Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rare & new isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Direct Measurement of the Be 7 L / K Capture Ratio in Ta-Based Superconducting Tunnel Junctions

We report a high-statistics measurement of the L / K orbital electron capture ratio in 7 Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction radiation detector that was used to identify the signals from different decay channels. The measured L/K capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. Furthermore, this is the first experiment that uses superconducting tunnel junctions for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

6 ≤ A ≤ 19↗

Laser Spectroscopy of Exotic Atoms and Molecules Containing Octupole-Deformed Nuclei

This project investigated the nuclear, atomic, and molecular structure of exotic atoms and molecules containing actinide isotopes. These short-lived radioactive systems are challenging to produce and study in the laboratory, yet they offer unique opportunities for fundamental science. These nuclei are predicted to exhibit pear-shaped (octupole) deformation, a rare collective nuclear behavior that dramatically enhances their sensitivity to fundamental physics phenomena such as time-reversal- and parity-violating effects. Such enhancements make them ideal probes for exploring open questions in our understanding of the universe such as the origin of the matter–antimatter asymmetry of the universe. To realize these measurements, the project led the development of a new laser spectroscopy experiment at MIT, and later commissioned at the Facility for Rare Isotope Beams (FRIB) at Michigan State University: the Resonance Ionization Spectroscopy Experiment (RISE). RISE combines the spectroscopic precision of collinear laser spectroscopy with the sensitivity of particle-detection techniques, enabling measurements of rare isotopes produced at rates as low as a few ions per second. The beamline was designed, built, and installed, and was successfully commissioned at FRIB during the grant period. RISE is now a permanent capability of the FRIB facility, and has produced several results on the study of rare atoms and molecules for nuclear structure and fundamental symmetries. In parallel with the FRIB program, the project contributed to the first precision laser-spectroscopy measurements of short-lived radioactive molecules. Working with international collaborators at CERN's ISOLDE facility, the team conducted pioneering experiments on radium monofluoride (RaF) and actinium monofluoride (AcF). The results from this work have been published in major journals of science, including Nature, Science, Nature Physics, Nature Communications, and Physical Review Letters. These findings have guided future experiments on the laser cooling of radioactive molecules, opening a new platform for precision tests of fundamental symmetries.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantification and purification of isotopic contamination at the ReAccelerator of the Facility for Rare Isotope Beams

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

Instruments & Instrumentation↗

Discovery of Nuclides Project

The Discovery of Nuclides project compiles detailed discovery information for all naturally occurring and artificially produced nuclides. The short abstracts for each nuclide include the authors, institution, country, year, method of discovery, and reference. The database contains over 3300 nuclides and is continuously updated as new nuclides are discovered. The work is performed at the Facility for Rare Isotope Beams (FRIB) and is supported by the U.S. Department of Energy, Office of Nuclear Physics under Grant No. DE-SC0016948 and Michigan State University. The FRIB Nuclear Data group is responsible for coordinating and updating the database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Application of Mass Measurements with the Rare-RI Ring Reveals the Solar r -Process Abundance Trend at A = 122 and A = 123

The Rare-RI Ring (R3) is a recently commissioned cyclotronlike storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF— 127 Sn, 126 In, 125 Cd, 124 Ag, 123 Pd—were injected in R3. Masses of 126 In, 125 Cd, and 123 Pd were measured whereby the mass uncertainty of 123 Pd was improved. This is the first reported measurement with a new storage ring mass spectrometry technique realized at a heavy-ion cyclotron and employing individual injection of the preidentified rare nuclei. The latter is essential for the future mass measurements of the rarest isotopes produced at RIBF. The impact of the new 123 Pd result on the solar r-process abundances in a neutron star merger event is investigated by performing reaction network calculations of 20 trajectories with varying electron fraction Y e . It is found that the neutron capture cross section on 123 Pd increases by a factor of 2.2 and β-delayed neutron emission probability, P 1n , of 123 Rh increases by 14%. The neutron capture cross section on 122 Pd decreases by a factor of 2.6 leading to pileup of material at A = 122, thus reproducing the trend of the solar r-process abundances. The trend of the two-neutron separation energies (S 2n ) was investigated for the Pd isotopic chain. The new mass measurement with improved uncertainty excludes large changes of the S 2n value at N = 77. Finally, such large increase of the S 2n values before N = 82 was proposed as an alternative to the quenching of the N = 82 shell gap to reproduce r-process abundances in the mass region of A = 112 – 124.

79 ASTRONOMY AND ASTROPHYSICS↗

Foundations of Molecular 'Isotomics'

The naturally occurring rare isotopes are versions of common elements, such as hydrogen, carbon and oxygen, that contain a larger than usual number of neutrons in their atomic nuclei and therefore are higher in mass than the common atoms of that element. Isotopes exist for most elements and are found in most natural and synthetic materials, but are uneven in their distribution because chemical and physical processes are isotope-selective (e.g., a chemical reaction may proceed more rapidly for one isotope than for another). For this reason, abundances of isotopes in a material of interest can provide a record, or ‘signature’ of various features of that material’s origin and history. These signatures have been used in the geo, life, chemical and physical sciences in a wide variety of ways over close to 8 decades. However, many such applications struggle to reach unique interpretations of isotopic data because multiple factors combine to control a given sample’s overall isotopic content. That is, the factors controlling isotopic content are too numerous and complex to fully constrain from a simple measurement of a material’s isotope abundances. However, the distribution of isotopes within materials, at molecular scales potentially provides a vastly larger number and diversity of constraints on the chemical and physical processes that comprise a material’s history. The rare isotopes may be concentrated into one atomic position in a molecule relative to another, some proportion of molecules in a sample may contain two or more rare isotopes, and those multiply-isotope-substituted forms of molecules may also have uneven distributions of those isotopes across individual atomic sites. For these reasons, even small, seemingly simple molecules, such as sugars, amino acids or drug compounds, actually exist in a vast number of isotopically unique forms (often millions or more), and each one of those forms is in some sense an independent ‘vote’ on that sample’s history. This project has focused on opening this rich archive of information by enabling the creation of routinely and widely applicable ways of measuring and interpreting isotopic structures of molecules. This work has included the development of core technologies and analytical methods, advancing fundamental understanding of the physical and chemical properties of isotopic versions of molecules, and conducting proof of concept studies of illustrative geochemical, cosmochemical and forensic problems in order to show how these technologies, methods and principles come together to solve problems in new ways. A key to the success of this project was the adaptation of ‘Fourier transform mass spectrometry’ (FTMS) to the task of precisely measuring proportions of the rare, naturally occurring isotopic forms of molecules. FTMS is a highly specialized form of mass spectrometry that traps ions within magnetic or electrostatic cavities and, effectively, ‘listens’ (through registering of subtle electrical signals) to the harmonic signals they make while rapidly orbiting within those cavities. These signals have periods that are a function of their mass and strength (or ‘loudness’) that is proportional to their abundances. Thus, these signals constrain relative amounts of molecules that differ in their mass due to various isotopic substitutions. This technology has been essential to the identification of organic molecules in the life, chemical and environmental sciences for over 4 decades, but generally has lacked the control, stability and precision to meaningfully measure rare isotope forms of molecules. This project’s most fundamental contribution has been to modify FTMS, both in terms of hardware and methods, to enable such measurements. The raw data of molecular isotopic structure is tremendously voluminous and complex, so another important activity of this project has been developing the theoretical and data-science tools needed to interpret the data generated by this new form of isotopic measurement. A particularly challenging part of this task has been predicting molecular isotopic structure, as only through the comparison of measurements with predictions can we make progress on hypothesis driven research questions. We have attacked this this prediction task through a combination of first-principles chemical-physics models of the effects of isotope substitution on molecule properties and data-science models that permit us to generalize that chemical physics to cases that have not yet been studied by detailed chemical physics theory. The proof of concept applications we have pursued over the course of this study include biological reactions of amino acids and other biomolecules, non-biological synthesis of organic molecules in extra-terrestrial settings such as meteorites, petroleum geoscience questions concerning the origin and evolution of natural gas, oil and kerogen compounds, and forensic questions such as the sourcing of chemical weapons. The successes of these applications have laid the groundwork for the next phase of this field’s development, which will include larger scale and more ambitious studies of molecular isotopic structure as a means of diagnosing human diseases, such as cancer, and reconstructing detailed interpretations of the origin and evolution of organic molecules in modern and geological environments.

Cesar, Jaime↗

Precision Mass Measurement of the Proton Dripline Halo Candidate 22 Al

Here, we report the first mass measurement of the proton-halo candidate 22 Al performed with the low energy beam ion trap facility’s 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. 22 Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al ., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of 22 Al , Phys. Rev. Lett. 125, 192503 (2020).]. The measured mass excess value of ME=18 092.5⁢(3) keV, corresponding to an exceptionally small proton separation energy of 𝑆𝑝=100.4⁢(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from 𝑠⁢𝑑-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the 22 Al ground state with minimal 1⁢𝑠 1/2 occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

binding energy↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

β -delayed charged-particle decay of Si 22 , 23

The β decay of 22,23 Si by emission of delayed charged particles was investigated in an experiment at the Cyclotron Institute of Texas A&M University by means of an optical-readout time-projection chamber. The previously-known decay of the two isotopes by β-delayed one- and two-proton emission was confirmed. Here for the first time, a new, rare, decay mode for 23 Si, β-delayed three-proton emission, was observed and β-delayed proton-α emission tentatively identified. Moreover, the β-decay pattern for the ground state of 23 Si was studied by means of multireference density-functional-rooted calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Unique Amphibole- and Magnetite-Rich Carbonaceous Chondrite from Almahata Sitta

Almahata Sitta (AhS) 202 from the UoK collection represents a clast from the polymict breccia asteroid 2008 TC3. AhS 202 was recognized as a unique carbonaceous chondrite (CC) with a high magnetite content. Here we report that it also contains a significant amount of amphibole, a mineral that is very rare in chondrites and has not previously been reported in significant abundance in a CC. We present new petrographic, oxygen isotope, and micro-FTIR data. We discuss petrogenesis and possible relationships to known CC.

Goodrich, C. A.↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Motivations for early high-profile FRIB experiments

This white paper is the result of a collaboration by many of those that attended a workshop at the facility for rare isotope beams (FRIB), organized by the FRIB Theory Alliance (FRIB-TA), on ‘Theoretical Justifications and Motivations for Early High-Profile FRIB Experiments’. It covers a wide range of topics related to the science that will be explored at FRIB. After a brief introduction, the sections address: section 2: Overview of theoretical methods, section 3: Experimental capabilities, section 4: Structure, section 5: Near-threshold Physics, section 6: Reaction mechanisms, section 7: Nuclear equations of state, section 8: Nuclear astrophysics, section 9: Fundamental symmetries, and section 10: Experimental design and uncertainty quantification.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rate-induced aging effects on Parallel-Plate Avalanche Counter (PPAC) caused by heavy ion beams

The Facility for Rare Isotope Beams (FRIB) is one of the premier scientific user facilities for nuclear science with radioactive beams, capable of producing most (approximately 80%) of the isotopes expected to exist, from oxygen to uranium, at energies up to 200 MeV/u. With the increase in beam power from the present 10 kW to the planned 400 kW, FRIB experiments are about to enter a new era. An unprecedented rate capability as well as stable performance of all the planned instrumentation intended for beam diagnostics and beam tuning is required at the expected high beam intensities (> 1 MHz). A summary of aging phenomena at high heavy-ion beam rates observed in the Advanced Rare Isotope Separator (ARIS) detectors for beam diagnostics, including Parallel Plate Avalanche Counters (PPAC) and plastic scintillation for time-of-flight measurements, is discussed. Current research and development project to mitigate rate-induced aging are presented.

Aging effects↗

Experimental determinations of carbon and hydrogen isotope fractionations and methane clumped isotope compositions associated with ethane pyrolysis from 550 to 600°C

Methane clumped isotope compositions signify the relative natural abundances of rare, doubly substituted isotopic species of methane ( 13 CH 3 D and 12 CH 2 D 2 ) and have emerged as a new isotopic tool to trace the sources, sinks, and lifecycles of methane in the environment. Such measurements can identify equilibration (or reequilibration) temperatures if found to be in isotopic equilibrium or non-equilibrium processes (e.g., kinetically controlled reactions or mixing) if not in isotopic equilibrium. Naturally occurring thermogenic methane—formed by the thermally activated breakdown of larger organic molecules—has been found to have clumped isotope compositions consistent with equilibrium at reasonable gas formation temperatures in some settings and non-equilibrium processes occurring during either formation, migration, storage, or extraction in others. To explore the potential controls on the isotopic composition of thermogenic methane, we conducted isothermal time-series ethane pyrolysis experiments at 550 and 600 °C to measure methane and ethane 13 C/ 12 C and D/H fractionations and methane clumped isotope compositions (resolved 13 CH 3 D and 12 CH 2 D 2 ). We explore the effects of modifying the initial clumped isotope composition of ethane and the addition of water vapor to pyrolysis experiments. We observe that ethane and methane 13 C/ 12 C are controlled by kinetic isotope effects and Rayleigh distillation processes. In contrast, ethane and methane D/H and methane clumped isotope compositions appear to be controlled by a combination of these processes and hydrogen isotope exchange. The hydrogen isotope exchange processes lead to isotopic equilibrium as reaction completion is approached for both D/H (ethane/methane) and methane clumped isotope compositions. Here, we develop a chemical model based on a mass balance approach that accounts for inheritance vs. hydrogen-abstraction formation pathways for singly and doubly substituted isotopologues of ethane and methane that is compared to the experimental data. The model allows the determination of carbon and hydrogen kinetic isotope effects associated with ethane cracking and hydrogen abstraction reactions that, where applicable, we compare to prior theoretical constraints. From the comparison of the model to the experimental data, we infer that the kinetically controlled ethane and methane bulk isotope compositions and methane clumped isotope compositions are controlled by kinetic isotope effects (both primary and secondary) associated with both C–C bond and C–H bond cleavage reactions. Specifically, the methane clumped isotope compositions likely result from a combination of clumped isotope effects associated with ethane breakdown and/or assembly of methane isotopologues (expressed in terms of γ-factor parameters ≠ 1) and combinatorial effects that arise probabilistically. We discuss our experimental results in the context of recent pyrolysis experiments and observations of naturally occurring thermogenic methane. We consider a proposal consistent with observations from nature that the hydrogen isotope exchange reactions that promote equilibration of methane isotopic molecules at or near formation temperature may be facilitated by free radicals generated by pyrolysis reactions. In this framework, isotope exchange effectively ceases when pyrolysis effectively ceases locking in compositions that can be consistent with peak formation temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NACS 2022 FRIB Investment Strategy

The Facility for Rare Isotope Beams (FRIB) that will begin operations later this year will vastly increase the number of unstable isotopes available for experiments that, together with new theoretical developments will expand our understanding of nuclear structure and nuclear reactions that produce the elements of the periodic table and power the cosmos. The knowledge and understanding gained from FRIB will benefit a variety of applications including stockpile science, nuclear forensics, nonproliferation, nuclear energy, and nuclear medicine. LLNL is actively involved in a variety of basic and applied science activities related to FRIB. These activities are listed below and documented in the following sections: 1. FRIB Decay Station, 2. Isotope Harvesting, 3. Direct Reactions, 4. Surrogate Reactions, 5. Nuclear Structure and Collectivity, 6. Nuclear Fission, and 7. Nuclear Theory.

07 ISOTOPE AND RADIATION SOURCES↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗