Search NASASearch

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )

The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.

crystal growth

Scintillator based nuclear photovoltaic batteries for power generation at microwatts level

A nuclear photovoltaic battery uses scintillator to convert radiation into visible light, which is then collected by a photovoltaic (PV) cell to generate electricity. If the radiation is gamma-rays emitted from external sources, the battery may also be referred as gammavoltaic battery. In this study, a polycrystalline CdTe solar cell was optically coupled with a 2.0 cm × 2.0 cm × 1.0 cm Gadolinium Aluminum Gallium Garnet (GAGG) scintillator, and the resulting device was tested using intense gamma radiation fields from a Cs-137 (1.5 kRad/h) and a Co-60 (10 kRad/h) irradiator. Measurements with Cs-137 provided a maximum power output (P max ) of ~288 nW, with a short-circuit current density (J sc ) of ~1.22 μA/cm 2 and an open-circuit voltage (V oc ) of ~0.34 V. In contrast, Co-60 irradiator gave a P max of 1.5 μW, with a J sc of ~4.73 μA/cm 2 and a V oc of ~0.38 V. The CdTe was also paired with a Lutetium-Yttrium Oxyorthosilicate (LYSO) crystal and tested with the Cs-137 source. The experiment presents a scalable option to reach to higher power outputs by harvesting gamma radiation fields in many cases where high radiation field demands heavy shielding and is often regarded as unwanted waste.

25 ENERGY STORAGE

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing

Design, construction, and operation of a 1-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based liquid scintillators (WbLS) are a new class of detector materials that provide efficient and tunable detection of both Cherenkov and scintillation light. A massive WbLS neutrino detector with suitable photosensor coverage for low intensity light detection could therefore reconstruct the momentum of an energetic charged particle and also have enhanced low-energy sensitivity. These materials are also better suited for metal doping broadening the potential scientific utility. Here, we recently constructed and commissioned a 1-ton WbLS detector with good photosensor coverage and a capable data acquisition and calibration system. We intend to use this flexible detector system as a testbed for WbLS R&D. In this paper we give an overview of the 1-ton system and provide some early results.

47 OTHER INSTRUMENTATION

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.

42 ENGINEERING

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Measurement of the light yield response of the Gd-compatible water-based liquid scintillator with the Brookhaven one-ton testbed

The water-based liquid scintillator (WbLS) enables hybrid detection by combining scintillation and Cherenkov signals, providing superior event reconstruction capabilities compared to conventional neutrino detectors. For this work, we measured the light yield of Gd-compatible WbLS at varying concentrations from 0.35% to 1% by mass, using cosmic-ray muons in a 1-ton scale detector at Brookhaven National Laboratory. The light yield is measured as (69.2 ± 6.9) ph/MeV at 0.35% concentration, which increased to (87.3 ± 8.7) ph/MeV at 1%. These results establish a quantitative basis for optimizing future WbLS-based detectors in neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

First measurement of the yield of 8 He isotopes produced in liquid scintillator by cosmic-ray muons at Daya Bay

Here, Daya Bay presents the first measurement of cosmogenic 8 He isotope production in liquid scintillator, using an innovative method for identifying cascade decays of 8 He and its child isotope, 8 Li. We also measure the production yield of 9 Li isotopes using well-established methodology. The results, in units of 10 –8 μ –1 ⁢g –1 cm 2 , are 0.307 ± 0.042, 0.341 ± 0.040, and 0.546 ± 0.076 for 8 He, and 6.73 ± 0.73, 6.75 ± 0.70, and 13.74 ± 0.82 for 9 Li at average muon energies of 63.9 GeV, 64.7 GeV, and 143.0 GeV, respectively. The measured production rate of 8 He isotopes is more than an order of magnitude lower than any other measurement of cosmogenic isotope production. It replaces the results of previous attempts to determine the ratio of 8 He to 9 Li production that yielded a wide range of limits from 0% to 30%. The results provide future liquid-scintillator-based experiments with improved ability to predict cosmogenic backgrounds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng

Systematic study of radioluminescence and light propagation effects in scintillating nanoguide materials

Nanoguide optical waveguides are thermally processed materials based on polymers that have different refractive indices. Scintillating versions of these materials have been under development since 2019 and feature PMMA as the low refractive index constituent and Organic Glass Scintillator-polymer blends as the high index component. Characterization efforts to date have focused on the functional characteristics of nanoguide pertaining to its envisioned use in high-resolution transmission radiography applications.

36 MATERIALS SCIENCE

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng

Compounds and composition for preparation of lithium-loaded plastic scintillators

A scintillator material includes a polymer matrix, a primary dye in the polymer matrix, the primary dye being a fluorescent dye; a secondary dye, and a Li-containing compound in the polymer matrix, where the Li-containing compound is a Li salt of a short-chain aliphatic acid. In addition, the scintillator material exhibits an optical response signature for thermal neutrons that is different than an optical response signature for fast neutrons.

Zaitseva, Natalia P.

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]

From Detector Layout to Signal Analysis: Geometry Optimization and Neutron-Gamma Tagging in Plastic Scintillator Detectors

Neutrinos are elementary particles with many properties still unknown. Their masses so far have only upper and lower limits. Still, due to neutrino oscillations, it is clear that they are not massless, as stated by the Standard Model of Elementary Particles. Neutrinos are also present in the Universe in vast amounts, but they rarely interact with the surrounding matter. Their abundance makes them very interesting for many theories beyond the Standard Model, e.g., dark matter searches and CP symmetry violation in the leptonic sector, which could be (partially) responsible for the observed matter-antimatter asymmetry in today's Universe.\\ The Deep Underground Neutrino Experiment (DUNE) is a next-generation accelerator-based neutrino oscillation experiment that will study neutrinos with unprecedented precision and may answer many open questions. DUNE uses a powerful neutrino beam from Fermilab. It consists of a Near Detector (ND) complex to measure neutrinos before oscillat ion, and a Far Detector (FD) complex $1300\ \mathrm{km}$ away to measure them after oscillation. As part of the ND complex, measurements are also possible with different angles to the neutrino beam. This enables excellent control of systematic uncertainties of e.g., neutrino cross section measurements.\\ One detector in the near detector complex is The Muon Spectrometer (TMS), an extension of a Liquid Argon (LAr) detector that measures the charge and momentum of muons produced in neutrino interactions within the LAr. The design of this detector, which consists of alternating layers of steel and plastic scintillator bars, must be optimized for the expected muon energies.\\ In this thesis, a study of the optimal module orientation plan is presented, which is necessary for the physics performance of the near detector complex and, by extension, DUNE. As part of this study, the event reconstruction was also developed and improved. Simulated muons are then reconstructed, and the performan ce of different module orientation plans is tested.\\ As a second part, a study of neutron and gamma tagging using a Pulse Shape Discriminating (PSD) plastic scintillator is presented. The properties of this material allow particle differentiation based on the temporal distribution of emitted light. A novel approach to using the individual light signals was successfully tested using data from a small, local test setup.

Nehm, Asa [Mainz U.]

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND