Search NASA⌕ Search

SEARCH · Search NASA

Results for “Relative positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Video Guidance Sensor: Space, Earth, Ground, and Sea

Engineers at the Marshall Space Flight Center (MSFC) have been developing and testing video-based sensors for automated spacecraft guidance for several years. The next generation of Video Guidance Sensor (VGS) is being designed to be faster and more capable than ever. It will have applications to relative position measurement in any field of endeavor. The system works by sequentially firing two different wavelengths of laser diodes at the target (which has retroreflectors) and processing the two images. Since the target only reflects one wavelength, it shows up well in one image and not at all in the other. Because the target's dimensions are known, the relative positions and attitudes of the target and the sensor can be computed from the spots reflected from the target. The current sensor operates at 5 Hz at ranges from 1 to 110 meters with a 20 deg. field-of-view. The Video Guidance Sensor (VGS) developed over the past several years has performed well in testing and met the objective of being used as the terminal guidance sensor for an automated rendezvous and capture system. The first VGS was successfully tested in closed-loop 3-degree-of-freedom (3-DOF) tests in 1989 and then in 6-DOF open-loop tests in 1992 and closed-loop tests in 1993-4. Development and testing continued, and in 1995 approval was given to test the VGS in an experiment on the Space Shuttle. The VGS flew in 1997 and in 1998, performing well during both flight experiments. During the development and testing before, during, and after the flight experiments, numerous areas for improvement were found. The next generation of VGS is being designed to operate at up to 100 Hz tracking rates and at ranges from 0.5 to 200 meters. In addition to its use as a spacecraft guidance sensor, it could be used as an alignment aid for an operator of a remote system (giving position and attitude feedback data), as a feedback system for a robotic arm, or for automated vehicle guidance. The next generation VGS, with its higher tracking rates, smaller size, and lower power could be used in more places than the original VGS, and by using LED's instead of laser diodes, the system would be eye-safe at any range. More potential applications include aerial station keeping (keeping 2 or more autonomous aircraft within particular relative positions), under-water robotics, and the guidance of ground vehicles in predefined areas equipped with sets of targets.

Howard, Richard T.↗

Selective Herbivory by an Invasive Cyprinid, the Rudd Scardinius erythrophthalmus

1. Herbivory by non-native animals is a problem of growing concern globally, especially for ecosystems where significant native herbivores did not previously exist or have been replaced by non-natives. The rudd (Scardinius erythrophthalmus) is an omnivorous cyprinid that has a nearly global longitudinal distribution due to human translocations, yet it is unknown whether the rudd feeds selectively among aquatic macrophyte species common to North American waters. 2. We tested a null hypothesis of non-selective feeding by rudds using five species of aquatic macrophytes: Ceratophyllum demersum, Elodea canadensis, Najas flexilis, Stuckenia pectinata, and Vallisneria americana. Four rudds were placed in 15 different 890-L tanks and presented with known quantities of each macrophyte species (each tank serving as a block in a randomized complete block design). Each macrophyte bundle was weighed on six dates during a 13 d experiment. Differences in mean percent weight remaining among macrophyte species were tested using repeated measures analysis of variance. We also quantified differences among chemical attributes of the five macrophyte species and qualitatively determined if selective feeding by rudds was related to dry matter content (DMC), percent C by dry weight (%C), percent N by dry weight (%N), and the concentrations of total soluble proteins, two organic acids (aconitic and oxalic acid), total soluble phenolic compounds (<1,000 Da), nine soluble phenolic metabolites, and total phenolic compounds. 3. Selective feeding by rudds was evident, with the order of macrophyte removal (from highest to lowest) being: N. flexilis > E. canadensis > S. pectinata > V. americana > C. demersum. Selection was positively related to %C and atomic C:N, but not DMC, %N, or concentration of total soluble proteins, contrary to the expectation that rudds would select the most nutritious plants available. The concentration of aconitic acid was greatest in N. flexilis, a preferred macrophyte, contrary to the expectation that this compound provides resistance to herbivory. The concentration of oxalic acid, which negatively affects palatability, was highest in C. demersum, the least preferred macrophyte. Selection was also positively related to the concentration of total soluble phenolic compounds; however, examination of the influence of specific phenolic metabolites provided further insights. Concentrations of caffeic acid, trans-caftaric acid, and quercetin were positively related to macrophyte preference by rudds, whereas concentrations of cis-4-O- and trans-4-O-ferulic acid glucoside were negatively related. Patterns between the concentrations of p-coumaric acid, rosmarinic acid, and macrophyte preference by rudds were less obvious. 4. Our results suggest that selective feeding by rudds has the potential to alter macrophyte assemblages and jeopardize habitat restoration projects seeking to establish a diverse plant assemblage. Studies of selective herbivory by various aquatic taxa have provided evidence that selection is simultaneously influenced by multiple plant characteristics, including nutritional quality, morphology, rigidity, and chemical defenses. Future research designed to elucidate the mechanisms by which specific chemical attributes of macrophytes influence selective herbivory by rudds and other taxa will help provide an understanding of how herbivores have changed macrophyte assemblages and make predictions about how macrophyte assemblages will be altered following biological invasions.

Kapuscinski, Kevin L↗

The effect of anxiety on sleep disorders in medical students: a moderated mediation model

The relationship between anxiety and sleep disorders is a key research topic in the academic community. However, evidence on the mechanism through which anxiety influences sleep disorders remains limited. The purpose of this study was to investigate the roles of flourishing and neuroticism in the mechanism through which anxiety influences sleep disorders in medical students. We constructed a moderated mediation model and tested the mediating role of flourishing and the moderating role of neuroticism in medical college students. The results showed that: (1) anxiety was significantly and positively related to sleep disorders and significantly and negatively related to flourishing; flourishing was significantly and negatively related to sleep disorders; neuroticism was significantly and positively related to sleep disorders; (2) flourishing had a mediation effect on the relationship between anxiety and sleep disorders; (3) neuroticism moderated the process through which flourishing mediated the effect of anxiety on sleep disorders. Our research expands the literature on the mechanism underlying the effects of anxiety on sleep disorders and provides insights into the potential prevention and intervention of sleep and emotional problems in medical students.

Yu, Chuang↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

Automation of the targeting and reflective alignment concept

The automated alignment system, described herein, employs a reflective, passive (requiring no power) target and includes a PC-based imaging system and one camera mounted on a six degree of freedom robot manipulator. The system detects and corrects for manipulator misalignment in three translational and three rotational directions by employing the Targeting and Reflective Alignment Concept (TRAC), which simplifies alignment by decoupling translational and rotational alignment control. The concept uses information on the camera and the target's relative position based on video feedback from the camera. These relative positions are converted into alignment errors and minimized by motions of the robot. The system is robust to exogenous lighting by virtue of a subtraction algorithm which enables the camera to only see the target. These capabilities are realized with relatively minimal complexity and expense.

Redfield, Robin C.↗

GPS inferred geocentric reference frame for satellite positioning and navigation

Accurate geocentric three-dimensional positioning is of great importance for various geodetic and oceanographic applications. While relative positioning accuracy of a few centimeters has become a reality using Very Long Baseline Interferometry (VLBI), the uncertainty in the offset of the adopted coordinate system origin from the geocenter is still believed to be of the order of one meter. Satellite Laser Ranging (SLR) is capable of determining this offset to better than 10 cm, though, because of the limited number of satellites, this requires a long arc of data. The Global Positioning System (GPS) measurements provide a powerful alternative for an accurate determination of this origin offset in relatively short period of time. Two strategies are discussed, the first utilizes the precise relative positions predetermined by VLBI, whereas the second establishes a reference frame by holding only one of the tracking sites longitude fixed. Covariance analysis studies indicate that geocentric positioning to an accuracy of a few centimeters can be achieved with just one day of precise GPS pseudorange and carrier phase data.

Malla, Rajendra P.↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Problems associated with reaction mass actuators used in conjunction with LQG control on the Mini-Mast

The work being done at NASA LaRC on developing control laws for the Mini-Mast experimental facility is reviewed with particular attention given to the problems associated with the stroke limit of the reaction mass actuators used in conjunction with the LQG control. An algorithm for converting the force commands of the LQG algorithm into position command for the reaction mass devices is described. It is shown that the position command can be used as an input to a local controller so that the relative position of the reaction mass would track the commanded relative position. The stabilization of the integration scheme makes it possible to avoid the position drift arising in the direct double integration method of converting force commands to position commands.

Ghosh, D.↗

Application of the nonlinear vortex-lattice concept to aircraft-interference problems

A discrete-vortex model was developed to account for the hazardous effects of the vortex trail issued from the edges of separation of a large leading wing on a small trailing wing. The model is divided into three main parts: the leading wing and its near wake, the near and far wakes of the leading wing, and the trailing wing and the portion of the far wake in its vicinity. The normal force, pitching moment, and rolling moment coefficients for the trailing wing are calculated. The circulation distribution in the vortex trail is calculated in the first part of the model where the leading wing is far upstream and hence is considered isolated. A numerical example is solved to demonstrate the feasibility of using this method to study interference between aircraft. The numerical results show the correct trends: The following wing experiences a loss in lift between the wing-tip vortex systems of the leading wing, a gain outside this region, and strong rolling moments which can change sign as the lateral relative position changes. All the results are strongly dependent on the vertical relative position.

Kandil, O. A.↗

Feasibility of “Weak GPS” Real-Time Positioning/Timing at Lunar Distance

There are multiple Global Navigation Satellite Systems (GNSS’s), comprising over 100 navigation satellites in the Earth’s medium and high orbits. Most of these satellites have antennas that point Nadir to earth, and transmit navigation signals so vehicles on Earth’s surface and in its vicinity can perform trilateration and estimate its 3-dimenional (3D) positioning. The sidelobes of these antennas can occasionally point to the Moon. It is postulated that a lunar vehicle carrying a large enough receiving antenna can occasionally detects and receives four or more sidelobes of these weak GNSS signals, thus enabling the vehicle to perform 3D positioning using an onboard GNSS receiver. We propagate the orbits of the GNSS satellites from United States’ Global Positioning Satellite (GPS) constellation, the Europe’s Galileo constellation, and the Russia’s GLONASS constellation, a total of 81 satellites. We simulate the visibility of these satellites by a lunar vehicle in a Near Rectilinear Halo Orbit (NRHO), based on the assumption that the lunar vehicle is “in-view” of a GNSS satellite as long as it falls within the 40- degree beam-width of the satellite. We also simulate the 3D positioning performance as a function of satellites’ ephemeris errors and pseudo-range errors. The preliminary results show that the lunar vehicle can “see” 5 – 13 satellites, and achieve a 3D positioning error (one-sigma) of 200 – 300 meters based on reasonable ephemeris and pseudo- range error assumptions. We also consider the case of using relative positioning to mitigate the GNSS satellites’ ephemeris biases. That is, by assuming a reference receiver with accurately known positioning that is close to the lunar vehicle, and computing the relative position of the lunar vehicle relative to the reference.

Cheung, Kar-Ming↗

CATALOG MATCHING WITH ASTROMETRIC CORRECTION AND ITS APPLICATION TO THE HUBBLE LEGACY ARCHIVE

Object cross-identification in multiple observations is often complicated by the uncertainties in their astrometric calibration. Due to the lack of standard reference objects, an image with a small field of view can have significantly larger errors in its absolute positioning than the relative precision of the detected sources within. We present a new general solution for the relative astrometry that quickly refines the World Coordinate System of overlapping fields. The efficiency is obtained through the use of infinitesimal three-dimensional rotations on the celestial sphere, which do not involve trigonometric functions. They also enable an analytic solution to an important step in making the astrometric corrections. In cases with many overlapping images, the correct identification of detections that match together across different images is difficult to determine. We describe a new greedy Bayesian approach for selecting the best object matches across a large number of overlapping images. The methods are developed and demonstrated on the Hubble Legacy Archive, one of the most challenging data sets today. We describe a novel catalog compiled from many Hubble Space Telescope observations, where the detections are combined into a searchable collection of matches that link the individual detections. The matches provide descriptions of astronomical objects involving multiple wavelengths and epochs. High relative positional accuracy of objects is achieved across the Hubble images, often sub-pixel precision in the order of just a few milliarcseconds. The result is a reliable set of high-quality associations that are publicly available online.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaling mercury biodynamics from individuals to populations: Implications of an herbivorous fish on mercury cycles in streams

Mercury (Hg) is a widespread environmental pollutant anthropogenically released into aquatic ecosystems where it is tightly retained and cycled through a combination of abiotic and biotic processes. The organic form of Hg, Methylmercury (MeHg), binds to organic carbon chains and efficiently bioaccumulates through aquatic food webs to toxic levels in consumers. For these reasons, understanding the transport and fate of mercury, including the role of organisms in these cycles, is important. The premise of the Somatic Growth Dilution (SGD) concept is that bioaccumulation of contaminants will become more dilute within an organism as it displays higher growth efficiency. While multiple studies have substantiated the effects of SGD on reduced MeHg concentrations at the individual level, the implications of SGD to populations and overall food web dynamics is uncertain. Herein, we examined the influence of SGD on total MeHg standing stock and flux in stoneroller ( Campostoma oligolepis ) populations at five sites in East Fork Poplar Creek (EFPC), a stream contaminated by Hg on the Oak Ridge Reservation. We assessed patterns in periphyton and stoneroller MeHg concentrations in relation to relative growth and population density to determine evidence of SGD and density-dependent growth, respectively. We then calibrated a biodynamic model relating MeHg concentration in stonerollers to growth rate, assimilation efficiency, uptake, and elimination of MeHg. Using over 30 years of population data, individual biodynamic models were scaled to the population level to analyze the effects of population density and growth on MeHg standing stock (ug m -2 ) in stoneroller populations and flux (ug m -2 d -1 ) from periphyton communities to stonerollers. We found evidence of both density-dependent and “boom-and-bust” growth patterns for stonerollers in EFPC. In congruence with the SGD concept, sites with higher average relative growth had lower MeHg concentrations. However, total MeHg standing stock and flux was strongly related to population density, irrespective of changing growth patterns. Additionally, higher relative growth was positively related to a higher total MeHg flux. However, the implications of growth on the transfer of MeHg in food webs is complicated and dependent upon population size, age structure, and growth-at-age. Our results also suggest that stonerollers may play significant roles in contaminant cycles in EFPC by mobilizing considerable quantities of Hg, storing significant reservoirs of hg and MeHg, and transferring MeHg to higher trophic levels.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-61: Monitoring Tumor Motion in Real-Time with EPID Imaging During Cervical Cancer Treatment

Purpose: Traditional external beam radiotherapy for cervical cancer requires setup by external skin marks. In order to improve treatment accuracy and reduce planning margin for more conformal therapy, it is essential to monitor tumor positions interfractionally and intrafractionally. We demonstrate feasibility of monitoring cervical tumor motion online using EPID imaging from Beam’s Eye View. Methods: Prior to treatment, 1∼2 cylindrical radio opaque markers were implanted into inferior aspect of cervix tumor. During external beam treatments on a Varian 2100C by 4-field 3D plans, treatment beam images were acquired continuously by an EPID. A Matlab program was developed to locate internal markers on MV images. Based on 2D marker positions obtained from different treatment fields, their 3D positions were estimated for every treatment fraction. Results: There were 398 images acquired during different treatment fractions of three cervical cancer patients. Markers were successfully located on every frame of image at an analysis speed of about 1 second per frame. Intrafraction motions were evaluated by comparing marker positions relative to the position on the first frame of image. The maximum intrafraction motion of the markers was 1.6 mm. Interfraction motions were evaluated by comparing 3D marker positions at different treatment fractions. The maximum interfraction motion was up to 10 mm. Careful comparison found that this is due to patient positioning since the bony structures shifted with the markers. Conclusion: This method provides a cost-free and simple solution for online tumor tracking for cervical cancer treatment since it is feasible to acquire and export EPID images with fast analysis in real time. This method does not need any extra equipment or deliver extra dose to patients. The online tumor motion information will be very useful to reduce planning margins and improve treatment accuracy, which is particularly important for SBRT treatment with long delivery time.

60 APPLIED LIFE SCIENCES↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Structural Basis of the CD8[alpha beta]/MHC Class I Interaction: Focused Recognition Orients CD8[beta] to a T Cell Proximal Position[superscript 1,2]

In the immune system, B cells, dendritic cells, NK cells, and T lymphocytes all respond to signals received via ligand binding to receptors and coreceptors. Although the specificity of T cell recognition is determined by the interaction of T cell receptors with MHC/peptide complexes, the development of T cells in the thymus and their sensitivity to Ag are also dependent on coreceptor molecules CD8 (for MHC class I (MHCI)) and CD4 (for MHCII). The CD8{alpha}{beta} heterodimer is a potent coreceptor for T cell activation, but efforts to understand its function fully have been hampered by ignorance of the structural details of its interactions with MHCI. In this study we describe the structure of CD8{alpha}{beta} in complex with the murine MHCI molecule H-2D{sup d} at 2.6 {angstrom} resolution. The focus of the CD8{alpha}{beta} interaction is the acidic loop (residues 222-228) of the {alpha}3 domain of H-2D{sup d}. The {beta} subunit occupies a T cell membrane proximal position, defining the relative positions of the CD8{alpha} and CD8{beta} subunits. Unlike the CD8{alpha}{alpha} homodimer, CD8{alpha}{beta} does not contact the MHCI {alpha}{sub 2}- or {beta}{sub 2}-microglobulin domains. Movements of the CD8{alpha} CDR2 and CD8{beta} CDR1 and CDR2 loops as well as the flexibility of the H-2D{sup d} CD loop facilitate the monovalent interaction. The structure resolves inconclusive data on the topology of the CD8{alpha}{beta}/MHCI interaction, indicates that CD8{beta} is crucial in orienting the CD8{alpha}{beta} heterodimer, provides a framework for understanding the mechanistic role of CD8{alpha}{beta} in lymphoid cell signaling, and offers a tangible context for design of structurally altered coreceptors for tumor and viral immunotherapy.

60 APPLIED LIFE SCIENCES↗

Exocentric direction judgements in computer-generated displays and actual scenes

One of the most remarkable perceptual properties of common experience is that the perceived shapes of known objects are constant despite movements about them which transform their projections on the retina. This perceptual ability is one aspect of shape constancy (Thouless, 1931; Metzger, 1953; Borresen and Lichte, 1962). It requires that the viewer be able to sense and discount his or her relative position and orientation with respect to a viewed object. This discounting of relative position may be derived directly from the ranging information provided from stereopsis, from motion parallax, from vestibularly sensed rotation and translation, or from corollary information associated with voluntary movement. It is argued that: (1) errors in exocentric judgements of the azimuth of a target generated on an electronic perspective display are not viewpoint-independent, but are influenced by the specific geometry of their perspective projection; (2) elimination of binocular conflict by replacing electronic displays with actual scenes eliminates a previously reported equidistance tendency in azimuth error, but the viewpoint dependence remains; (3) the pattern of exocentrically judged azimuth error in real scenes viewed with a viewing direction depressed 22 deg and rotated + or - 22 deg with respect to a reference direction could not be explained by overestimation of the depression angle, i.e., a slant overestimation.

Ellis, Stephen R.↗