Search NASA⌕ Search

SEARCH · Search NASA

Results for “Related References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fracture toughness testing data. A bibliography

This bibliography is comprised of approximately 800 reference citations related to the mechanics of failure in aerospace structures. Most of the references are for documents that include fracture toughness testing data and its application or documents on the availability and usefulness of fracture mechanics analysis methodology. The bibliography represents a search of the literature published in the period April 1962 through April 1974 and is largely limited to documents published in the United States.

Carpenter, J. L., Jr.↗

Life prediction of materials exposed to monotonic and cyclic loading: Bibliography

This bibliography is comprised of approximately 1200 reference citations related to the mechanics of failure in aerospace structures. Most of the references are for information on life prediction for materials exposed to monotonic and cyclic loading in elevated temperature environments such as that in the hot end of a gas turbine engine. Additional citations listed are for documents on the thermal and mechanical effects on solar cells in the cryogenic vacuum environment; radiation effects on high temperature mechanical properties; and high cycle fatigue technology as applicable to gas turbine engine bearings. The bibliography represents a search of the literature published in the period April 1962 through April 1974 and is largely limited to documents published in the United States. It is a companion volume to NASA CR-134750, Life Prediction of Materials Exposed to Monotonic and cyclic Loading - A Technology Survey.

Carpenter, J. L., Jr.↗

Evaluating Light Source Color Rendition using the IES TM-30-15 Method

A system for evaluating the color rendition of light sources was recently published as IES TM-30-15 IES Method for Evaluating Light Source Color Rendition. The system includes a fidelity index (Rf) to quantify similarity to a reference illuminant, a relative-gamut index (Rg) to quantify saturation relative to a reference illuminant, and a color vector icon that visually presents information about color rendition. The calculation employs CAM02-UCS and uses a newly-developed set of reflectance functions, comprising 99 color evaluation samples (CES). The CES were down-selected from 105,000 real object samples and are uniformly distributed in color space (fairly representing different colors) and wavelength space (avoiding artificial increase of color rendition values by selective optimization).

color fidelity↗

Equity implications of net-zero emissions: A multi-model analysis of energy expenditures across income classes under economy-wide deep decarbonization policies

With companies, states, and countries targeting net-zero emissions around midcentury, there are questions about how these targets alter household welfare and finances, including distributional effects across income groups. This paper examines the distributional dimensions of technology transitions and net-zero policies with a focus on welfare impacts across household incomes. The analysis uses a model intercomparison with a range of energy-economy models using harmonized policy scenarios reaching economy-wide, net-zero CO 2 emissions across the United States in 2050. Here we employ a novel linking approach that connects output from detailed energy system models with survey microdata on energy expenditures across income classes to provide distributional analysis of net-zero policies. Although there are differences in model structure and input assumptions, we find broad agreement in qualitative trends in policy incidence and energy burdens across income groups. Models generally agree that direct energy expenditures for many households will likely decline over time with reference and net-zero policies. However, there is variation in the extent of changes relative to current levels, energy burdens relative to reference levels, and electricity expenditures. Policy design, primarily how climate policy revenues are used, has first-order impacts on distributional outcomes. Net-zero policy costs, in both absolute and relative terms, are unevenly distributed across households, and relative increases in energy expenditures are higher for lowest-income households. However, we also find that recycled revenues from climate policies have countervailing effects when rebated on a per-capita basis, offsetting higher energy burdens and potentially even leading to net progressive outcomes. Model results also show carbon Laffer curves, where revenues from net-zero policies increase but then decline with higher stringencies, which can diminish the progressive effects of climate policies. We also illustrate how using annual income deciles for distributional analysis instead of expenditure deciles can overstate the progressivity of emissions policies by overweighting revenue impacts on the lowest-income deciles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Machine learning for endoleak detection after endovascular aortic repair

Diagnosis of endoleak following endovascular aortic repair (EVAR) relies on manual review of multi-slice CT angiography (CTA) by physicians which is a tedious and time-consuming process that is susceptible to error. We evaluate the use of a deep neural network for the detection of endoleak on CTA for post-EVAR patients using a novel data efficient training approach. 50 CTAs and 20 CTAs with and without endoleak respectively were identified based on gold standard interpretation by a cardiovascular subspecialty radiologist. The Endoleak Augmentor, a custom designed augmentation method, provided robust training for the machine learning (ML) model. Predicted segmentation maps underwent post-processing to determine the presence of endoleak. The model was tested against 3 blinded general radiologists and 1 blinded subspecialist using a held-out subset (10 positive endoleak CTAs, 10 control CTAs). Model accuracy, precision and recall for endoleak diagnosis were 95%, 90% and 100% relative to reference subspecialist interpretation (AUC = 0.99). Accuracy, precision and recall was 70/70/70% for generalist1, 50/50/90% for generalist2, and 90/83/100% for generalist3. The blinded subspecialist had concordant interpretations for all test cases compared with the reference. In conclusion, our ML-based approach has similar performance for endoleak diagnosis relative to subspecialists and superior performance compared with generalists.

60 APPLIED LIFE SCIENCES↗

Solid-state dosimeters: A new approach for mammography measurements

Purpose: To compare responses of modern commercially available solid-state dosimeters (SStDs) used in mammography medical physics surveys for two major vendors of current digital mammography units. To compare differences in dose estimates among SStD responses with ionization chamber (IC) measurements for several target/filter (TF) combinations and report their characteristics. To review scientific bases for measurements of quantities required for mammography for traditional measurement procedures and SStDs. Methods: SStDs designed for use with modern digital mammography units were acquired for evaluation from four manufacturers. Each instrument was evaluated under similar conditions with the available mammography beams provided by two modern full-field digital mammography units in clinical use: a GE Healthcare Senographe Essential (Essential) and a Hologic Selenia Dimensions 5000 (Dimensions), with TFs of Mo/Mo, Mo/Rh; and Rh/Rh and W/Rh, W/Ag, and W/Al, respectively. Measurements were compared among the instruments for the TFs over their respective clinical ranges of peak tube potentials for kVp and half-value layer (HVL) measurements. Comparisons for air kerma (AK) and their associated relative calculated average glandular doses (AGDs), i.e., using fixed mAs, were evaluated over the limited range of 28–30 kVp. Measurements were compared with reference IC measurements for AK, reference HVLs and calculated AGD, for two compression paddle heights for AK, to evaluate scatter effects from compression paddles. SStDs may require different positioning from current mammography measurement protocols. Results: Measurements of kVp were accurate in general for the SStDs (within −1.2 and +1.1 kVp) for all instruments over a wide range of set kVp’s and TFs and most accurate for Mo/Mo and W/Rh. Discrepancies between measurements and reference values were greater for HVL and AK. Measured HVL values differed from reference values by −6.5% to +3.5% depending on the SStD and TF. AK measurements over limited (28–30) kVp’s ranged from −6% to +7% for SStDs, compared with IC reference values. Relative AGDs for each SStD using its associated measurements of kVp, HVL and AK underestimated AGD in nearly all cases, compared with reference IC values, with discrepancies of <−1% to ∼−10%. Some differences in AGD were related to differences in contributions of compression paddle scatter to AK measurements made by ICs. Applying measured factors for scatter effects in AK measurements for three SStDs reduced discrepancies between −6.2% and +1.3%, shifting AGDs from SStDs closer to IC AGDs. Conclusions: This study revealed that SStD measurements yielded good agreement with set kVp, poor agreement with standard HVL determinations, and AK measurements that were substantially different from IC measurements. Discrepancies are partly related to the scattered radiation measured by ICs in determining AK. As a result, IC measurements required for AGD, using currently accepted methodology, typically result in higher AGDs than SStDs, because current methodologies do not account for differing instrument responses to scatter. HVLs reported by SStDs contribute to discrepancies in calculated AGD that depend on kVp and TF. Medical physicists are encouraged to compare their results for SStD instruments using a similar methodology for potential discrepancies with their traditional instruments.

60 APPLIED LIFE SCIENCES↗

Characterization of calibration curves and energy dependence GafChromic{sup TM} XR-QA2 model based radiochromic film dosimetry system

Purpose: The authors investigated the energy response of XR-QA2 GafChromic{sup TM} film over a broad energy range used in diagnostic radiology examinations. The authors also made an assessment of the most suitable functions for both reference and relative dose measurements. Methods: Pieces of XR-QA2 film were irradiated to nine different values of air kerma in air, following reference calibration of a number of beam qualities ranging in HVLs from 0.16 to 8.25 mm Al, which corresponds to effective energy range from 12.7 keV to 56.3 keV. For each beam quality, the authors tested three functional forms (rational, linear exponential, and power) to assess the most suitable function by fitting the delivered air kerma in air as a function of film response in terms of reflectance change. The authors also introduced and tested a new parameterχ = netΔR·e{sup m} {sup netΔR} that linearizes the inherently nonlinear response of the film. Results: The authors have found that in the energy range investigated, the response of the XR-QA2 based radiochromic film dosimetry system ranges from 0.222 to 0.420 in terms of netΔR at K{sub air}{sup air} = 8 cGy. For beam qualities commonly used in CT scanners (4.03–8.25 mm Al), the variation in film response (netΔR at K{sub air}{sup air} = 8 cGy) amounts to ± 5%, while variation in K{sub air}{sup air} amounts to ± 14%. Conclusions: Results of our investigation revealed that the use of XR-QA2 GafChromic{sup TM} film is accompanied by a rather pronounced energy dependent response for beam qualities used for x-ray based diagnostic imaging purposes. The authors also found that the most appropriate function for the reference radiochromic film dosimetry would be the power function, while for the relative dosimetry one may use the exponential response function that can be easily linearized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Lower Columbia River and Estuary Restoration Reference Site Study. 2010 Final Report and Site Summaries

This report summarizes data collected from 2007 - 2010 from 43 wetland sites in the lower Columbia River and estuary (LCRE) considered to represent “reference” or relatively undisturbed conditions. The purpose of this study was to provide data from a suite of reference wetlands that would serve as a baseline of wetland conditions, reduce uncertainties regarding the factors controlling these wetlands, provide data to inform restoration design, and enable the evaluation of restoration action effectiveness monitoring. Methods are provided for all data collection efforts and data analysis. The results are detailed in individual Site Summaries, where data on all monitored metrics are provided in tables and graphs. Preliminary conclusions and are set forth as are recommendations for further analysis and management applications of this dataset.

54 ENVIRONMENTAL SCIENCES↗

New SCALE Sensitivity/Uncertainty Capabilities Applied to Bias Estimation and to Design of MIRTE Reference Experiments

New TSUNAMI tools of SCALE 6, TSURFER and TSAR, are demonstrated to examine the bias effects of small-worth test materials, relative to reference experiments. TSURFER is a data adjustment bias and bias uncertainty assessment tool, and TSAR computes the sensitivity of the change in reactivity between two systems to the cross-section data common to their calculation. With TSURFER, it is possible to examine biases and bias uncertainties in fine detail. For replacement experiments, the application of TSAR to TSUNAMI-3D sensitivity data for pairs of experiments allows the isolation of sources of bias that could otherwise be obscured by materials with more worth in an individual experiment. The application of TSUNAMI techniques in the design of nine reference experiments for the MIRTE program will allow application of these advanced techniques to data acquired in the experimental series. The validation of all materials in a complex criticality safety application likely requires consolidating information from many different critical experiments. For certain materials, such as structural materials or fission products, only a limited number of critical experiments are available, and the fuel and moderator compositions of the experiments may differ significantly from those of the application. In these cases, it is desirable to extract the computational bias of a specific material from an integral keff measurement and use that information to quantify the bias due to the use of the same material in the application system. Traditional parametric and nonparametric methods are likely to prove poorly suited for such a consolidation of specific data components from a diverse set of experiments. An alternative choice for consolidating specific data from numerous sources is a data adjustment tool, like the ORNL tool TSURFER (Tool for Sensitivity/Uncertainty analysis of Response Functionals using Experimental Results) from SCALE 6.1 However, even with TSURFER, it may be difficult to examine a single experiment and differentiate bias due to a test material from bias due to other materials such as fuel and moderator. An alternative method is to perform two experiments on the same critical assembly, one with and one without the test material, and examine differences in the biases due to the introduction of the test material. Techniques to extract a computational bias from pairs of replacement experiments and project that bias, with an associated bias uncertainty, to an application system are described herein.

36 MATERIALS SCIENCE↗

Tools for Performing SBG hyperspectral Observing System Simulation Experiment

One of NASA’s Decadal Survey mission, Surface Biology and Geology (SBG), will include a hyperspectral remote sensing imager, which has a very high spatial resolution and a wide spectral coverage (from UV to Near IR). Unprecedented large data volumes will be generated by the SBG hyperspectral instrument. Before the launch of the new satellite, an Observing System Simulation Experiment (OSSE) can be used to study different designs of the new satellite system. One of the key components in an OSSE study is a radiative transfer model (RTM) or forward model. In this presentation, we will describe a Principal Component-based Radiative Transfer Model (PCRTM) which is capable of simulating atmospheric (TOA) radiance or reflectance spectra from far IR to visible and UV spectral regions (50 wavenumber to 30000 wavenumber) quickly and accurately. Multiple scattering from multiple layers of clouds/aerosols are included in the model. The PCRTM has a very good accuracy relative to reference line-by-line radiative transfer models (LBLRTM), and it saves 3-4 orders of magnitude computational time relative to LBLRTM or MODTRAN. The PCRTM model has been successfully used to analyze large volumes of data from hyperspectral sensors such as AIRS, CrIS, and IASI. It has also been used to perform OSSE studies for the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission. Another useful tool for the OSSE is surface Bidirectional Reflectance Distribution Function (BRDF) database. It is very crucial for the SBG OSSE to include realistic BRDF spectra. Currently, most of the surface reflectance spectra such as those in the ECOSIS and ECOSTRESS are measured at specific observation geometries. We have developed a hyperspectral bidirectional reflectance (HSBR) model which combines Ross-Li BRDF model with the existing reflectance spectral libraries using a principal component analysis. This HSBR model can provide realistic BRDF spectra under various observation conditions. It can also be used to generate realistic BRDF spectra using measurements from multi-band imagers or spectrometers such as MODIS or VIIRS.

Xu Liu↗

Duality relation between radiation thermodynamics and cosmic string loop thermodynamics

We discuss thermodynamics of electromagnetic radiation, with p=(1/3){rho} and S{proportional_to}T{sup 3}V, and of cosmic string loops, with p=-(1/3){rho} and S{proportional_to}T{sup -3}V, where p stands for pressure, T temperature, {rho} energy density, S entropy, and V volume. We write the thermodynamic formalisms under a common framework that illustrates their formal relationship and allows us to go from one to the other through a smooth transformation. From a microscopic perspective, these relations arise from the energy relations u({lambda})=hc/{lambda} for the photons of electromagnetic radiation, and u(l)=(c{sup 4}/a{sup 2}G)l for cosmic string loops, a being a numerical (dimensionless) constant and {lambda} and l the radiation wavelength and the length of a loop; G, c, and h are the gravitational constant, the speed of light in vacuo, and the Planck constant, respectively. The corresponding thermodynamic behaviors are seen to be connected through a related thermal duality corresponding to the change of T by T*=T{sub c}{sup 2}/T, with T{sub c} a reference temperature related to h, c, and G.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients with brain tumors.

60 APPLIED LIFE SCIENCES↗

Survey of the Physical and Environmental Parameters of the Moon

This document presents, in summary, a compilation of the physical and environmental parameters of the moon. A determined attempt has been made to be objective at all times. Many of the physical sciences are presented in sufficient depth to adequately identify the basic information available. It is expected that the appropriate references will be consulted when additional detail is required. It is obvious both from the text and the reference material that divergent opinions prevail and uncertainties exist in almost every phase of lunar science; e.g., the existence of the lunar bulge, the thickness of the dust layer, etc. No pretense is made to resolve these differences, but by bringing together many references, it is hoped that some contribution will be made in lunar science. The subject index will be of particular value since it relates the reference section by subject. A glossary of terms used throughout the text is also provided.

Niedz, F. J.↗

Preliminary Results of the 1.5% TCA (Modular) Controls Model in the NASA Langley UPWT

To summarize the significant highlights in this report: (1) Data quality, determined by multiple repeat runs performed on the TCA baseline configuration, and long-term repeatability, determined by comparing baseline Reference H data from this test to a previous test, have been shown to be good. (2) The longitudinal stability of the TCA is more non-linear than for the Reference H, and while it is similar at normal lift values, the TCA has considerably more pitch-up at higher lift. (3) Longitudinal control effectiveness of the TCA is similar to the Reference H and the ratio of elevator effectiveness to horizontal tail effectiveness is approximately 0.3. (4) The directional stability of the TCA is improved relative to Reference H at higher angles-of attack. The chine is effective for improving directional stability.

Kubiatko, Paul↗

Configurational-Bias Monte Carlo Back-Mapping Algorithm for Efficient and Rapid Conversion of Coarse-Grained Water Structures into Atomistic Models

Coarse-grained molecular dynamics (MD) simulations represent a powerful approach to simulate longer time scale and larger length scale phenomena than those accessible to all-atom models. The gain in efficiency, however, comes at the cost of atomistic details. The reverse transformation, also known as back-mapping, of coarse grained beads into their atomistic constituents represents a major challenge. Most existing approaches are limited to specific molecules or specific force-fields and often rely on running a long time atomistic MD of the back-mapped configuration to arrive at an optimal solution. Such approaches are problematic when dealing with systems with high diffusion barriers. Here, we introduce a new extension of the configurational-bias-Monte-Carlo (CBMC) algorithm, which we term the crystalline-configurational-bias-Monte-Carlo (C-CBMC) algortihm, that allows rapid and efficient conversion of a coarse-grained model back into its atomistic representation. Although the method is generic, we use a coarse-grained water model as a representative example and demonstrate the back-mapping or reverse transformation for model systems ranging from the ice-liquid water interface to amorphous and crystalline ice configurations. A series of simulations using the TIP4P/Ice model are performed to compare the new CBMC method to several other standard Monte Carlo and Molecular Dynamics based back-mapping techniques. In all the cases, the C-CBMC algorithm is able to find optimal hydrogen bonded configuration many thousand evaluations/steps sooner than the other methods compared within this paper. For crystalline ice structures such as a hexagonal, cubic, and cubic-hexagonal stacking disorder structures, the C-CBMC was able to find structures that were between 0.05 and 0.1 eV/water molecule lower in energy than the ground state energies predicted by the other methods. Detailed analysis of the atomistic structures show a significantly better global hydrogen positioning when contrasted with the existing simpler back-mapping methods. The error in the RDFs of backmapped relative to reference configuration for the CCBMC, MD, and MC were found to be 6.9, 8.7, and 12.9 respectively for the hexagonal system. For the cubic system the relative error of the RDFs for the CCBMC, MD, and MC were found to be 18.2, 34.6, and 39.0 respectively. Finally, our results demonstrate the efficiency and efficacy of our new back-mapping approach, especially for crystalline systems where simple force-field based relaxations have a tendency to get trapped in local minima.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observations of an interplanetary intermediate shock associated with a magnetic reconnection exhaust

Two intermediate shocks (ISs) in interplanetary space have been identified via one spacecraft observation. However, Feng et al. suggested that the analysis using a single spacecraft observation based only on the Rankine–Hugoniot (R-H) relations could misinterpret a tangential discontinuity (TD) as an IS. The misinterpretation can be fixed if two spacecraft observations are available. In this paper, we report an IS-like discontinuity associated with a magnetic reconnection exhaust, which was observed by Wind on 2000 August 9 at 1 au. We investigated this discontinuity by fitting the R-H relations and referring to the Advanced Composition Explorer (ACE) observations. As a result, we found that the observed magnetic field and plasma data satisfy the R-H relations well, and the discontinuity satisfies all the requirements of the 2→3 type IS. Although the discontinuity cannot be identified strictly by using two spacecraft observations, in light of the ACE observations we consider that the discontinuity should be an IS rather than a TD.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy: An annotated bibliography

This bibliography is a compilation of approximately 4,300 selected references on energy and energy related topics. The references are arranged by date, with the latest works first, in the following subject categories: (1) energy and power - general; resources, supply/demand, and forecasting; policy, legislation, and regulation; research and development; environment; consumption and economics; and conservation, (2) energy and power sources - general, fossil fuels, hydrogen and methanol, organic wastes and waste heat, nuclear, geothermal, solar, wind, ocean/water, magnetohydrodynamics and electrohydrodynamics, and gas and steam turbines, and (3) energy and power storage and transmission. Literature from bibliographic sources dated January 1972 through July 1974 is covered, with some pertinent literature prior to 1972 included.

Blow, S. J.↗

The correction for spectral mismatch effects on the calibration of a solar cell when using a solar simulator

A general expression was derived to enable calculation of the calibration error. The information required includes the relative spectral response of the reference cell, the relative spectral response of the cell under test, and the relative spectral irradiance of the simulator (over the spectral range defined by cell response). The spectral irradiance of the solar AMX is assumed to be known.

Seaman, C. H.↗