Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 mGy, respectively. The GE Discovery delivers about the same amount of dose (43.7 mGy) when run under similar operating and image-reconstruction conditions, i.e., without tube current modulation and ASIR. The image-metrics analysis likewise showed that the MTF, NPS, and CNR associated with the reconstructed images are mutually comparable when the three scanners are run with similar settings, and differences can be attributed to different edge-enhancement properties of the applied reconstruction filters. Moreover, when the GE scanner was operated with the facility's scanner settings for routine head exams, which apply 50% ASIR and use only approximately half of the 100%-FBP dose, the CNR of the images showed no significant change. Even though the CNR alone is not sufficient to characterize the image quality and justify any dose reduction claims, it can be useful as a constancy test metric.Conclusions: This work presents a straightforward method to connect direct measurements of CT dose with objective image metrics such as high-contrast resolution, noise, and CNR. It demonstrates that OSLD measurements in an anthropomorphic head phantom allow a realistic and locally precise estimation of magnitude and spatial distribution of dose in tissue delivered during a typical CT head scan. Additional objective analysis of the images of the ACR accreditation phantom can be used to relate the measured doses to high contrast resolution, noise, and CNR.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimized multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.

60 APPLIED LIFE SCIENCES↗

X-ray diffraction, differential scanning calorimetry and evolved gas analysis of aged plutonium tetrafluoride (PuF4)

A 30 year-old PuF4 sample consisting of brown powder (PuF4-b) and pink granules (PuF4-p) was analyzed. X-ray difraction shows the bulk is comprised of three compounds: PuF4, PuO2, and PuF4·1.6H2O. Broadening of PuF4 XRD peaks suggests possible a-damage. After annealing at 650 °C, crystalline PuF4 and PuO2 remain. Thermogravimetric analysis and diferential scanning calorimetry—with simultaneous evolved gas analysis—of the separated PuF4-p and PuF4-b components reveal a distinct sequence of reactions. Dehydration occurs between~90 and 300 °C. Exothermic annealing of the a-damage occurs in two stages: at 350–355 °C and at 555–558 °C. Hydrofuoric acid, fuorine and helium desorb during the frst exotherm. Above 700 °C, PuF4 reacts with PuO2, resulting in oxygen release and mass loss.

PuF4, dsc, differential scanning calorimetry, plut↗

Investigating Fast Scanning Calorimetry and Differential Scanning Calorimetry as Screening Tools for Thermoset Polymer Material Compatibility with Laser-Based Powder Bed Fusion

As additive manufacturing (AM) technology has developed and progressed, a constant topic of research in the area is expanding the library of materials to be used with these techniques. Among AM methods that utilize polymers, laser-based powder bed fusion (PBF-LB) has preferentially used thermoplastic polymers as its starting materials, but the deposition and material joining method employed in PBF-LB may also be compatible with powdered thermoset polymer precursors as feedstocks. To assess the compatibility of candidate thermosetting polymers and PBF-LB, characterization techniques and protocols that link fundamental material behavior to material behavior in the processing environment are needed. Therefore, the objectives of this work are to compare the curing behavior measured with two different calorimetry techniques that can operate in different heating rate regimes, differential scanning calorimetry (DSC) and fast scanning calorimetry (FSC), and to assess the capabilities of these techniques to act as materials screening tools for PBF-LB. A commercial polyester powder coating is used as a model material to evaluate the potential of obtaining complimentary information for material screening through a combination of calorimetry methods, and its non-isothermal curing behavior is measured at heating rates between 5 °C/min and 7500 °C/min. Curing exotherms are observed with both calorimetry techniques, and comparing the enthalpy associated with curing shows that incomplete curing occurs at higher heating rates, with relative conversion values of approximately 30%. The curing data are fit with two isoconversional models, Friedman and Starink, which show a reduced activation energy at higher heating rates as well, signifying a lower barrier to curing at the conditions used in the FSC experiments. Overall, the results of this work indicate that using these two calorimetry techniques as tiered screening tools can provide valuable information about how curing may proceed in PBF-LB and inform materials selection and design activities for additive manufacturing.

36 MATERIALS SCIENCE↗

Iron on GaN(0001) pseudo-1 × 1 (1+1/(12) ) investigated by scanning tunneling microscopy and first-principles theory

We have investigated sub-monolayer iron deposition on atomically smooth GaN(0001) pseudo-1 × 1 (1+1/(12) ). The iron is deposited at a substrate temperature of 360 °C, upon which reflection high energy electron diffraction shows a transformation to a √(3)×√(3)-R30° pattern. After cooling to room temperature, the pattern transforms to a 6 × 6, and scanning tunneling microscopy reveals 6 × 6 reconstructed regions decorating the GaN step edges. First-principles theoretical calculations have been carried out for a range of possible structural models, one of the best being a Ga dimer model consisting of 2/9 monolayer of Fe incorporated into 7/3 monolayer of Ga in a relaxed but distorted structure.

36 MATERIALS SCIENCE↗

Characterization of one-dimensional molecular chains of 4,4′-biphenyl diisocyanide on Au(111) by scanning tunneling microscopy

The morphology and electronic structure of vapor deposited 4,4′-biphenyldiisocyanide (BPDI) on a Au(111) surface were investigated using variable-temperature scanning tunneling microscopy. When deposited at room temperature, BPDI molecules form one-dimensional molecular chains similar to that recently observed for the structurally related 1,4-phenyl diisocyanide (PDI). Compared to PDI, the longer periodicity for the BPDI molecular chains is consistent with the addition of a second phenyl ring and supports a structural model in which the BPDI molecules lie parallel to the surface and interconnected by Au-adatoms. The molecular chains are mostly aligned along the [11{sup -}0] direction of the Au(111) substrate, but exhibit frequent changes in angle that are consistent with directions between fcc and hcp three-fold hollow sites. Dispersion-corrected density functional theory calculations for one-dimensional chains of BPDI molecules bound end-to-end via their isocyanide groups to Au-adatoms reproduce the observed periodicity of the chains and show that this morphology is energetically favored over upright binding with one free —NC group. The spatially resolved conductance (dI/dV) map for BPDI on Au(111) exhibits a feature centered at −0.67 eV below the Fermi level which are delocalized along the chain with maxima at the Au-adatom and biphenyl positions. This occupied resonant feature is close to that previously observed for the PDI in both photoemission and conductance measurements and is attributed to an occupied interfacial state resulting from BPDI-Au interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolution in Carrier Profiling Semiconductors by Scanning Spreading Resistance Microscopy and Scanning Frequency Comb Microscopy

High resolution measurements of the carrier profile in semiconductor devices is required as the semiconductor industry progresses from the 10-nm lithography node to 7-nm and beyond. We examine the factors which determine the resolution of the present method of scanning spreading resistance microscopy as well as such factors for the newer method of scanning frequency comb microscopy that is now under development. Also, for the first time, we consider the sensitivity of both methods to the location of heterogeneities in the semiconductor. In addition, mesoscopic effects on these measurements are considered for the first time. Two simple analytical models are extended to study the sensitivity to heterogeneities as well as mesoscopic effects.

36 MATERIALS SCIENCE↗

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning probe microscope simulator for the assessment of noise in scanning probe microscopy controllers

We present an electronic circuit that allows to calibrate and troubleshoot scanning probe microscopy (SPM) controllers with respect to their noise performance. The control signal in an SPM is typically highly nonlinear—the tunneling current in scanning tunneling microscopy (STM) varies exponentially with distance. The exponential current-versus-voltage characteristics of diodes allow to model the current dependence in STM. Additional inputs allow to simulate the effects of external perturbations and the reactions of the control electronics. We characterized the noise performance of the feedback controller using the apparent topography roughness of recorded images. For a comparison of different STM controllers, an optimal gain parameter was determined by exploring settling times through a rectangular perturbation signal. We used the circuit to directly compare the performance of two types of SPM controllers used in our laboratory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the limits of Si:P δ -doped devices patterned by a scanning tunneling microscope in a field-emission mode

Recently, a single atom transistor was deterministically fabricated using phosphorus in Si by H-desorption lithography with a scanning tunneling microscope (STM). This milestone in precision, achieved by operating the STM in the conventional tunneling mode, typically utilizes slow (∼102 nm2/s) patterning speeds. By contrast, using the STM in a high-voltage (>10 V) field-emission mode, patterning speeds can be increased by orders of magnitude to ≳104 nm2/s. We show that the rapid patterning negligibly affects the functionality of relatively large micron-sized features, which act as contacting pads for these devices. For nanoscale structures, we show that the resulting electrical transport is consistent with the donor incorporation chemistry constraining the electrical dimensions to a scale of 10 nm even though the pattering spot size is 40 nm.

Rudolph, M.↗

Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detecting element specific electrons from a single cobalt nanocluster with synchrotron x-ray scanning tunneling microscopy

Here, we use a nanofabricated scanning tunneling microscope tip as a detector to investigate local X-ray induced tunneling and electron emission from a single cobalt nanocluster on a Au(111) surface. The tip-detector is positioned a few angstroms above the nanocluster, and ramping the incident X-ray energy across the Co photoabsorption K-edge enables the detection of element specific electrons. Atomic-scale spatial dependent changes in the X-ray absorption cross section are directly measured by taking the X-ray induced current as a function of X-ray energy. From the measured sample and tip currents, element specific X-ray induced current components can be separated and thereby the corresponding yields for the X-ray induced processes of the single cobalt nanocluster can be determined. The detection of element specific synchrotron X-ray induced electrons of a single nanocluster opens a new avenue for materials characterization on a one particle at-a-time basis.

36 MATERIALS SCIENCE↗

In situ laser processing in a scanning electron microscope

Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

36 MATERIALS SCIENCE↗

Self port scanning tool : providing a more secure computing Environment through the use of proactive port scanning

Secure computing is a necessity in the hostile environment that the internet has become. Protection from nefarious individuals and organizations requires a solution that is more a methodology than a one time fix. One aspect of this methodology is having the knowledge of which network ports a computer has open to the world, These network ports are essentially the doorways from the internet into the computer. An assessment method which uses the nmap software to scan ports has been developed to aid System Administrators (SAs) with analysis of open ports on their system(s). Additionally, baselines for several operating systems have been developed so that SAs can compare their open ports to a baseline for a given operating system. Further, the tool is deployed on a website where SAs and Users can request a port scan of their computer. The results are then emailed to the requestor. This tool aids Users, SAs, and security professionals by providing an overall picture of what services are running, what ports are open, potential trojan programs or backdoors, and what ports can be closed.

nMap↗

Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy

Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique. Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc{sub multi-field}) and the standard robust optimized intensity modulated proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds. Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc{sub multi-field} plans. Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement Error in Atomic-Scale Scanning Transmission Electron Microscopy—Energy-Dispersive X-Ray Spectroscopy (STEM-EDS) Mapping of a Model Oxide Interface

Abstract With the development of affordable aberration correctors, analytical scanning transmission electron microscopy (STEM) studies of complex interfaces can now be conducted at high spatial resolution at laboratories worldwide. Energy-dispersive X-ray spectroscopy (EDS) in particular has grown in popularity, as it enables elemental mapping over a wide range of ionization energies. However, the interpretation of atomically resolved data is greatly complicated by beam–sample interactions that are often overlooked by novice users. Here we describe the practical factors—namely, sample thickness and the choice of ionization edge—that affect the quantification of a model perovskite oxide interface. Our measurements of the same sample, in regions of different thickness, indicate that interface profiles can vary by as much as 2–5 unit cells, depending on the spectral feature. This finding is supported by multislice simulations, which reveal that on-axis maps of even perfectly abrupt interfaces exhibit significant delocalization. Quantification of thicker samples is further complicated by channeling to heavier sites across the interface, as well as an increased signal background. We show that extreme care must be taken to prepare samples to minimize channeling effects and argue that it may not be possible to extract atomically resolved information from many chemical maps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗