references and can provide a fair comparison when evaluating different DIRs. Demons and intensity-based DIRs were shown to have smaller geometric and dosimetric uncertainties than B-Spline. Z Shen: None; K Bzdusek: an employee of Philips Healthcare; J Greskovich: None; P Xia: received research grants from Philips Healthcare and Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Nonlocal atlas-guided multi-channel forest learning for human brain labeling

Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient to measure the overlap degree. Their method achieves average overlaps of 82.56% on 54 regions of interest (ROIs) and 79.78% on 80 ROIs, respectively, which significantly outperform the baseline method (random forests), with the average overlaps of 72.48% on 54 ROIs and 72.09% on 80 ROIs, respectively. Conclusions: The proposed methods have achieved the highest labeling accuracy, compared to several state-of-the-art methods in the literature.

61 RADIATION PROTECTION AND DOSIMETRY↗