Search NASA⌕ Search

SEARCH · Search NASA

Results for “Root cause analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ground observations of a space laser for the assessment of its in-orbit performance

The wind mission Aeolus of the European Space Agency was a groundbreaking achievement for Earth observation. Between 2018 and 2023, the space-borne lidar instrument ALADIN onboard the Aeolus satellite measured atmospheric wind profiles with global coverage, which contributed to improving the accuracy of numerical weather prediction. The precision of the wind observations, however, declined over the course of the mission due to a progressive loss of the atmospheric backscatter signal. The analysis of the root cause was supported by the Pierre Auger Observatory in Argentina whose fluorescence detector registered the ultraviolet laser pulses emitted from the instrument in space, thereby offering an estimation of the laser energy at the exit of the instrument for several days in 2019, 2020, and 2021. The reconstruction of the laser beam not only allowed for an independent assessment of the Aeolus performance, but also helped to improve the accuracy in the determination of the laser beam’s ground track on single pulse level. The results presented in this paper set a precedent for the monitoring of space lasers by ground-based telescopes and open new possibilities for the calibration of cosmic-ray observatories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helios High Altitude Long Endurance Mission Mishap

This slide presentation reviews the failure of the Helios solar aircraft failure. Included are pictures of the aircraft, inflight, and after the mishap, analysis of the root causes of the mishap, contributing factors, recommendations and lessons learned in respect to crew training, and assessing the level of risk.

Henwood, Barton E.↗

Space Shuttle Stiffener Ring Foam Failure Analysis, a Non-Conventional Approach

The Space Shuttle Program made use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications de-bond, classical methods of failure analysis did not provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.

cryogenic tank insulation↗

Space Shuttle Stiffener Ring Foam Failure Analysis, a Non-Conventional Approach.

The Space Shuttle Program made use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications de-bond, classical methods of failure analysis did not provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.

Foam↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

5 Inch Thick 2219-T87 Plate Low Ductility Investigation - Material Analysis on Broken 2219 Tensile Samples

2219-T87 material used on a LOX tank baffle support on Artemis-I showed unusually low fracture elongation. Recent material data indicated 5” thick 2219-T87 plate stock had very low ductility (<1%) in the short transverse direction at the half-thickness location. Metallurgical analysis performed to understand the root cause that led to the drastic reduction in tensile ductility. The PowerPoint report details the key findings from material analysis by optical and scanning electron microscopy.

aluminum alloy 2219↗

Requirements Engineering Scorecard and the Next-Generation Space Suit

The objective for a NASA contractor, the performing organization in this case study, is to provide engineering services to develop and deliver the next generation space suit to NASA, the customer in this case study. A case study with qualitative and quantitative analyses regarding a new process and approach to requirements engineering is described, with the intent that if utilized, these tools may have contributed to improvements across the project in terms of meeting cost, scope, budget and quality while appropriately accounting for risk management. The procedure entails a research method in which the current state of the project, current state of the art, and the identified systems engineering challenges are evaluated. Iterative models are tempered through development by continual improvements by engineering evaluation of engineers on the project. The current results have produced a prototype of a requirements engineering scorecard with implementations of FMEA and quantitative analysis to (i) identify root cause of underdeveloped requirements and (ii) project management impacts with regards to project risk. Forward work includes customer, performing organization, acceptance against applicable INCOSE community accepted practices.

INCOSE↗

JPL/NASA/IEEE Test Effectiveness Workshop

(none given)From OBJECTIVES: Specific objectives of the working group are to support the innovation, development, evaluation and implementation of test methods, metrics and tools based on failure engineering/physics and/or root cause evaluations. Data sources systems and tools shall be developed and implemented that: 1) provide improved preventions, controls, analyses and tests (PACT) & field failure data collection, 2) facilities data analysis, archiving, retrieval, failure physics and/or root cause evaluations and 3) enable new and existing technology suitability evaluations to be performed.

effectiveness concurrent engineering metrics test ↗

Space Shuttle Stiffener Ring Foam Failure, a Non-Conventional Approach

The Space Shuttle makes use of the excellent properties of rigid polyurethane foam for cryogenic tank insulation and as structural protection on the solid rocket boosters. When foam applications debond, classical methods of analysis do not always provide root cause of the failure of the foam. Realizing that foam is the ideal media to document and preserve its own mode of failure, thin sectioning was seen as a logical approach for foam failure analysis. Thin sectioning in two directions, both horizontal and vertical to the application, was chosen to observe the three dimensional morphology of the foam cells. The cell foam morphology provided a much greater understanding of the failure modes than previously achieved.

Howard, Philip M.↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pendulum Motion in Main Parachute Clusters

The coupled dynamics of a cluster of parachutes to a payload are notoriously difficult to predict. Often the payload is designed to be insensitive to the range of attitude and rates that might occur, but spacecraft generally do not have the mass and volume budgeted for this robust of a design. The National Aeronautics and Space Administration (NASA) Orion Capsule Parachute Assembly System (CPAS) implements a cluster of three mains for landing. During testing of the Engineering Development Unit (EDU) design, it was discovered that with a cluster of two mains (a fault tolerance required for human rating) the capsule coupled to the parachute cluster could get into a limit cycle pendulum motion which would exceed the spacecraft landing capability. This pendulum phenomenon could not be predicted with the existing models and simulations. A three phased effort has been undertaken to understand the consequence of the pendulum motion observed, and explore potential design changes that would mitigate this phenomenon. This paper will review the early analysis that was performed of the pendulum motion observed during EDU testing, summarize the analysis ongoing to understand the root cause of the pendulum phenomenon, and discuss the modeling and testing that is being pursued to identify design changes that would mitigate the risk.

Ray, Eric S.↗

Report of the Odyssey FPGA Independent Assessment Team

An independent assessment team (IAT) was formed and met on April 2, 2001, at Lockheed Martin in Denver, Colorado, to aid in understanding a technical issue for the Mars Odyssey spacecraft scheduled for launch on April 7, 2001. An RP1280A field-programmable gate array (FPGA) from a lot of parts common to the SIRTF, Odyssey, and Genesis missions had failed on a SIRTF printed circuit board. A second FPGA from an earlier Odyssey circuit board was also known to have failed and was also included in the analysis by the IAT. Observations indicated an abnormally high failure rate for flight RP1280A devices (the first flight lot produced using this flow) at Lockheed Martin and the causes of these failures were not determined. Standard failure analysis techniques were applied to these parts, however, additional diagnostic techniques unique for devices of this class were not used, and the parts were prematurely submitted to a destructive physical analysis, making a determination of the root cause of failure difficult. Any of several potential failure scenarios may have caused these failures, including electrostatic discharge, electrical overstress, manufacturing defects, board design errors, board manufacturing errors, FPGA design errors, or programmer errors. Several of these mechanisms would have relatively benign consequences for disposition of the parts currently installed on boards in the Odyssey spacecraft if established as the root cause of failure. However, other potential failure mechanisms could have more dire consequences. As there is no simple way to determine the likely failure mechanisms with reasonable confidence before Odyssey launch, it is not possible for the IAT to recommend a disposition for the other parts on boards in the Odyssey spacecraft based on sound engineering principles.

Mayer, Donald C.↗

Ground Operations Autonomous Control and Integrated Health Management

An intelligent autonomous control capability has been developed and is currently being validated in ground cryogenic fluid management operations. The capability embodies a physical architecture consistent with typical launch infrastructure and control systems, augmented by a higher level autonomous control (AC) system enabled to make knowledge-based decisions. The AC system is supported by an integrated system health management (ISHM) capability that detects anomalies, diagnoses causes, determines effects, and could predict future anomalies. AC is implemented using the concept of programmed sequences that could be considered to be building blocks of more generic mission plans. A sequence is a series of steps, and each executes actions once conditions for the step are met (e.g. desired temperatures or fluid state are achieved). For autonomous capability, conditions must consider also health management outcomes, as they will determine whether or not an action is executed, or how an action may be executed, or if an alternative action is executed instead. Aside from health, higher level objectives can also drive how a mission is carried out. The capability was developed using the G2 software environment (www.gensym.com) augmented by a NASA Toolkit that significantly shortens time to deployment. G2 is a commercial product to develop intelligent applications. It is fully object oriented. The core of the capability is a Domain Model of the system where all elements of the system are represented as objects (sensors, instruments, components, pipes, etc.). Reasoning and decision making can be done with all elements in the domain model. The toolkit also enables implementation of failure modes and effects analysis (FMEA), which are represented as root cause trees. FMEA's are programmed graphically, they are reusable, as they address generic FMEA referring to classes of subsystems or objects and their functional relationships. User interfaces for integrated awareness by operators have been created.

Figueroa, Fernando↗

Strain energy-based fatigue failure analyses of LB-PBF Inconel 718: Effect of build orientation

Additively manufactured Inconel 718 parts fabricated in three build orientations (horizontal, vertical, and angled at 45 degrees) are tested in fully-reversed bending fatigue mode. Damping measurements via the Impulse Excitation technique are used to assess the defects content in the microstructure and fractography analysis is performed to detect the root cause of failure. Two micro- and macro-scale methodologies of fatigue damage estimation based on the dissipated heat per cycle and the statistical estimation of micro-plastic strain energies are used to assess fatigue damage. It is shown that at a given stress level, the vertically built specimens endure the most fatigue damage before failure while the diagonally built ones sustain the least. As a result, the fatigue life is estimated for arbitrary load amplitudes via a microstructure-sensitive algorithm with acceptable accuracy as compared to the experiments.

36 MATERIALS SCIENCE↗