Reliability assessment testing of 2 kw hydrogen-oxygen fuel cell stacks.
Reliability assessment test program for determining capabilities and limitations of 2 kw hydrogen-oxygen fuel cell stacks
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Reliability assessment test program for determining capabilities and limitations of 2 kw hydrogen-oxygen fuel cell stacks
Increasing cybercrime rates means identifying potential victims is critically important. Social discounting tasks show that individuals share less personally identifying information as social distance increases. However, the test–retest reliability and uniqueness of this measure is unclear. The current study assessed social discounting for personally identifying information (SDPII), delay discounting, risk taking, and personality at two measurement waves 30 days apart for 64 undergraduate students. Test–retest reliability was statistically significant for the SDPII and all other measures, replicating previous studies. SDPII rates were not significantly correlated with other measures during both measurement waves, showing discriminant validity. SDPII rates were lower than those reported in a previous study but were still well described by a hyperbolic discounting function, suggesting replicability across studies. Furthermore, the high test–retest reliability, uniqueness, and replicability of the SDPII suggests that it may quantitatively identify cybercrime victimization. Future research should test which measure or combination of measures can accurately predict scam and cybercrime victimization to inform data-based interventions.
Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.
To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.
In this Phase I SBIR project, a “core-shell” composite cathode approach was evaluated for improving SOFC performance and reducing degradation of lanthanum strontium cobalt ferrite (LSCF) cathode materials, following previous successful demonstrations of infiltration approaches for achieving the same goals. The intent was to establish core-shell cathode powders that enabled high performance to be obtained with “drop-in” process capability for SOFC manufacturing (i.e., rather than adding an infiltration step to the SOFC manufacturing process). Milling, precipitation and hetero-coagulation methods were evaluated for making core-shell composite cathode powders comprised of coarse LSCF “core” particles and nanoscale “shell” particles of lanthanum strontium manganite (LSM) or praseodymium strontium manganite (PSM). Precipitation and hetero-coagulation methods were successful for obtaining the targeted core-shell morphology, although perfect coverage of the LSCF core particles by the LSM and PSM particles was not obtained. Electrochemical characterization of core-shell cathode powders and conventional (baseline) cathode powders was performed via electrochemical impedance spectroscopy (EIS) half-cell measurements and single-cell SOFC testing. Reliable EIS testing methods were established, which enabled comparative area-specific resistance measurements to be obtained. A single-cell SOFC testing approach also was established that enabled cathode resistance to be separated from overall cell resistance, and for cathode degradation to be separated from overall cell degradation. The results of these EIS and SOFC tests conclusively determined that the core-shell cathode powders resulted in significant lowering of performance, compared to the baseline cathodes. Based on the results of this project, it was concluded that the core-shell cathode approach did not warrant further investigation.
This project is a follow-on effort to the Joint Council on Aging AircraftJoint Group on Pollution Prevention (JCAAJG-PP) Pb-free Solder Project and NASA-DoD Lead-Free Electronics Project which were the first projects to test the reliability of Pb-free solder joints against the requirements of the aerospace and military community. This effort would continue to build on the results from the JCAAJG-PP Lead-Free Solder Project and NASA-DoD Lead-Free Electronics Project while focusing on a particular failure mechanism currently plaguing Pb-free assemblies, pad cratering.The NASA-DoD Lead-Free Electronics Project confirmed that pad cratering is one of the dominant failure modes that occur in various board level reliability tests, especially under dynamic loading. Pad Cratering is a latent defect that may occur during assembly, rework, and post assembly handling and testing.
Using polymer tantalum capacitors in Hi-Rel systems requires an assessment of the reliability characteristics of the parts. For this assessment, tantalum capacitors are typically subjected to reliability testing at temperatures and voltages exceeding their specified values, and the failure rate (FR) — or the probability of failure during use conditions — is calculated based on voltage and temperature acceleration factors. In this work, various types and lots of polymer tantalum capacitors have been tested at highly accelerated life test (HALT) conditions and the acceleration factors have been determined using different techniques. It has been shown that the behavior of capacitors under HALT conditions can be described based on the time-dependent dielectric breakdown (TDDB) model, which explains the presence of infant mortality (IM) and wear-out failures using the same failure mechanisms and allows for an assessment of the acceleration factors. The difference in acceleration factors obtained using exponential and power models is discussed. Analysis shows that with proper derating, screening, and qualification testing, the reliability of frameless Hi-Rel COTS polymer tantalum capacitors is adequate for space missions.
Using polymer tantalum capacitors in Hi-Rel systems requires an assessment of the reliability characteristics of the parts. For this assessment, tantalum capacitors are typically subjected to reliability testing at temperatures and voltages exceeding their specified values, and the failure rate (FR) — or the probability of failure during use conditions — is calculated based on voltage and temperature acceleration factors. In this work, various types and lots of polymer tantalum capacitors have been tested at highly accelerated life test (HALT) conditions and the acceleration factors have been determined using different techniques. It has been shown that the behavior of capacitors under HALT conditions can be described based on the time-dependent dielectric breakdown (TDDB) model, which explains the presence of infant mortality (IM) and wear-out failures using the same failure mechanisms and allows for an assessment of the acceleration factors. The difference in acceleration factors obtained using exponential and power models is discussed. Analysis shows that with proper derating, screening, and qualification testing, the reliability of frameless Hi-Rel COTS polymer tantalum capacitors is adequate for space missions.
NASA Goddard Space Flight Center (GSFC) is developing a master oscillator power amplifier (MOPA) laser transmitter for the Laser Interferometer Space Antenna (LISA) mission. The laser transmitter is one of the potential contributions to the LISA mission from NASA. Our development effort has included a master oscillator (MO), a power amplifier (PA), a frequency reference system (FRS), a power monitor detector (PMON), and laser electronics module (LEM). We are working on their design, performance evaluation, environmental testing, and reliability testing for space flight. We have built TRL 4 laser optical modules based on the MO and PA, which meets most performance requirements. One of the TRL 4 laser optical modules has been delivered to ESA for independent evaluation. TRL 6 versions of MO and PA are being built and evaluated at GSFC. TRL 5 and 6 versions of laser electronics are under development. In this paper, we will describe our progress to date and plans to demonstrate and deliver a TRL 6 laser demonstrator system to ESA by 2024.
Abstract. We test the reliability of two neural network interpretation techniques, backward optimization and layerwise relevance propagation, within geoscientific applications by applying them to a commonly studied geophysical phenomenon, the Madden–Julian oscillation. The Madden–Julian oscillation is a multi-scale pattern within the tropical atmosphere that has been extensively studied over the past decades, which makes it an ideal test case to ensure the interpretability methods can recover the current state of knowledge regarding its spatial structure. The neural networks can, indeed, reproduce the current state of knowledge and can also provide new insights into the seasonality of the Madden–Julian oscillation and its relationships with atmospheric state variables. The neural network identifies the phase of the Madden–Julian oscillation twice as accurately as a linear regression approach, which means that nonlinearities used by the neural network are important to the structure of the Madden–Julian oscillation. Interpretations of the neural network show that it accurately captures the spatial structures of the Madden–Julian oscillation, suggest that the nonlinearities of the Madden–Julian oscillation are manifested through the uniqueness of each event, and offer physically meaningful insights into its relationship with atmospheric state variables. We also use the interpretations to identify the seasonality of the Madden–Julian oscillation and find that the conventionally defined extended seasons should be shifted later by 1 month. More generally, this study suggests that neural networks can be reliably interpreted for geoscientific applications and may thereby serve as a dependable method for testing geoscientific hypotheses.
Digitalization of the instrumentation and control systems in nuclear power plant entails some new features which do not exist in analog systems. When the new features are applied in safety critical systems, the risk stemming from them should be quantified properly to assure the reliability of the entire power plant. Among the new features, software is considered as the most important factor because it can cause common cause failure to many redundant systems. Therefore, in this work, a test based reliability assessment method for a safety-critical software is developed. An output of a software is determined by not only inputs but also the internal state of the software at the time. In the case of safety critical software developed for usage in nuclear power plant, it is possible to directly investigate probable internal states thanks to detailed design specification and programing features, and the probable inputs also can be identified based on the physical linearity of each process parameter and hardware characteristics related to data acquisition. In this work, a development method for practical exhaustive test case consisting of investigation of internal state and probable input sets to a specific internal state are suggested. In addition to this, software logic simulator for execution of software logic test and the reliability quantification method based on the test result are developed. The feasibility of the suggested method is demonstrated via a case study. (authors)
OBJECTIVE: Task-related EEG is sensitive to changes in cognitive state produced by increased task difficulty and by transient impairment. If task-related EEG has high test-retest reliability, it could be used as part of a clinical test to assess changes in cognitive function. The aim of this study was to determine the reliability of the EEG recorded during the performance of a working memory (WM) task and a psychomotor vigilance task (PVT). METHODS: EEG was recorded while subjects rested quietly and while they performed the tasks. Within session (test-retest interval of approximately 1 h) and between session (test-retest interval of approximately 7 days) reliability was calculated for four EEG components: frontal midline theta at Fz, posterior theta at Pz, and slow and fast alpha at Pz. RESULTS: Task-related EEG was highly reliable within and between sessions (r0.9 for all components in WM task, and r0.8 for all components in the PVT). Resting EEG also showed high reliability, although the magnitude of the correlation was somewhat smaller than that of the task-related EEG (r0.7 for all 4 components). CONCLUSIONS: These results suggest that under appropriate conditions, task-related EEG has sufficient retest reliability for use in assessing clinical changes in cognitive status.
The Advanced Vehicle Testing and Evaluation (AVTE) project incorporated the conduct of advanced technology vehicle and infrastructure testing in the U.S. Department of Energy (DOE) Advanced Vehicle Testing Activity (AVTA). It was the only activity tasked by DOE to conduct independent field evaluations of vehicle technologies that use advanced technology systems and subsystems in vehicles that reduce petroleum consumption. The results are available through reports published on the AVTA website at http://avt.inl.gov/. The AVTE project provided insight into advanced vehicle technology's long-term performance, durability, maintenance, and lifecycle costs that cannot be found elsewhere. The site is a resource for DOE stakeholders and the public to gain knowledge on advanced technology vehicle progress and innovation. Vehicles tested included light and heavy-duty vehicles with conventional, hybrid, plug-in hybrid, and all-electric propulsion systems. Vehicles were tested on closed tracks and chassis dynamometers, as well as operated on public roads, in fleet operations, and over prescribed routes. All testing was controlled by procedures developed specifically to support such testing. Testing and evaluations were conducted in the following phases: Development and refinement of test procedures, which established testing procedures; Baseline performance testing, which established a performance baseline; Accelerated reliability testing, which determined vehicle reliability; Fleet testing, used to evaluate vehicle economics in fleet operation, and End of test performance evaluation. Test results from all aspects of testing were posted by Idaho National Laboratory (INL) to their website. This final report documents work conducted for the entirety of contract DE-EE0005501 by Intertek Testing Services NA, Inc. (Intertek). The contract was performed from October 1, 2011 through April 30, 2018, and includes 18 amendments to the original award with the most recent Amendment 18 dated March 28, 2018. The final budget for the AVTE project totaled 20,220,873 dollars. As a cooperative agreement, Intertek was obligated to provide cost share of 4,044,175 dollars, leaving 16,176,698 dollars as the Federal share of the agreement. Actual total expenditure for the AVTE project was 20,286,850 dollars. The full 16,176,698 dollars Federal share was expended and 4,110,152 dollars of cost share was provided by Intertek. This resulted in an over-share of 65,977 dollars. There were 106 light-duty on-road vehicles vehicles tested in both fleet and accelerated reliability testing. One additional vehicle was rented to obtain performance testing only. Three heavy-duty truck and trailer combinations were tested as part of the semi-autonomous driving with heavy-duty vehicles in a platoon. Overall project scope and direction was determined between Intertek, DOE, and technical teams from Idaho National Laboratory (INL), Argonne National Laboratory (ANL), and National Renewable Energy Laboratory (NREL). The project was administered by the DOE’s National Energy Technology Laboratory (NETL).
Long-term reliability is critical to the cost effectiveness and commercial success of photovoltaic (PV) products. Today most PV modules are warranted for 25 years, but there is no accepted test protocol to validate a 25-year lifetime. The qualification tests do an excellent job of identifying design, materials, and process flaws that are likely to lead to premature failure (infant mortality), butthey are not designed to test for wear-out mechanisms that limit lifetime. This paper presents a method for evaluating the ability of a new PV module technology to survive long-term exposure to specific stresses. The authors propose the use of baseline technologies with proven long-term field performance as controls in the accelerated stress tests. The performance of new-technology modules canthen be evaluated versus that of proven-technology modules. If the new-technology demonstrates equivalent or superior performance to the proven one, there is a high likelihood that they will survive versus the tested stress in the real world.
Reliable and secure time synchronization underpins the monitoring and control functions of modern power grids. As GPS-based timing infrastructures grow more susceptible to spoofing and jamming, their vulnerabilities pose escalating risks to grid stability. This work investigates a secure, resilient timing framework that can serve as an alternative or redundant source for power grids, with a particular focus on synchrophasorbased applications. A candidate timing system architecture is evaluated to guarantee trustworthy time dissemination, even in degraded conditions. A network hardware-in-the-loop testing of two synchrophasors validates the concepts, demonstrating enhanced timing integrity, improved detection of timing anomalies, and sustained observability during adverse timing events.
Capabilities of advanced material-testing techniques analyzed. Collection of four reports illustrates statistical method for characterizing flaw-detecting capabilities of sophisticated nondestructive evaluation (NDE). Method used to determine reliability of several state-of-the-art NDE techniques for detecting failure-causing flaws in advanced ceramic materials considered for use in automobiles, airplanes, and space vehicles.
This conference presentation analyzes early outdoor performance results from PVEL's DOE-funded bifacial study as well as indoor reliability test results for bifacial modules, including manufacturer-level comparisons across different albedos and times of day.
An outline is presented of issues raised in verifying the accuracy of reliability analysis tools. State-of-the-art reliability analysis tools implement various decomposition, aggregation, and estimation techniques to compute the reliability of a diversity of complex fault-tolerant computer systems. However, no formal methodology has been formulated for validating the reliability estimates produced by these tools. The author presents three states of testing that can be performed on most reliability analysis tools to effectively increase confidence in a tool. These testing stages were applied to the SURE (semi-Markov Unreliability Range Evaluator) reliability analysis tool, and the results of the testing are discussed.