Search NASA⌕ Search

SEARCH · Search NASA

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Cohort Study of Multiple Brain Lesions in Sport Divers: Role of a Patent Foramen Ovale

To investigate the role of a patent foramen ovale in the pathogenesis of multiple brain lesions acquired by sport divers in the absence of reported decompression symptoms. Design: Prospective double blind cohort study. . Setting Diving clubs around Heidelberg and departments of neuroradiology and neurology. Subjects: 87 sport divers with a minimum of 160 scuba dives (dives with self contained underwater breathing apparatus). Main outcome measures: Presence of multiple brain lesions visualised by cranial magnetic resonance imaging and presence and size of patent foramen ovale as documented by echocontrast transcranial Doppler ultrasonogra~hy. Results: 25 subjects were found to have a right-to-left shunt, 13 with a patent foramen ovale of high haemodynamic relevance. A total of 41 brain lesions were detected in 11 divers. There were seven brain lesions in seven divers without a right-to-left shunt and 34 lesions in four divers with a right-to-left shunt Multiple brain lesions occurred exclusively in three divers with a large patent foramen ovale (P=0.004). Conclusions: Multiple brain lesions in sport divers were associated with presence of a large patent foramen ovale. This association suggests paradoxical gas embolism as the pathological mechanism. A patent foramen ovale of high haemodynamic relevance seems to be an important risk factor for developing multiple brain lesions in sport divers.

Knauth, Michael↗

Transesophageal Echocardiography and Contrast-TCD in the Detection of a Patent Foramen Ovale: Experience with 111 Patients

Patent foramen ovale (PFO) is increasingly recognized in association with cryptogenic stroke. Using transesophageal echocardiography (TEE) and transcranial Doppler sonography with ultrasonic contrast medium contrast-(TCD), we evaluated the frequency of a PFO as the fundamental condition of paradoxical embolism in 111 patients after cerebral ischemia. There was a right-left shunt in 50 patients (45%) with TEE. In 31 of 40 patients with stroke of unknown etiology, a PFO was the only detectable finding associated with cerebral ischemia. Using TEE as he "gold standard," the sensitivity of contrast-TCD was 91.3%, specificity 93.8%, and the overall accuracy 92.8%. contrast-TCD failed to detect a right-left shunt in four patients, but there were four other patients with negative TEE and positive contrast-TCD. We conclude that contrast-TCD is a highly sensitive method for detecting a right-left shunt. Its advantages are low cost, its ability to detect single contrast-medium embolism, and control of the Valsalva maneuver by observing the decrease of cerebral blood flow. Evidence of PFO in cryptogenic stroke should prompt a search for a subclinical venous thrombosis as the embolic source.

Klotzsch, Christof↗

Device and Method for Continuously Equalizing the Charge State of Lithium Ion Battery Cells

A method of equalizing charge states of individual cells in a battery includes measuring a previous cell voltage for each cell, measuring a previous shunt current for each cell, calculating, based on the previous cell voltage and the previous shunt current, an adjusted cell voltage for each cell, determining a lowest adjusted cell voltage from among the calculated adjusted cell voltages, and calculating a new shunt current for each cell.

Schwartz, Paul D.↗

Quantitative decoding of coupled carbon and energy metabolism in Pseudomonas putida for lignin carbon utilization

Soil Pseudomonas species, which thrive on lignin derivatives, are widely explored for biotechnology applications in lignin valorization. However, how the native metabolism coordinates phenolic carbon processing with required cofactor generation remains poorly understood. Here, we achieve quantitative understanding of this metabolic balance through a detailed multi-omics investigation of Pseudomonas putida KT2440 grown on four common phenolic acid substrates: ferulate, p-coumarate, vanillate, and 4-hydroxybenzoate. Relative to succinate, proteomics reveals > 140-fold increase in transport and catabolic proteins for aromatics, but metabolomics identifies bottlenecks in initial catabolism to maintain favorable cellular energy charge, which is compromised in mutants with resolved bottlenecks. Up to 30-fold increase in pyruvate carboxylase and glyoxylate shunt proteins implies a metabolic remodeling confirmed by kinetic 13 C-metabolomics. Quantitative analysis by 13 C-fluxomics demonstrates coupling of this remodeling with cofactor production. Specifically, anaplerotic carbon recycling through pyruvate carboxylase promotes tricarboxylic acid cycle fluxes to generate 50-60% NADPH yield and 60-80% NADH yield, resulting in up to 6-fold greater ATP surplus than with succinate metabolism; the glyoxylate shunt sustains cataplerotic flux through malic enzyme for the remaining NADPH yield. This quantitative blueprint affords cofactor imbalance predictions in proposed engineering of key metabolic nodes in lignin valorization pathways.

09 BIOMASS FUELS↗

Transport signatures of phase fluctuations in superconducting qubits

Abstract Josephson junctions supply the nonlinear inductance element in superconducting qubits. In the widely used transmon configuration, where the junction is shunted by a large capacitor, the low charging energy minimizes the sensitivity of the qubit to charge noise while maintaining the necessary anharmonicity to qubit states. We report here low-frequency transport measurements on small standalone junctions and identically fabricated capacitively-shunted junctions that show two distinct features normally attributed to small capacitance junctions near zero bias: reduced switching currents and prominent finite resistance associated with phase diffusion in the current–voltage characteristic. Our transport data reveals the existence of phase fluctuations in transmons arising from intrinsic junction capacitance.

Wisne, M. (ORCID:0009000610684209)↗

Junction characteristics of silicon solar cells. Part 1: Nonilluminated case

Precise values of the reverse saturation currents in silicon solar cells and magnitudes of the diffusion and recombination components have been obtained. The recombination current as well as leakage current due to shunting are shown to be nonuniform across the cell. The diffusion lengths calculated from the diffusion current components agree well with diffusion lengths measured independently in similar material. Models are given demonstrating the effect of recombination and shunting currents on the dark current-voltage characteristics of solar cells.

Stirn, R. J.↗

Junction characteristics of silicon solar cells.

Precise values of the reverse saturation currents in solar cells and magnitudes of the diffusion and recombination components have been obtained. The recombination current as well as leakage current due to shunting are shown to be nonuniform across the cell and to be responsible for up to 30% loss in efficiency for the average cell in a Jupiter-type environment. Models are given demonstrating the effect of recombination and shunting currents on dark and light characteristics of solar cells.

Stirn, R. J.↗

The Atmosphere Explorer power subsystem

The present work describes the design and in-flight performance of the power subsystem for the first three Atmosphere Explorer (AE) spacecraft. The subsystem provides all electrical power to the spacecraft loads and consists of a solar array, three batteries, and a power supply electronics unit. Power from the solar array is supplied to the spacecraft loads through an unregulated power bus, which varies between -26 and -38 V. Loads which are normally on only during data collection phases of an orbit are fed from a tightly regulated -24.5 V bus. Power subsystem performance during the first three months in orbit has been nominal, except for an anomally in the shunt limiter protection circuitry. A malfunctioning shunt control amplifier was reconnected via ground command.

Obenschain, A.↗

Gate-assisted turnoff thyristors

A study of the turnoff physics in gate-assisted turnoff thyristors (GATT's) leads to a proposed mechanism involving the gate bias acting to prevent a forward voltage from appearing on the cathode rather than, as was previously thought, to sweep out excess carriers. It is shown that cathode shunting can be used in GATT's to virtually eliminate an important failure mode and to decrease the gate voltage needed to produce the desired improvement in turnoff time. Implications for designing GATT's are given, one being that a change in the lateral resistance of the p-base will have opposite effects depending on whether the cathode is shunted or not.

Schlegel, E. S.↗

Storage effects on cells

The results of an experiment to test storage effects on electric cells of a battery are presented and discussed. The type of cells were the 20 amp-hour OAO type. The various modes that were tested were the integration type mode, the trickle charge, the discharge shorted and the discharged OCV (open current voltage). Every six months the cells were reconditioned and approximately two weeks of tests were performed. The tests included three capacity checks, two zero-degree overcharge tests and an internal short test (the cells are shunted for 16 hours, the shunt removed and allowed to stand on local circuit recovery for 24 hours). The integration pack was discontinued after three years and the trickle charge shorted packs after five years.

Harkness, J. M.↗

A redundant regulator control with low standby losses

Shunt regulator circuit for outer-planet-spacecraft radiosotope thermoelectric generator minimizes power-conditioning losses. Unit consists of bank of duplicate regulator control amplifiers and their associated shunt transistors connecter across power supply line. Its high-gain circuitry arranged in redundant configuration in very reliable and is characterized by low standby loss. Circuit can be used on other power-supply applications where size, weight, and reliability are important.

Andryczyk, R. W.↗

Development of low cost contacts to silicon solar cells

The results of the second phase of the program of developing low cost contacts to silicon solar cells using copper are presented. Phase 1 yielded the development of a plated Pd-Cr-Cu contact system. This process produced cells with shunting problems when they were heated to 400 C for 5 minutes. Means of stopping the identified copper diffusion which caused the shunting were investigated. A contact heat treatment study was conducted with Pd-Ag, Ci-Ag, Pd-Cu, Cu-Cr, and Ci-Ni-Cu. Nickel is shown to be an effective diffusion barrier to copper.

Tanner, D. P.↗

Error analysis in the measurement of average power with application to switching controllers

Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.

Maisel, J. E.↗

Hot-spot heating in central-station arrays

Hot spot tests performed on the Sacramento Municipal Utility District (SMUD) verificaton array show that current imbalance occurs, resulting in significant hot spot heating. One cause of current imbalance is differences in the average shunt resistances of parallel cell strings due to cell shunt resistance variations. In depth hot spot tests are performed on the verification array with bypass diodes. The tests had several objectives: (1) a comparison of hot spot temperatures achieved under field conditions with those obtained with the present laboratory hot spot test using similar modules; (2) an assessment of current imbalance versus cross tie frequency; and (3) an assessment of different shadow patterns and shadow densities. Instrumented modules are used to vary the number of cross ties and to measure the test-cell current and back-bias voltage. The widths, lengths, and densities of the shadows are varied to maximize the back bias voltage at maximum power current. An infrared camera is used to indicate the existence of hot spots and estimate temperature increases in conjunction with thermocouples. The results of these hot spot tests indicate a sensitivity of back bias heating to the shadow size (amount of cell coverage) and density.

Gonzalez, C. C.↗

Hot-spot heating susceptibility due to reverse bias operating conditions

Because of field experience (indicating that cell and module degradation could occur as a result of hot spot heating), a laboratory test was developed at JPL to determine hot spot susceptibility of modules. The initial hot spot testing work at JPL formed a foundation for the test development. Test parameters are selected as follows. For high shunt resistance cells, the applied back bias test current is set equal to the test cell current at maximum power. For low shunt resistance cells, the test current is set equal to the cell short circuit current. The shadow level is selected to conform to that which would lead to maximum back bias voltage under the appropriate test current level. The test voltage is determined by the bypass diode frequency. The test conditions are meant to simulate the thermal boundary conditions for 100 mW/sq cm, 40C ambient environment. The test lasts 100 hours. A key assumption made during the development of the test is that no current imbalance results from the connecting of multiparallel cell strings. Therefore, the test as originally developed was applicable for single string case only.

Gonzalez, C. C.↗

Modeling and simulation of spacecraft power systems

EASY5 modeling of a complete spacecraft power processing system is presented. Component models are developed, and several system models including a solar array switching system, a partially-shunted solar array system and COBE system are simulated. The power system's modes of operation, such as shunt mode, battery-charge mode, and battery-discharge mode, are simulated for a complete orbit cycle.

Lee, J. R.↗

Magnification of starting torques of dc motors by maximum power point trackers in photovoltaic systems

Direct current (dc) motors are used in terrestrial photovoltaic (PV) systems such as in water-pumping systems for irrigation and water supply. Direct current motors may also be used for space applications. Simple and low weight systems including dc motors may be of special interest in space where the motors are directly coupled to the solar cell array (with no storage). The system will operate only during times when sufficient insolation is available. An important performance characteristic of electric motors is the starting to rated torque ratio. Different types of dc motors have different starting torque ratios. These ratios are dictated by the size of solar cell array, and the developed motor torque may not be sufficient to overcome the load starting torque. By including a maximum power point tracker (MPPT) in the PV system, the starting to rated torque ratio will increase, the amount of which depends on the motor type. The starting torque ratio is calculated for the permanent magnet, series and shunt excited dc motors when powered by solar cell arrays for two cases: with and without MPPT's. Defining a motor torque magnification by the ratio of the motor torque with an MPPT to the motor torque without an MPPT, a magnification of 3 was obtained for the permanent magnet motor and a magnification of 7 for both the series and shunt motors. The effect of the variation of solar insolation on the motor starting torque was covered. All motor types are less sensitive to insolation variation in systems including MPPT's as compared to systems with MPPT's. The analysis of this paper will assist the PV system designed to determine whether or not to include an MPPT in the system for a specific motor type.

Appelbaum, Joseph↗

Experimental investigation into passive damping enhancement for space structures

This work presents experiments which were conducted to verify kinetic and strain energy damping enhancement schemes for large/precision space structures. Two types of damping mechanisms were applied to a 5 meter long, 10 bay aluminum box truss with a quasi free-free three-dimensional suspension. Tuneable proof mass dampers (PMDs) were implemented with space realizable linear electromechanical drivers. Tuneable piezoelectric truss members were designed and constructed for the demonstration of resonant shunted piezoelectric damping concepts. The truss damping was measured and compared to analytical predictions obtained from a frequency domain system modeling technique. The proof mass damper implementation was found to increase first mode damping from 0.6 percent of critical to 6.4 percent of critical with a system mass increase of 2.7 percent. The resonant shunted piezoelectrics increased first mode damping to 6.0 percent with a similar mass penalty.

Hagood, Nesbitt W.↗