Radiometer Design Analysis Based Upon Measurement Uncertainty

This paper introduces a method for predicting the performance of a radiometer design based on calculating the measurement uncertainty. The variety in radiometer designs and the demand for improved radiometric measurements justify the need for a more general and comprehensive method to assess system performance. Radiometric resolution, or sensitivity, is a figure of merit that has been commonly used to characterize the performance of a radiometer. However when evaluating the performance of a calibration design for a radiometer, the use of radiometric resolution has limited application. These limitations are overcome by considering instead the measurement uncertainty. A method for calculating measurement uncertainty for a generic radiometer design including its calibration algorithm is presented. The result is a generalized technique by which system calibration architectures and design parameters can be studied to optimize instrument performance for given requirements and constraints. Example applications demonstrate the utility of using measurement uncertainty as a figure of merit.

Racette, Paul E.↗

Development of a High-Stability Microstrip-based L-band Radiometer for Ocean Salinity Measurements

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This measurement requires the L-band radiometers to have calibration stabilities of less than or equal to 0.05 K over 2 days. This research has focused on determining the optimum radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that allows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and DC bias, system linearity, optimum noise diode injection calibration, and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability.

Pellerano, Fernando A.↗

Radiometer Calibrations: Saving Time by Automating the Gathering and Analysis Procedures

Mr. Abtahi custom-designs radiometers for Mr. Hook's research group. Inherently, when the radiometers report the temperature of arbitrary surfaces, the results are affected by errors in accuracy. This problem can be reduced if the errors can be accounted for in a polynomial. This is achieved by pointing the radiometer at a constant-temperature surface. We have been using a Hartford Scientific WaterBath. The measurements from the radiometer are collected at many different temperatures and compared to the measurements made by a Hartford Chubb thermometer with a four-decimal point resolution. The data is analyzed and fit to a fifth-order polynomial. This formula is then uploaded into the radiometer software, enabling accurate data gathering. Traditionally, Mr. Abtahi has done this by hand, spending several hours of his time setting the temperature, waiting for stabilization, taking measurements, and then repeating for other temperatures. My program, written in the Python language, has enabled the data gathering and analysis process to be handed off to a less-senior member of the team. Simply by entering several initial settings, the program will simultaneously control all three instruments and organize the data suitable for computer analyses, thus giving the desired fifth-order polynomial. This will save time, allow for a more complete calibration data set, and allow for base calibrations to be developed. The program is expandable to simultaneously take any type of measurement from up to nine distinct instruments.

Sadino, Jeffrey L.↗

An Overview of the Hurricane Imaging Radiometer (HIRAD)

Accurate observations of ocean surface vector winds (OSVW) with high spatial and temporal resolution are critically important to improve both our understanding and predictability of tropical cyclones. As the successful NASA QuikSCAT satellite continues to age beyond its planned life span, many members of the tropical cyclone research and operational community recognize the need to develop new observational technologies and strategies to meet the essential need for OSVW information. This concern has been expressed in both the "Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond" developed by the National Research Council Committee on Earth Science and Applications from Space and the "Interagency Strategic Research Plan for Tropical Cyclone The Way Ahead" developed by the Joint Action Group for Tropical Cyclone Research (JAG-TCR) sponsored by the Office of the Federal Coordinator for Meteorology. One innovative technology development which offers the potential for new, unique remotely sensed observations of tropical cyclone OSVW and precipitation is the Hurricane Imaging Radiometer (HIRAD). This new instrument is passive microwave synthetic thinned aperture radiometer under development at the NASA Marshall Space Flight Center that will operate at the C-Band frequencies of 4, 5, 6, and 7 GHz. These frequencies have been successfully demonstrated by the NOAA nadir-staring Stepped Frequency Microwave Radiometer (SFMR) as useful for monitoring tropical cyclone ocean surface wind speeds and rain rates from low altitude reconnaissance aircraft. The HIRAD design incorporates a unique antenna design as well as several technologies that have been successfully demonstrated by the University of Michigan Lightweight Rain Radiometer sponsored by NASA Earth Science Technology Office Instrument Incubator Program. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce imagery of ocean wind surface wind parameters and rain rate during the strong wind and heavy rain hurricane conditions that hamper the observational capabilities of higher frequency passive microwave radiometers or scatterometers. It will also produce imagery of sea surface temperature under cloudy and lightly precipitating skies eliminating the need for additional thermal infrared imagers. The strategic plan for HIRAD includes a roadmap for ocean surface wind speed and OSVW technology development using flight demonstrations on piloted aircraft, uninhabited aerial vehicle systems, and satellite platforms. The roadmap will include exit opportunities for technology transfer from research to operations based on satisfactory demonstrations. The first aircraft version of HIRAD will be singular polarization sensor designed to observe ocean surface wind speed and rainfall. The second aircraft version of HIRAD will be dual polarization sensor designed to observe OSVW as a prototype for a future satellite sensor.

Source record↗

Analog Radio-Frequency Interferences (RFI) Detectors for Microwave Radiometers

Microwave radiometers use radio spectrum dedicated to sensing the environment. As wireless communications and other active services proliferate, this allocated spectrum is nearly being crowded out. The potential result is corrupted satellite measurements of the weather, the climate, and the environment. We present an analog RFI detector for microwave radiometers intended to mitigate the above risks. The double detector (DD) for RFI detection includes a square-law diode detector with short integration time for measuring the total power out of the radiometer, followed by a second diode detector which acts as a higher-order statistical fourth-moment detector. See Figure 1 for block diagram of the system. This novel design which uses purely analog components at radio andlor intermediate frequencies allows the system to easily augment conventional radiometer architectures used in both airborne and space borne instruments. An equivalent high-speed digital design would add an impractical level of cost and complexity to radiometer designs using today's technology.

Knuble, Joseph J.↗

Potential of Future Hurricane Imaging Radiometer (HIRAD) Ocean Surface Wind Observations for Determining Tropical Storm Vortex Intensity and Structure

The Hurricane Imaging Radiometer (HIRAD) is an innovative technology development, which offers the potential of new and unique remotely sensed observations of both extreme oceanic wind events and strong precipitation from either UAS or satellite platforms. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is a proven aircraft remote sensing technique for observing tropical cyclone ocean surface wind speeds and rain rates, including those of major hurricane intensity. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer technology. This sensor will operate over 4-7 GHz (C-band frequencies) where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometers. HIRAD incorporates a unique, technologically advanced array antenna and several other technologies successfully demonstrated by the NASA's Instrument Incubator Program. A brassboard version of the instrument is complete and has been successfully tested in an anechoic chamber, and development of the aircraft instrument is well underway. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce wide-swath imagery of ocean vector winds and rain during hurricane conditions when existing microwave sensors (radiometers or scatterometers) are hindered. Preliminary studies show that HIRAD will have a significant positive impact on analyses as either a new aircraft or satellite sensor.

Atlas, Robert↗

Surface Wind Vector and Rain Rate Observation Capability of Future Hurricane Imaging Radiometer (HIRAD)

The Hurricane Imaging Radiometer (HIRAD) is the next-generation Stepped Frequency Microwave Radiometer (SFMR), and it will offer the capability of simultaneous wide-swath observations of both extreme ocean surface wind vector and strong precipitation from either aircraft (including UAS) or satellite platforms. HIRAD will be a compact, lightweight, low-power instrument with no moving parts that will produce valid wind observations under hurricane conditions when existing microwave sensors (radiometers or scatterometers) are hindered by precipitation. The SFMR i s a proven aircraft remote sensing system for simultaneously observing extreme ocean surface wind speeds and rain rates, including those of major hurricane intensity. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer technology. The first version of the instrument will be a single polarization system for wind speed and rain rate, with a dual-polarization system to follow for wind vector capability. This sensor will operate over 4-7 GHz (C-band frequencies) where the required tropical cyclone remote sensing physics has been validated by both SFMR and WindSat radiometers. HIRAD incorporates a unique, technologically advanced array antenna and several other technologies successfully demonstrated by NASA s Instrument Incubator Program. A brassboard (laboratory) version of the instrument has been completed and successfully tested in a test chamber. Development of the aircraft instrument is underway, with flight testing planned for the fall of 2009. Preliminary Observing System Simulation Experiments (OSSEs) show that HIRAD will have a significant positive impact on surface wind analyses as either a new aircraft or satellite sensor. New off-nadir data collected in 2008 by SFMR that affirms the ability of this measurement technique to obtain wind speed data at non-zero incidence angle will be presented, as well as data from the brassboard instrument chamber tests.

Miller, Timothy↗

The Correlation Radiometer - A New Application in MM-Wave Total Power Radiometry

We describe the design and performance of a 180 GHz correlation radiometer suitable for remote sensing. The radiometer provides continuous comparisons between a the observed signal and a reference load to provide stable radiometric baselines. The radiometer was assembled and tested using parts from the GeoSTAR-II instrument and is fully compatible with operation in a synthetic aperture radiometer or as a standalone technology for use in microwave sounding and imaging. This new radiometer was tested over several days easily demonstrating the required 6 hour stability requirement for observations of mean brightness temperature for a geostationary instrument.

Monolithic Microwave Integrated Circuit (MMIC)↗

IceCube: Demonstration of an 883 GHz Radiometer for Ice Cloud Remote Sensing

IceCube was a technology demonstration of an 883 GHz heterodyne radiometer on a 3U CubeSat for ice cloud characterization. The project was a collaboration between Goddard Space Flight Center, Virginia Diodes Inc., and Wallops Flight Facility. IceCube was launched to the International Space Station (ISS) in April 2017, and was deployed to the orbit in May 2017. The radiometer measured ice cloud emissions from an ISS orbit for over 15 months. IceCube generated the first 883 GHz cloud map over a large operation temperature range of (5 ºC—37 ºC). Cloud ice plays a major role in the cloud precipitation process and Earth’s energy budget. Ice clouds are used in global circulation models as tuning parameters to achieve model agreement with observation at the top of the atmosphere in the radiation budget and at the bottom for precipitation, however, due to a lack of accurate ice cloud measurements large uncertainties exist in these models. Submillimeter wave remote sensing is capable of addressing this issue by measuring cloud ice mass and microphysical properties in the middle-to-upper troposphere. This fills the sensitivity gap not covered by the visible/infrared and microwave sensors [1]. The goal of IceCube was to increase the TRL of a heterodyne 883 GHz radiometer (using commercial parts) from 5 to 7 by validating the performance in a relevant spaceflight environment. The design of the radiometer was driven by frequency of operation, bandwidth, calibration, available power, and thermal environment requirements. The design included a 15 mm aperture off-axis parabolic reflector with a Potter feed horn, an 883 GHz 2nd-harmonic mixer that is fed by a local oscillator chain with a 24.3 GHz dielectric resonator (MLA), followed by a 6 GHz bandwidth centered at 9 GHz intermediate frequency assembly (IFA), receiver interface card, and power distribution unit. The IFA included an internal noise diode calibration to separate the MLA performance from the rest of the system. For this the radiometer had four operational states: antenna, antenna + noise, reference, and reference + noise; each state’s duration was 10 ms. The total power dissipation of the instrument was 5.6 W. The spacecraft had spinning capabilities to provide a cold sky view for calibration. We present the instrument design, ground test results, challenges, and highlight some of the flight measurements.

N Ehsan↗

Development of a high stability microstrip-based L-band radiometer for ocean salinity measurements.

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This will require the L-band radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that al-lows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and bias, system linearity, optimum noise diode injection calibration and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This system is partially polarimetric providing V, H, -45 and +45 signals. Test results are compared to current and future ocean salinity radiometer requirements to show that the desire performance is possible.

Tanner, Alan B.↗

Sky-Scanning Sun-Tracking Airborne Radiometer (3STAR): Instrument Design, Flight Testing, and Tracking Performance

The Sky-Scanning, Sun-Tracking Airborne Radiometer (3STAR) adapts commercial radiometer technology developed for the ocean color research community to airborne measurement of spectrally resolved solar irradiance and sky radiance. These atmospheric observations are used to derive aerosol optical depth (AOD), supporting localized AOD inputs for atmospheric correction of satellite and airborne data over terrestrial and aquatic (including optically dark) targets. The ability to regionally “tune” atmospheric correction schemes with relevant spatial AOD supports constraining atmospheric correction of remote sensing reflectance. Very wide dynamic range has been achieved for multi-channel band-pass-filter-radiometers originally designed for deployment into the water column. By actively tracking and directly pointing to the Sun, the light attenuation by aerosol particles in the atmospheric column can be quantified. These measurements improve knowledge of atmospheric constituents and the atmospheric corrections required to improve remote sensing capabilities for interpreting reflectance measurements from the Earth surface. 3STAR incorporates a custom Sun-tracking/sky-scanning pointing head, a Sun-tracking camera, and a commercially available, cylindrical, 19-channel radiometer tube assembly. An accurate and responsive mount and tracking system has been developed and certified to NASA and Naval Air Systems Command (NAVAIR) airworthiness standards for deployment into the aircraft slipstream. Ground and flight testing indicate typical tracking errors of less than 0.1 degrees, well within the field of view of the radiometer as required to minimize measurement uncertainty from alignment error. Preliminary AOD measurements compare to within 0.013 with 15 measurements from an Aerosol Robotic Network (AERONET) Cimel instrument at 500 nm wavelength and low solar angle.

Atmosphere↗

Cloud and Precipitation Analyses using Merged Datasets from Two Airborne Microwave Radiometers Covering 10–183 GHz

Microwave radiometers provide valuable insight into the structure and characteristics of clouds and precipitation. In NASA’s airborne remote-sensing arsenal, the Advanced Microwave Precipitation Radiometer (AMPR) and the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) have been used extensively in field campaigns throughout the world. AMPR operates with four channels between 10.7 and 85.5 GHz, while CoSMIR operates with nine channels ranging from 50.3 to 183.31 GHz. Although these datasets provide key information when used separately, the combination of these radiometers covers virtually the full range of frequencies used by the Global Precipitation Measurement (GPM) Microwave Imager (GMI), enabling suborbital observations to compare with GPM spaceborne measurements. This presentation will detail the merger of AMPR and CoSMIR data during two NASA airborne field campaigns: the Integrated Precipitation and Hydrology Experiment (IPHEx) and the Olympic Mountains Experiment / Radar Definition Experiment (OLYMPEX/RADEX). Other field campaigns, such as the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS), may be included as well. Using the merged brightness temperature dataset, features of precipitating and non-precipitating clouds containing liquid and/or ice hydrometeors will be discussed from selected flight segments. Geophysical retrievals derived from these brightness temperatures using a one-dimensional variational (1DVAR) technique and/or multi-linear regression equations will also be employed in these analyses. Observed transitions between precipitating and non-precipitating systems will be explored in greater detail. Dropsonde data will be used to provide environmental contexts throughout each flight, and additional observations (e.g., from airborne and/or land-based radar) will be incorporated to supplement the radiometer-based results. The broader implications of these results and pathways for future work will also be discussed.

Corey G. Amiot↗

On the Long-Term Stability of Microwave Radiometers Using Noise Diodes for Calibration

Results are presented from the long-term monitoring and calibration of the National Aeronautics and Space Administration Jason Microwave Radiometer (JMR) on the Jason-1 ocean altimetry satellite and the ground-based Advanced Water Vapor Radiometers (AWVRs) developed for the Cassini Gravity Wave Experiment. Both radiometers retrieve the wet tropospheric path delay (PD) of the atmosphere and use internal noise diodes (NDs) for gain calibration. The JMR is the first radiometer to be flown in space that uses NDs for calibration. External calibration techniques are used to derive a time series of ND brightness for both instruments that is greater than four years. For the JMR, an optimal estimator is used to find the set of calibration coefficients that minimize the root-mean-square difference between the JMR brightness temperatures and the on-Earth hot and cold references. For the AWVR, continuous tip curves are used to derive the ND brightness. For the JMR and AWVR, both of which contain three redundant NDs per channel, it was observed that some NDs were very stable, whereas others experienced jumps and drifts in their effective brightness. Over the four-year time period, the ND stability ranged from 0.2% to 3% among the diodes for both instruments. The presented recalibration methodology demonstrates that long-term calibration stability can be achieved with frequent recalibration of the diodes using external calibration techniques. The JMR PD drift compared to ground truth over the four years since the launch was reduced from 3.9 to - 0.01 mm/year with the recalibrated ND time series. The JMR brightness temperature calibration stability is estimated to be 0.25 K over ten days.

noise diode (ND)↗

High Frequency PIN-Diode Switches for Radiometer Applications

Internally calibrated radiometers are needed for ocean topography and other missions. Typically internal calibration is achieved with Dicke switching as one of the techniques. We have developed high frequency single-pole double-throw (SPDT) switches in the form of monolithic microwave integrated circuits (MMIC) that can be easily integrated into Dicke switched radiometers that utilize microstrip technology. In particular, the switches we developed can be used for a radiometer such as the one proposed for the Surface Water and Ocean Topography (SWOT) Satellite Mission whose three channels at 92, 130, and 166 GHz would allow for wet-tropospheric path delay correction near coastal zones and over land. This feat is not possible with the current Jason-class radiometers due to their lower frequency signal measurement and thus lower resolution. The MMIC chips were fabricated at NGST using their InP PIN diode process and measured at JPL using high frequency test equipment. Measurement and simulation results will be presented.

PIN-diode↗

Soil Moisture Active Passive (SMAP) Microwave Radiometer Radio-Frequency Interference (RFI) Mitigation: Initial On-Orbit Results

The Soil Moisture Active Passive (SMAP) mission, launched in January 2015, provides global measurements of soil moisture using a microwave radiometer. SMAPs radiometer passband lies within the passive frequency allocation. However, both unauthorized in-band transmitters as well as out-of-band emissions from transmitters operating at frequencies adjacent to this allocated spectrum have been documented as sources of radio frequency interference (RFI) to the L-band radiometers on SMOS and Aquarius. The spectral environment consists of high RFI levels as well as significant occurrences of low level RFI equivalent to 0.1 to 10 K. The SMAP ground processor reports the antenna temperature both before and after RFI mitigation is applied. The difference between these quantities represents the detected RFI level. The presentation will review the SMAP RFI detection and mitigation procedure and discuss early on-orbit RFI measurements from the SMAP radiometer. Assessments of global RFI properties and source types will be provided, as well as the implications of these results for SMAP soil moisture measurements.

radiometers↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

The Soil Moisture Active/Passive (SMAP) microwave radiometer is a fully polarimetric L-band radiometer flown on theSMAP satellite in a 6 AM/6 PM sun-synchronous orbit at 685 km altitude. After the SMAP L1B_TB data product version 3 was released in 2016, the radiometer has been undergoing further calibration and validation with the goal of reducing both the bias in the cold-sky measurements and calibration drift in the global ocean measurements experienced during eclipse seasons in data product version 3. The post-launch calibration algorithm has been upgraded by using new estimates of the reflector emissivity as well as using multiple scenes to calibrate the radiometer internal reference sources and antenna gain simultaneously. In addition, a correction offset is applied to the ocean roughness model for horizontal polarization based on nadir observations. Test and validation results show that the goal is achieved (e.g., biases are removed and the calibration stability achieved for data release version 4 is 0.1 K(rms) over both the global ocean and CS).

Calibratio↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

Radiometer-deployment subsystem

A radiometer-deployment subsystem for the Nimbus E spacecraft was designed, developed, and qualified for space use. The dimensions of the radiometer are 0.9 meter square by 0.1 meter, and its weighs 32 kilograms. Rigidly secured to the spacecraft during launch, the radiometer is deployed when the spacecraft reaches orbit. Deployment is achieved without permitting any portion of the radiometer to intersect the field of view of the infrared horizon scanner. This accomplishment necessitated a nonlinear deployment profile, which was accomplished by using a four-bar linkage composed of arms, cams, pivots, and steel tapes.

Speight, K. M.↗