Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The CLAS12 Forward Time-of-Flight system

The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7.2 m from the beam–target interaction point and spans laboratory polar angles from 5 deg → 45 deg and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. We see the effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of background limitations to ultra-sensitive $\mathrm{LSC}$ counting through $\mathrm{ICP}$-$\mathrm{MS}$ assay of $\mathrm{LSC}$ cocktails

We report the performance of LSC cocktails in ultra-sensitive applications was evaluated. Backgrounds from radioactive contaminations in commercially available and in-house developed liquid scintillation cocktails were measured and compared to the predicted background levels of the ultra-low background liquid scintillation counter. Through the ICP-MS assay of the cocktails and their constituents, potassium impurities in the surfactant component were identified as a significant source of background, potentially limiting the use of LSC counting in ultra-sensitive applications. This work lays the groundwork for future research towards ultrapure LSC cocktails for ultrasensitive LSC counting

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Temporal Characterization of Tritium Smear Activities

Tritium collection efficiency varies as a function of smear media. The use of porous smear materials leads to an increase in the measured tritium activity as a function of time when the measurement is performed with liquid scintillation counters. Operational inclusion of the efficiency differences and the time dependence of the tritium smear activity is necessary to preclude inadvertently releasing materials or areas. Thomas Jefferson National Laboratory Radiological Control Department identified a contaminated stainless steel containment vessel that previously housed a target containing more than 37 TBq of tritium. The item was systematically sectioned and surveyed to compare three smear types: water-wetted cotton swabs, water-wetted paper smears, and ethanol-wetted Styrofoam wipes (NUC-Wipes™). The total activity of each section was determined using repeated decontamination. The time dependence of the measured activity was also studied. The measured activity of both paper smears and cotton swabs showed significant time dependence. The cotton swabs also showed significantly reduced collection efficiency. Given the widespread use of both of these media in routine contamination surveys, site operational limits were derived using fitted curves for time dependence and average efficiency results. In conclusion, the use of these more restrictive limits allows for rapid measurement of tritium smears while ensuring regulatory compliance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mu2e - Extinction Monitor Research & Development

Current efforts are being conducted at Fermi National Laboratory to study potential violations in accepted theory that would otherwise suggest a restructuring of our fundamental understanding of the universe. Mu2e is one of these frontier projects that studies charged lepton flavor violation (CLFV) which if observed, would suggest physics beyond the Standard Model. Therefore, this note encompasses several projects that contribute to the fruition of Mu2e investigations. Due to the broad range of disciplinary inconsistencies that each project requires, all the work is being presented as a means of justifying contribution to Mu2e. The projects are comprised of a G4Beamline simulation analyzing 8GeV proton beam interaction with a titanium window of Recycler ring extinction rates using three Cherenkov radiation-based detectors and supplemental work for the implementation of a micro–Telecommunications Computing Architecture (MicroTCA) crate to establish a peak finding algorithm to ensure that the out-of-time beam is less than 10^-10 fractional level along with inefficiency analysis on scintillation counters for the Cosmic-Ray Veto (CRV) analysis. Preliminary results have been achieved for extinction rate simulation by achieving coincidence rates for 2/3-fold and 3/3-fold on the detectors in the order of 10^-9 and 10^-10, respectively. Only preliminary results of a triangular counter and four rectangular di-counters for the CRV have been realized but other non-experimental contributions were made to the development of the MicroTCA crate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent development in organic scintillators

Discussion on recent developments of organic scintillators includes studies of organic compounds that form glass-like masses which scintillate and are stable at room temperature, correlations between molecular structure of organic scintillators and self-quenching, recently developed fast scintillators, and applications of liquid-scintillation counters.

Horrocks, D. L.↗