Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion and a mobile body portion. The mobile body portion is configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the microwave radiometer therein such that the microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion. In an embodiment, the mobile body portion includes a plurality of body section, each body section being configured for supporting a microwave radiometer therein. In another embodiment, each one of the plurality of body sections is configured to be interchangeably coupled with each other.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion, the fixed body portion being configured to attach to a mobile platform, and a mobile body portion, the mobile body portion being configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the at least one microwave radiometer therein such that the at least one microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the at least one radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion such that the at least one microwave radiometer provides a vertical scanning below and above the mobile platform.

Klein, Marian↗

NREL Pyrheliometer Comparisons: September 23-October 4, 2019 (NPC-2019)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG.

14 SOLAR ENERGY↗

Downwelling Shortwave and Longwave Irradiance from CC-RIDER on Mount Soledad

The Clouds and Climate - Remote Integrated Deployment of Radiometers (CC-RIDER) is a suite of five Eppley Laboratory (Inc.) instruments that was deployed during EPCAPE at the secondary Mount Soledad site in La Jolla, CA. A primary and backup Precision Spectral Pyranometer (PSP Primary, PSP Backup) measured broadband downwelling shortwave irradiance in the spectral interval 280-2800 nm. A third Precision Spectral Pyranometer (PSP NIR) was fitted with a near-infrared long pass filter and measured downwelling shortwave irradiance in the spectral interval 780-2800 nm. A Total Ultraviolet Radiometer (TUVR) measured broadband downwelling broadband ultraviolet irradiance in the spectral interval 295-385 nm. A Precision Infrared Radiometer (PIR) Pyrgeometer measured downwelling broadband longwave irradiance in the spectral interval 3.5 - 50 microns. Data collection began on 18 April 2023 at 21:31 UTC and ended on 20 February 2024 at 22:34 UTC. Data were recorded by a Campbell Scientific (Inc.) CR1000X datalogger in one-minute intervals, for a total of 443584 data records. The datalogger was solar powered enabling data collection to proceed without interruption from start to finish.

Clouds and Climate – Remote Integrated DEployement↗

Chelating Rare-Earth Metals (Ln 3+ ) and 225 Ac 3+ with the Dual-Size-Selective Macrocyclic Ligand Py 2 -Macrodipa

Radioisotopes of metallic elements, or radiometals, are widely employed in both therapeutic and diagnostic nuclear medicine. For this application, chelators that efficiently bind the radiometal of interest and form a stable metal–ligand complex with it are required. Toward the development of new chelators for nuclear medicine, we recently reported a novel class of 18-membered macrocyclic chelators that is characterized by their ability to form stable complexes with both large and small rare-earth metals (Ln 3+ ), a property referred to as dual size selectivity. A specific chelator in this class called py-macrodipa, which contains one pyridyl group within its macrocyclic core, was established as a promising candidate for 135 La 3+ , 213 Bi 3+ , and 44 Sc 3+ chelation. Building upon this prior work, here we report the synthesis and characterization of a new chelator called py 2 -macrodipa with two pyridyl units fused into the macrocyclic backbone. Its coordination chemistry with the Ln 3+ series was investigated by NMR spectroscopy, X-ray crystallography, density functional theory (DFT) calculations, analytical titrations, and transchelation assays. These studies reveal that py 2 -macrodipa retains the expected dual size selectivity and possesses an enhanced thermodynamic affinity for all Ln 3+ compared to py-macrodipa. By contrast, the kinetic stability of Ln 3+ complexes with py 2 -macrodipa is only improved for the light, large Ln 3+ ions. Based upon these observations, we further assessed the suitability of py 2 -macrodipa for use with 225 Ac 3+ , a large radiometal with valuable properties for targeted α therapy. Radiolabeling and stability studies revealed py 2 -macrodipa to efficiently incorporate 225 Ac 3+ and to form a complex that is inert in human serum over 3 weeks. Although py 2 -macrodipa does not surpass the state-of-the-art chelator macropa for 225 Ac 3+ chelation, it does provide another effective 225 Ac 3+ chelator. Furthermore, these studies shed light on the fundamental coordination chemistry of the Ln 3+ series and may inspire future chelator design efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capturing an elusive but critical element: Natural protein enables actinium chemistry

Actinium-based therapies could revolutionize cancer medicine but remain tantalizing due to the difficulties in studying and limited knowledge of Ac chemistry. Current efforts focus on small synthetic chelators, limiting radioisotope complexation and purification efficiencies. Here, we demonstrate a straightforward strategy to purify medically relevant radiometals, actinium(III) and yttrium(III), and probe their chemistry, using the recently discovered protein, lanmodulin. The stoichiometry, solution behavior, and formation constant of the 228 Ac 3+ -lanmodulin complex and its 90 Y 3+ / nat Y 3+ / nat La 3+ analogs were experimentally determined, representing the first actinium-protein and strongest actinide(III)-protein complex (sub-picomolar Kd) to be characterized. Lanmodulin’s unparalleled properties enable the facile purification recovery of radiometals, even in the presence of >10 +10 equivalents of competing ions and at ultratrace levels: down to 2 femtograms 90 Y 3+ and 40 attograms 228 Ac 3+ . The lanmodulin-based approach charts a new course to study elusive isotopes and develop versatile chelating platforms for medical radiometals, both for high-value separations and potential in vivo applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Shortwave Array Spectroradiometer-Hemispheric (SAS-He): design and evaluation

A novel ground-based radiometer, referred to as the Shortwave Array Spectroradiometer-Hemispheric (SAS-He), is introduced. This radiometer uses the shadow-band technique to report total irradiance and its direct and diffuse components frequently (every 30 s) with continuous spectral coverage (350–1700 nm) and moderate spectral (~2.5 nm ultraviolet–visible and ~6 nm shortwave-infrared) resolution. The SAS-He's performance is evaluated using integrated datasets collected over coastal regions during three field campaigns supported by the US Department of Energy's Atmospheric Radiation Measurement (ARM) program, namely the (1) Two-Column Aerosol Project (TCAP; Cape Cod, Massachusetts), (2) Tracking Aerosol Convection Interactions Experiment (TRACER; in and around Houston, Texas), and (3) Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE; La Jolla, California). We compare (i) aerosol optical depth (AOD) and total optical depth (TOD) derived from the direct irradiance, as well as (ii) the diffuse irradiance and direct-to-diffuse ratio (DDR) calculated from two components of the total irradiance. As part of the evaluation, both AOD and TOD derived from the SAS-He direct irradiance are compared to those provided by a collocated Cimel sunphotometer (CSPHOT) at five (380, 440, 500, 675, 870 nm) and two (1020, 1640 nm) wavelengths, respectively. Additionally, the SAS-He diffuse irradiance and DDR are contrasted with their counterparts offered by a collocated multifilter rotating shadowband radiometer (MFRSR) at six (415, 500, 615, 675, 870, 1625 nm) wavelengths. Overall, reasonable agreement is demonstrated between the compared products despite the challenging observational conditions associated with varying aerosol loadings and diverse types of aerosols and clouds. For example, the AOD- and TOD-related values of root mean square error remain within 0.021 at 380, 440, 500, 675, 870, 1020, and 1640 nm wavelengths during the three field campaigns.

47 OTHER INSTRUMENTATION↗

Absolute Cavity Pyrgeometer (ACP)

ACP Measures atmospheric longwave irradiance with traceability to the International System of Units (SI). To date the Interim world reference World Infrared Standard Group (WISG) is traceable to blackbody (not sky/atmosphere), and InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. The ACP is self calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗

Absolute Cavity Pyrgeometer (ACP)

Measure atmospheric longwave irradiance. ABSOLUTE measurement traceable to International System of Units (SI). To date, Interim world reference traceable to blackbody (not sky/atmosphere), World Infrared Standard Group (WISG). InfraRed Integrating Sphere (IRIS) Developed by the World Radiation Center (PMOD) is traceable to blackbody irradiance. ACP is self-calibrated radiometer using heat substitution like Absolute Cavity Radiometer (ACR) that is self-calibrated radiometer using electrical substitution to measure solar irradiance. ACP is a contribution to develop the world reference with traceability to SI, using the outdoor irradiance as the source, instead of blackbody.

ACP↗

Surface Energy Balance System (SEBS) Instrument Handbook

A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

54 ENVIRONMENTAL SCIENCES↗

Measured Long-Term Solar Irradiance for Climate Studies

Solar radiation is primarily measured using high-quality radiometers (e.g., pyranometers and pyrheliometers). These instruments need to be calibrated regularly (every two years at a minimum). They are also susceptible to various sources of uncertainties. Therefore, rigorous data quality assessment is required to obtain high-confidence data from these radiometers. This is especially true when the data is used to understand climatic trends and/or extreme weather events. In this study, we attempted to create a continuous and reliable dataset by correcting the underlying data which we believe contains bias due to reference pyranometers swap procedures. These biases can be significant which can be up to two percentage points thereby influencing the interpretation of climate changes and/or extreme events. This study elaborates on the biases and methods to correct those biases.

data integrity↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗

NREL Pyrheliometer Comparisons: November 4 & 29, 2021 (NPC-2021)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, for improving our understanding of Earth’s energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements.

14 SOLAR ENERGY↗

Factors Governing Cloud Growth and Entrainment Rates in Shallow Cumulus and Cumulus Congestus During GoAmazon2014/5

Shallow cumulus and cumulus congestus clouds play an important role in the large-scale tropical circulation by mixing heat and moisture vertically and preconditioning the environment for deeper convection. Different representations of these shallow clouds account for much of the spread in General Circulation Model (GCMs) climate sensitivity, potentially because of how entrainment is represented in GCM parameterizations. This study uses observations from the Department of Energy's Atmospheric Radiation Measurement (ARM) mobile facility deployed at Manacapuru, Brazil, during the Green Ocean Amazon (GoAmazon2014/5) Campaign. Environmental thermodynamic profiles and observations of cloud top height (CTH) are used to constrain an entraining plume model to estimate bulk entrainment rates (ERs). Estimates of CTH are obtained from a combination of vertically pointing W-band ARM cloud radar and 1,290 MHz Radar Wind Profiler observations. A combination of radiosonde, microwave radiometer profiler, and microwave radiometer observations provides new best estimates of the environmental thermodynamic state. We quantify uncertainty in ERs considering uncertainties in estimated CTH, environmental thermodynamic properties, and assumed initial parcel characteristics. We find ERs ranging from 0.16 to 2.8 km -1 with an average of 0.58 ± 0.10 km -1 over a selected population of 469 shallow cumulus and cumulus congestus clouds. Using the retrieved estimates of ER, we evaluate several entrainment closures that are currently used in atmospheric models or have been proposed based on theory or large eddy simulation. Finally, entrainment rates in cumulus clouds are weakly correlated with low-level buoyancy, cloud depth, and cloud size.

54 ENVIRONMENTAL SCIENCES↗

Broadband radiometric measurements from GPS satellites reveal summertime Arctic Ocean Albedo decreases more rapidly than sea ice recedes

Abstract New measurements from the Arctic ± 40 days around the summer solstice show reflected sunlight from north of 80°N decreases 20–35%. Arctic sea ice coverage decreases 7–9% over this same time period (as reported by the NSIDC) implying Arctic sea ice albedo decreases in addition to the sea ice receding. Similar Antarctic measurements provide a baseline to which Arctic measurements are compared. The Antarctic reflected sunlight south of 80°S is up to 30% larger than the Arctic reflectance and is symmetric around the solstice implying constant Antarctic reflectivity. Arctic reflected sunlight 20 days after solstice is > 100W/m 2 less than Antarctic reflected sunlight. For perspective, this is enough heat to melt > 1 mm/hour of ice. This finding should be compared with climate models and in reanalysis data sets to further quantify sea ice albedo’s role in Arctic Amplification. The measurements were made with previously unpublished pixelated radiometers on Global Positioning System satellites from 2014 to 2019. The GPS orbits give each radiometer instantaneous and continuous views of 37% of the Earth, two daily full views of the Arctic and Antarctic. Furthermore, the GPS constellation gives full-time full-Earth coverage that may provide data that complements existing limited field of view instruments that provide a less synoptic Earth view.

54 ENVIRONMENTAL SCIENCES↗

Siderocalin fusion proteins enable a new 86 Y/ 90 Y theranostic approach

The mammalian protein siderocalin binds bacterial siderophores and their iron complexes through cation-π and electrostatic interactions, but also displays high affinity for hydroxypyridinone complexes of trivalent lanthanides and actinides. In order to circumvent synthetic challenges, the use of siderocalin-antibody fusion proteins is explored herein as an alternative targeting approach for precision delivery of trivalent radiometals. We demonstrate the viability of this approach in vivo, using the theranostic pair 90 Y (β − , t 1/2 = 64 h)/ 86 Y (β + , t 1/2 = 14.7 h) in a SKOV-3 xenograft mouse model. Ligand radiolabeling with octadentate hydroxypyridinonate 3,4,3-LI(1,2-HOPO) and subsequent protein binding were achieved at room temperature. The results reported here suggest that the rapid non-covalent binding interaction between siderocalin fusion proteins and the negatively charged Y(III)-3,4,3-LI(1,2-HOPO) complexes could enable purification-free, cold-kit labeling strategies for the application of therapeutically relevant radiometals in the clinic.

Cosby, Alexia G.↗

New, improved analysis of correlation ECE data to accurately determine turbulent electron temperature spectra and magnitudes (invited)

Turbulent electron temperature fluctuation measurement using a correlation electron cyclotron emission (CECE) radiometer has become an important diagnostic for studying energy transport in fusion plasmas, and its use is widespread in tokamaks (DIII-D, ASDEX Upgrade, Alcator C-Mod, Tore Supra, EAST, TCV, HL-2A, etc.). The CECE diagnostic typically performs correlation analysis between two closely spaced (within the turbulent correlation length) ECE channels that are dominated by uncorrelated thermal noise emission. This allows electron temperature fluctuations embedded in the thermal noise to be revealed and fluctuation level and spectra determined. We have demonstrated a new, improved CECE coherency-based analysis for calculating the temperature fluctuation frequency spectrum and level, which has been verified both numerically through the simulation of synthetic ECE radiometer data and through analysis of experimental data from the CECE system on DIII-D. The new formulation places coherency-based analysis on a firm foundational footing and corrects some currently published methodologies. This new method accurately accounts for bias error in the coherence function and correctly calculates noise levels for a fixed data record length. It provides excellent accuracy in determining temperature fluctuation level (e.g., <10% error) even for a small realization number in the ensemble average. The method also has a smaller uncertainty (i.e., error bar) in the power spectrum when compared to the more standard cross-power method when evaluated at low coherency. Direct calculation of system noise level using correlation between randomized intermediate frequency signals is recommended.

Wang, G. (ORCID:0000000225739827)↗