Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Source Replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Analysis of RF high power sources for 1MW – range, 10 MeV CW industrial accelerator.

Cobalt-60 is the dominant source of ionizing radiation for sterilizing products in the $200B/year medical device industry. Security and accessibility concerns around this radioactive material - sourced from countries including Russia and China - present national security and economic risks. There is a continued national urgency to replace such high-risk sources with low-risk alternatives such as electron or x-ray beams driven by accelerators. While e-beam sources have been in use for many years, they still represent a small portion of the market. X-ray sources are becoming economical alternatives. Meeting the processing capacity required to replace Co-60 requires a step-change in the capability, efficiency, and overall operating cost of electron accelerators to make adoption feasible. The radiofrequency (RF) power that drives accelerating cavities represents significant capital and operating costs for these accelerators. For accelerator-based systems to be a viable alternative for these applications, RF systems must be economical to manufacture, deploy, and operate.

43 PARTICLE ACCELERATORS↗

Experience with Inner Reflector Plug exchange in SNS

The Inner Reflector Plug (IRP) is a central component of the Spallation Neutron Source target monolith, which houses the mercury target and four liter-sized neutron moderator units. It is exposed to high-level radiation fields during routine operation and builds up significant activity. The IRP needs to be replaced due to moderator neutron poison and decoupler burn-out, which is used for shaping neutron pulses. The first IRP exchange took place in March 2018. The old IRP was extracted from the target monolith, providing space for the new one. It was split into three segments, each of which was handled separately. The lowest section of the IRP is the largest segment in size and in activity and is temporarily stored on-site for cool down before conduction post irradiation examination. In support of planning the replacement activities, a wide range of activation and transport analyses were performed. This included calculating isotope inventories and the radiation fields for each segment as it is extracted in storage casks, and the radiation field from the empty IRP pit in the target monolith. While the replacement was taking place, measurements were performed and later on compared to the calculations. During these studies, it was discovered that a significant contributor to the radiation field from the lower IRP segment is from photo-neutrons. Photo-nuclear physics was added to the analyses and calculated results compared well with measured dose rates.

Popova, Irina I.↗

A Technical basis for in-house calibration of 252 Cf neutron source emission rates

10CFR835 stipulates that radiation protection instruments must be calibrated at least annually. Accordingly, calibration of dose rate instruments are reliant on well-known reference fields. The neutron-free-in-air facility (NFIA) located at TA36-0214 provides such a capability for neutron remmeters. One of the reference NFIA sources, 252 Cf, must be replaced every 8-10 years due to its relatively short half-life (2.645 ± 0.008 y). In the past, each newly purchased 252 Cf source has been calibrated at NIST using the Mn-bath technique prior to shipping to LANL. However, because of COVID-19 complications, the most recently acquired 252 Cf source (FTC-CF-7167) has been stored at LANL pending approval to ship to NIST for calibration. Due to the considerable expense in transporting the source to and from NIST, this TBD was written to demonstrate that new sources can be accurately calibrated via intercomparison measurements with older NIST-calibrated 252 Cf sources. It had been previously noted that such measurements yielded emission rates that agreed very well with the official rates established by NIST

252cf↗

Isotope Production at the Jefferson Lab LERF Facility (Final Report)

The project initially proceeded well, meeting all of the Milestones. However, the need to create a new irradiation area in the LERF (the initial proposal was to use the CEBAF Injector) used up a larger fraction of the budget than foreseen. A further problem arose when the hot-cell became unavailable at VCU, followed by VCU dropping out of the collaboration. This meant that we were unable to separate the 67 Cu from the gallium. We replaced this by carrying out detailed gamma spectroscopy to determine the quantity of 67 Cu produced.

07 ISOTOPE AND RADIATION SOURCES↗

A new numerical model of the middle atmosphere. I - Dynamics and transport of tropospheric source gases

Attention is given to a new model of the middle atmosphere which includes, in addition to the equations governing the zonal mean state, a potential vorticity equation for a single planetary-scale Rossby wave, and an IR radiative transfer code for the stratosphere and lower mesosphere, which replaces the Newtonian cooling parameterization used previously. It is shown that explicit computation of the planetary-scale wave field yields a more realistic representation of the zonal mean dynamics and the distribution of trace chemical species. Wave breaking produces a well-mixed 'surf zone' equatorward of the polar night vortex and drives a meridional circulation with downwelling on the poleward side of the vortex. This combination of mixing and downwelling produces shallow meridional gradients of trace gases in the subtropics and middle latitudes, and very steep gradients at the edge of the polar vortex. Computed distributions of methane and nitrous oxide are shown to agree well with observations.

Garcia, Rolando R.↗

Solar Wind Ablation of Terrestrial Planet Atmospheres

Internal plasma sources usually arise in planetary magnetospheres as a product of stellar ablation processes. With the ignition of a new star and the onset of its ultraviolet and stellar wind emissions, much of the volatiles in the stellar system undergo a phase transition from gas to plasma. Condensation and accretion into a disk is replaced by radiation and stellar wind ablation of volatile materials from the system- Planets or smaller bodies that harbor intrinsic magnetic fields develop an apparent shield against direct stellar wind impact, but UV radiation still ionizes their gas phases, and the resulting internal plasmas serve to conduct currents to and from the central body along reconnected magnetic field linkages. Photoionization and thermalization of electrons warms the ionospheric topside, enhancing Jeans' escape of super-thermal particles, with ambipolar diffusion and acceleration. Moreover, observations and simulations of auroral processes at Earth indicate that solar wind energy dissipation is concentrated by the geomagnetic field by a factor of 10-100, enhancing heavy species plasma and gas escape from gravity, and providing more current carrying capacity. Thus internal plasmas enable coupling with the plasma, neutral gas and by extension, the entire body. The stellar wind is locally loaded and slowed to develop the required power. The internal source plasma is accelerated and heated, inflating the magnetosphere as it seeks escape, and is ultimately blown away in the stellar wind. Bodies with little sensible atmosphere may still produce an exosphere of sputtered matter when exposed to direct solar wind impact. Bodies with a magnetosphere and internal sources of plasma interact more strongly with the stellar wind owing to the magnetic linkage between the two created by reconnection.

Moore, Thomas Earle↗

SU-E-T-576: Evaluation of Patient Specific VMAT QA Using Dynalog Files and Treatment Planning System

Purpose: This research investigates the use of Mult-ileaf Collimator (MLC) dynalog files to modify a Volumetric Arc Therapy (VMAT) DICOM Radiotherapy Treatment file from the Treatment Planning System (TPS) for quality assurance and treatment plan verification. Methods: Actual MLC positions and gantry angles where retrieved from the MLC Dynalog files of an approved and treated VMAT plan. The treatment machine used was a Novalis TX linac equipped with high definition MLC. The DICOM RT file of the plan was exported from the TPS (Eclipse, Varian Medical Systems) and the actual MLC leaf positions and gantry angles were inserted in place of the planned positions for each control point. The modified DICOM RT file was then imported back into the TPS where dose calculations were performed. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% and 2mm-2% criteria. A 2D gamma was also calculated using dose measurements on the Delta4 (Sandidose) phantom. Results: A 3D gamma was calculated in Verisoft at 3mm-3% of 99.5% and at 2mm-2% of 99.2%. The pretreatment verification on the Delta4 yielded a 2D gamma at 3mm-3% of 97.9% and at 2mm-2% of 88.5%. The dose volume histograms of the approved plan and the dynalog plan are virtually identical. Conclusion: Initial results show good agreement of the dynalog dose distribution with the approved plan. Future work on this research will aim to increase the number of patients and replace the planned fractionated dose per control point with the actual fractionated dose.

07 ISOTOPE AND RADIATION SOURCES↗

Distributed Automatic Differentiation for Ptychography

Synchrotron radiation light source facilities are leading the way to ultrahigh resolution X-ray imaging. High resolution imaging is essential to understanding the fundamental structure and interaction of materials at the smallest length scale possible. Diffraction based methods achieve nanoscale imaging by replacing traditional objective lenses by pixelated area detectors and computational image reconstruction. Among these methods, ptychography is quickly becoming the standard for sub-30 nanometer imaging of extended samples, but at the expense of increasingly high data rates and volumes. This paper presents a new distributed algorithm for solving the ptychographic image reconstruction problem based on automatic differentiation. Input datasets are subdivided between multiple graphics processing units (GPUs); each subset of the problem is then solved either entirely independent of other subsets (asynchronously) or through sharing gradient information with other GPUs (synchronously). The algorithm was evaluated on simulated and real data acquired at the Advanced Photon Source, scaling up to 192 GPUs. The synchronous variant of our method outperformed an existing multi-GPU implementation in terms of accuracy while running at a comparable execution time.

distributed algorithms↗

A New Vision and A More Rational Process Will Advance Space Life Support Through Better Projects

Many space life support assumptions are obviously mistaken but they are generally accepted because they mutually support each other and because they advance a mistaken futuristic vision of closed human ecosystems in space. Many projects have been mistakenly selected to increase life support system closure or reduce launch mass in order to implement this impractical vision. Project members rarely challenge their project’s assumptions and guiding vision. Systems engineering including cost, reliability, risk, and system trade-offs has been very strongly discouraged to prevent rational criticism of these dubious assumptions, the projects, and the ecosystem vision. A more realistic vision can define better near term life support goals and future aspirations that will improve mission support and increase public interest. Given more realistic goals, it will be possible to develop effective technical alternatives, use open rational project selection methods, conduct professional project management, and make swifter progress in the inevitable human advance into space. The current unworkable human space settlement scenario involves moon visits and permanent bases, zero gravity trips to Mars, Mars visits and bases, all leading to extensive human settlements on the moon and Mars. This is unrealistic because the moon and Mars have less than Earth normal gravity and high radiation that can seriously damage human health. A better alternative would use rotating space colonies that produce Earth gravity and are radiation shielded. The attractive fantasy of reproducing terrestrial ecology in space should be replaced by the idea of building a closed system based on advancing technology such as artificial photosynthesis. Past mistaken projects include growing plants for food to replicate terrestrial food sources, recovering small amounts of water from difficult to process waste to achieve high system closure, and using newly designed, lighter, but unreliable hardware to reduce launch mass. The political process supporting the false assumptions, projects, and vision has deliberately prevented the usual systems engineering and cost-benefit analysis. We are going to do much better.

Harry W. Jones↗

Electrodeposition and analysis of thick bismuth films

Due to its unique physical and chemical properties, bismuth is an attractive candidate for a wide range of applications such as battery anodes, radiation shielding, and semiconductors, to name a few. This work presents the electrodeposition of mechanically stable and homogenous bismuth films at micron-scale thicknesses. A simple one-step electrodeposition process using either a pulse/reverse or direct current source yielded thick, homogenous, and mechanically stable bismuth films. Morphology, electrochemical behavior, adhesion, and mechanical stability of bismuth coatings plated with varying parameters were characterized via optical profilometry, cyclic voltammetry, electron microscopy, and tribology. Scratch testing on thick electroplated coatings (> 100 µm) revealed similar wear resistance properties between the pulse/reverse plated and direct current electroplated films. This study presents a versatile bismuth electroplating process with the possibility to replace lead in radiation shields with an inexpensive, non-toxic metal, or to make industrially relevant electrocatalytic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Constellation's best estimate alternate source term methodology overview

Safety analyses for a nuclear power plants need to consider postulated accidents that results in at risk of accidental release of radiation. The regulations require plant specific safety analysis reports to include an evaluation of the requirements of 10CFR50.67. Such a safety analysis report mandates limits such that calculated radiological consequences relative to certain dose locations do not exceed a total effective dose equivalent (TEDE) limits following a postulated release of radioactivity. Calculations are performed to estimate the radiological consequences, in terms of dose, to people and equipment to ensure the estimated doses are within the prescribed limits. Analysis should demonstrate, with reasonable assurance, that these prescribed limits are complied with. Conventional methodologies utilize conservative approaches to address lack of uncertainty quantification in the utilized approaches, methods, and/or inputs. These built-in excess conservatisms often result in compounding effects and hence overly conservative results in the estimated radiological consequences, which leads to inaccurate margin evaluation for operation and accident mitigation. Therefore, evaluating accurate dose consequences is needed for both operational and safety reasons. The research documented in this paper provides an overview of Constellation's Best Estimate Alternate Source Term (BEAST) Methodology. BEAST methodology relies upon the use of realistic yet bounding input distributions for key analysis parameters, which replaces use of conservative deterministic singular inputs that bound overall analysis domain. This approach enables evaluating a more accurate accident analysis response, while enabling a bounding licensing basis envelope via more accurate quantification of uncertainty in the application. Therefore, built-in margin for a given scenario is more accurately evaluated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The ISS 2B PVTCS Ammonia Leak: An Operational History

In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS‐134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid‐2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, an EVA was in progress to replace the coolant pump - the only other replaceable leak source. This paper will explore the management of the 2B PVTCS leak from the operations perspective. It will discuss the methodology of performing the STS‐134 refill, the considerations and contingency plans which went into the architectural overhaul of the system in 2012, and the unprecedented effort which went into the EVA response to the visible leak of May 2013. In particular the paper will focus on the techniques utilized by flight controllers to monitor the system health and to respond to such instances as the rapid May 2013 leak by putting the electrical system in a safe configuration for loss of cooling, and will use recorded telemetry of these events to describe system response to EVA crew and ground actions. It will discuss the innovative design for redundancy of the integrated truss structure's cooling systems which allowed for this leak to be managed with minimal impact to other ISS operations and electrical services, contrasted against the real unintended operations consequences of utilizing the flexibility of the spacecraft's design in this manner. The paper will discuss how the training of the crew and flight controller personnel has adapted to the changing architecture of the power system and the unpredictable nature of the 2B leak.

Vareha, Anthony↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

SU-E-T-149: Electron Beam Profile Differences Between Elekta MLCi2 and Elekta Agility Treatment Heads

Purpose: To report and investigate observed differences in electron beam profiles at various energies/applicators between Elekta MLCi2 and Agility treatment head on Elekta Infinity LINAC Methods: When we upgraded from MLCi2 to Agility on one of our Elekta Infinity LINAC's, electron beam PDDs and profiles were acquired for comparison purpose. All clinical electron energies (6/9/12/15/12/18 MeV) and electron applicators (6/10/14/20/25 square) were included in measurement. PDDs were acquired at 100 SSD in water (PTW MP3 water tank) with a plane-parallel ion chamber (PTW Roos). X and Y Profiles were acquired using IC Profiler (Sun Nuclear Corp.) at 1cm and maximum PDD depths (water equivalent). Results: All PDD curves match very well between MLCi2 and Agility treatment head. However, some significant differences on electron profiles were found. On Agility, even after increasing the default auto-tracking offset values for backup diaphragms in Y and MLC in X by 2.8 cm (the maximum allowed change is 3.0 cm), electron profiles still have rounder shoulders comparing to corresponding MLCi2 profiles. This difference is significantly more pronounced at larger applicators (20 and 25 square), for all electron energies. Conclusion: The significant design change between MLCi2 and Agility beam limiting device seems to affect exit electron beam profiles. In IEC1217 X direction, the main change on Agility is the removal of the original MLCi2 X backup diaphragms and replacing it with MLC leaves; In Y direction, the main change is the radius and materials on Y backup diaphragms.

07 ISOTOPE AND RADIATION SOURCES↗

Solar thermoelectric power generation for Mercury orbiter missions

Mercury orbiter mission study results have shown that conventional silicon solar cell array technology is not adequate to produce power because of expected temperatures which range from -90 C to +285 C in about 50 minutes for 16 sun eclipses/day. The solar thermoelectric generator (STG), which requires relatively high temperatures, is being developed as a replacement power source. Several thermoelectric technologies (i.e., lead telluride alloys, bismuth telluride, selenide, and silicon-germanium alloys have been examined for their suitability. Solar concentrator configurations (i.e., flat plate, Fresnel lens, mini-cone, and Cassegrain types) were also studied as candidates for increasing incident radiation during Mercury orbital operations. Detailed results are presented, and show that an STG design based on the use of silicon-germanium alloy thermoelectric material and using high-voltage thermopiles with individual miniconical concentrators presents the optimum combination of technology and configuration for minimizing power source mass.

Swerdling, M.↗

Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source

Purpose: To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent{sup Registered-Sign} Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Methods: Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. Results: The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy/min while the RT-50 is 10-12 Gy/min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately {+-}5.2%. Conclusions: The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

60 APPLIED LIFE SCIENCES↗