Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The Analysis of Sulfur-35 as a Young Groundwater Tracer at E-Tunnel, Rainier Mesa, Nevada National Security Site

Analysis of the relatively short-lived radionuclide sulfur-35 (t 1/2 = 87 days) provides useful insight into groundwater discharge from E-Tunnel at the Nevada National Security Site (NNSS). Discharge rates at E-Tunnel vary with precipitation, potentially as the result of short or fast flowpaths between recharge and discharge. The presence of sulfur-35 in groundwater would indicate a significant component of young (< 2-year-old) groundwater. We collected two large volume (20 L) samples of discharge water in November 2016. The samples were sent to Lawrence Livermore National Laboratory (LLNL), where they were processed and analyzed by Liquid Scintillation Counting (LSC). Sulfur-35 was not detected in either the sample or field duplicate, a finding consistent with E-Tunnel discharge containing no significant component of groundwater with age less than six months.

54 ENVIRONMENTAL SCIENCES↗

Discriminator Threshold Study for Scint 1

During electronics testing at NSRL, the fluence/spill is recorded from the QC1 chamber. This chamber, which is a permanent fixture on the NSRL beamline, requires calibration from an external radiation detector that can measure ion flux directly. A 1.0 × 1.0 × 0.5 cm 3 scintillator is used at the testing location to calibrate all NSRL beams for electronic experiments. A calibration factor is derived by comparing the ions observed by the scintillator and QC1 during an exposure of at least 10 5 scintillator counts or total ions.

43 PARTICLE ACCELERATORS↗

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand

One simple and effective method for selective sulfate separation from aqueous solutions by crystallization with a bis-guanidinium ligand, 1,4-benzene-bis(iminoguanidinium) (BBIG), is demonstrated. The ligand is synthesized as the chloride salt (BBIG-Cl) by in situ imine condensation of terephthalaldehyde with aminoguanidinium chloride in water, followed by crystallization as the sulfate salt (BBIG-SO4). Alternatively, BBIG-Cl is synthesized ex situ in larger scale from ethanol. Furthermore, the sulfate separation ability of the BBIG ligand is demonstrated by selective and quantitative crystallization of sulfate from seawater. These ligands can then be recycled by neutralization of BBIG-SO4 with aqueous NaOH and crystallization of the neutral bis-iminoguanidine, which can be converted back into BBIG-Cl with aqueous HCl and reused in another separation cycle. Finally, 35S-labeled sulfate and β liquid scintillation counting are employed for monitoring the sulfate concentration in solution. Overall, this protocol will instruct the user in the necessary skills to synthesize a ligand, employ it in the selective crystallization of sulfate from aqueous solutions, and quantify the separation efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simple, rapid method for the preparation of isotopically labeled formaldehyde

Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Tc(IV)-Incorporated Fe Minerals to Enhance 99Tc Retention in Glass Waste Form

Iron minerals have been considered to be good hosts for Tc immobilization because the Tc(IV) ion substitutes for Fe(III) in the crystal structure of the Fe oxide due to similarities in (1) cation size [Tc(IV) = 78.5 pm ; Fe(III) = 69 or 78.5 pm], (2) metal-oxygen interatomic distance (Tc—O = 0.199 nm, Fe—O = 0.203 nm), (3) number of coordinating oxygen atoms (both 6-fold coordinated), and (4) the redox potential (Eh=ca. +20 mV at pH = 7) for a redox couple between Tc(VII)/Tc(IV) and Fe(III)/Fe(II). Magnetite, maghemite, and trevorite are iron oxide minerals and all belong to spinel mineral group. Laboratory testing shows that Tc can be removed from aqueous waste solutions by a process of Tc reduction from Tc(VII) to Tc(IV) followed by co-precipitation with iron oxide minerals during recrystallization of Fe(OH)2(s) used as an initial solid precursor. X-ray absorption near edge structure (XANES) spectroscopy confirmed that Tc was in the +4 oxidation state in final Tc-Fe minerals. The Tc-incorporated Fe minerals were also tested for Tc retention in glass melts at different temperatures between 600 – 1,000 oC in a furnace. After being cooled in air, the solid glass specimens collected at different temperatures were analyzed for Tc oxidation state using XANES and Tc retention using liquid scintillation counting (LSC). Even though Tc(IV) started to reoxidize at 600 oC, Tc retention in the final glass specimen prepared with Tc-incorporated Fe mineral even at high temperatures was at least two times higher than glass prepared with KTcO4 salt. Higher Tc retention in glass is considered to result from limited and delayed Tc volatilization process due to Fe mineral encapsulation for Tc. Therefore, the results showing the presence of Tc(IV) in the Fe mineral structure indicate strong possibility to enhance Tc retention in borosilicate glass as well as to reduce the remediation costs at the Hanford Site.

Environmental Molecular Sciences Laboratory↗

Colloidal Behavior of Plutonium Oxide in Concentrated Electrolyte Solutions

The Hanford Site in Washington State manages legacy high-level radioactive waste streams that display major chemistry and engineering challenges, including the high salt levels and pH values that correspond to conditions under which many classical concepts describing chemical reactivity cannot be applied. One particular challenge that needs to be tackled at Hanford is that Pu concentrations, [Pu], in the soluble phases of the tank wastes are higher than expected based on the solubility of crystalline PuO2, which is widely accepted to be caused by the formation of PuO2 colloid, consisting of nano- to submicron-sized particles (PuO2 NPs). Fundamental research underpinning the behavior of PuO2 NPs under conditions not only relevant to the Hanford tank waste but at high ionic strength in general is needed to reliably predict the chemical reactivity of PuO2 NPs and develop engineering solutions to safely and efficiently process high-level radioactive waste into forms suitable for long-term storage. In this work, we study the behavior of PuO2 NPs (particle size ~100 nm) under high ionic strength conditions by reacting it with highly concentrated (up to 5 M) salt solutions. We explore different electrolyte compositions to elucidate the impact of different anions (NO3-, Cl-, ClO4-, SO42-, C2O42-, CO32-) on the stability of PuO2 NP in the acidic and alkaline pH regime. PuO2 NP aggregation and precipitation as function electrolyte concentration is tracked by a combination of liquid scintillation counting, dynamic light scattering for determination of particle size distributions, and zeta potentials as a proxy for particle charge. At acidic pH, electrolytes containing non-coordinating anions, such as NaNO3, NaCl, and NaClO4 mostly stabilize PuO2 NPs over a large electrolyte concentration range, showing only subtle differences in their reactivity. Other electrolyte anions show a more pronounced effect on the PuO2 NP stability: SO42-, binds directly to the particles’ surface, reverses the particle charge, and precipitates the PuO2 NPs efficiently even at intermediate sulfate concentrations (>0.1 M). In contrast, C2O42- is found to lead to high [Pu] in solution, in the milli-molar range, even at mildly acidic pH (~4). Thermodynamic modeling of the dissolved Pu concentrations using PHREEQC is unable to predict the observed [Pu] in the acidic pH regime, supporting the influence of colloids in maintaining elevated [Pu]. It is noteworthy that the current thermodynamic databases do not include constants for colloidal Pu phases and cannot accurately predict many of the high ionic strength solutions relevant to this work. The mechanisms and models responsible for these observations will need further investigation in the future. At high pH values (~12), PuO2 NPs exhibits classical sol-gel chemistry, meaning that upon destabilization of the colloidal sol, for example by addition of concentrated NaOH, highly porous and viscid PuO2 coagulates are formed that consist of a three-dimensional network likely held together by physical interactions. The PuO2 NP coagulate shows no significant reversibility of the aggregation when contacted with concentrated brines; however, PuO2 NPs can be efficiently resuspended in solution by addition of diluted electrolytes, alkaline solutions containing high amounts of carbonate, or simple addition of water. Especially carbonate is shown to stabilize PuO2 NPs in solution at high pH, characterized by stable colloidal suspensions that are resistant against sedimentation during centrifugation. Thermodynamic modeling of the carbonate system was able to predict an increasing dissolved Pu concentration with increasing carbonate concentration. However, the model was profoundly sensitive to the fixed redox potential and does not include any thermodynamic constants for colloidal Pu species.

Neumann, Julia↗

Passive neutron coincidence counting with plastic scintillators for the characterization of radioactive waste drums

The quantification of radioactive material is essential in the fields of safeguards, criticality control of nuclear processes, dismantling of nuclear facilities and components, or radioactive waste characterization. The Nuclear Measurement Laboratory (LMN) of CEA is involved in the development of time-correlated neutron detection techniques using plastic scintillators. Usually, 3He proportional counters are used for passive neutron coincidence counting owing to their high thermal neutron capture efficiency and gamma insensitivity. However, the global {sup 3}He shortage in the past few years has made these detectors extremely expensive. In addition, contrary to {sup 3}He counters for which a few tens of microseconds are needed to thermalize fast neutrons, in view to maximize the {sup 3}He(n,p){sup 3}H capture cross section, plastic scintillators are based on elastic scattering and therefore the light signal is formed within a few nanoseconds, correlated pulses being detected within a few dozen- or hundred nanoseconds. This time span reflects fission particles time of flight, which allows reducing accordingly the duration of the coincidence gate and thus the rate of random coincidences, which may totally blind fission coincidences when using {sup 3}He counters in case of a high (α,n) reaction rate. However, plastic scintillators are very sensitive to gamma rays, requiring the use of a thick metallic shield to reduce the corresponding background. Cross talk between detectors is also a major issue, which consists on the detection of one particle by several detectors due to elastic or inelastic scattering, leading to true but undesired coincidences. Data analysis algorithms are tested to minimize cross-talk in simultaneously activated detectors. The distinction between useful fission coincidences and the correlated background due to cross-talk, (α,n) and induced (n,2n) or (n,n'γ) reactions, is achieved by measuring 3-fold coincidences. The performances of a passive neutron coincidence counting system for radioactive waste drums using plastic scintillators have been studied using the Monte Carlo radiation transport code MCNPX-PoliMi v2.0 coupled to data processing algorithms developed with ROOT data analysis software. In addition to the correlated background, accidental coincidences are taken into account in the simulation by randomly merging pulses from different calculations with fission and (α,n) sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing time decay of bibenzyl scintillator using time correlated single photon counting

The time decay of several scintillation materials has been measured using the time correlated single photon counting method and a new organic crystal with a highly suppressed delayed light has been identified. Results comparing the light decay of the bibenzyl crystal with a xylene based detector, which is currently installed at National Ignition Facility will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗