Neutron Reflectometry Reveals Diffusion in Contrast-Matched Brush Particle Bilayers

A material system for performing layer-spread experiments on brush particle bilayers is presented and used to determine the diffusion constant of brush particles in the melt state. Selective deuteration of the core and shell of organo-silica nanoparticles grafted with poly(methyl methacrylate) was used to match the scattering length density of the core and the polymer canopy layer. This subdued the scattering of particle cores (i.e., formfactor scattering) and enabled the analysis of the interdiffusion kinetics using neutron reflectivity. For low molecular grafts, i.e., grafts with a molecular weight below the entanglement limit, the interdiffusion kinetics revealed both a sub- and Fickian diffusion regime. The former was attributed to the local dynamics that was constrained by the slow-moving cores of neighboring brush particles that acted as long-lived physical cross-links. No transition to Fickian diffusion was observed for entangled systems, even at prolonged annealing times. This suggested a higher level of kinetic restraint in entangled brush particle melts as compared to, for example, star polymers with a comparable chain length for which Fickian diffusion has been reported under similar conditions.

Diffusion, Polymer Grafted Nanoparticles, Neutron ↗

Assessment of the degree of hydration of ocular surface tissues using THz reflectometry

Using the effective medium model, the complex permittivity of the ocular surface system in the THz frequency range is considered. The penetration depth of THz radiation and the sensitivity of the reflected component to the dynamics of evaporation of the tear film are discussed. The results of in vivo experiments aimed to determine the reflection coefficient of the ocular surface using continuous THz reflectometers are well described using the developed model. (paper)

36 MATERIALS SCIENCE↗

Radio Frequency Field Programable Gate Array Implementation of Reflectometry Cable Monitoring

PNNL has developed an innovative cable testing system that leverages the Xilinx RF System-on-Chip (RFSoC) technology to create a more flexible and capable measurement tool than traditional approaches. The architecture is designed on the ZCU111 development board and takes advantage of the high-speed digital to analog converters (DAC) and analog to digital converters (ADC) to generate and capture digitally synthesized waveforms. The platform allows engineers to easily adjust power, frequency, duration and modulation on the fly rather than being locked into fixed hardware configurations

Tedeschi, Jonathan [Pacific Northwest National Lab↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

Ultrasonic waveguide reflectometry for quench detection (CRADA Final Report)

Early detection of thermal runaway (quench) is critical for safely operating high-temperature superconductor (HTS) magnets. Voltage-based techniques provide late detection of quenching in HTS, which can lead to magnet burnout and system damage. Various non-voltage quench-detection approaches are therefore investigated nowadays that are based on magnetic, acoustic, and optical sensing. LBNL has been actively developing the quench detection principle based on diffuse ultrasonic wave propagation since 2017 and has demonstrated the approach's viability with several peer-reviewed publications and a patent application. Over the last decade, Etegent, LBNL partner for this proposal and effort, has been developing a sensing technology that utilizes the propagation of stress waves through the solid metallic and nonmetallic waveguides (WG). The method is based on the dependence of materials' elastic properties and the speed of sound on temperature. Compared with optical analog, acoustic WG operates at much lower frequencies, eliminating the need for expensive, complex, highly sensitive receivers and data processing. Etegent proved this technology in many harsh environments, mainly concentrated high-temperature measurements. The initial contact between LBNL and Etegent started in 2020, aiming at combining our knowledge and effort toward developing a viable ultrasound-based quench detection technique for use with HTS magnets. A preliminary study conducted jointly in 2022 found no principle restrictions for expanding the WG technology toward cryogenic temperature operation. The present CRADA work aimed at designing, building, and testing ultrasonic waveguide temperature sensors at relevant cryogenic conditions, and demonstrating this technology's applicability to detecting heating and quenching in High Temperature Superconductor (HTS)-based cables and magnets. The technical objectives of the project included: (1) Design and fabricate ultrasonic WG sensors suitable for cryogenic operation, (2) Test ultrasonic WGs under cryogenic conditions, (3) Determining a suitable way of insulating WGs to prevent ultrasonic leakage while maintaining good thermal contact with the surrounding medium, (4) WG integration and cryogenic test with HTS conductors and HTS magnets, and (5) Design and basic prototyping of a standalone WG-based quench detection system. This project adds value to the present LBNL magnet diagnostics portfolio and enables a breakthrough in addressing the HTS magnet quench detection challenge.

47 OTHER INSTRUMENTATION↗

High resolution density pedestal measurements during edge localized modes by short-pulse reflectometry in the TCV tokamak

This publication presents high spatio-temporal resolution (mm/μs) density profile measurements of the pedestal top during type I, III, and small edge localized mode (ELM) H-mode plasmas in the Tokamak à Configuration Variable (TCV). These measurements were performed using a novel short-pulse reflectometer. Average inter-ELM density profiles are obtained via conditional averaging using the Dα trace as ELM indicator. Changes to the pedestal density profile gradients prior to type-III ELMs reveal unique pedestal dynamics leading to the ELM crash which can provide important experimental data for validation of non-linear MHD ELM simulations. The small-ELM scenario is found to feature a ∼25-35 kHz quasi-coherent density fluctuation near the separatrix rho_psi ∼0.993-1.05 not observed during a similar type-I ELM discharge. This oscillation is also found in low-field-side magnetic pick- up probes displaying a ballooning character and n=+1 toroidal mode number. This oscillation could help explain the markedly different pedestal dynamics observed in the small-ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A SSTDR Methodology, Implementations, and Challenges

Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.

14 SOLAR ENERGY↗

Studying Transient Phenomena in Thin Films with Reinforcement Learning

Neutron reflectometry has long been a powerful tool to study the interfacial properties of energy materials. Recently, time-resolved neutron reflectometry has been used to better understand transient phenomena in electrochemical systems. Those measurements often comprise a large number of reflectivity curves acquired over a narrow q range, with each individual curve having lower information content compared to a typical steady-state measurement. In this work, we present an approach that leverages existing reinforcement learning tools to model time-resolved data to extract the time evolution of structure parameters. Further, by mapping the reflectivity curves taken at different times as individual states, we use the Soft Actor-Critic algorithm to optimize the time series of structure parameters that best represent the evolution of an electrochemical system. We show that this approach constitutes an elegant solution to the modeling of time-resolved neutron reflectometry data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Measurement of Buried Electrolyte–Electrode Interfaces for Solid State Batteries with Nanometer Level Precision

Many technologies including high-energy solid-state batteries rely on high quality solid–solid interfaces. Solid–solid interfaces are particularly difficult to study as their nature requires the interface to be buried. Here, in this work, we demonstrate the use of a combination of neutron reflectometry and in situ electrochemistry to measure the interface between Li metal and the solid electrolyte LiPON across an 8 cm 2 area. Neutron reflectometry measurements confirm the interphase to be less than 7 nm thick. The neutron reflectometry data further emphasize that the interphase that forms is a chemical gradient consisting of a Li-rich layer that gradually decreases in Li content until it blends into pure LiPON. Experimental confirmation that we can make ideal solid–solid interphases less than 10 nm thick will help facilitate the adoption of high efficiency next generation solid state batteries. Further this combination of complementary techniques provides a more general methodology for studying buried solid–solid interfaces across applications.

25 ENERGY STORAGE↗

Reconstructing the reflectivity of liquid surfaces from grazing incidence X-ray off-specular scattering data

The capillary wave model of a liquid surface predicts both the X-ray specular reflection and the diffuse scattering around it. A quantitative method is presented to obtain the X-ray reflectivity (XRR) from a liquid surface through the diffuse scattering data around the specular reflection measured using a grazing incidence X-ray off-specular scattering (GIXOS) geometry at a fixed horizontal offset angle with respect to the plane of incidence. With this approach the entire Q z -dependent reflectivity profile can be obtained at a single, fixed incident angle. This permits a much faster acquisition of the profile than with conventional reflectometry, where the incident angle must be scanned point by point to obtain a Q z -dependent profile. The XRR derived from the GIXOS-measured diffuse scattering, referred to in this paper as pseudo-reflectivity, provides a larger Q z range compared with the reflectivity measured by conventional reflectometry. Transforming the GIXOS-measured diffuse scattering profile to pseudo-XRR opens up the GIXOS method to widely available specular XRR analysis software tools. Here the GIXOS-derived pseudo-XRR is compared with the XRR measured by specular reflectometry from two simple vapor–liquid interfaces at different surface tension, and from a hexadecyltrimethylammonium bromide monolayer on a water surface. For the simple liquids, excellent agreement (beyond 11 orders of magnitude in signal) is found between the two methods, supporting the approach of using GIXOS-measured diffuse scattering to derive reflectivities. Pseudo-XRR obtained at different horizontal offset angles with respect to the plane of incidence yields indistinguishable results, and this supports the robustness of the GIXOS-XRR approach. The pseudo-XRR method can be extended to soft thin films on a liquid surface, and criteria are established for the applicability of the approach.

36 MATERIALS SCIENCE↗

Influence of Grafting Density and the Ionic Environment on the Structure of Zwitterionic Brushes

Zwitterionic polymer brushes possess a high potential for applications as surface coatings, e.g., in antifouling applications. Their complex association behavior due to the coexistence of oppositely charged groups on the same monomeric unit allows for a broad variation of polarity, hydrophilicity, and the antipolyelectrolyte effect with the variation of the surrounding environment. In this study, planar polysulfobetaine brushes were investigated with neutron reflectometry (NR) and neutron spin–echo spectroscopy under grazing incidence (GINSES) to explore the brush structure and its inner dynamics perpendicular to the substrate. In particular, the effects of the substrate–initiator system and ionic strength on the structure were investigated with neutron reflectometry and a swelling by a factor of 3–5 was found in the presence of aqueous NaCl and MgCl 2 solutions compared to the dry state. During the data analysis, the applicability of a model-free evaluation was also demonstrated for the investigated polysulfobetaine brushes. Furthermore, it was found with GINSES that in contrast to neutral brushes, these polysulfobetaine brushes do not show the typical concentration fluctuations in the nanosecond time range when partially swollen with salt-free water.