Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Transport Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For lower energy radionuclides like {sup 169}Yb, bolus may be needed; and (iii) for the interstitial case, at least a 0.1 cm bolus is advised for {sup 60}Co to avoid underdosing superficial target layers. For {sup 192}Ir and {sup 169}Yb, no bolus is needed. For those cases where no bolus is needed, its use might be detrimental as the lack of radiation scatter may be beneficial to the patient, although the 2% tolerance for dose calculation accuracy recommended in the AAPM TG-56 report is not fulfilled.

61 RADIATION PROTECTION AND DOSIMETRY↗

Initial Neutronics and Thermal-Hydraulic Coupling for Spent Nuclear Fuel Canister

This report documents work performed supporting the US Department of Energy (DOE) Nuclear Energy Spent Fuel and Waste Disposition, Spent Fuel and Waste Science and Technology, under work breakdown structure element 1.08.01.03.05, “Direct Disposal of Dual Purpose Canisters.” In particular, this appendix fulfills the M3 milestone, M3SF-19OR010305015, “Multiphysics criticality consequence analysis capability development status report,” as Revision 1 to M3SF-19OR010305016, “Initial neutronic and thermal hydraulic coupling for waste package” within work package SF-19OR01030501, “Direct Disposal of Dual Purpose Canisters–ORNL.” This report presents the initial development status of a multiphysics criticality consequence simulation framework, Terrenus. Terrenus currently couples two physics codes: the Monte Carlo radiation transport code Shift and the thermal-hydraulics code COBRA-SFS. The coupling capability has been demonstrated using a simplified 3 x 3 fuel pin lattice. Terrenus will be developed further to include (1) general geometry package support, allowing modeling of a spent nuclear fuel (SNF) cask with all structural details, (2) a depletion solver to determine the change in nuclide composition at the end of each time step, and (3) a mechanics code to determine any structural impact due to a criticality event. Future research and development works include identifying/developing a modern two-phase thermal-hydraulics code and developing an approach to solve fast neutronic transients. The goal of this multiphysics framework is to determine the feasibility of direct disposal of currently loaded SNF canisters by including or excluding a criticality event from a repository performance analysis framework in terms of consequences. The revision 1 to this report includes extending Terrenus to a 17 x 17 pressurized water reactor (PWR) fuel assembly. We also investigated the phenomena necessary to quench a critical reaction, and investigated the water level necessary to achieve criticality in a typical canister. Finally, we describe the initial implementation of a critical power search capability.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of dosimetry from the H.B. Robinson unit 2 pressure vessel benchmark using RAPTOR-M3G and ALPAN

Document available in abstract form only, full text of document follows: The dosimetry from the H. B. Robinson Unit 2 Pressure Vessel Benchmark is analyzed with a suite of Westinghouse-developed codes and data libraries. The radiation transport from the reactor core to the surveillance capsule and ex-vessel locations is performed by RAPTOR-M3G, a parallel deterministic radiation transport code that calculates high-resolution neutron flux information in three dimensions. The cross-section library used in this analysis is the ALPAN library, an Evaluated Nuclear Data File (ENDF)/B-VII.0-based library designed for reactor dosimetry and fluence analysis applications. Dosimetry is evaluated with the industry-standard SNLRML reactor dosimetry cross-section data library. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent Advances in the Use of TRIPOLI-4 Monte Carlo Code for Radiation Protection and Shielding Calculations - Paper 47

TRIPOLI-4 is a general purpose radiation transport code. It uses the continuous-energy Monte Carlo method to simulate neutron, photon, electron and positron transport in three-dimensional geometries. The main application areas of TRIPOLI-4 code include radiation protection and shielding, fission reactor physics, nuclear criticality safety, fusion reactor design, and nuclear instrumentation. For the radiation protection and shielding calculations with TRIPOLI-4 code, miscellaneous radiation sources options, various variance reduction options, and many useful tally options are available. Perturbation calculations on material densities and nuclide concentrations are routinely used in radiation protection applications. Parallel calculations with TRIPOLI-4 are also easy to perform with a PC under the linux/unix OS. To help the users to get the feedback from their test runs during the input data preparation and adjustment and to analyze the intermediate and final results from their production runs, several user-interface tools have been introduced. By using some application cases in the fields of radiation shielding, radiation dosimetry, and gamma spectrometry, this paper summarizes and demonstrates some essential improvements and possibilities in the use of TRIPOLI-4 code on fixed source calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Progenitors of Superluminous Type Ia Supernovae

Abstract Recent observations of type Ia supernovae (SNe Ia) have discovered a subclass of “super-Chandrasekhar” SNe Ia (SC SNe Ia) whose high luminosities and low ejecta velocities suggest that they originate from the explosions of white dwarfs (WDs) with masses that exceed the Chandrasekhar mass limit. Different models have been proposed to explain the progenitors of these explosions, including a “magnetized WD” model and a “WD merger” model. To test the robustness of these models, we conduct a 1D numerical parameter survey of WD explosions using these models as initial conditions. We follow the explosions using the hydrodynamics code Castro and then use the radiation transport code SuperNu to create light curves and spectra for the models. We find that while both classes of models fall within the range of SC SNe Ia observations on the light-curve width–luminosity relation, only the WD merger models reproduce the observed low ejecta velocities. The light curves of our merger models are more similar photometrically to observations than our magnetized models. Given this, we discuss possible explanations for the brightest SC SNe Ia observations that cannot be reproduced with our WD merger models. This study provides the basis for future SC SNe Ia observations and higher-dimensional numerical models.

79 ASTRONOMY AND ASTROPHYSICS↗

Specializations in the SCEPTRE code for charged-particle transport - 25454

Charged particles present some unique challenges for radiation transport codes. This is because charged particles have cross sections that are extremely forward peaked, are huge in the limit of small energy transfer, and are highly scattering, which causes slow convergence of the source iterations. The primary application of SCEPTRE is modeling radiation-driven electrical effects, so substantial effort has been invested in SCEPTRE for the efficient modeling of electron transport. This paper will summarize recent and ongoing activities involving the accurate deterministic-transport modeling of charged particles and methods implemented to improve iterative convergence. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

An improved methodology for modeling short pulse buried layer x-ray emission spectra

Radiation-hydrodynamic and spectroscopic modeling are important aspects of high energy density experimental design. In this paper, we improve the performance and capabilities over those obtainable with a previous methodology used for simulating x-ray emission spectra from buried layer targets heated by short pulse lasers. The improvement incorporates post-processing HYDRA radiation-hydrodynamic output with a non-local thermodynamic equilibrium atomic-kinetics radiation transport code, Cretin. Each code uses an independent radiation field which allows decoupling HYDRA's radiation group structure from Cretin's spectral output to improve the speed and flexibility of the design methodology. The execution time decreases from 2–3 days to a few hours while the flexibility of the improved methodology allows for performing sensitivity studies including a comparison of steady-state and time-dependent atomic kinetics and differences in the radiation group structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fixed Source Sensitivity Calculations for Inertial Confinement Fusion Applications

A numerical code library was developed for the radiation transport code MCNP6.3 to calculate generalized response sensitivity coefficients for fixed source neutron transport problems with applications to inertial confinement fusion (ICF) experiments. The new MCNP6.3 dependency is used to generate a novel time convolution response that represents a neutron time-of-flight (nToF) signal. The traditional suite of macroscopic cross-section sensitivities and constrained fixed source probability distribution sensitivities are available for both the standard and the new response tallies in this library. However, novel sensitivity coefficients for the constrained hyperparameters of analytic fixed source probability distributions are emphasized in this work for their connection to ICF neutron transport models. Particularly, advanced Monte Carlo methods are developed for calculating the sensitivity of a nToF signal to perturbations in an ICF plasma’s ion temperature and burn history as well as perturbations in the target liner mass density and the shape parameters of the nToF detector’s impulse response function. Together, these capabilities form an advanced suite of computational tools that can be used to analyze and extract information from any ICF experimental platform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computational Astrophysics Consortium (2006 - 2013)

The Computational Astrophysics Consortium was a SciDAC Science Application Project that operated during the period 2006 - 2013. The collaboration was headed by Stan Woosley at UC Santa Cruz, and (initially) included partners at UC Berkeley (UCB), LLNL, LANL, LBNL, Stonybrook, Arizona, Stanford, and Johns Hopkins. This report summarizes activities at UCB over the project period. More detailed information about the project accomplishments can be found in the collaboration final report submitted by PI Stan Woosley, and attached to this document. The CAC effort at UCB was originally led by PI Chris Mckee, and included participating faculty members Jon Arons, Peter Nugent, and Eliot Quataert. In 2010, Daniel Kasen moved from UCSC to a faculty position at UCB, and took over as UCB institution PI. The project supported several graduate students (Michael Childress, Siva Dharba, Andrew Myers, Janos Botyanszki, Jeffery Silverman) and postdocs (Dovi Poznanski, Antonino Cucchiarra, Jeffrey Oishi, Bradley Cenko, Eric Hsiao and Jason Dexter). Several codes were further developed by the UCB CAC group. The Orion code is a 3-dimensional radiation hydrodynamics code, used by McKee’s group and often applied to problems in star formation. As part of the CAC, an adaptive ray tracing ionization scheme was implemented, and a chemistry solver was incorporated for coupling the ionization state of the gas to its thermodynamics. The Sedona code is 3-dimensional monte carlo radiation transport code for calculation the light curves and spectra. As part of the CAC, the physics of the code was improved and domain decomposition techniques were implemented for scaling on massively parallel systems.

79 ASTRONOMY AND ASTROPHYSICS↗

VERIFICATION OF THE SHIFT MONTE CARLO CODE

Shift is a new hybrid Monte Carlo/deterministic radiation transport code being developed at Oak Ridge National Laboratory. At its current stage of development, Shift includes a fully-functional parallel Monte Carlo capability for simulating eigenvalue and fixed-source multigroup transport problems. This paper focuses on recent efforts to verify Shift s Monte Carlo component using the two-dimensional and three-dimensional C5G7 NEA benchmark problems. Comparisons were made between the benchmark eigenvalues and those output by the Shift code. In addition, mesh-based scalar flux tally results generated by Shift were compared to those obtained using MCNP5 on an identical model and tally grid. The Shift-generated eigenvalues were within three standard deviations of the benchmark and MCNP5 values in all cases. The flux tallies generated by Shift were found to be in very good agreement with those from MCNP

42 ENGINEERING↗

MCNP and GADRAS Comparisons

To facilitate the timely execution of System Threat Reviews (STRs) for DNDO, and also to develop a methodology for performing STRs, LANL performed comparisons of several radiation transport codes (MCNP, GADRAS, and Gamma-Designer) that have been previously utilized to compute radiation signatures. While each of these codes has strengths, it is of paramount interest to determine the limitations of each of the respective codes and also to identify the most time efficient means by which to produce computational results, given the large number of parametric cases that are anticipated in performing STR's. These comparisons serve to identify regions of applicability for each code and provide estimates of uncertainty that may be anticipated. Furthermore, while performing these comparisons, examination of the sensitivity of the results to modeling assumptions was also examined. These investigations serve to enable the creation of the LANL methodology for performing STRs. Given the wide variety of radiation test sources, scenarios, and detectors, LANL calculated comparisons of the following parameters: decay data, multiplicity, device (n,γ) leakages, and radiation transport through representative scenes and shielding. This investigation was performed to understand potential limitations utilizing specific codes for different aspects of the STR challenges.

07 ISOTOPE AND RADIATION SOURCES↗

Criticality Accident Alarm System Modeling with SCALE

Criticality accident alarm systems (CAAS) can be difficult to analyze since they consist of both criticality calculations and deep-penetration radiation transport calculations. Radiation transport codes are typically optimized for one of those two aspects but not both. A three-dimensional CAAS modeling capability within SCALE 6 has been created by linking the KENO-VI criticality code to the MAVRIC shielding sequence. KENO-VI has been optimized for criticality calculations and used for over 20 years. MAVRIC is a new sequence in SCALE 6 designed for radiation transport in deep-penetration problems. MAVRIC contains features such as automated variance reduction and mesh tally capabilities, which are quite useful in CAAS modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eikonal Corrections for Nucleus-Nucleus Reaction Cross Sections - Paper 90

The goal of this research is to modify a Fortran computer code, which uses an optical potential approximation to quantum mechanical multiple-scattering theory to compute total and reaction cross sections for nucleon-nucleus and nucleus-nucleus collisions for use in space radiation protection and shielding applications. These nuclear collision cross sections are utilized in space radiation transport codes that describe the passage of solar and galactic cosmic radiation fields through matter. In the code being modified by this work, an Eikonal approximation, in analogy with the complex index of refraction used to describe absorption in optics, is used to formulate the nuclear scattering amplitudes that describe the total and reaction cross sections in the formalism. Previous work found that the cross sections calculated with this model sometimes underestimated the experimental data. It has been noted that the Eikonal phase functions, which are used to calculate these cross sections and which contain all of the scattering information in the model, can be improved by incorporating higher order corrections In this work, a previously-developed first-order correction to the Eikonal phase function is coded in Fortran and incorporated into the optical model computer code that calculates reaction cross sections for nucleon-nucleus and nucleus-nucleus collisions at energies relevant to space radiation protection and shielding. The main thrust of this work is to test the use of this higher order correction by calculating reaction cross sections for a variety of nuclear collisions and comparing the results to experimental data. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TART2012 An Overview of A Coupled Neutron Photon 3-D, Combinatorial Geometry Time Dependent Monte Carlo Transport Code

This document is designed to provide an overview of TART2012, a coupled neutron photon, 3 Dimensional, combinatorial geometry, time dependent Monte Carlo radiation transport code. This code can run on any modern computer. It is a complete system to assist you with input preparation, running Monte Carlo calculations, and analysis of output results. TART2012 is also incredibly FAST; if you have used similar codes, you will be amazed at how fast this code is compared to other similar codes. Use of the entire system can save you a great deal of time and energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclide Depletion Capabilities in the Shift Monte Carlo Code

A new depletion capability has been developed in the Exnihilo radiation transport code suite. This capability enables massively parallel domain-decomposed coupling between the Shift continuous-energy Monte Carlo solver and the nuclide depletion solvers in ORIGEN to perform high-performance Monte Carlo depletion calculations. This paper describes this new depletion capability and discusses its various features, including a multi-level parallel decomposition, high-order transport-depletion coupling, and energy-integrated power renormalization. Several test problems are presented to validate the new capability against other Monte Carlo depletion codes, and the parallel performance of the new capability is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MatMCNP v. 4.0

https://www.osti.gov/doecMatMCNP is a code for generating material cards for the MCNP radiation transport code. The program allows for material specification as either atomic or weight percent (fractions). MatMCNP also permits the specification of enriched lithium, boron, and/or uranium. In addition to producing the material cards for MCNP, the code calculates the atomic (or number) density in atoms/barn-cm as well as the multiplier that should be used to convert neutron and gamma fluences into dose in the material specified.

Depriest, Kendall↗