Search NASA⌕ Search

SEARCH · Search NASA

Results for “Refilling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluation of Pulse Jet Mixer Concentration Profiles to Track Slurry Suspension

A series of tests were conducted to evaluate the mixing performance of pulse jet mixers. A pulse-jet mixing system involves an array of pulse tubes with nozzles directed toward the vessel floor inside the mixing vessel. Fluid is expelled from the pulse tubes during the drive portion of the PJM cycle. Fluid refills into the pulse tubes during the refill portion of the PJM cycle. This cyclical process can be used to mix slurries. Concentration profiles as a function of location and elevation in the tank were taken during the pulse jet mixer cycle at several radial locations within the mixing vessel: at the center, near the wall, and half-way between the center and the wall. The data are being examined to determine how the time during the cycle affects the solids suspension and settling. Examples will be presented for several particle types, concentrations, and pulse-jet operating conditions.

concentration profile↗

Estimated vapor pressure for WTP process streams

Design assumptions during the vacuum refill phase of the Pulsed Jet Mixers (PJMs) in the Hanford Waste Treatment and Immobilization Plant (WTP) equate the vapor pressure of all process streams to that of water when calculating the temperature at which the vacuum refill is reduced or eliminated. WTP design authority asked the authors to assess this assumption by performing calculations on proposed feed slurries to calculate the vapor pressure as a function of temperature. The vapor pressure was estimated for each WTP waste group. The vapor pressure suppression caused by dissolved solids is much greater than the increase caused by organic components such that the vapor pressure for all of the waste group compositions is less than that of pure water. The vapor pressure for each group at 145°F ranges from 81% to 98% of the vapor pressure of water. If desired, the PJM could be operated at higher temperatures for waste groups with high dissolved solids that suppress vapor pressure. The SO4 group with the highest vapor pressure suppression could be operated up to 153°F before reaching the same vapor pressure of water at 145°F. However, most groups would reach equivalent vapor pressure at 147 to 148°F. If any of these waste streams are diluted, the vapor pressure can exceed the vapor pressure of water at mass dilution ratios greater than 10, but the overall effect is less than 0.5%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Centaur propellant acquisition system study

A study was performed to determine the desirability of replacing the hydrogen peroxide settling system on the Centaur D-1S with a capillary acquisition system. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump in order to provide necessary net position suction head (NPSH). Design drawings were prepared for the start basket and start tank concepts for both LO2 and LH2 tanks. System comparisons indicated that the start baskets using wicking for thermal conditioning, and thermal subcooling for boost pump NPSH, are the most desirable systems for future development.

Blatt, M. H.↗

Centaur propellant acquisition system

The desirability of replacing the hydrogen peroxide settling system of the Centaur D-1S with a capillary acquisition system was evaluated. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump to provide the necessary net positive suction head (NPSH). Design drawings were prepared for start basket and start tank concepts for both the liquid oxygen and liquid hydrogen tanks. System comparisons indicated that the start baskets using wicking flow for thermal conditioning, and thermal subcooling for providing boost pump NPSH, are the most desirable systems for future Centaur acquisition system development.

Blatt, M. H.↗

Study of liquid and vapor flow into a Centaur capillary device

The following areas of liquid and vapor flow were analyzed and experimentally evaluated; 1) the refilling of capillary devices with settled liquid, and 2) vapor flow across wetted screens. These investigations resulted in: 1) the development of a versatile computer program that was successfully correlated with test data and used to predict Centaur D-1S LO2 and LH2 start basket refilling; 2) the development of a semi-empirical model that was only partially correlated with data due to difficulties in obtaining repeatable test results. Also, a comparison was made to determine the best propellant management system for the Centaur D-1S vehicle. The comparison identified the basline Centaur D-1S system (using pressurization, boost pumps and propellant settling) as the best candidate based on payload weight penalty. However, other comparison criteria and advanced mission condition were identified where pressure fed systems, thermally subcooled boost pumps and capillary devices would be selected as attractive alternatives.

Blatt, M. H.↗

Capillary acquisition devices for high-performance vehicles: Executive summary

Technology areas critical to the development of cryogenic capillary devices were studied. Passive cooling of capillary devices was investigated with an analytical and experimental study of wicking flow. Capillary device refilling with settled fluid was studied using an analytical and experimental program that resulted in successful correlation of a versatile computer program with test data. The program was used to predict Centaur D-1S LO2 and LH2 start basket refilling. Comparisons were made between the baseline Centaur D-1S propellant feed system and feed system alternatives including systems using capillary devices. The preferred concepts from the Centaur D-1S study were examined for APOTV and POTV vehicles for delivery and round trip transfer of payloads between LEO and GEO. Mission profiles were determined to provide propellant usage timelines and the payload partials were defined.

Blatt, M. H.↗

Characteristics of thermal and suprathermal ions associated with the dayside plasma trough as measured by the dynamics explorer retarding ion mass spectrometer

The thermal and suprathermal ion populations present in the refilling regions after a magnetic storm are examined using retarding ion mass spectrometer (RIMS) data from the Dynamics Explorer 1 spacecraft. The RIMS instrument is described, and data are presented and discussed in detail for the outer plasmasphere, plasmapause, depleted dayside magnetosphere, and dayside cusp. Three distinct populations were observed: thermal ions, warm anisotropic plasma, and the polar wind. The characteristics of these populations are considered, including the densities, temperatures, and density ratios. Aspects of the ionospheric plasma outflow are discussed, including the field-aligned flow speed, the ionospheric plasma escape flux, plasmaspheric refilling, and wave-particle phenomena.

Sojka, J. J.↗

Superfluid helium on orbit transfer (SHOOT)

A number of space flight experiments and entire facilities require superfluid helium as a coolant. Among these are the Space Infrared Telescope Facility (SIRTF), the Large Deployable Reflector (LDR), the Advanced X-ray Astrophysics Facility (AXAF), the Particle Astrophysics Magnet Facility (PAMF or Astromag), and perhaps even a future Hubble Space Telescope (HST) instrument. Because these systems are required to have long operational lifetimes, a means to replenish the liquid helium, which is exhausted in the cooling process, is required. The most efficient method of replenishment is to refill the helium dewars on orbit with superfluid helium (liquid helium below 2.17 Kelvin). To develop and prove the technology required for this liquid helium refill, a program of ground and flight testing was begun. The flight demonstration is baselined as a two flight program. The first, described in this paper, will prove the concepts involved at both the component and system level. The second flight will demonstrate active astronaut involvement and semi-automated operation. The current target date for the first launch is early 1991.

Dipirro, Michael J.↗

Multistream hydrodynamic modeling of interhemispheric plasma flow

Interhemispheric plasma flow was simulated using one-stream and two-stream hydrodymic models in order to test the suggestion of Banks et al. (1971) and others that the collision of high-speed flows originating from the conjugate hemispheres will cause the formation of a pair of shocks. The single-fluid hydrodynamic equations were modified to include multiple ion streams, allowing for the possibility of counterstreaming flow. It was found that a counterstreaming of ion streams from conjugate hemispheres does occur during the early stages of the refilling of plamaspheric flux tubes, and that a pair of reverse shocks does form. These shocks form away from the equator, and their subsequent motion creates conditions similar to those predicted by the single-stream hydrodynamic models. The findings support the conclusion of earlier studies that the refilling of the plasmasphere occurs from the equatorial region downward.

Rasmussen, C. E.↗

Fluid Acquisition and Resupply Experiment (FARE-I) flight results

The Fluid Acquisition and Resupply Experiment, (FARE) is a Shuttle middeck-mounted experiment to demonstrate techniques for handling liquids in zero gravity for operations such as refueling spacecraft in orbit. The first flight took place on STS 53 launched December 2, 1992. Eight tests were performed during the mission and the experiment achieved 100 percent mission success. The second flight will be on STS 57, scheduled for launch in June 1993. The objective of FARE I was to demonstrate techniques for controlling the position of the liquid and gas within a tank during refilling and to better understand the operation of screen-type surface tension devices used to drain tanks in zero gravity. Tests were performed to demonstrate tank refilling, low gravity propellant slosh, and expulsion efficiency of the screen device. Expulsion efficiencies of 97 percent - 98 percent were demonstrated under a variety of flowrates and accelerations. Final fill levels of 60 percent to 80 percent were achieved during the vented fill tests.

Dominick, Sam M.↗

Kinetic plasma processes occurring in the outer plasmasphere

One area of data analysis work that was begun under this contract is the fitting of the perpendicular velocity distributions of equatorially trapped ions with a Kappa function. This type of characterization of the trapped ions will be very useful for comparison with velocity distributions produced by the model. A second area of data analysis is to study data from consecutive passes when DE 1's apogee was near the magnetic equator and the spacecraft was often skimming along nearly the same L shell. In 1982 three such periods occurred in May, June, and July. For these consecutive events we have Kp histories, density measurements from a number of sources (Whistler data, DE SFR, ISEE SFR) and consecutive samples of ion pitch angle distributions along field lines. It is clear from this data how the pitch angle distributions evolve during a flux tube refilling event. Our modeling of the flow of plasma along closed field lines is following two basic tracks. The first is a study of the basic refilling process without the effect of wave-particle heating near the equator or the effect of large or abrupt field-aligned electric potential drops. This model includes the effects of Coulomb self-collisions and collisions with the O+ ions in the topside ionosphere. The second track is a study of the effects of wave produced pitch-angle scattering and perpendicular heating occurring near the magnetic equator, in connection with the development of large potential drops that result from electron heating and the development of density gradients.

Wilson, Gordon R.↗

Equatorial heating and hemispheric decoupling effects on inner magnetospheric core plasma evolution

We have extended our previous semikinetic study of early stage plasmasphere refilling with perpendicular ion heating by removing the restriction that the northern and southern boundaries are identical and incorporating a generalized transport description for the electrons. This allows investigation of the effects of electron heating and a more realistic calculation of electric fields produced by ion and electron temperature anisotropies. The combination of perpendicular ion heating and parallel electron heating leads to an equatorial electrostatic potential peak, which tends to shield and decouple ion flows in the northern and southern hemispheres. Unequal ionospheric upflows in the northern and southern hemispheres lead to the development of distinctly asymmetric densities and other bulk parameters. At t = 5 hour after the initiation of refiling with different source densities (N(sub north) = 100 cu/cm, N(sub south) = 50 cu/cm), the maximum potential drops of the northern and southern hemispheres are 0.6 and 1.3 V, respectively. At this time the minimum ion densities are 11 and 7 cu/cm for the northern and southern hemispheres. DE 1 observations of asymmetric density profiles by Olsen may be consistent with these predictions. Termination of particle heating causes the reduction of equatorial potential and allows interhemispheric coupling. When the inflows from the ionospheres are reduced (as may occur after sunset), decreases in plasma density near the ionospheric regions are observed while the heated trapped ion population at the equator persists.

Lin, J.↗

Plasmaspheric Density Troughs: Global IMAGE EUV Observations and Analysis via Global Core Plasma Modeling

To date, the IMAGE EUV camera has observed several plasmaspheric density trough features inside the plasmapause under a wide range of geomagnetic activity. From the perspective of EUV, a density trough feature appears as a channel of diminished pixel counts which spans a width of L-shell (DELTA L) and magnetic local time (MLT) inside the plasmapause. Plasmaspheric density troughs are found to be morphologically complex possessing considerable spatial and temporal variability. We present an analysis of the evolution of trough DELTA L and MLT extent as functions of associated D (sub ST) and K (sub p) history. Trough features range in size from 0.16 less than or equal to DELTA L less than or equal to 1.2 with azimuthal extent from 1500 less than or equal to MLT less than or equal to 1200. All cases of plasmaspheric density troughs studied to date appear to have evolved as a result of the inner edge of the afternoon/evening plasma drainage plume being wrapped around through the nightside plasmasphere. The structure of plasmaspheric density trough features is further probed by analyzing simulated EUV images produced by forward modeling artificially introduced regions of depleted density into both static and dynamic global core plasmaspheric models. Forward modeling suggests that (1) L-shell refilling of density troughs during storm recovery can be modeled as filling from the ionosphere toward the equator (i.e., bottom-up refilling), and (2) that an erosion process is operating within flux tubes beyond the outer L-shell wall of the observed density troughs.

Adrian, M. L.↗

Plasmasphere Empirical Modeling with the IMAGE Mission

Empirical models of plasmaspheric properties date from the pioneering work of Storey where he developed the analysis of ground whistler observations that lead to his estimate for the equatorial plasma density at L=3. The most recent in situ satellite study takes us to 1000 CRRES satellite passes and a statistical analysis of the plasmapause location at all local times and for varying geomagnetic conditions by Moldwin et al. These and many other studies over the intervening 49 years have given us a strong familiarity with the distribution of cold plasmaspheric ions throughout the magnetosphere. The major components of inner plasmasphere, nightside bulge, sunward convection tail, and plasmapause are all well established. Storm-time erosion and the resulting ionospheric refilling has been encompassed, even if not completely understood. Small-scale density variations near the plasmapause and extending at least to geosynchronous orbit have been characterized in a variety of ways, even though we do not yet understand their origin. This paper will present early empirical modeling results from the inversion of IMAGE/EW global intensity images to density distributions. Densities are obtained in this initial study through use of forward image modeling with a simple 3-parameter plasmaspheric and plasmapause mathematical model. Individual interior plasmaspheric density profiles and plasmapause locations are obtained every 10 degrees in magnetic local time for each E W image analyzed. Derived profile parameters are statistically characterized in the context of storm magnitude and evolution. Identified patterns in the appearance of plasmaspheric structures, plasmapause erosion, and refilling will be presented. Comparisons to existing empirical plasmaspheric models and the implications for new modeling will be presented. Additional information is included in the original extended abstract.

Gallagher, D. L.↗

First Results from ARTEMIS, a New Two-Spacecraft Lunar Mission: Counter-Streaming Plasma Populations in the Lunar Wake

We present observations from the first passage through the lunar plasma wake by one of two spacecraft comprising ARTEMIS (Acceleration, Reconnection, Turbulence, and Electrodynamics of the Moon's Interaction with the Sun), a new lunar mission that re-tasks two of five probes from the THEMIS magnetospheric mission. On Feb 13, 2010, ARTEMIS probe P1 passed through the wake at 3.5 lunar radii downstream from the Moon, in a region between those explored by Wind and the Lunar Prospector, Kaguya, Chandrayaan, and Chang'E missions. ARTEMIS observed interpenetrating proton, alpha particle, and electron populations refilling the wake along magnetic field lines from both flanks. The characteristics of these distributions match expectations from self-similar models of plasma expansion into vacuum, with an asymmetric character likely driven by a combination of a tilted interplanetary magnetic field and an anisotropic incident solar wind electron population. On this flyby, ARTEMIS provided unprecedented measurements of the interpenetrating beams of both electrons and ions naturally produced by the filtration and acceleration effects of electric fields set up during the refilling process. ARTEMIS also measured electrostatic oscillations closely correlated with counter-streaming electron beams in the wake, as previously hypothesized but never before directly measured. These observations demonstrate the capability of the comprehensively instrumented ARTEMIS spacecraft and the potential for new lunar science from this unique two spacecraft constellation.

Halekas, J. S.↗

The ISS 2B PVTCS Ammonia Leak: An Operational History

In 2006, the Photovoltaic Thermal Control System (PVTCS) for the International Space Station's 2B power channel began leaking ammonia at a rate of approximately 1.5lbm/year (out of a starting approximately 53lbm system ammonia mass). Initially, the operations strategy was "feed the leak," a strategy successfully put into action via Extra Vehicular Activity during the STS‐134 mission. During this mission the system was topped off with ammonia piped over from a separate thermal control system. This recharge was to have allowed for continued power channel operation into 2014 or 2015, at which point another EVA would have been required. Without these periodic EVAs to refill the 2B coolant system, the channel would eventually leak enough fluid as to risk pump cavitation and system failure, resulting in the loss of the 2B power channel - the most critical of the Space Station's 8 power channels. In mid‐2012, the leak rate increased to approximately 5lbm/year. Once discovered, an EVA was planned and executed within a 5 week timeframe to drastically alter the architecture of the PVTCS via connection to a dormant thermal control system not intended to be utilized as anything other than spare components. The purpose of this rerouting of the TCS was to increase system volume and to isolate the photovoltaic radiator, thought to be the likely leak source. This EVA was successfully executed on November 1st, 2012 and left the 2B PVTCS in a configuration where the system was now being adequately cooled via a totally different radiator than what the system was designed to utilize. Unfortunately, data monitoring over the next several months showed that the isolated radiator was not leaking, and the system itself continued to leak steadily until May 9th, 2013. It was on this day that the ISS crew noticed the visible presence of ammonia crystals escaping from the 2B channel's truss segment, signifying a rapid acceleration of the leak from 5lbm/year to 5lbm/day. Within 48 hours of the crew noticing the leak, an EVA was in progress to replace the coolant pump - the only other replaceable leak source. This paper will explore the management of the 2B PVTCS leak from the operations perspective. It will discuss the methodology of performing the STS‐134 refill, the considerations and contingency plans which went into the architectural overhaul of the system in 2012, and the unprecedented effort which went into the EVA response to the visible leak of May 2013. In particular the paper will focus on the techniques utilized by flight controllers to monitor the system health and to respond to such instances as the rapid May 2013 leak by putting the electrical system in a safe configuration for loss of cooling, and will use recorded telemetry of these events to describe system response to EVA crew and ground actions. It will discuss the innovative design for redundancy of the integrated truss structure's cooling systems which allowed for this leak to be managed with minimal impact to other ISS operations and electrical services, contrasted against the real unintended operations consequences of utilizing the flexibility of the spacecraft's design in this manner. The paper will discuss how the training of the crew and flight controller personnel has adapted to the changing architecture of the power system and the unpredictable nature of the 2B leak.

Vareha, Anthony↗

Investigation of VEGGIE Root Mat

VEGGIE is a plant growth facility that utilizes the phenomenon of capillary action as its primary watering system. A cloth made of Meta Aramid fiber, known as Nomex is used to wick water up from a reservoir to the bottom of the plants roots. This root mat system is intended to be low maintenance with no moving parts and requires minimal crew interface time. Unfortunately, the water wicking rates are inconsistent throughout the plant life cycle, thus causing plants to die. Over-wicking of water occurs toward the beginning of the cycle, while under-wicking occurs toward the middle. This inconsistency of wicking has become a major issue, drastically inhibiting plant growth. The primary objective is to determine the root cause of the inconsistent wicking through experimental testing. Suspect causes for the capillary water column to break include: a vacuum effect due to a negative pressure gradient in the water reservoir, contamination of material due to minerals in water and back wash from plant fertilizer, induced air bubbles while using syringe refill method, and material limitations of Nomex's ability to absorb and retain water. Experimental testing will be conducted to systematically determine the cause of under and over-wicking. Pressure gages will be used to determine pressure drop during the course of the plant life cycle and during the water refill process. A debubbler device will be connected to a root mat in order to equalize pressure inside the reservoir. Moisture and evaporation tests will simultaneously be implemented to observe moisture content and wicking rates over the course of a plant cycle. Water retention tests will be performed using strips of Nomex to determine materials wicking rates, porosity, and absorptivity. Through these experimental tests, we will have a better understanding of material properties of Nomex, as well as determine the root cause of water column breakage. With consistent test results, a forward plan can be achieved to resolve the issue and give valuable insight for the next generation of VEGGIE.

Subbiah, Arun M.↗

First Results from ARTEMIS, A New Two-Spacecraft Lunar Mission: Counter-Streaming Plasma Populations in the Lunar Wake

We present observations from the first passage through the lunar plasma wake by one of two spacecraft comprising ARTEMIS (Acceleration, Reconnection, Turbulence, and Electrodynamics of the Moon's Interaction with the Sun), a new lunar mission that re-tasks two of five probes from the THEMIS magnetospheric mission. On Feb 13, 2010, ARTEMIS probe P1 passed through the wake at approximately 3.5 lunar radii downstream from the Moon, in a region between those explored by Wind and the Lunar Prospector, Kaguya, Chandrayaan, and Chang'E missions. ARTEMIS observed interpenetrating proton, alpha particle, and electron populations refilling the wake along magnetic field lines from both flanks. The characteristics of these distributions match expectations from self-similar models of plasma expansion into vacuum, with an asymmetric character likely driven by a combination of a tilted interplanetary magnetic field and an anisotropic incident solar wind electron population. On this flyby, ARTEMIS provided unprecedented measurements of the interpenetrating beams of both electrons and ions naturally produced by the filtration and acceleration effects of electric fields set up during the refilling process. ARTEMIS also measured electrostatic oscillations closely correlated with counter-streaming electron beams in the wake, as previously hypothesized but never before directly measured. These observations demonstrate the capability of the comprehensively instrumented ARTEMIS spacecraft and the potential for new lunar science from this unique two spacecraft constellation.

Plasma↗