SU-E-I-12: Characterization of Edge Effects in a Commercial Low-Dose Image Processing System

Purpose: Minimizing radiation dose while preserving image quality is critical in fluoroscopic imaging. One recent development is a noise reduction system (Allura Clarity) offered by Philips. Others have reported approximately 50% reduction in air kerma when using Clarity. These studies, however, provide only a cursory look at how the Clarity system affects image quality. The purpose of this work was to evaluate the effect of Clarity on the appearance of high-frequency image information. Methods: A lead attenuator with a smooth edge was imaged on two Philips Allura FD20 detectors: one with Clarity and one without. The edge was positioned in the center of the field of view and images were obtained under the following conditions: 40cm and 11cm fields of view, single shot and continuous fluoroscopy modes, and using abdomen and cardiac protocols, for a total of sixteen imaging conditions. Profiles were drawn perpendicular to the edge across 80% of its length, averaged to reduce noise, normalized to the maximum pixel value, and plotted as a function of distance. Results: For all single-shot acquisitions and most fluoroscopic images, overshoot of the edge was observed. This effect was more substantial for single-shot acquisitions (∼20%) than for fluoroscopic images (∼50%). For fluoroscopic acquisition, the overshoot decayed more quickly with the Clarity system. However, the system with Clarity introduced a ringing effect for both single-shot and fluoroscopic images that is not present on the non-Clarity system. Conclusion: Previous reports have demonstrated a substantial dose reduction when using Clarity but the impact this has on image appearance has not been characterized. One demonstrated difference is the change in appearance of high-frequency image information. It remains to be determined whether this effect may impact clinical images adversely.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peroxide Decomposer Module Catalyst Testing to Support Preparations for Increased Demand - 19052

The Hanford Site Effluent Treatment Facility's (ETF) mission is to receive, treat, and dispose of liquid effluents from on-site programs and projects. Its roles in the management and mitigation of tank waste volume is integral to the overall Hanford tank farms mission, as tank space is limited. ETF's role will become even more essential as the Direct-Feed Low Activity Waste process comes online at the Waste Treatment and Immobilization Plant (WTP). In order to accommodate the additional liquid effluent streams, the ETF will undergo a number of facility and equipment upgrades. Included in this is the reinstatement of the Peroxide Decomposer Module (PDM) into the ETF's main treatment train. The PDM is used to remove any residual hydrogen peroxide not fully consumed in the preceding ultraviolet/oxidation (UV/OX) treatment stage for organic destruction. Future waste stream estimates have been shown to contain organic content requiring excess hydrogen peroxide addition. Restoration of the PDM will ensure the ETF can accommodate the higher anticipated levels of organic content in these new influent streams. Due to low organic content levels in the current influents and some operability issues with the PDM, it has not been in operation since 1998. One aspect of the repair and upgrade of the PDM is the usability of manganese dioxide on alumina catalyst, Sud-Chemie T-2525, which was purchased in 2008 but has remained in storage since. The manufacturer of the catalyst states there is no known shelf life for the product and no current data to indicate the catalyst's performance after long-term storage. To determine the usability of the stored catalyst, a laboratory test was developed. The testing of this stored catalyst was based on testing methods and information collected from initial catalyst product testing performed in 2008. This test involved spiking the catalyst with 200 ppm hydrogen peroxide and then testing the resulting solution to determine the extent of peroxide destruction. Initial testing results of the Sud-Chemie T-2525 catalyst indicated reduced performance, so additional catalyst materials were selected for inclusion in the testing. These materials included Carulite{sup R} 200 catalyst, LayneOx{sup R}, natural manganese ore - pyrolusite (Pro-Ox{sup R}), and EnviCat{sup R} 2531 SPH 4-6. With the expansion of the test scope, fines generation testing was added to provide additional data for product selection, as excessive fines cause plugging in the PDM. The resulting test data are compared to the 2008 catalyst product testing data in order to evaluate performance of each product to determine whether the Sud-Chemie T-2525 is still viable and to determine the best candidate for its replacement. This testing provides essential information to the engineering and operations organizations managing the facility and equipment upgrades for the ETF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasminogen activator Inhibitor-2 inhibits pulmonary arterial smooth muscle cell proliferation in pulmonary arterial hypertension via PI3K/Akt and ERK signaling

Highlights: • Serum PAI-2 is decreased in patients with pulmonary arterial hypertension. • Serum PAI-2 is associated with disease severity in pulmonary arterial hypertension. • Exogenous PAI-2 attenuates monocrotaline induced pulmonary hypertension in rats. • PAI-2 inhibits pulmonary arterial smooth muscle proliferation via PI3K/Akt and ERK. The proliferation of pulmonary arterial smooth muscle cells (PASMCs) and subsequent pulmonary vascular remodeling leads to pulmonary arterial hypertension (PAH). Understanding the underlying mechanisms and identifying molecules that can suppress PASMCs proliferation is critical for developing effective pharmacological treatment. We previously showed that plasminogen activator inhibitor-2 (PAI-2) inhibited human PASMC (hPASMCs) proliferation in vitro. However, its inhibitory effect on PAH remains to be determined, and the mechanism remains to be illustrated.

60 APPLIED LIFE SCIENCES↗

Service Life Extension of the Propulsion System of Long-Term Manned Orbital Stations

One of the critical non-replaceable systems of a long-term manned orbital station is the propulsion system. Since the propulsion system operates beginning with the launch of station elements into orbit, its service life determines the service life of the station overall. Weighing almost a million pounds, the International Space Station (ISS) is about four times as large as the Russian space station Mir and about five times as large as the U.S. Skylab. Constructed over a span of more than a decade with the help of over 100 space flights, elements and modules of the ISS provide more research space than any spacecraft ever built. Originally envisaged for a service life of fifteen years, this Earth orbiting laboratory has been in orbit since 1998. Some elements that have been launched later in the assembly sequence were not yet built when the first elements were placed in orbit. Hence, some of the early modules that were launched at the inception of the program were already nearing the end of their design life when the ISS was finally ready and operational. To maximize the return on global investments on ISS, it is essential for the valuable research on ISS to continue as long as the station can be sustained safely in orbit. This paper describes the work performed to extend the service life of the ISS propulsion system. A system comprises of many components with varying failure rates. Reliability of a system is the probability that it will perform its intended function under encountered operating conditions, for a specified period of time. As we are interested in finding out how reliable a system would be in the future, reliability expressed as a function of time provides valuable insight. In a hypothetical bathtub shaped failure rate curve, the failure rate, defined as the number of failures per unit time that a currently healthy component will suffer in a given future time interval, decreases during infant-mortality period, stays nearly constant during the service life and increases at the end when the design service life ends and wear-out phase begins. However, the component failure rates do not remain constant over the entire cycle life. The failure rate depends on various factors such as design complexity, current age of the component, operating conditions, severity of environmental stress factors, etc. Development, qualification and acceptance test processes provide rigorous screening of components to weed out imperfections that might otherwise cause infant mortality failures. If sufficient samples are tested to failure, the failure time versus failure quantity can be analyzed statistically to develop a failure probability distribution function (PDF), a statistical model of the probability of failure versus time. Driven by cost and schedule constraints however, spacecraft components are generally not tested in large numbers. Uncertainties in failure rate and remaining life estimates increase when fewer units are tested. To account for this, spacecraft operators prefer to limit useful operations to a period shorter than the maximum demonstrated service life of the weakest component. Running each component to its failure to determine the maximum possible service life of a system can become overly expensive and impractical. Spacecraft operators therefore, specify the required service life and an acceptable factor of safety (FOS). The designers use these requirements to limit the life test duration. Midway through the design life, when benefits justify additional investments, supplementary life test may be performed to demonstrate the capability to safely extend the service life of the system. An innovative approach is required to evaluate the entire system, without having to go through an elaborate test program of propulsion system elements. Evaluating every component through a brute force test program would be a cost prohibitive and time consuming endeavor. ISS propulsion system components were designed and built decades ago. There are no representative ground test articles for some of the components. A 'test everything' approach would require manufacturing new test articles. The paper outlines some of the techniques used for selective testing, by way of cherry picking candidate components based on failure mode effects analysis, system level impacts, hazard analysis, etc. The type of testing required for extending the service life depends on the design and criticality of the component, failure modes and failure mechanisms, life cycle margin provided by the original certification, operational and environmental stresses encountered, etc. When specific failure mechanism being considered and the underlying relationship of that mode to the stresses provided in the test can be correlated by supporting analysis, time and effort required for conducting life extension testing can be significantly reduced. Exposure to corrosive propellants over long periods of time, for instance, lead to specific failure mechanisms in several components used in the propulsion system. Using Arrhenius model, which is tied to chemically dependent failure mechanisms such as corrosion or chemical reactions, it is possible to subject carefully selected test articles to accelerated life test. Arrhenius model reflects the proportional relationship between time to failure of a component and the exponential of the inverse of absolute temperature acting on the component. The acceleration factor is used to perform tests at higher stresses that allow direct correlation between the times to failure at a high test temperature to the temperatures to be expected in actual use. As long as the temperatures are such that new failure mechanisms are not introduced, this becomes a very useful method for testing to failure a relatively small sample of items for a much shorter amount of time. In this article, based on the example of the propulsion system of the first ISS module Zarya, theoretical approaches and practical activities of extending the service life of the propulsion system are reviewed with the goal of determining the maximum duration of its safe operation.

Kamath, Ulhas↗

Lifetime risk of suicide among survivors of the atomic bombings of Japan

Abstract Aims The long-term physical health effects of the atomic bombings of Hiroshima and Nagasaki are well characterised, but the psychological effects remain unclear. Therefore, we sought to determine whether measures of exposure severity, as indirect measures of psychological trauma arising from exposure to the atomic bombings, are associated with suicide mortality among atomic bomb survivors. Methods The Life Span Study is a prospective cohort study of 93 741 Japanese atomic bomb survivors who were located within 10 km of the hypocentre in Hiroshima or Nagasaki at the time of the bombings in 1945, and 26 579 residents of Hiroshima and Nagasaki who were not in either city at the time of the bombings, matched to survivors on city, sex and age. Measures of exposure severity included: proximity to the hypocentre, type of shielding between the survivor and the blast and self-reported occurrence of acute radiation and thermal injuries. Date of death was obtained from the Japanese National Family Registry system. Cause of death was obtained from death certificates. Adjusted hazard ratios (HRs) were estimated from Cox regression models overall and stratified by sex and age. Results During the 60-year follow-up period (1950–2009), 1150 suicide deaths were recorded among 120 231 participants (23.6 per 100 000 person-years): 510 among 70 092 women (17.2 per 100 000 person-years) and 640 among 50 139 men (33.6 per 100 000 person-years). Overall, there was no association of proximity, type of shielding or the occurrence of acute injuries with suicide mortality. Among those <25 years of age at the time of the bombings, increased suicide risk was observed for survivors outside v . shielded inside any structure (HR: 1.24; 95% confidence interval (CI): 1.03, 1.48; interaction p = 0.054) and for those who reported flash burns (HR: 1.32; 95% CI: 1.00, 1.73; interaction p = 0.025). Sex-stratified analyses indicated that these associations were limited to men. Among women, closer proximity to the hypocentre was associated with a non-significant increase in suicide risk, with a positive association between proximity and suicide risk observed among women <15 years of age (HR: 1.09 per km; 95% CI: 1.00, 1.18; interaction p = 0.067). Conclusions Proximity to the hypocentre, shielding and acute injury presence do not generally appear to influence suicide mortality among atomic bomb survivors. However, heterogeneity may exist by age and sex, with younger survivors potentially more sensitive to psychological trauma. Coupled with other studies, our results suggest the importance of long-term monitoring of mental health among young populations exposed to catastrophic events or mass trauma.

Psychiatry↗

Structure of the D1-Val185Asn mutated photosystem II complex with slow O–O bond formation reveals changes in the Cl1 water channel

During photosynthesis, the photosystem II (PSII) enzyme catalyzes the light-driven oxidation of water, fueling life on Earth by storing light energy and releasing O 2 as a byproduct. Determining the molecular mechanism for this water oxidation reaction has been of significant interest for the development of synthetic catalysts, but many details remain elusive. One of the open questions is how protons are strategically removed from the active site, a Mn 4 CaO 5 cluster called the oxygen-evolving complex (OEC), during the reaction cycle via conserved water channels, and how proton transfer contributes to O–O bond formation energetics. Site-directed mutagenesis studies have investigated the role of conserved amino acid side chains in facilitating proton transfer. One of the most influential mutations is the Val185Asn substitution on the D1 subunit, which substantially slows O 2 release kinetics without abolishing catalytic activity. Forming a molecular understanding of how this mutation affects the active site will provide insight into the water oxidation reaction mechanism. Here, we investigated the structural basis of the Val185Asn substitution by determining a 1.99 Å-resolution cryo-EM structure. We observed that Asn185 orients away from the OEC and donates a H-bond to Cl1, a conserved chloride ion. We furthermore observed an alternative D2-Glu312-facing conformation of the D2-Lys317 side chain in the Cl1 water channel, a conformation that is consistent with recent models for proton transfer. These changes also produce perturbations to the hydrogen-bonding network. Overall, these finding provide insight into proton transfer in the Cl1 channel and its effect on the water oxidation reaction mechanism.

cryo-EM↗

SU-E-T-794: Validation of the MCNPX Monte Carlo Model of the Ocular Beam Line at the Proton Therapy Center Houston

Purpose: The PTCH is preparing the ocular proton beam nozzle for clinical use. Currently commissioning measurements are being performed using films, diodes and ionization chambers. In parallel, a Monte Carlo model of the beam line was created for integration into the automated Monte Carlo treatment plan computation system, MC{sup 2}. This work aims to compare Monte Carlo predictions to measured proton doses in order to validate the Monte Carlo model. Methods: A complete model of the double scattering ocular beam line has been created and is capable of simulating proton beams with a comprehensive set of beam modifying devices, including eleven different range modulator wheels. Simulations of doses in water were scored and compare to ion chamber measurements of depth doses, lateral dose profiles extracted from half beam block exposures of films, and diode measurements of lateral penumbrae at various depths. Results: All comparison resulted in an average relative entrance dose difference of less than 3% and peak dose difference of less than 2%. All range differences were smaller than 0.2 mm. The differences in the lateral beam profiles were smaller than 0.2 mm, and the differences in the penumbrae were all smaller than 0.4%. Conclusion: All available data shows excellent agreement of simulations and measurements. More measurements will have to be performed in order to completely and systematically validate the model. Besides simulating and measuring PDDs and lateral profiles of all remaining range modulator wheels, the absolute dosimetry factors in terms of number of source protons per monitor unit have to be determined.

60 APPLIED LIFE SCIENCES↗

Prospective Evaluation of Quality of Life and Neurocognitive Effects in Patients With Multiple Brain Metastases Receiving Whole-Brain Radiotherapy With or Without Thalidomide on Radiation Therapy Oncology Group (RTOG) Trial 0118

Purpose: Radiation Therapy Oncology Group (RTOG) 0118 randomized patients with multiple brain metastases to whole-brain radiotherapy (WBRT) {+-} thalidomide. This secondary analysis of 156 patients examined neurocognitive and quality of life (QOL) outcomes. Methods and Materials: Quality of life was determined with the Spitzer Quality of Life Index (SQLI). The Folstein Mini-Mental Status Exam (MMSE) assessed neurocognitive function. SQLI and MMSE were administered at baseline and at 2-month intervals. MMSE was scored with a threshold value associated with neurocognitive functioning (absolute cutoff level of 23) and with the use of corrections for age and educational level. Results: Baseline SQLI predicted survival. Patients with SQLI of 7-10 vs. <7 had median survival time (MST) of 4.8 vs. 3.1 months, p = 0.05. Both arms showed steady neurocognitive declines, but SQLI scores remained stable. Higher levels of neurocognitive decline were observed with age and education-level corrections. Of patients considered baseline age/educational level neurocognitive failures, 32% died of intracranial progression. Conclusions: Quality of life and neuropsychological testing can be prospectively administered on a Phase III cooperative group trial. The MMSE should be evaluated with adjustments for age and educational level. Baseline SQLI is predictive of survival. Despite neurocognitive declines, QOL remained stable during treatment and follow-up. Poor neurocognitive function may predict clinical deterioration. Lack of an untreated control arm makes it difficult to determine the contribution of the respective interventions (i.e., WBRT, thalidomide) to neurocognitive decline. The RTOG has developed a trial to study the role of preventative strategies aimed at forestalling neurocognitive decline in this population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating Fatigue Crack Growth in Spiral Bevel Pinion

This project investigates computational modeling of fatigue crack growth in spiral bevel gears. Current work is a continuation of the previous efforts made to use the Boundary Element Method (BEM) to simulate tooth-bending fatigue failure in spiral bevel gears. This report summarizes new results predicting crack trajectory and fatigue life for a spiral bevel pinion using the Finite Element Method (FEM). Predicting crack trajectories is important in determining the failure mode of a gear. Cracks propagating through the rim may result in catastrophic failure, whereas the gear may remain intact if one tooth fails and this may allow for early detection of failure. Being able to predict crack trajectories is insightful for the designer. However, predicting growth of three-dimensional arbitrary cracks is complicated due to the difficulty of creating three-dimensional models, the computing power required, and absence of closed- form solutions of the problem. Another focus of this project was performing three-dimensional contact analysis of a spiral bevel gear set incorporating cracks. These analyses were significant in determining the influence of change of tooth flexibility due to crack growth on the magnitude and location of contact loads. This is an important concern since change in contact loads might lead to differences in SIFs and therefore result in alteration of the crack trajectory. Contact analyses performed in this report showed the expected trend of decreasing tooth loads carried by the cracked tooth with increasing crack length. Decrease in tooth loads lead to differences between SIFs extracted from finite element contact analysis and finite element analysis with Hertz contact loads. This effect became more pronounced as the crack grew.

Ural, Ani↗

The C 12 ( α , γ ) O 16 reaction and its implications for stellar helium burning

The creation of carbon and oxygen in our Universe is one of the forefront questions in nuclear astrophysics. The determination of the abundance of these elements is key to our understanding of both the formation of life on Earth and to the life cycles of stars. While nearly all models of different nucleosynthesis environments are affected by the production of carbon and oxygen, a key ingredient, the precise determination of the reaction rate of 12 C (α, γ) 16 O , has long remained elusive. This is owed to the reaction’s inaccessibility, both experimentally and theoretically. Nuclear theory has struggled to calculate this reaction rate because the cross section is produced through different underlying nuclear mechanisms. Isospin selection rules suppress the E 1 component of the ground state cross section, creating a unique situation where the E 1 and E 2 contributions are of nearly equal amplitudes. Experimentally there have also been great challenges. Measurements have been pushed to the limits of state-of-the-art techniques, often developed for just these measurements. The data have been plagued by uncharacterized uncertainties, often the result of the novel measurement techniques that have made the different results challenging to reconcile. However, the situation has markedly improved in recent years, and the desired level of uncertainty ≈ 10 % may be in sight. In this review the current understanding of this critical reaction is summarized. The emphasis is placed primarily on the experimental work and interpretation of the reaction data, but discussions of the theory and astrophysics are also pursued. In conclusion, the main goal is to summarize and clarify the current understanding of the reaction and then point the way forward to an improved determination of the reaction rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Roadmapping Minigrid Innovations for Cost Reduction

Electrification of the world's rural regions is a high priority for both the private and public sectors, as it has been linked to economic development, improved education and public health. Minigrid systems, opposed to grid extension, have been identified as the favorable solution for electrification in many cases. However, the life cycle costs of minigrid systems remain too high for widespread implementation. To address this, Colorado State University (CSU) and the National Renewable Energy Laboratory (NREL) hosted a series of 3 workshops to engage a range of minigrid stakeholders to determine common issues underlying the cost of minigrid systems. The series identified numerous areas for further development in technology and business, with equal emphasis on pre-installation, capital/equipment, and operational costs. In addition, the workshop series emphasized the need for better market intelligence and a better understanding of productive use as a means of stimulating energy demand.

cost reduction↗

Human Missions to Europa and Titan - Why Not?

This report describes a long-term development plan to enable human exploration of the outer solar system, with a focus on Europa and Titan. These are two of the most interesting moons of Jupiter and Saturn, respectively, because they are the places in the solar system with the greatest potential for harboring extraterrestrial life. Since human expeditions to these worlds are considered impossible with current capabilities, the proposal of a well-organized sequence of steps towards making this a reality was formulated. The proposed Development Plan, entitled Theseus, is the outcome of a recent multinational study by a group of students in the framework of the Master of Space Studies (MSS) 2004 course at the International Space University (ISU). The Theseus Program includes the necessary development strategies in key scientific and technological areas that are essential for identifying the requirements for the exploration of the outer planetary moons. Some of the topics that are analysed throughout the plan include: scientific observations at Europa and Titan, advanced propulsion and nuclear power systems, in-situ resource utilization, radiation mitigation techniques, closed life support systems, habitation for long-term spaceflight, and artificial gravity. In addition to the scientific and technological aspects of the Theseus Program, it was recognized that before any research and development work may begin, some level of program management must be established. Within this chapter, legal issues, national and international policy, motivation, organization and management, economic considerations, outreach, education, ethics, and social implications are all considered with respect to four possible future scenarios which enable human missions to the outer solar system. The final chapter of the report builds upon the foundations set by Theseus through a case study. This study illustrates how such accomplishments could influence a mission to Europa to search for evidence of life in its subsurface oceans. The future remains unpredictable, as does the realization of any of these possibilities. However, projects such as this remind us that the final frontier for humans is truly outer space, and only our imagination will determine where the frontier stops. We can dream of visiting other planetary systems and perhaps even galaxies, but we must begin closer, and considering the scope of our known universe, Europa and Titan are very close indeed.

FROM↗

A dosimetric comparison of proton and photon therapy in unresectable cancers of the head of pancreas

Purpose: Uncontrolled local growth is the cause of death in ∼30% of patients with unresectable pancreatic cancers. The addition of standard-dose radiotherapy to gemcitabine has been shown to confer a modest survival benefit in this population. Radiation dose escalation with three-dimensional planning is not feasible, but high-dose intensity-modulated radiation therapy (IMRT) has been shown to improve local control. Still, dose-escalation remains limited by gastrointestinal toxicity. In this study, the authors investigate the potential use of double scattering (DS) and pencil beam scanning (PBS) proton therapy in limiting dose to critical organs at risk. Methods: The authors compared DS, PBS, and IMRT plans in 13 patients with unresectable cancer of the pancreatic head, paying particular attention to duodenum, small intestine, stomach, liver, kidney, and cord constraints in addition to target volume coverage. All plans were calculated to 5500 cGy in 25 fractions with equivalent constraints and normalized to prescription dose. All statistics were by two-tailed paired t-test. Results: Both DS and PBS decreased stomach, duodenum, and small bowel dose in low-dose regions compared to IMRT (p < 0.01). However, protons yielded increased doses in the mid to high dose regions (e.g., 23.6–53.8 and 34.9–52.4 Gy for duodenum using DS and PBS, respectively; p < 0.05). Protons also increased generalized equivalent uniform dose to duodenum and stomach, however these differences were small (<5% and 10%, respectively; p < 0.01). Doses to other organs-at-risk were within institutional constraints and placed no obvious limitations on treatment planning. Conclusions: Proton therapy does not appear to reduce OAR volumes receiving high dose. Protons are able to reduce the treated volume receiving low-intermediate doses, however the clinical significance of this remains to be determined in future investigations.

60 APPLIED LIFE SCIENCES↗

Impedance Noise Identification for State-of-Health Prognostics

Impedance Noise Identification is an in-situ method of measuring battery impedance as a function of frequency using a random small signal noise excitation source. Through a series of auto- and cross-correlations and Fast Fourier Transforms, the battery complex impedance as a function of frequency can be determined. The results are similar to those measured under a lab-scale electrochemical impedance spectroscopy measurement. The lab-scale measurements have been shown to correlate well with resistance and power data that are typically used to ascertain the remaining life of a battery. To this end, the Impedance Noise Identification system is designed to acquire the same type of data as an on-board tool. A prototype system is now under development, and results are being compared to standardized measurement techniques such as electrochemical impedance spectroscopy. A brief description of the Impedance Noise Identification hardware system and representative test results are presented.

25 ENERGY STORAGE↗

Instrumentation and Methods to Measure Dynamic Forces During Exercise Using the Horizontal Exercise Machine

It is hypothesized that bone loss experienced by astronauts in zero gravity conditions may be curtailed by appropriate exercise. According to Wolf's law, bone regenerates when muscles produce stresses by pulling on the bone during daily activity and/or exercise on Earth. To use this theory to prevent or decrease bone loss, one needs to quantify musculoskeletal loads and relate them to bone density changes. In the context of the space program, it is desirable to determine musculoskeletal loads during exercise so that one may make similar measurements on Earth and in space. In this manner, load measurements on Earth may be used as reference to generate similar loads during exercise in space. A research project to investigate the effects of high-resistive exercise to decrease bone density loss underzero-gravity conditions is being carried out in Life Sciences Research Laboratories at NASA JSC. The project consists of a bed-rest study whereby subjects remain in horizontal position for seventeen weeks. During the study, a subset of those subjects executes a regime of resistive exercises in the horizontal exercise machine (HEM). The HEM was designed so that subjects remain horizontal while exercising to minimize gravity loading even during exercise. Bone density of each subject is measured throughout the duration of their participation. The objective of the study is to determine if the resistive exercises are effective in diminishing or eliminating bone loss. My participation in this project relates to instrumentation, measurement, and processing of signals from displacement sensors (optical encoders) and load-cells. Measurement of displacements will be used to determine the motion of the body during exercise, and load measurements will be used (along with displacement data) to determine forces and torques exerted on each section of the body during exercise. Further, I have assisted in specifying new sensors to be added to the HEM and to a new prototype resistive exercise machine called the Interim Resistive Exercise Device (IRED). New load cells and encoders should be mounted in these devices to obtain more complete kineto-dynamic information. This report includes a description of the instrumentation that was built to perform measurements in the HEM and the IRED, along with the software that was developed to collect the measurements. It also includes examples of measurements taken in the HEM. Finally, a plan is laid out that describes how these measurements may be used to determine forces exerted by muscles for each exercise.

Figueroa, Fernando↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

A Review of Pump Package Assembly Anomalies and Demonstration to Gain Motor Controller Replacement Capability

The International Space Station (ISS) generates heat within the US modules from systems used to operate the station, maintain crew health, and conduct science experiments in the orbiting laboratory. The Internal Thermal Control System (ITCS) collects this heat in water loops and transfers it to the external ammonia system for rejection to space. The ITCS uses six Pump Package Assemblies (PPA) as the motive force to circulate the water within the Lab, Node 2, and Node 3 (Node 1 is parasitic to the Lab and Node 3 ITCS loops). In the life of ISS, 3 PPAs have had to be replaced and 2 PPAs are currently showing signs of degradation. The first PPA to fail in 2003 was due to early coolant chemistry issues; the remaining pump failures and current pump degradations are determined to be related to the Pump/Fan Motor Controller (PFMC), with their individual signatures all being unique to this point. The PFMC of one of the failed PPAs was returned and testing confirmed its sub-components to be the root cause of the PPA failure. Due to the relative size and weight of the standalone PFMC in comparison to the integrated assembly, it is desired, from a launch and on-orbit stowage perspective, to replace the PFMC component of the degraded PPA instead of the entire PPA. The PPA was not designed for this capability, so on the ground demonstrations are planned using crew tools to show that the PFMC can be replaced on-orbit while maintaining full functionality. This paper will focus on the signatures of the two most recent PPA failures and the two PPAs showing signs of degradation, in addition to presenting the findings from the PFMC demonstration effort.

Aaron Rodriguez↗

Effect on interference fits on roller bearing fatigue life

An analysis was performed to determine the effects of inner-ring speed and press fits on roller bearing fatigue life. The effects of the resultant hoop and radial stresses on the principal stresses were considered. The maximum shear stresses below the Hertzian contact were determined for different conditions of inner-ring speed and load, and were applied to a conventional roller bearing life analysis. The effect of mean stress was determined using Goodman diagram approach. Hoop stresses caused by press fits and centrifugal force can reduce bearing life by as much as 90 percent. Use of a Goodman diagram predicts life reductions of 20 to 30 percent. The depth of the maximum shear stress remains virtually unchanged.

Coe, H. H.↗