Search NASA⌕ Search

SEARCH · Search NASA

Results for “Risk Remediation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensitivity Analysis of Effectiveness of FLEX Strategies Using a CDF-Based Importance Measure Under Accident Conditions

One of the lessons learned from the Fukushima Daiichi nuclear power plant (NPP) accident is strengthening the station blackout (SBO) mitigation capabilities by enhancing defense in depth for all existing and new NPPs. One of the possible remedies is diverse and flexible coping strategies (FLEX). The objective of this study is to address the benefits of FLEX in various accident scenarios in terms of both risk and cost. FLEX was originally devised against SBO accidents. In this research, we investigate the fundamental plant responses against accidents considering two fundamentally different cases: accidents that lead to high pressure on the primary side and accidents that lead to low pressure on the primary side. Several uncertainties are associated with the characteristics of the FLEX portable equipment. Specifically, the time for FLEX deployment may depend on several factors such as type of accident, point of injection, availability of safety systems, battery backup timings, and human actions. This study utilizes a dynamic risk assessment framework to analyze accident scenarios and suggests a novel importance measure, which is a cumulative distribution function– based importance metric that characterizes the influence of input distribution on complete output distribution. The importance of the existing and newly developed FLEX strategy based on risk significance is illustrated with examples. The suggested measure provides clear insight into how FLEX affects risk of the whole system and additional risk margins thanks to new safety systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Iodine Air Sampling: Installation and Preliminary Results

The F-Area wetlands are a known sink for radioiodine generated at the Savannah River Site (SRS). Wastewater containing iodine-129 ( 129 I) was discharged into the F-Area Seepage Basins for disposal, but the acidity of the wastewater mobilized some of the contaminants from the basin soil through the vadose zone and into the groundwater; ultimately creating a groundwater plume that extends towards Fourmile Branch and its associated wetland areas. Dissolved radioiodine specifically has migrated to the nearby F-Area wetlands, where it persists as a contaminant of concern. Accumulation and resurfacing of 129 I in the wetlands and nearby areas creates a potential secondary source zone where changes in biogeochemical conditions could result in the release of this sequestered 129 I to the air. Monitoring data has indicated that 129 I has a seasonal behavior at several surface water stations, with high concentrations during summertime and low concentrations during wintertime. Still, it is not known which factors control the seasonal behavior of 129 I. Further, it has been reported that 129 I contributed approximately 23% to the 2019 SRS offsite air pathway dose to the representative person for that year (SRNS, 2020), but air measurements of 129 I have never been taken in the F-Area wetlands. Because air emissions of 129 I from the wetlands have never been investigated, it is not known if this could be a potential release pathway that needs to be included in the site conceptual model. To address these unknowns, the Savannah River National Laboratory (SRNL) has an applied research task to investigate whether 129 I in the wetlands is emitted to the air and, if so, whether air concentrations exhibit seasonal variation. This report presents information about the system recently installed in the F-Area wetlands for measuring 129 I, as well as analysis results for samples collected June through August 2023. Quantification of this constituent will provide a better understanding of the contribution of airborne 129 I from the F-Area wetlands to the offsite dose and better inform ongoing and future remedial actions.

54 ENVIRONMENTAL SCIENCES↗

Policy-relevant differences between secondhand and thirdhand smoke: strengthening protections from involuntary exposure to tobacco smoke pollutants

Starting in the 1970s, individuals, businesses and the public have increasingly benefited from policies prohibiting smoking indoors, saving thousands of lives and billions of dollars in healthcare expenditures. Smokefree policies to protect against secondhand smoke exposure, however, do not fully protect the public from the persistent and toxic chemical residues from tobacco smoke (also known as thirdhand smoke) that linger in indoor environments for years after smoking stops. Nor do these policies address the economic costs that individuals, businesses and the public bear in their attempts to remediate this toxic residue. We discuss policy-relevant differences between secondhand smoke and thirdhand smoke exposure: persistent pollutant reservoirs, pollutant transport, routes of exposure, the time gap between initial cause and effect, and remediation and disposal. We examine four policy considerations to better protect the public from involuntary exposure to tobacco smoke pollutants from all sources. We call for (a) redefining smokefree as free of tobacco smoke pollutants from secondhandandthirdhand smoke; (b) eliminating exemptions to comprehensive smoking bans; (c) identifying indoor environments with significant thirdhand smoke reservoirs; and (d) remediating thirdhand smoke. We use the case of California as an example of how secondhand smoke-protective laws may be strengthened to encompass thirdhand smoke protections. The health risks and economic costs of thirdhand smoke require that smokefree policies, environmental protections, real estate and rental disclosure policies, tenant protections, and consumer protection laws be strengthened to ensure that the public is fully protected from and informed about the risks of thirdhand smoke exposure.

Public, Environmental & Occupational Health↗

Uptake, Efflux, and Sequestration of Mercury in the Asian Clam, Corbicula fluminea , at Environmentally Relevant Concentrations, and the Implications for Mercury Remediation

(1) Mercury (Hg) is a persistent, ubiquitous contaminant that readily biomagnifies into higher trophic level species in aquatic environments across the globe. It is crucial to understand the movement of environmentally relevant concentrations of Hg in impacted freshwater streams to minimize risks to ecological and human health. (2) The bioconcentration kinetics of aqueous Hg exposure (20, 100, and 200 ng/L) in the invasive Asian Clam, Corbicula fluminea, were measured. A toxicokinetic model, the first parameterized for Hg accumulation in freshwater clams, was developed to estimate uptake and efflux parameters and compared to previous parameter values estimated for other mollusk species. (3) Results demonstrated that even at low Hg concentrations, Corbicula record signals of contamination through bioconcentration, and both direct measurement and toxicokinetic models demonstrate large Hg bioconcentration factors (as high as 1.34 × 10 5 mL/g dry tissue), similar to partitioning coefficients seen in engineered Hg sorbents. (4) Our study found that Corbicula accumulated Hg at aqueous concentrations relevant to impacted streams, but well below regulatory drinking water limits, demonstrating their utility as a sensitive sentinel species and potential bioremediator.

bioaccumulation↗

Qualitative Risk Assessment of Legacy Wells within the Estimated Prairie State Generating Company Area of Review

This report details the digitization of a legacy wellbore database, including data processing assumptions, parameter estimation, and risk assessment methodology. The database, comprising 6,454 documents, was provided by ISGS. It includes valuable data from the Prairie State Generating Company (PSGC) and One Earth Energy (OEE) sites of the CarbonSAFE Phase III – Illinois Storage Corridor project. The report focuses on wells within a 15-mile radius from the Lively Grove #1 (LG#1) well at PSGC site, evaluating subsurface conditions and potential risks. A total of 4,386 wellbores within 15 miles of the LG#1 well were filtered based on depth and formation codes. LG#1 is the stratigraphic well at the PSGC site drilled in 2021. Ninety-four (94) wells penetrating the Maquoketa Shale Group (the primary confining unit) within the estimated area-of-review (AoR) for the PSGC site were evaluated using a qualitative risk assessment (QRA) methodology. The QRA developed by Arbad et al. 2022 focuses on legacy wells within the AoR and categorizes them based on well construction details. The QRA identifies wells that need immediate attention by categorizing them based on penetration depth and protection. Wells within the AoR were categorized into nine groups based on penetrations and protections. These categories range from Type 1 wells, with no documentation, to Type 9 wells, which do not penetrate the primary confining unit or storage reservoir (unit). Well accessibility within the AoR varies based on well status, including Dry & Abandoned (DA), Plugged & Abandoned (PA), Injection (INJ), Oil/Gas Producing (PROD), and Observation (Obs) wells. Accessibility levels were determined by well construction, with DA wells being the least accessible and Observation wells the most accessible, impacting gas leakage detection possibilities. Remedial action priority of wells decreases from Type 1 to Type 9 wells. Type 1 to Type 6 wells with status DA and PA require immediate attention, while Type 7 and Type 8 wells are low priority. A risk matrix used to prioritize corrective actions for legacy wells is proposed to categorize wells within an AoR based on penetrations, protections, and accessibility. The methodology involves data acquisition, well categorization into nine types, and determining CO 2 leakage pathways using well schematics and geospatial mapping. This approach is particularly useful for managing the integrity of legacy wells throughout the lifecycle of a Carbon Capture and Storage (CCS) project. A qualitative risk assessment of 94 wells within the AoR of the PSGC site identified 54 wells with high priority for corrective action due to penetration of the primary containment seal. The assessment utilizes color-coded maps to categorize well types and prioritize corrective actions, providing a comprehensive analysis. Schematics of wells penetrating the primary confining unit were drawn, and leakage pathways were identified. Details of all wells penetrating the confining zone are provided in the appendix, including information on well types, plugging, and casing status.

01 COAL, LIGNITE, AND PEAT↗

Co-Firing Switchgrass and Waste Coal in A Power Plant: A Techno-Economic and Life Cycle Evaluation for The Ohio River Valley (SWITCH) (Final Technical Report for Ohio State/FE0032204)

Abandoned coal mine lands (AMLs) represent one of the most persistent environmental challenges in the United States. Prior to the enactment of the Surface Mining Control and Reclamation Act (SMCRA) in 1977, coal mining operations were not legally required to reclaim disturbed lands, leaving behind approximately 500,000 AML sites nationwide. These sites pose severe environmental and health risks, including acid mine drainage, soil and water contamination, and spontaneous combustion of waste coal piles. Millions of Americans live within one mile of these AMLs, underscoring the urgency of remediation. Traditional reclamation practices, such as planting cool-season grasses, often fail to fully restore ecological function or leverage the economic potential of these lands. This project addressed these challenges by developing integrated strategies for resource recovery, land reclamation, and sustainable energy production. This project evaluated an integrated strategy to convert this liability into an opportunity by recovering waste coal and co-firing it with switchgrass (Panicum virgatum L.) cultivated on reclaimed or marginal AML areas in existing coal-fired power plants. Switchgrass not only provides a renewable feedstock but also aids in land reclamation and carbon sequestration. 1) Remote Sensing and Machine Learning for Waste Coal Identification Using Sentinel-2 satellite imagery and supervised classification, we applied four machine learning models to detect historical waste coal piles. Random Forest achieved the highest accuracy (precision: 86%, recall: 77%). Time-series analysis revealed gradual vegetation recovery since 1986, indicating natural reclamation processes in historical sites, while active mining areas showed ongoing disturbance. This workflow enables scalable monitoring and prioritization of reclamation efforts. 2) UAS-Based Stockpile Volume Estimation To quantify recoverable waste coal, we evaluated Unmanned Aerial Systems (UAS) equipped with Light Detection and Ranging (LiDAR) and multispectral sensors. Structure-from-Motion (SfM) photogrammetry combined with interpolated Digital Terrain Models (DTMs) achieved strong agreement with LiDAR reference volumes (Root Mean Square Error (RMSE) ≈147 m 3 , Mean Absolute Percentage Error (MAPE) ≈2%). Sensitivity analysis confirmed that spatial resolution significantly influences accuracy, emphasizing the need for high-resolution data for precise volume estimation. This approach offers a scalable, cost-effective, and accurate alternative to conventional ground-based surveys. 3) Switchgrass Cultivation for Bioenergy and Water Quality Improvement We assessed the hydrological and water quality impacts of converting AMLs to switchgrass production areas using the Soil and Water Assessment Tool (SWAT). Results showed that converting 10% of the watershed area into the switchgrass production zone reduced streamflow by 3.1%, total suspended solids by 18.1%, total nitrogen by 7.6%, and total phosphorus by 6.2%, while achieving biomass yields of 8.6–9.2 metric tons per hectare. These findings highlight switchgrass as a dual-benefit strategy for land reclamation and bioenergy feedstock production. 4) Integrated Co-Firing and CCS for Carbon-Negative Power Generation We modeled co-firing scenarios using the Power Plant Flexible Model (PPFM) to evaluate plant efficiency, greenhouse gas (GHG) emissions, and levelized cost of electricity (LCOE). Without carbon capture and storage (CCS), increasing switchgrass co-firing ratios reduced LCOE from $\$$150/MWh at 0% biomass to $\$$110/MWh at full substitution. Under CCS, costs remained higher (~$\$$250/MWh at 0% biomass) but decreased to $\$$200/MWh at 100% biomass, while enabling net-zero or carbon-negative electricity due to switchgrass sequestration benefits. Although CCS introduced efficiency penalties, pairing it with biomass co-firing offset these impacts and maximized climate benefits. Overall, optimizing co-firing ratios between 60-100%, supported by reliable logistics and storage strategies, emerged as a practical pathway to balance affordability, sustainability, and net-zero or negative GHG emissions while promoting productive reuse of AMLs.

01 COAL, LIGNITE, AND PEAT↗

Ion-Specific Precipitation of Extractants Enables Rare-Earth Separation and Wastewater Remediation from Solvent Extraction of Critical Elements

The increasing demand for rare-earth elements (REEs) necessitates sustainable recovery strategies, particularly from secondary sources, such as electronic waste. Solvent extraction is the primary industrial method for REE separation; however, the unintentional dissolution of extractants into wastewater poses serious environmental risks, leading to organic contamination and process inefficiencies. Existing wastewater treatment methods struggle to remove these persistent pollutants, underscoring the need for innovative recovery approaches. Herein, we present a ligand-mediated precipitation strategy that simultaneously recovers REEs and removes dissolved extractants from solvent extraction wastewater. We show that residual extractants in the aqueous phase can selectively bind REEs, inducing their precipitation while leaving transition metals in solution. By integrating FTIR spectroscopy, EDS, XPS, EXAFS, and SAXS, we elucidate the mechanism of ion-specific precipitation and the local coordination environment of metal ions in the precipitate. Importantly, we demonstrate that the precipitated extractants can be efficiently recovered and reused, providing a closed-loop solution that enhances sustainability. Applying this method to leachates from samarium–cobalt (Sm–Co) and neodymium–iron–boron (NdFeB) mixed magnets, we achieve highly selective REE precipitation under mild conditions, demonstrating a scalable and cost-effective pathway for REE recovery, wastewater purification, and extractant recycling. In conclusion, by integrating element-specific ligand-mediated precipitation with extractant reuse, this work offers a transformative approach to REE separation that reduces the environmental impact while improving resource efficiency.

E-waste↗

The Future Role of Hydropower in the Northeastern United States: May 2020-May 2022

This paper explores the future role of hydropower in the Northeastern US and beyond. The intent is to provide experience-based insights into how hydropower can best support the reliable and economic evolution of the New England power system and, more broadly, all US grids. Many of the challenges facing New England are driven by the potential integration of 10s of GWs of variable energy resources. Hydro can assist in remediating several issues, and the paper explores how Hydro might hit above its weight in a future low carbon New England system. Hydro can assist in handling periods of over generation, reduce the risk of curtailment of zero carbon resources, improve market efficiency, and provide valuable essential reliability services.

13 HYDRO ENERGY↗

Evaluation of Dose- and Risk-Based Groundwater Cleanup Levels for Low Energy Beta Radioisotopes

Low-energy beta-emitting radionuclides that were released historically during reactor operations and plutonium separations activities at some U.S. Department of Energy sites have migrated into the groundwater, forming contaminant plumes that are subject to federally regulated remediation actions. At the Hanford Site, the low-energy beta-emitting radionuclides include iodine-129, technetium-99, chlorine-36, carbon-14, and tritium (H-3). All are highly mobile in the subsurface, and except for tritium, and have very long half-lives—thousands to millions of years. The geochemistry and transport behavior of these contaminants in the subsurface present significant challenges for remediation of groundwater to federal drinking water standards (DWS)—the appropriate or relevant and applicable requirements (ARARs) for cleanup. For some of the low-energy beta-emitter contaminants, particularly iodine-129, cleanup and restoration of groundwater to DWS may not be attainable within a reasonable timeframe using currently available treatment technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opportunities to Implement Solutions to Achieve Remedial Action Objectives in Consideration of Stakeholder Interests - 20365

A case study in the implementation of a soils excavation and removal project conducted at a Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) vicinity property; an active commercial business, in a densely populated area, with significant operational, technical and, logistical constraints that were expected to limit areas that could be remediated. The United States Army Corps of Engineers-led (USACE) team successfully navigated complex overlapping stakeholder interests to achieve a more efficient and complete removal of contaminated soils and debris while minimizing unnecessary excess costs to the Government. This paper centers on FUSRAP activities at the FMSS vicinity property located at 149-151 Maywood Avenue, Maywood, Bergen County, New Jersey. For most of its FUSRAP history, this ∼109,000 square meter (27-acre) property housed a now-demolished ∼26,000 square meter (6.5-acre) warehouse operated by Sears Logistics Services, a unit of the Sears Roebuck Company (Figure 2). Sears ended its property lease and vacated the warehouse in December 2016. Given that long history and for the purposes of this paper, the property will be referred to as the 'Sears property' or simply 'the property.' The Sears property is approximately 109,000 square meters (27-acres) and is currently zoned for commercial use. The property is bound to the north and northwest by 100 West Hunter Avenue (the Stepan Company), to the northeast by 205 Maywood Avenue, to the east by Maywood Avenue, to the south by 23 West Howcroft Road, and to the west by businesses on NJ Route 17 and the NJ Route 17 roadway. Until December 2016, the property housed a warehouse and distribution center operated by Sears Logistical Services. On-site structures were demolished by the property owner in 2017. The warehouse covered the north section of the property along the Stepan Company property line. A railroad spur from the adjacent property now known as the Maywood Interim Storage Site (MISS) ended at the northeast corner of the warehouse. Wetlands were located east of the warehouse; the rest of the property was covered with paved parking lots and grassed areas. During remediation at the property, opportunities frequently arose where the project team was able to coordinate effectively with stakeholders to sequence remediation activities to facilitate removal of otherwise inaccessible soils and identify opportunities for materials reuse when supported by residual radiological and chemical levels. Some specific opportunities include: - remediating individual truck loading dock bays to maintain tenant operations; - working along a busy highway and in a utility corridor containing a 30-inch high pressure gas main; - remediating Lodi Brook and associated wetlands requiring bypass pumping and other diversionary structures to maintain local community stormwater drainage; - protecting during remediation and supporting access to facilitate tenant/owner maintenance of critical fire protection and water supply system service lines buried in contaminated soils and necessary for safe warehouse operations; and - coordinating with stakeholders to ensure non-radiological contaminants of concern for the site (unaffiliated with FUSRAP) were addressed by the responsible party in a manner that maximized benefit to all parties while supporting an efficient overall site remediation program. Once the property was vacant and the warehouse structure and radiologically non-impacted above-grade structures were demolished, the project identified an opportunity to significantly reduce the volume of waste associated with the foundation of the former warehouse, a foundation suspected of being partially constructed in radiologically contaminated soils. The project developed and implemented supplemental radiological verification survey and sampling strategies based on radiological cross-contamination risk potential with process flow-charts and screening-level based decision points; a program that classified saw-cut sections of concrete based on observed residual surface radioactivity conditions using a combination of gamma sensitive sodium-iodide scans and beta sensitive Geiger-Muller direct measurements. The proposed approach was reviewed with stakeholders with feedback, including consideration of applicable State of New Jersey Site Remediation Program criteria and guidance before implementation. Once classified, additional sampling was performed at frequencies driven by screening. The sampling methods, stockpile sampling frequencies, criteria and, approach to data evaluation were developed in consideration of existing site cleanup standards, regional background ranges, State of New Jersey radiological remediation program guidance, and specific stakeholder input With the property remediation and survey efforts nearly completed, it is relevant to examine retrospectively the objectives, assumptions and limitations in the remedial design (i.e., what was planned) versus what was able to be accomplished through effective teaming. Benefits to other environmental remediation site programs include better understanding of how to work effectively with stakeholders to achieve win-win outcomes, and approaches to site remediation, waste minimization and materials reuse that were successful in their overall outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life-Cycle Baseline Customization for the Formerly Utilized Sites Remedial Action Program - 20304

One of the responsibilities of the federal government is to estimate sound and defensible life-cycle baseline costs for use in federal budget estimates and to meet federal financial reporting requirements. To accomplish this, the US Department of Energy (DOE) Office of Legacy Management (LM) and the US Army Corps of Engineers (USACE) have partnered together to ensure that the liabilities documented in each Formerly Utilized Sites Remedial Action Program (FUSRAP) site's life-cycle baseline are specifically tailored. FUSRAP was created in the mid-1970's to clean up radiological contamination resulting from the early development of nuclear weapons. DOE was responsible for FUSRAP until October 1997, when Congress transferred the administration and execution of FUSRAP site cleanups to USACE. By 1997, DOE had completed the cleanup of 25 of the 46 sites that were active within the program and had begun cleanup at 13 additional sites. USACE was assigned responsibility for the cleanup of the 21 remaining FUSRAP sites, and at 8 additional sites that had since been referred for cleanup. The LM mission for the FUSRAP sites is to perform long-term surveillance and maintenance (LTS and M). Currently, LM provides long-term stewardship for 34 completed FUSRAP sites. Another 20 sites are under active remediation by USACE. Within the last 5 years, USACE has completed the cleanup at five FUSRAP sites and the LTS and M responsibility has been transferred to LM. By 2029, USACE will compete remediation at eight additional sites and LTS and M for those sites will transfer to LM. Because responsibilities for the FUSRAP sites transfer between USACE and LM upon completion of remedial actions, both agencies maintain life-cycle baselines for different stages of the project and both must have a strong understanding of the needs and requirements for each site. This understanding ensures that the life-cycle baselines form a complete and accurate picture of what is required for the site and for the FUSRAP program. LM focuses on several things when customizing the life-cycle baseline estimates for the FUSRAP sites, including (1) Understanding the unique requirements for each site. By reviewing site-specific documents prepared by USACE, such as Feasibility Studies and Records of Decision, and partnering with USACE to gain additional insight about site conditions and requirements for stewardship, as well as potential risks, LM can better develop the life-cycle baselines. (2) Developing site-specific labor breakdowns. This ensures the required labor mix is baselined for specific activities by comparing the labor mix required to perform activities at (a) other LM-managed FUSRAP sites and (b) non-FUSRAP LM sites and (c) by USACE at active FUSRAP sites. (3) Taking a tiered approach to life-cycle baseline planning. Estimates for sites transferring to LM in the near term (5 years) are more definitive than for sites transferring in the out-year period. Remedial actions at the near-term sites are at or near completion, providing LM a strong understanding of the LTS and M requirements and remaining liabilities. This in turn allows for site-specific customization of the baseline. (4) Using a robust risk management approach to ensure that liabilities specific to each site are identified, evaluated by probability and severity, and documented in relation to the impact to cost or schedule. To ensure the most accuracy within all the baselines, the FUSRAP life-cycle baselines are updated as needed to support program, project, and contract management needs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interactions between phosphate and arsenic in iron/biochar-treated groundwater: Corrosion control insights from column experiments

An increasing number of studies have reported the coexistence of arsenic (As) and phosphorus at high concentrations in groundwater, which threatens human health and increases the complexity of groundwater remediation. However, limited work has been done regarding As interception in the presence of phosphate in flowing systems. In this study, a series of experiments were conducted to evaluate the interactions between phosphate and As during As removal by iron (Fe)-based biochar (FeBC). The addition of phosphate promoted As removal by FeBC in the batch and column experiments. X-ray absorption near edge structure (XANES) analysis provided evidence of simultaneous oxidation and reduction of trivalent arsenic in the FeBC column experiment, accompanied by corrosive Fe oxidation. However, the addition of phosphate enhanced As stabilization, attributed to the As-incorporated Fe-Ca-phosphates precipitates. The involvement of phosphate decelerated the Fe corrosion and the formation of secondary minerals in the column, mediating the risk of passivation and clogging. The As retained by Fe-Ca-phosphate precipitates was more readily oxidized, resulting in higher proportions of pentavalent arsenic. In conclusion, the results of this work identify the corrosion control and sustained-release roles of phosphate in FeBC application, informing the perspective of FeBC in As-contaminated groundwater remediation and providing new insights into the interactions between phosphate and As.

54 ENVIRONMENTAL SCIENCES↗

Optimization Efforts at DWPF to Ensure Waste Tank Closure by 2037 – 24404

At the Savannah River Site (SRS) in Aiken, South Carolina, the Defense Waste Processing Facility (DWPF) produces a glass-form product by processing high-level liquid waste (HLW) with borosilicate glass in a high-heated Melter, then putting the vitrified waste into stainless-steel canisters. Since 1996, DWPF has performed this vitrification process for the liquid waste mission at the SRS; the overall objective for this mission is to reduce the volume in the upstream waste tanks, so those tanks can be emptied and operationally closed. This mission seeks to eliminate the single biggest environmental risk in the state of South Carolina, which requires a robust processing strategy within the DWPF, along with optimal interface between the other facilities in the liquid waste organization (LWO). As of the end of July 2023, DWPF has safely remediated 63.7 MCi of HLW, and filled 4,319 canisters (We project that about 4,000 more canisters are needed to be filled to reach the closure goal.)

Armstead, III, Frank L.↗

Air Exchange Rate Impact on Activity Equilibrium Factors and Inhalation Fractional Equilibrium Factors for Rn, Xe, Kr, Ar, Ne, and Their Progeny in Vapor Intrusion, Risk, and Dose Models

Exposure to the radioactive noble gasses, especially radon, is of high concern and poses a significant risk to humans in an indoor air environment as the second leading cause of lung cancer in the United States. To evaluate and minimize the risks posed by these gasses, it is important to understand their radiological and physical properties. The EPA’s Radon Vapor Intrusion Screening Level (RVISL) calculator calculates indoor air RVISLs based on target working levels (WLs), target excess lifetime cancer risk (ELCR), and annual dose limits for the actinon (Rn-219), thoron (Rn-220), and radon (Rn-222) decay series. The RVISLs are based on inhalation and submersion in gas cloud exposure routes for residential and commercial settings. The RVISLs are analogous to preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs), where the isotope-specific values are in units of activity concentration (activity per unit volume). If the concentration of a parent isotope of radon or its progeny is found to exceed the RVISL, then further action to ensure cleanup of the contaminant may be necessary. In residential and commercial settings, the RVISLs will vary based on the air exchange rate present. The EPA’s Radionuclide PRG and DCC Calculators also assess the risk/dose from noble gases in the air due to household use of water like showering. In this study, a computational method in MATLAB was developed to determine the impact of the air exchange rate on the activity equilibrium factor (A eq ) and the inhalation fractional equilibrium factor (F eq ). Both factors are values that reflect the equilibrium concentrations of progeny to their parent in the air. These factors have a direct impact on the RVISL, PRG, and DCC calculations of WL, ELCR, and annual dose, respectively. This study builds on a previous report that only focused on actinon, thoron, and radon by revisiting the original A eq and F eq calculation methods, as well as including the values for the Rn-207, Rn-209, Rn-210, Rn-211, Rn-215, Rn-216, Rn-217, Rn-218, Rn-223, Ne-24, Ar-42, Ar-43, Ar-44, Kr-74, Kr-75, Kr-76, Kr-77, Kr-88, Kr-89, Xe-120, Xe-121, Xe-122, Xe-123, Xe-135m, and Xe-138 decay chains, which are not currently available in literature. The EPA’s RVISL calculator will be updated to include the new A eq and F eq values for the actinon, thoron, and radon decay chains, while the rest of the calculators will incorporate all the new A eq and F eq values as appropriate.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Multi-Analytical Investigation of Arsenical Transfer and Remediation on Nineteenth-Century Green Books

Books containing heavy metals, specifically nineteenth-century green arsenical books, have been identified at Northwestern University Libraries, raising health and safety concerns related to handling. Copper acetoarsenite pigments, such as emerald green, were detected on book covers, decorative page edges, labels, and other components using noninvasive analytical techniques including X-ray fluorescence (XRF), Raman spectroscopy, and Fourier-transform infrared (FTIR) spectroscopy. Further examination of selected volumes using synchrotron radiation (SR) techniques revealed pigment migration, degradation, and arsenic transfer to adjacent books. This paper expands on initial findings through two related experiments. The first explored the transfer of arsenic using mechanical friction; Staedtler Mars® white vinyl erasers rubbed on arsenical books generated crumbs which were analyzed via scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM-EDX). Results confirmed the transfer of arsenic, copper, and lead, with decorative page edges being particularly prone to shedding arsenic onto other materials. The second experiment tested remediation methods on a book contaminated by prolonged exposure to an arsenical neighbor. Surface cleaning using erasers and a vacuum removed flecks of pigment but did not eliminate non-chromophoric arsenic as confirmed by SR analyses, which highlights its presence either as a degradation product embedded within the paper or present in the paper as part of its production process. Findings demonstrate the acute toxicity risk posed by arsenical books and support the need for safe handling protocols. However, materials with only trace levels of arsenic embedded during production may pose a lower risk of transfer. Cross contamination beyond prolonged direct contact appears limited. These results highlight critical considerations for library preservation practices and future research on arsenic in historical materials.

arsenic↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Metal–Organic Frameworks for Per- and Polyfluoroalkyl Substances Treatment in Contaminated Water

Per- and polyfluoroalkyl substances (PFAS) are synthetic pollutants known for their chemical stability, environmental persistence, and toxicological risks. Their widespread use has led to extensive contamination, particularly in aquatic systems. Conventional treatment methods often face challenges such as high energy consumption and the production of secondary pollutants. Metal− organic frameworks (MOFs), with their high surface areas and tunable structures, have emerged as promising materials for PFAS remediation. This review summarizes recent progress in MOF-based PFAS adsorption and degradation, highlighting key frameworks such as MIL, UiO, and ZIF. Mechanistic insights into adsorption behavior and regeneration capabilities are discussed, along with the catalytic performance of MOF composites and postmodified systems in degradation pathways. The review concludes with design strategies for next-generation MOF materials aimed at efficient, sustainable PFAS removal under realistic conditions.

Adsorption↗