Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ramp control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-Temperature Multi-Process Sensor Development and Demonstration at Coalfired Power Plants

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Full-scale Demonstration of Multi-process Sensor at a Cycling PC-fired Boiler

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shedding in Large Offices

This documentation focuses on a single End-Use Savings Shape measure - thermostat control for load shedding. The thermostat control for load shedding measure applies heating and cooling temperature setpoint offsets for reducing the heating and cooling load during peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the peak window, and then adjusts the thermostat cooling and/or heating setpoints by an offset value from original schedules during the peak window to reduce the HVAC or whole building daily peak load. The measure is flexible and allows users to adjust the heating and cooling offset values respectively, but for this study, the adjustment for heating and cooling setpoints are set to -2 degrees Celsius and +2 degrees Celsius by default. The measure provides options of adding rebound control period (default 2 hours) after peak windows for the setpoints to be ramped back to default values, to prevent the system from generating higher peak demand with step changes of setpoints in post-peak periods . This measure is applicable t o large offices equipped with electric HVAC system (either electric cooling only or both electric heating and cooling), which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shedding measure demonstrates 2-5% daily peak demand reduction and 0.068% total site energy savings (3 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters

Smart inverters (SIs) have demonstrated their potential to provide grid services for both transmission and distribution systems. One of these grid services, distribution network voltage regulation by SIs, has the potential to improve network voltage regulation through controlling the reactive and active power output of the SIs. Voltage regulation by SIs will be distributed and might be better suited to controlling local conditions to complement traditional voltage-regulating assets, e.g., tap-changing transformers, capacitor banks, and line voltage regulators. There is a gap in the literature on comparing the SI response characteristics when the SIs are controlled by a local controller or external control signals. This paper presents an experimental study to characterize SI reactive power regulation responses to two different control methods: autonomous control and remote dispatch. We found that SI reactive power regulation responses exhibit important differences between these methods in terms of delays and ramp rate. Finally, power-hardware-in-the-loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL test results show that the SI response characteristics for autonomous control and remote dispatch need to be considered when planning for distribution network voltage regulation using SIs.

autonomous control↗

Pulsed High Temperature Superconducting Central Solenoid Model Coil for Plasma Current Drive and Control in High-Field Compact Commercial Fusion Power Plants (CRADA Final Report)

This ARPA-E BETHE project was aimed to design, build and test a fast-ramping HighTemperature Superconducting (HTS) Central Solenoid Model Coil (CSMC) that significantly derisks a full-size HTS Central Solenoid (CS) capable of driving and controlling the plasma current in a compact, high-field, low-cost tokamak power plant. The LBNL objectives and milestones for this project were divided into two distinct tracts: Diagnostics and Quench Simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing Customer Experience and Business Models around Price-to-Device Communication and Smart Control Pathways in CalFlexHub

California is facing three major challenges in electrical grid operation: renewable overgeneration, steep evening ramping, and growing peak demand. The state has identified dynamic retail price response as a key strategy evidenced by CPUC’s Dynamic Rates proceeding and CEC’s Load Management Standards. Furthermore, the CEC launched a $16M “California Load Flexibility Research and Deployment Hub (CalFlexHub)” administered by Berkeley Lab to accelerate price-response flexible load technologies in buildings and EV charging. There are more than 16 laboratory and field demonstration projects in CalFlexHub, each demonstrating innovative automated price-response technologies. CalFlexHub tests various pathways through which hourly price signals and triggered control commands are communicated to load-flexible devices such as smart thermostats, heat pumps, water heaters, and EVs. We identified seven unique communication and control pathways, which involve combinations of third-party cloud, device OEM’s cloud, building central gateway, and local controller in between the price server and the load-flexible devices. It is important for utilities and policy makers to understand the long-term implications of each pathway in designing future programs and creating related policies and mandates for market transformation. We propose an evaluation framework including the following aspects: ● Functionality: connectivity and uptime, resilience, and optimization; ● Customer experience: simplicity in setup, troubleshooting support, continuity, customer choice, first cost, and ongoing cost; ● Business model and scalability: advance interoperability, holistic solution, bridge unique gap, customer base, and value streams and pricing structures. In this paper, we identify emerging business models associated with each communication pathway and discuss their positive features and challenges from the above aspects.

Liu, Jingjing↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part A. Analysis and model validation on ASDEX Upgrade

We discuss how the combination of experimental observations and rapid modeling has enabled to improve understanding of the tokamak ramp-down phase in ASDEX Upgrade. A series of dedicated experiments has been performed, to disentangle the effect of individual actuators like plasma current, auxiliary heating and plasma shaping. Optimized discharge termination strategies with increased margin with respect to radiative and vertical stability limits are proposed and tested in experiment. Radiative collapse of the edge $T$ $e$ profile after the HL back-transition is avoided by initially maintaining auxiliary heating during L-mode, showing beneficial effects even after the auxiliary heating is turned off. The capability of the RAPTOR code to model the time evolution of the internal inductance $\ell$ $i3$ has been validated, including the effect of a change in the $I$ $p$ ramp-down rate and the HL transition timing. The reduction of $\ell$ $i3$ caused by rapid compression of the plasma cross-section has been quantitatively recovered in simulations. Successful modeling of the $\ell$ $i3$ time evolution is essential to optimize ramp-down scenarios for future fusion reactors, for which vertical stability and power balance control will be more challenging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving power grid transient stability and transfer capability using HVDC emergency power controls

In the future, with high levels of renewable energy sources penetration, the transmission corridors will have to be flexible to operate under faster transients and variable power flows. Fast power ramping and overloading capabilities of HVDC system can be utilized to ensure transient stability of the interconnected power grid. In this paper, HVDC auxiliary controllers have been studied that can provide the power grid with additional synchronizing torques through fast DC power changes in response to arising system conditions. The effectiveness of the auxiliary controllers in improving transient stability is demonstrated by performing dynamic simulations on the detailed model of the Western Interconnection system (WECC).

Sundaresh, Lakshmi↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part B. safe termination of DEMO plasmas

An optimized plasma current ramp-down strategy is critical for safe and fast termination of plasma discharges in a tokamak demonstration fusion reactor (DEMO), both in planned and emergency scenarios, avoiding plasma disruptions and excessive heat loads to the first wall. Plasma stability limits and machine-specific technical requirements constrain the stable envelope through which the plasma must be navigated. Large amounts of auxiliary heating are required throughout the ramp-down phase, to avoid a radiative collapse in the presence of intrinsic tungsten and seeded xenon impurities, as quantitatively estimated in this work. As the plasma current is reduced, the current density becomes increasingly peaked, reflected by a growing value of the internal inductance $\ell$ $i3$ , resulting in reduced controllability of the vertical position of the plasma. The feasibility of different plasma current ramp-down rates is tested by applying an automated optimization framework embedding the RAPTOR core transport solver. Optimal time traces for plasma current $I$ $p$ $(t)$ and plasma elongation $κ(t)$ are proposed, to satisfy an $I$ $p$ -dependent upper limit on the plasma internal inductance, as obtained from vertical stability studies using the CREATE-NL code, as well as a constraint on the time evolution of $q$ 95 , to avoid an ideal MHD mode. A negative current density near the plasma edge is observed in our simulations, even for the most conservative $I$ $p$ ramp-down rate, indicating significant transient dynamics due to a large resistive time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

Demonstration of a tandem lens for producing shaped laser-ionized plasmas for plasma wakefield acceleration

We demonstrate a tandem lens optical setup, comprising two diffractive optics, that focuses a high-power ultrafast laser with a shaped on-axis intensity profile, producing a meter-long Bessel focus. The intended use of the optical setup is to produce a laser-ionized plasma source for plasma wakefield acceleration. By controlling the on-axis intensity, the density profile of the plasma ramps at the entrance and exit of the plasma can be tailored to optimize the matching of the electron beam into the plasma. In addition to demonstrating the optical system, we describe the algorithm used to calculate the lens phases and present detailed calculations of the lenses’ expected performance.

Ariniello, Robert [SLAC National Accelerator Labor↗

Design and optimization of flexible decoupled high-temperature gas-cooled reactor plants with thermal energy storage

Advanced nuclear power plants are well-positioned for future zero-carbon grids, however, the need for flexible power generation will be required over the traditional emphasis on baseload generation for meeting historical demands. To achieve such flexibility, this work examines viable configurations for coupling nuclear energy production with thermal energy storage. Previous designs on nuclear-thermal energy storage configurations for advanced reactor designs, which utilized reactor steam as the heat source for charging the thermal energy storage, are restricted by the heat diversion ratio and efficiency losses, thus their impacts can be limited. In this context, this study proposes configurations for fully decoupling the nuclear reactor from the power cycle and positioning the storage as an intermediate loop, thereby achieving an unconstrained heat diversion ratio and improved efficiency. Compared with a standard high-temperature gas-cooled reactor’s power cycle, steady-state thermodynamic modeling and dispatch optimizations quantify the benefits of a steam reheat cycle within the fully decoupled thermal energy system to separate the plant cycle from the high-pressure primary side. These benefits are further detailed, compatible with required high-temperature and high-pressure conditions, through (1) open-source dynamic transient models that examine the impact of off-design operation on the systems, (2) the investigation of components design and costing and finally (3) sizing and dispatch optimization. The fully-decoupled design achieves a cycle efficiency of 43.1%, an enhancement over the vendor’s standard efficiency of 42.2% (Xe-100 design). Here, the proposed design offers strengthened physical barriers from the nuclear island as well as superior operational flexibility and power boosting. Dispatch optimization and market analysis reveal that thermal energy storage size is highly dependent on the peak patterns of electricity prices and the minimum generation level constraint imposed on the balance of plant. Evaluation of off-design operation demonstrates that the full decoupling design with the suggested fail-safe control mechanisms ensures a minimal impact on reactor parameters, even during rapid power ramping.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Effect of Radical Initiators on Polypropylene Thermal Deconstruction

A new route for polypropylene (PP) deconstruction through radical pathways based on thermodynamic and kinetic considerations has been investigated. Radical polypropylene (PP) deconstruction, activated through small quantities of initiators, can enable the deconstruction of waste POs into unsaturated products. We found that stirring was detrimental to the β-scission extent because it accelerates radical termination reactions through mixing. The best results were achieved by using a semibatch process that included mechanical mixing during the temperature ramp, static heating of the polymer/initiator mixture at the final temperature, and volatile product removal with N 2 . Dicumyl peroxide and alkylated dicumene initiators produced similar liquid and solid products after a 30 min thermal treatment. Terminal alkenes were formed in the liquid products of reactions at 375 and 400 °C, with about 5% of the protons in the liquid product ascribed to terminal alkenes. Yields of liquid products increased with temperature, reaching 60% w/w at 400 °C; at the same time, yields of solid products decreased with temperature to 16% w/w at 400 °C. Although radical initiators decrease PP molecular weight during the temperature ramp, at 400 °C, initiators only marginally increased the liquid product fraction compared to control experiments. Finally, the terminal double bonds in the liquid product mixture (C8–C36) provide multiple pathways for upgrading to surfactants, plasticizers, lube oils, and other valuable products.

liquids↗

Transient behavior of oxide fuels with controlled microstructure and Cr2O3 additive

Abstract Microstructure and Cr 2 O 3 doping profoundly impact the thermal-mechanical properties and fracture of oxides fuels. It is a challenge to study the transient behavior of nuclear fuels under loss-of-coolant-event (LOCA). In this study, the crack behavior of UO 2 pellets with controlled grain structure and Cr 2 O 3 doping was tested with rapid power ramping (300−900 °C per min) mimicking a prototypical LOCA heating profile. Dense micron-sized UO 2 pellets display well-maintained integrity without cracking with the ramping up to 1500 °C at a heating rate of 8 °C per second. Fracture occurs in both pure and Cr 2 O 3 -doped dense nano-sized UO 2 pellets. The Cr 2 O 3 doped oxide fuel pellet with a larger grain size (~ 22.2 μm) displays the best performance under LOCA testing due to its highest thermal conductivity under high temperature. FEA calculations suggest a temperature gradient across the fuel pellet during transient testing, resulting in residual stress and cracking, which can be correlated with their thermal-mechanical properties.

Zhao, Dong (ORCID:0000000191377257)↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗