Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detection of space radiation-induced double strand breaks as a track in cell nucleus

To identify DNA damage induced by space radiations such as the high linear energy transfer (LET) particles, phospho-H2AX ({gamma}H2AX) foci formation was analyzed in human cells frozen in an International Space Station freezer for 133 days. After recovering the frozen sample to the earth, the cells were cultured for 30 min, and then fixed. Here we show a track of {gamma}H2AX positive foci in them by immuno-cytochemical methods. It is suggested that space radiations, especially high LET particles, induced DSBs as a track. From the formation of the tracks in nuclei, exposure dose rate was calculated to be 0.7 mSv per day as relatively high-energy space radiations of Fe-ions (500 MeV/u, 200 keV/{mu}m). From the physical dosimetry with CR-39 plastic nuclear track detectors and thermo-luminescent dosimeters, dose rate was 0.5 mSv per day. These values the exposed dose rate were similar between biological and physical dosimetries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Flowing damage in ion-implanted amorphous silicon

Using molecular-dynamics simulations, we have studied the creation and evolution of damage in crystalline and amorphous silicon following the implantation of energetic keV ions. A method is proposed to identify anomalous atoms based on a weighted combination of local, atomic-scale properties, which applies to both Si phases. For crystalline Si, the passage of the ions causes compact amorphous regions to form, while no evidence for melting is observed. The relaxation of the amorphouslike regions proceeds initially by the rapid recrystallization of smaller clusters and isolated atoms, followed by a long period of steplike changes in the number of defects due to spontaneous annealing of damage pockets at the crystalline-amorphous interface. In amorphous Si, the initial stage of damage annealing (which lasts a few picoseconds) resembles closely that observed in crystalline Si; on larger time scales, however, the damage is found to ''percolate,'' or flow, through the system, inducing damage away from the collision cascade, thus causing an overall ''derelaxation'' of the material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-T-565: RAdiation Resistance of Cancer CElls Using GEANT4 DNA: RACE

Purpose: The objective of the RACE project is to develop a comparison between Monte Carlo simulation using the Geant4-DNA toolkit and measurements of radiation damage on 3D melanoma and chondrosarcoma culture cells coupled with gadolinium nanoparticles. We currently expose the status of the developments regarding simulations. Methods: Monte Carlo studies are driven using the Geant4 toolkit and the Geant4-DNA extension. In order to model the geometry of a cell population, the opensource CPOP++ program is being developed for the geometrical representation of 3D cell populations including a specific cell mesh coupled with a multi-agent system. Each cell includes cytoplasm and nucleus. The correct modeling of the cell population has been validated with confocal microscopy images of spheroids. The Geant4 Livermore physics models are used to simulate the interactions of a 250 keV X-ray beam and the production of secondaries from gadolinium nanoparticles supposed to be fixed on the cell membranes. Geant4-DNA processes are used to simulate the interactions of charged particles with the cells. An atomistic description of the DNA molecule, from PDB (Protein Data Bank) files, is provided by the so-called PDB4DNA Geant4 user application we developed to score energy depositions in DNA base pairs and sugar-phosphate groups. Results: At the microscopic level, our simulations enable assessing microscopic energy distribution in each cell compartment of a realistic 3D cell population. Dose enhancement factors due to the presence of gadolinium nanoparticles can be estimated. At the nanometer scale, direct damages on nuclear DNA are also estimated. Conclusion: We successfully simulated the impact of direct radiations on a realistic 3D cell population model compatible with microdosimetry calculations using the Geant4-DNA toolkit. Upcoming validation and the future integration of the radiochemistry module of Geant4-DNA will propose to correlate clusters of ionizations with in vitro experiments. All those developments will be released publicly. This work was supported by grants from Plan Cancer 2009-2013 French national initiative managed by INSERM (Institut National de la Sante et de la Recherche Medicale)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP3-05: In Vitro Demonstration of Endothelial Dose Enhancement Due to Gold Nanoparticles During Low-Voltage Radiotherapy

Purpose: Oraya Therapy uses low-voltage, stereotactic, highly targeted X-rays for the treatment of wet age-related macular degeneration (AMD) — offering a new option for patients worldwide. Neovascular endothelial cells play a crucial role in the pathogenesis of this disease. This in-vitro study investigates the potential of gold nanoparticles (GNP) to enhance endothelial cell damage during low-voltage radiotherapy towards potential applications in the treatment of wet-AMD. Methods: Primary human umbilical cord vein endothelium cells (HUVEC) were treated with 1.4 nm sized GNPs for 24 hrs and then irradiated with variable X-ray doses using an Oraya therapy system (100 kVp) or a Small Animal Radiation and Research platform (SARRP) at other beam qualities (up to 220 kVp). Radio-sensitization was assessed by clonogenic assays. Variable concentrations of GNPs (0.05 mg/ml, 0.1 mg/ml, 0.25 mg/ml, 0.5 mg/ml, and 1 mg/ml) where employed. The dose enhancement factor (DEF) was calculated as the ratio of radiation doses required to give the same biological effect (survival factor, SF) with and without GNPs. Results: Preliminary results show DEFs of up to 2.62 for the different combinations of x-ray doses and GNP concentrations and beam qualities. In general the DEF increased with increase in GNP concentration. However, for high doses the effect of GNP becomes less apparent likely due to already high cell kill by the radiation alone. Conclusion: The findings suggest that targeted GNPs can play a significant synergistic role in enhancing stereotactic radiosurgery for wet AMD. The results also provide impetus for ongoing studies to find the optimal synergy between the doses or beam energies and GNPs concentration. This will benefit in-vivo studies towards development of nanoparticle-aided radiotherapy for treatment of wet-AMD and potentially ocular cancers.

60 APPLIED LIFE SCIENCES↗

Thermodynamic assessment of the quaternary WTaCrV refractory high entropy alloy as a means to guide experimental approaches

The deployment of fusion energy poses challenges for materials in plasma facing components to withstand high temperatures and thermal gradients, particle implantation and neutron damage. The current material of choice is tungsten, although property degradation limits its consideration in future fusion reactors. Hence, materials with better resistance to harsh environments need to be developed for fusion energy to become a reality. High entropy alloys are being explored as potential candidates with some compositions showing good radiation resistance to defect cluster formation. One of these materials is the WTaCrV system, although only one composition has been tested under ion irradiation. In this work, we study the thermodynamic properties of the entire quaternary alloy composition range. Coupling first principles calculations, cluster expansion approaches, and Monte Carlo methods, we access the free energy functionals, short-range ordering as a function of temperature, and atomic configurations that can be compared to experimental observations. We use this data to inform experiments into compositions with higher propensity to form solid solutions, instead of phase separating. With this formalism we have developed thermodynamic database (TDB) files that can be used to plot quaternary phase diagrams.

Cluster Expansion↗

Effect of the light spectrum of various substrates for inkjet printed conductive structures sintered with intense pulsed light

In this work, the novel method of intense pulsed light (IPL) sintering of a nanoparticle silver ink is presented. Various patterns are printed with the Inkjet technology on two flexible foils with different light spectra. One is a clear Polyethylenterephthalat [PET] foil and the second is a light brownish Polyimide [PI] foil. The samples are flashed with different parameters regarding to pulse intensity and pulse length. Microscopic images are indicating the impact of the flashing parameters and the different light spectra of the substrates on the sintered structures. Sheet and line resistance are measured and the conductivity is calculated. A high influence of the property of the substrate with respect to light absorption and thermal conductivity on the functionality of printed conductive structures could be presented. With this new method of IPL sintering, highly conductive inkjet printed silver patterns could be manufactured within milliseconds on flexible polymeric foils without damaging the substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Targeting mitochondria in cancer cells using gold nanoparticle-enhanced radiotherapy: A Monte Carlo study

Purpose: Radiation damage to mitochondria has been shown to alter cellular processes and even lead to apoptosis. Gold nanoparticles (AuNPs) may be used to enhance these effects in scenarios where they collect on the outer membranes of mitochondria. A Monte Carlo (MC) approach is used to estimate mitochondrial dose enhancement under a variety of conditions. Methods: The PENELOPE MC code was used to generate dose distributions resulting from photons striking a 13 nm diameter AuNP with various thicknesses of water-equivalent coatings. Similar dose distributions were generated with the AuNP replaced by water so as to estimate the gain in dose on a microscopic scale due to the presence of AuNPs within an irradiated volume. Models of mitochondria with AuNPs affixed to their outer membrane were then generated—considering variation in mitochondrial size and shape, number of affixed AuNPs, and AuNP coating thickness—and exposed (in a dose calculation sense) to source spectra ranging from 6 MV to 90 kVp. Subsequently dose enhancement ratios (DERs), or the dose with the AuNPs present to that for no AuNPs, for the entire mitochondrion and its components were tallied under these scenarios. Results: For a representative case of a 1000 nm diameter mitochondrion affixed with 565 AuNPs, each with a 13 nm thick coating, the mean DER over the whole organelle ranged from roughly 1.1 to 1.6 for the kilovoltage sources, but was generally less than 1.01 for the megavoltage sources. The outer membrane DERs remained less than 1.01 for the megavoltage sources, but rose to 2.3 for 90 kVp. The voxel maximum DER values were as high as 8.2 for the 90 kVp source and increased further when the particles clustered together. The DER exhibited dependence on the mitochondrion dimensions, number of AuNPs, and the AuNP coating thickness. Conclusions: Substantial dose enhancement directly to the mitochondria can be achieved under the conditions modeled. If the mitochondrion dose can be directly enhanced, as these simulations show, this work suggests the potential for both a tool to study the role of mitochondria in cellular response to radiation and a novel avenue for radiation therapy in that the mitochondria may be targeted, rather than the nuclear DNA.

60 APPLIED LIFE SCIENCES↗

First-principles calculations of solute transport in zirconium: Vacancy-mediated diffusion with metastable states and interstitial diffusion

Zirconium alloys are the most widely used nuclear fuel cladding materials for light water power reactors where irradiation damage causes solute redistribution, leading to degradation of alloy properties such as corrosion resistance. Designing radiation-tolerant zirconium alloys requires a thorough understanding of the atomic-scale transport behavior of the alloying elements in Zr. In this work, we perform density function theory calculations to investigate the diffusion of Sn, Cr, Fe, Be, Al, and Ni in the hexagonal close-packed (HCP) Zr matrix. We develop a methodology to accurately model the metastable vacancy states along the basal migration path, known to occur in group IV metals. We compute the vacancy-mediated solute diffusion coefficients and drag ratios using the kinetic Monte Carlo method and an analytic Green's function method—the agreement between the two validates our methodology. The computed diffusion coefficients of Sn and Al show good agreement with the experimental data and we expect these solutes to diffuse via the vacancy-mediated mechanism. We use a Green's function approach, parameterized with data from density functional theory calculations, to compute the interstitial diffusion coefficients of Cr, Fe, Be, and Ni in the HCP Zr lattice. The computed diffusion coefficients of Cr, Ni, and Be agree with the experimental measurements within one order of magnitude, while those of Fe are within two orders of magnitude of the experimental measurements. The drag ratios for Cr, Fe, Be, and Ni are positive up to 1235 K, which suggests that nonequilibrium vacancy fluxes could drag these solutes toward sinks such as dislocation loops and grain boundaries. We also compute the transport coefficients without including the metastable states, and using the eight- and thirteen-frequency model. Our results show significant differences in drag ratio for the eight- and thirteen-frequency model predictions compared with the Green's function methodology, but smaller errors in the solute diffusivity. Combining interstitial and vacancy-mediated diffusivities, we predict the unusual result that increased vacancy concentration slows down solute diffusivity, while a sufficiently high vacancy concentration can change the dominant mechanism to an accelerated vacancy-mediated diffusion.

36 MATERIALS SCIENCE↗

SU-E-T-279: Dose Enhancement Effect Due to Cerium Oxide Nanoparticles Employed as Radiation Protectants

Purpose: The goal of radiotherapy is to maximize radiation dose to diseased cells while minimizing radiation damage to normal tissues. In order to minimize damage to normal tissues, cerium oxide nanoparticles (nanoceria) are currently considered as a radioprotectant. However, some studies have reported concerns that nanoceria can also lead to radiotherapy dose enhancement due to the high atomic number of cerium, especially when used in conjunction with kV energy and brachytherapy sources. In this study, this concern is investigated to determine if the concentrations of nanoceria employed in in-vivo studies to confer radioprotection can engender a significant dose enhancement. Methods: Radiation with energies ranging from 50kVp to 140kVp is investigated in this work along with brachytherapy sources Pd-103 and I-125. A previously established theoretical model is used to calculate the dose enhancement factor (DEF). In this model, each cell is assumed to be a voxel of size (10 µm, 10 µm, 10 µm) with nanoceria homogeneously distributed among them. Electron energy loss formula of Cole is used to calculate energy (and hence dose) deposited by photoelectrons and Auger electrons in each tissue voxel due to irradiation of nanoceria. The DEF is defined as the ratio of the dose with and without nanoparticles. Results: DEF calculation results are smaller than 1.02 with dosages of nanoceria smaller than 0.645 mg/g, which is shown to be sufficiently protective by some previous in-vitro and in-vivo experiments. The brachytherapy sources show higher DEF’s than kVp radiations. DEF peaks are consistent with K shell and L shell energies of cerium, 40 keV and 6 keV, respectively. Conclusion: The results show that for sufficiently radioprotective concentrations of nanoceria, there will be minimal DEF when used in conjunction with clinically applicable kV energy radiotherapy sources or brachytherapy sources.

60 APPLIED LIFE SCIENCES↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Vacancy-driven variations in the phonon density of states of fast neutron irradiated nuclear graphite

Research examining radiation damage and its effects in graphite began in the 1940’s during the development of moderated nuclear reactors. Interest in this topic is expanding because of emerging applications associated with fullerenes and carbon nanostructures as well as its long-standing use as a fission moderator. In this work, we report the measurements of the full phonon density of states of irradiated nuclear graphite using inelastic neutron scattering experiments at room temperature. The samples were previously exposed to different levels of neutron doses and irradiation temperatures. The phonon density of states of perfect and defected graphite supercells including different configurations of vacancies and interstitials were calculated using first-principles direct method. Despite high neutron irradiation doses, the scattering measurements show that the induced damage is localized, and the layered structure is preserved. In conclusion, a comparison of the measured phonon densities of states of irradiated samples with those calculated of defected supercells indicates that the main changes observed are mainly attributed to formation of vacancies.

36 MATERIALS SCIENCE↗

Energetics of defects in b-SiC under irradiation

Energetics of point defects in b-SiC have been investigated using atomistic calculations with the empirical interatomic potential, where a simple static relaxation method and a dynamic relaxation method are separately employed. In addition to formation energy of isolated silicon interstitials, migration energies for interstitials and vacancies obtained from the dynamic relaxation method are much lower than those obtained from the simple static relaxation method. It indicates that the dynamic relaxation method possibly can provide more relaxed defect configuration than the simple static relaxation method.

36 MATERIALS SCIENCE↗

SU-F-T-193: Evaluation of a GPU-Based Fast Monte Carlo Code for Proton Therapy Biological Optimization

Purpose: Biological treatment plan optimization is of great interest for proton therapy. It requires extensive Monte Carlo (MC) simulations to compute physical dose and biological quantities. Recently, a gPMC package was developed for rapid MC dose calculations on a GPU platform. This work investigated its suitability for proton therapy biological optimization in terms of accuracy and efficiency. Methods: We performed simulations of a proton pencil beam with energies of 75, 150 and 225 MeV in a homogeneous water phantom using gPMC and FLUKA. Physical dose and energy spectra for each ion type on the central beam axis were scored. Relative Biological Effectiveness (RBE) was calculated using repair-misrepair-fixation model. Microdosimetry calculations were performed using Monte Carlo Damage Simulation (MCDS). Results: Ranges computed by the two codes agreed within 1 mm. Physical dose difference was less than 2.5 % at the Bragg peak. RBE-weighted dose agreed within 5 % at the Bragg peak. Differences in microdosimetric quantities such as dose average lineal energy transfer and specific energy were < 10%. The simulation time per source particle with FLUKA was 0.0018 sec, while gPMC was ∼ 600 times faster. Conclusion: Physical dose computed by FLUKA and gPMC were in a good agreement. The RBE differences along the central axis were small, and RBE-weighted dose difference was found to be acceptable. The combined accuracy and efficiency makes gPMC suitable for proton therapy biological optimization.

60 APPLIED LIFE SCIENCES↗

Development of Fusion Neutronics Methodology, Software, and Testing Facility in FDS Team

Fusion neutronics including methodology, software, experiments, etc. is studied concerning the generation, utilizing and protection of neutrons in fusion facilities. Achievements have been made in the past decades to solve the new problems fusion neutronics. However there is still some way to go such as following. Automatic modeling method based on CAD has been developed to avoid the heavy burden of manual geometry description. The pre-processing costs much time to simplify the CAD model for converting to Constructive Solid Geometry (CSG), 2D or 3D mesh based geometry. This problem has become a new focus. Deep penetration of radiation shielding is notable problem for fusion. Adaptive variance reduction methods such as Consistent Adjoint Driven Importance Sampling (CADIS) were developed to accelerate convergence. However the gap still exists between engineering requirements and current methodology. The geometry simplification, homogenizing based tally, error in nuclear data and error propagation in coupled calculation, etc., causes considerable uncertainty, which leads to 'safety factor' applied in simulation results to achieve required safety margin. It can significantly raise the cost and even makes it impractical to initiate the fusion facilities. Uncertainty qualification, error analysis and error propagation problem should be studied. New methodology and software should be validated. For example the (n,p), (n,a), (n,t) cross section of Cu, Fe, W, Ni which is important for evaluation of material radiation damage is absent. The validation of neutronics properties of special components such as first wall, blanket and coil are needed. The D-T fusion neutron generator can directly represent the neutron environment in fusion reactors. However the neutron yield is several orders of magnitudes lower than requirements. To resolve obstacles in fusion neutronics, broad improvements of methodology, software and testing facility have been achieved by FDS Team in recent years and the main progress was introduced in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of three dead detector correction methods for cone-beam computed tomography

Purpose: Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the three methods and establishing the conditions for which they fail. Methods: MVCBCT projections acquired with four linacs at 8 and 60 MU (monitor units) were degraded with varying percentages (2%-95%) of randomly distributed dead single detectors (RDSs), randomly distributed dead detector clusters (RDCs) of 2 mm diameter, and nonrandomly distributed dead detector disks (NRDDs) of varying diameter (4-16 mm). Correction algorithms were bidirectional linear interpolation (BLI), quad-directional linear interpolation (QLI), and a Laplacian solution (LS) method. Correction method failure was defined to occur if ring artifacts were present in the reconstructed phantom images from any linac or if the modulation transfer function (MTF) for any linac dropped below baseline with a p value, calculated with the two sample t test, of less than 0.01. Results: All correction methods failed at the same or lower RDC/RDS percentages and NRDD diameters for the 60 MU as for the 8 MU cases. The LS method tended to outperform or match the BLI and QLI methods. If ring artifacts anywhere in the images were considered unacceptable, the LS method failed for 60 MU at >33% RDS, >2% RDC, and >4 mm NRDD. If ring artifacts within 4 mm longitudinally of the phantom section interfaces were considered acceptable, the LS method failed for 60 MU at >90% RDS, >80% RDC, and >4 mm NRDD. LS failed due to MTF drop for 60 MU at >50% RDS, >25% RDC, and >4 mm NRDD. Conclusions: The LS method is superior to the BLI and QLI methods, and correction algorithm effectiveness decreases as imaging dose increases. All correction methods failed first due to ring artifacts and second due to MTF drop. If ring artifacts in axial slices within a 4 mm longitudinal distance from phantom section interfaces are acceptable, statistically significant loss in spatial resolution does not occur until over 25% of the EPID is covered in randomly distributed dead detectors, or NRDDs of 4 mm diameter are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Displacement Threshold Energy and Recovery in an Al-Ti Nanolayered System with Intrinsic Point Defect Partitioning

A method is established and validated using molecular dynamics (MD) to determine the displacement threshold energies as Ed in nanolayered, multilayered systems of dissimilar metals. The method is applied to specifically oriented nanolayered films of Al-Ti where the crystal structure and interface orientations are varied in atomic models and Ed is calculated. Methods for defect detection are developed and discussed based on prior research in the literature and based on specific crystallographic directions available in the nanolayered systems. These are compared and contrasted to similar calculations in corresponding bulk materials, including fcc Al, fcc Ti, hcp Al, and hcp Ti. In all cases, the calculated Ed in the multilayers are intermediate to the corresponding bulk values but exhibit some important directionality. In the nanolayer, defect detection demonstrated systematic differences in the behavior of Ed in each layer. Importantly, collision cascade damage exhibits significant defect partitioning within the Al and Ti layers that is hypothesized to be an intrinsic property of dissimilar nanolayered systems. This type of partitioning could be partly responsible for observed asymmetric radiation damage responses in many multilayered systems. In addition, a pseudo-random direction was introduced to approximate the average Ed without performing numerous simulations with random directions.

Al-Ti↗

Interaction of vacuum ultraviolet excimer laser radiation with fused silica. I. Positive ion emission

We report time- and mass-resolved measurements of Si{sup +} and O{sup +} emission from ultraviolet-grade fused silica during exposure to pulsed 157 nm excimer laser radiation at fluences below the threshold for optical breakdown. The emission intensities are increased by treatments that increase the density of surface defects, such as abrasion, and are reduced by treatments that reduce the density of surface defects, such as annealing. Ion emission is a sensitive probe of mechanical damage on silica surfaces. The mean ion kinetic energies are typically several eV: 8-9 eV for Si{sup +} and about 4 eV for O{sup +}. Hartree-Fock studies of candidate defect sites suggest that antibonding states excited by 157 nm photons play a critical role in the release of these ions. We propose that positive ion emission from fused silica under these conditions is best explained by a hybrid mechanism involving (a) the excitation of an antibonding chemical state (Menzel-Gomer-Redhead mechanism) and (b) the acceleration of the positive ion by repulsive electrostatic forces due to the photoionization of nearby electron traps.

74 ATOMIC AND MOLECULAR PHYSICS↗

Towards 3D printed multifunctional immobilization for proton therapy: Initial materials characterization

Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-specific structure. In this first step, a set of 3D printed materials is characterized in detail, in terms of structural and radiological properties, elemental composition, directional dependence, and structural changes induced by radiation damage. These data will serve as inputs for the design of 3D printed immobilization structure prototypes. Methods: Using four different 3D printing techniques, in total eight materials were subjected to testing. Samples with a nominal dimension of 20 × 20 × 80 mm{sup 3} were 3D printed. The geometrical printing accuracy of each test sample was measured with a dial gage. To assess the mechanical response of the samples, standardized compression tests were performed to determine the Young’s modulus. To investigate the effect of radiation on the mechanical response, the mechanical tests were performed both prior and after the administration of clinically relevant dose levels (70 Gy), multiplied with a safety factor of 1.4. Dual energy computed tomography (DECT) methods were used to calculate the relative electron density to water ρ{sub e}, the effective atomic number Z{sub eff}, and the proton stopping power ratio (SPR) to water SPR. In order to validate the DECT based calculation of radiological properties, beam measurements were performed on the 3D printed samples as well. Photon irradiations were performed to measure the photon linear attenuation coefficients, while proton irradiations were performed to measure the proton range shift of the samples. The directional dependence of these properties was investigated by performing the irradiations for different orientations of the samples. Results: The printed test objects showed reduced geometric printing accuracy for 2 materials (deviation > 0.25 mm). Compression tests yielded Young’s moduli ranging from 0.6 to 2940 MPa. No deterioration in the mechanical response was observed after exposure of the samples to 100 Gy in a therapeutic MV photon beam. The DECT-based characterization yielded Z{sub eff} ranging from 5.91 to 10.43. The SPR and ρ{sub e} both ranged from 0.6 to 1.22. The measured photon attenuation coefficients at clinical energies scaled linearly with ρ{sub e}. Good agreement was seen between the DECT estimated SPR and the measured range shift, except for the higher Z{sub eff}. As opposed to the photon attenuation, the proton range shifting appeared to be printing orientation dependent for certain materials. Conclusions: In this study, the first step toward 3D printed, multifunctional immobilization was performed, by going through a candidate clinical workflow for the first time: from the material printing to DECT characterization with a verification through beam measurements. Besides a proof of concept for beam modification, the mechanical response of printed materials was also investigated to assess their capabilities for positioning functionality. For the studied set of printing techniques and materials, a wide variety of mechanical and radiological properties can be selected from for the intended purpose. Moreover the elaborated hybrid DECT methods aid in performing in-house quality assurance of 3D printed components, as these methods enable the estimation of the radiological properties relevant for use in radiation therapy.

60 APPLIED LIFE SCIENCES↗