Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Light-induced shift current vortex crystals in moiré heterobilayers

Transition metal dichalcogenide (TMD) moiré superlattices provide an emerging platform to explore various light-induced phenomena. Recently, the discoveries of novel moiré excitons have attracted great interest. The nonlinear optical responses of these systems are however still underexplored. Here, we report investigation of light-induced shift currents (a second-order response generating DC current from optical illumination) in the WSe 2 /WS 2 moiré superlattice. We identify a striking phenomenon of the formation of shift current vortex crystals—i.e., two-dimensional periodic arrays of moiré-scale current vortices and associated magnetic fields with remarkable intensity under laboratory laser setup. Furthermore, we demonstrate high optical tunability of these current vortices—their location, shape, chirality, and magnitude can be tuned by the frequency, polarization, and intensity of the incident light. Electron-hole interactions (excitonic effects) are found to play a crucial role in the generation and nature of the shift current intensity and distribution. Our findings provide a promising all-optical control route to manipulate nanoscale shift current density distributions and magnetic field patterns, as well as shed light on nonlinear optical responses in moiré quantum matter and their possible applications.

36 MATERIALS SCIENCE↗

Individual Nest Site Preferences Do Not Explain Upslope Population Shifts of a Secondary Cavity-Nesting Species

Geographic ranges of plants and animals are shifting due to environmental change. While some species are shifting towards the poles and upslope in elevation, the processes leading to these patterns are not well known. We analyzed 22 years of western bluebird (Sialia mexicana) data from a large nest box network in northern New Mexico at elevations between 1860 m and 2750 m. This population has shifted to higher elevations over time, but whether this is due to changes in nesting behavior and preference for higher elevation within the population or driven by immigration is unclear. We banded adults and nestlings from nest boxes and examined nesting location and elevation for individual birds captured two or more times. Most recaptured birds nested at the same nest boxes in subsequent years, and the number of birds that moved upslope did not significantly differ from the number that moved downslope. Fledglings moved greater distances and elevations than adults, but these movements were not upslope specific. Female fledglings showed greater changes in elevation and distance compared to male fledglings, but again, movements were not consistently upslope. The upslope shift in this population may be due to birds immigrating into the population and not from changes in individual nesting behavior.

59 BASIC BIOLOGICAL SCIENCES↗

Broad Frequency Shift of Parametric Processes in Epsilon-Near-Zero Time-Varying Media

The ultrafast changes of material properties induced by short laser pulses can lead to a frequency shift of reflected and transmitted radiation. Recent reports highlight how such a frequency shift is enhanced in spectral regions where the material features a near-zero real part of the permittivity. Here, we investigate the frequency shift for fields generated by four-wave mixing. In our experiment, we observed a frequency shift of more than 60 nm (compared to the pulse width of ~40 nm) in the phase conjugated radiation generated by a 500 nm aluminium-doped zinc oxide (AZO) film pumped close to the epsilon-near-zero wavelength. Our results indicate applications of time-varying media for nonlinear optics and frequency conversion.

36 MATERIALS SCIENCE↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Automated Shift Detection in Sensor-Based PV Power and Irradiance Time Series

PV power and irradiance sensor-based measurements are prone to error, resulting in issues such as time series data shifts. In this research, a changepoint detection (CPD) algorithm that automatically detects data shifts in sensor-based time series is introduced. Data shift periods in 101 daily PV power and irradiance time series were labeled manually by two solar experts. These data streams represent sensor-based measurements, and display a variety of data shift behaviors. A changepoint detection algorithm was tuned using the 101 labeled data streams, with each model configuration's ability to detect labeled changepoints benchmarked using metrics such as F1-score, recall, and Rand Index. Best performing models on seasonality-corrected data streams include the Pruned Exact Linear (PELT) method, the Binary Segmentation method, and the Bottom-Up method, all scoring an average F1-score of 0.76 or greater at detecting labeled changepoints within a 30-day window across the labeled data sets. Pending approval, we plan to release the labeled data sets for this research on NREL's DuraMAT Data Hub, and the associated algorithm in the Python PVAnalytics package. By supplying the training sets and algorithm, we hope to encourage further development in this research space.

data shift↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Survey of Time Shift Detection Algorithms for Measured PV Data

In this research, three variations of time shift detection algorithms were tested for their ability to detect time shift issues (including daylight savings time and random time shifts) in measured PV data sets. Two algorithms from the Python PVAnalytics package were assessed, and one algorithm from the Solar-Data-Tools package was assessed. Each algorithm's ability to accurately detect and measure time shifts was assessed.

automated preprocessing↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theory of the tertiary instability and the Dimits shift within a scalar model

The Dimits shift is the shift between the threshold of the drift-wave primary instability and the actual onset of turbulent transport in a magnetized plasma. It is generally attributed to the suppression of turbulence by zonal flows, but developing a more detailed understanding calls for consideration of specific reduced models. The modified Terry–Horton system has been proposed by St-Onge ( J. Plasma Phys. , vol. 83, 2017, 905830504) as a minimal model capturing the Dimits shift. Here, we use this model to develop an analytic theory of the Dimits shift and a related theory of the tertiary instability of zonal flows. We show that tertiary modes are localized near extrema of the zonal velocity $U(x)$ , where $x$ is the radial coordinate. By approximating $U(x)$ with a parabola, we derive the tertiary-instability growth rate using two different methods and show that the tertiary instability is essentially the primary drift-wave instability modified by the local $U'' \doteq {\rm d}^2 U/{\rm d} x^2 $ . Then, depending on $U''$ , the tertiary instability can be suppressed or unleashed. The former corresponds to the case when zonal flows are strong enough to suppress turbulence (Dimits regime), while the latter corresponds to the case when zonal flows are unstable and turbulence develops. This understanding is different from the traditional paradigm that turbulence is controlled by the flow shear $| {\rm d} U / {\rm d} x |$ . Our analytic predictions are in agreement with direct numerical simulations of the modified Terry–Horton system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

General Protocol for the Accurate Prediction of Molecular 13 C/ 1 H NMR Chemical Shifts via Machine Learning Augmented DFT

An accurate prediction of NMR chemical shifts at affordable computational cost is very important for different types of structural assignments in experimental studies. Density functional theory (DFT) and gauge-including atomic orbital (GIAO) are two of the most popular computational methods for NMR calculation, yet they often fail to resolve ambiguities in structural assignments. In this work, we present a new method that uses machine learning (ML) techniques (DFT + ML) that significantly increases the accuracy of 13 C/ 1 H NMR chemical shift prediction for a variety of organic molecules. The input of the generalizable DFT + ML model contains two critical parts: one is a vector providing insights into chemical environments, which can be evaluated without knowing the exact geometry of the molecule; the other one is the DFT-calculated isotropic shielding constant. The DFT + ML model was trained with a data set containing 476 13 C and 270 1 H experimental chemical shifts. For the DFT methods used here, the root mean square deviations (RMSDs) for the errors between predicted and experimental 13 C/ 1 H chemical shifts can be as small as 2.10/0.18 ppm, which is much lower than those from simple DFT (5.54/0.25 ppm), or DFT + linear regression (LR) (4.77/0.23 ppm) approaches. It also has a smaller maximum absolute error than two previously proposed NMR-predicting ML models. The robustness of the DFT + ML model is tested on two classes of organic molecules (TIC10 and hyacinthacines), where the correct isomers were unambiguously assigned to the experimental ones. Overall, the DFT + ML model shows promise for structural assignments in a variety of systems, including stereoisomers, that are often challenging to determine experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intramolecular Polarization Contributions to the pKa’s of Carboxylic Acids Through the Chain Length Dependence of Vibrational Tag-Shifts in Cryogenically Cooled Pyridinium-(CH2)n-COOH (n = 1-7) Cations

The pKa’s of acids are known to depend on the ionic strength of an electrolyte solution, an effect that qualitatively results from electrostatic interactions of the acid and conjugate base with proximal ions. Here we explore an intramolecular variation on this theme in which a carboxylic acid group is tethered to a pyridinium cationic charge center with increasingly long alkyl linkages in the series Py+-(CH2)n-COOH, with n = 1-7. The effective acidities of the carboxylic acid group in the isolated cations are determined by recording the red-shifts in the frequencies of the acid OH stretches upon attachment to D2 and N2 molecules, measured by using cryogenic ion spectroscopy. The short chains indeed lead to substantial increases in acidity, with the effect falling off in the range of n = 4-5. The response of the CO stretch on the acid head group is surprisingly strong and, in contrast to the expected red shift of the OH, displays a blue shift as the chain length is reduced. Electronic structure calculations recover these trends and indicate that the proximal cationic charge center acts to draw electron density away from the acid C=O bond. This acts to blue shift the CO stretch while weakening the C-C bond that attaches the head group to the chain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding Anomalous Gas-Phase Peak Shifts in Dip-and-Pull Ambient Pressure XPS Experiments

Dip-and-pull ambient pressure X-ray photoelectron spectroscopy (AP-XPS) holds promise to uncover elementary processes of (photo)electrochemistry. We show, however, that the sample for such experiments should preferably be nonporous and the potential on the surface homogeneous. We carried out dip-and-pull AP-XPS experiments on a hematite thin film sample under the photoelectrochemical oxygen evolution reaction (OER) and find unexpected O 1s core level shifts. Upon electrochemical biasing under simulated solar light illumination, the gas-phase water peak shifted more than the electrolyte peak. To uncover the origin of the unexpected larger shift of the gas-phase peak, we performed electrostatic simulations using COMSOL, to map the potential field in the relevant volume between the sample and the first aperture of the XPS spectrometer. A number of geometric models were considered. We find that when the potential on the sample surface is inhomogeneous, e.g., with ionically isolated electrolyte patches, the gas-phase peak of the spectrum can shift more than the peak due to the electrolyte film. This suggests that at the measured sample position, the local potential was not as set by the potentiostat. Despite this, we find reversible consumption and replenishment of hydroxide in the spectra, which, due to OH– being the reactant of the OER in alkaline electrolyte, makes sense chemically. We propose that this is linked to OH– diffusion across the measured sample position, driven by the potential dependent consumption and replenishment of OH– at the nearby well-connected surface regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hyperspectral Detection of the Fluorescence Shift between Chirality-Sorted Empty and Water-Filled Single-Wall Carbon Nanotube Enantiomers

Single-wall carbon nanotubes (SWCNTs) have extraordinary electronic and optical properties that depend strongly on their exact chiral structure and their interaction with their inner and outer environment. The fluorescence (PL) of semiconducting SWCNTs, for instance, will shift depending on the molecules with which the SWCNT’s hollow core is filled. These interaction-induced shifts are challenging to resolve on the ensemble level in samples containing a mixture of different filling contents due to the relatively large inhomogeneous line width of the ensemble SWCNT PL compared to the size of these shifts. To circumvent this inhomogeneous broadening, single-tube spectroscopy and hyperspectral imaging are often applied, which until now required time-consuming statistical studies. Here, we present hyperspectral PL microscopy combined with automated SWCNT segmenting based on either principal component analysis or a convolutional neural network, capable of both spatially and spectrally resolving the PL along the length of many individual SWCNTs at the same time and automatically fitting peak positions and line widths of individual SWCNTs. The methodology is demonstrated by accurately determining the emission shifts and line widths of thousands of left- and right-handed empty and water-filled SWCNTs coated with a chiral surfactant, resulting in four statistical distributions which cannot be resolved in ensemble spectroscopy of unsorted samples. The results demonstrate a robust method to quickly probe ensemble properties with single-enantiomer spectral resolution. Moreover, it promises to be an absolute quantitative method to characterize the relative abundances of SWCNTs with different handedness or filling content in macroscopic samples, simply by counting individual species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Suppression of ITG turbulence due to spectral shift during biasing induced H-mode on HBT-EP

Investigations of biasing induced H-mode discharges on HBT-EP show that the edge turbulence is consistent with the ion temperature gradient) mode and have allowed for the controlled observation of the effect of applied flow shear on the turbulence. Measurements of the radial wavenumber spectrum of floating potentials at the edge show that the turbulence intensity decreases with increasing shift in the spectrum average ⟨ k r ⟩ when increasing amounts of bias probe voltage (and increasing amounts of flow shear) is applied. This is in agreement with the spectral shift model [Staebler et al., Phys. Rev. Lett. 110, 055003 2013] for turbulence suppression via sheared flow. A shift in the wavenumber spectrum occurs at applied electrode voltages and currents below the threshold needed for an L–H transition, and a dithering transition is obtained when biasing near the threshold. Suppression of blob-filament turbulence in the scrape-off layer (SOL) precedes the L–H transition, with the SOL turbulence remaining low throughout the dithering phase, despite the modulation of turbulence levels in the nearby edge. This demonstrates that the SOL turbulence “decouples” from the edge turbulence. The spectral shift in the measured radial wavenumber is corroborated by the direct measurement of eddy tilt angle using a novel time delay analysis technique first developed for Doppler reflectometry [Pinzon et al., Plasma Phys. Controlled Fusion 61, 105009 (2019)] but adapted here for floating potential measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Giant exciton-enhanced shift currents and direct current conduction with subbandgap photo excitations produced by many-electron interactions

Significance Shift current, a bulk photovoltaic effect, arises from nonlinear light–matter interaction in a noncentrosymmetric crystal under continuous wave illumination. Although it is a promising mechanism for photocurrent generation without p–n junctions, the short-circuit current (which is related to the power efficiency of a solar cell device) is usually low. It is therefore important to understand the physics of the phenomenon and find materials with strong shift current conductivity. We calculate the shift current conductivity including excitonic effects in a real material (monolayer GeS) from first principles. We show that electron–hole interactions can dramatically enhance and qualitatively change shift current in reduced-dimensional materials. Our results indicate low-dimensional materials are promising candidates for next-generation photovoltaic devices with high efficiencies.

Chan, Yang-Hao↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Distinct microbiomes underlie divergent responses of methane emissions from diverse wetland soils to oxygen shifts

Abstract Hydrological shifts in wetlands, a globally important methane (CH4) source, are critical constraints on CH4 emissions and carbon-climate feedbacks. A limited understanding of how hydrologically driven oxygen (O2) variability affects microbial CH4 cycling in diverse wetlands makes wetland CH4 emissions uncertain. Transient O2 exposure significantly stimulated anoxic CH4 production in incubations of Sphagnum peat from a temperate bog by enriching for polyphenol oxidizers and polysaccharide degraders, enhancing substrate flow toward methanogenesis under subsequent anoxic conditions. To assess whether shifts in soil microbiome structure and function operate similarly across wetland types, here we examined the sensitivity of different wetland soils to transient oxygenation. In slurry incubations of Sphagnum peat from a minerotrophic fen, and sediments from a freshwater marsh and saltmarsh, we examined temporal shifts in microbiomes coupled with geochemical characterization of slurries and incubation headspaces. Oxygenation did not affect microbiome structure and anoxic CH4 production in mineral-rich fen-origin peat and freshwater marsh soils. Key taxa linked to O2-stimulated CH4 production in the bog-origin peat were notably rare in the fen-origin peat, supporting microbiome structure as a primary determinant of wetland response to O2 shifts. In contrast to freshwater wetland experiments, saltmarsh geochemistry—particularly pH—and microbiome structure were persistently and significantly altered postoxygenation, albeit with no significant impact on greenhouse gas emissions. These divergent responses suggest wetlands may be differentially resistant to O2 fluctuations. With climate change driving greater O2 variability in wetlands, our results inform mechanisms of wetland resistance and highlight microbiome structure as a potential resiliency biomarker.

Reji, Linta (ORCID:0000000213376782)↗

Line confusion in spectroscopic surveys and its possible effects: shifts in Baryon Acoustic Oscillations position

ABSTRACT Roman Space Telescope will survey about 17 million emission-line galaxies over a range of redshifts. Its main targets are Hα emission-line galaxies at low redshifts (z < 2) and [O iii] emission-line galaxies at high redshifts (z > 2). The Roman Space Telescope will estimate the redshift of these galaxies with single-line identification. This suggests that other emission-line galaxies may be misidentified as the main targets. In particular, it is hard to distinguish between the H β and [O iii] lines as the two lines are close in wavelength and hence the photometric information may not be sufficient to separate them reliably. Misidentifying H β emitter as [O iii] emitter will cause a shift in the inferred radial position of the galaxy by approximately 90 Mpc h−1. This length-scale is similar to the Baryon Acoustic Oscillation (BAO) scale and could shift and broaden the BAO peak, possibly introduce errors in determining the BAO peak position. We qualitatively describe the effect of this new systematic and further quantify it with a light-cone simulation with emission-line galaxies. Our results show a systematic shift in the recovered isotropic BAO positions that depends on the percentage of interlopers (percentage of ${\rm H}\,\beta$) in the sample. The systematic shift can be as large as $0.1{-}0.3\,\mathrm{ per}\,\mathrm{ cent} \, {\rm x}\, {{\%}}{\rm H}\,\beta$ for analysis performed at redshifts z = 1.3−1.9.

79 ASTRONOMY AND ASTROPHYSICS↗