Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Edge technique lidar for high accuracy, high spatial resolution wind measurement in the Planetary Boundary Layer

The goal of the Army Research Office (ARO) Geosciences Program is to measure the three dimensional wind field in the planetary boundary layer (PBL) over a measurement volume with a 50 meter spatial resolution and with measurement accuracies of the order of 20 cm/sec. The objective of this work is to develop and evaluate a high vertical resolution lidar experiment using the edge technique for high accuracy measurement of the atmospheric wind field to meet the ARO requirements. This experiment allows the powerful capabilities of the edge technique to be quantitatively evaluated. In the edge technique, a laser is located on the steep slope of a high resolution spectral filter. This produces large changes in measured signal for small Doppler shifts. A differential frequency technique renders the Doppler shift measurement insensitive to both laser and filter frequency jitter and drift. The measurement is also relatively insensitive to the laser spectral width for widths less than the width of the edge filter. Thus, the goal is to develop a system which will yield a substantial improvement in the state of the art of wind profile measurement in terms of both vertical resolution and accuracy and which will provide a unique capability for atmospheric wind studies.

Korb, C. L.↗

Heterodyne method for high specificity gas detection.

This paper describes a new technique for measuring trace quantities of gases. The technique involves the use of a reference cell (containing a known amount of the gas being sought) and a sample cell (containing an unknown amount of the same gas) wherein the gas densities are modulated. Light passing through the two cells in sequence is modulated in intensity at the vibrational-rotational lines characteristic of the absorption spectrum for the gas of interest. Since the absorption process is nonlinear, modulating the two absorption cells at two different frequencies gives rise to a heterodyning effect, which in turn introduces sum and difference frequencies in the detected signal. Measuring the ratio of the difference frequency signal for example, to the signal introduced by the reference cell provides a normalized measure of the amount of the gas in the sample cell. The readings produced are thereby independent of source intensity, window transparency, and detector sensitivity. Experimental evaluation of the technique suggests that it should be applicable to a wide range of gases, that it should be able to reject spurious signals due to unwanted gases, and that it should be sensitive to concentrations of the order of 10 to the minus 8th power when used with a sample cell of only 20 cm length.

Dimeff, J.↗

Quantification of Trace Chemicals Using Vehicle Cabin Atmosphere Monitor

A system to monitor the concentrations of trace chemicals in cabin atmosphere is one of the most critical components in long-duration human flight missions. The Vehicle Cabin Atmosphere Monitor (VCAM) is a miniature gas chromatograph mass spectrometer system to be used to detect and quantify trace chemicals in the International Space Station. We developed an autonomous computational process to quantify trace chemicals for use in VCAM. The process involves the design of a measured signal quantification scheme, the construction of concentration curves (i.e. the relationship between concentration and ion count measured by VCAM), the decision rule of applying high- or low-gain concentration curves, and the detection of saturation, low-signals, and outliers. When the developed quantification process is applied, the average errors of concentration for most of trace chemicals are found to be between 14% and 66%.

Lee, Seungwon↗

LaF3 infrared detector

A class of infrared detectors is proposed, and experimental results are presented for a prototype device. The material used is LaF3, an ionic conductor with a capacitance that varies exponentially with temperature. The detectivity of a prototype detector is estimated from measured signal voltages and incident power, and a Johnson noise voltage is calculated from the measured resistance. At a modulation frequency of 20 Hz, the estimated detectivity is about 2 million cm/sq root Hz/W. For the parameters characterizing this device, the estimated detectivity is consistent with a theoretical prediction. The theory further predicts an optimum detectivity of about 1 billion cm/sq root Hz/W for much thinner devices than the prototypes.

Sher, A.↗

Weak-Lensing Mass Calibration of the Atacama Cosmology Telescope Equatorial Sunyaev-Zeldovich Cluster Sample with the Canada-France-Hawaii Telescope Stripe 82 Survey

Mass calibration uncertainty is the largest systematic effect for using clustersof galaxies to constrain cosmological parameters. We present weak lensing mass measurements from the Canada-France-Hawaii Telescope Stripe 82 Survey for galaxy clusters selected through their high signal-to-noise thermal Sunyaev-Zeldovich (tSZ) signal measured with the Atacama Cosmology Telescope (ACT). For a sample of 9 ACT clusters with a tSZ signal-to-noise greater than five, the average weak lensing mass is (4.8 plus or minus 0.8) times 10 (sup 14) solar mass, consistent with the tSZ mass estimate of (4.7 plus or minus 1.0) times 10 (sup 14) solar mass, which assumes a universal pressure profile for the cluster gas. Our results are consistent with previous weak-lensing measurements of tSZ-detected clusters from the Planck satellite. When comparing our results, we estimate the Eddington bias correction for the sample intersection of Planck and weak-lensing clusters which was previously excluded.

Battaglia, N.↗

New technique for the direct measurement of core noise from aircraft engines

The core noise levels from gas turbine aircraft engines were measured using a technique which requires that fluctuating pressures be measured in the far field and at two locations within the engine core. The cross spectra of these measurements are used to determine the levels of the far-field noise that propagated from the engine vore. The technique makes it possible to measure core noise levels even when other noise sources dominate. The technique was applied to signals measured from an Avco Lycoming YF102 turbofan engine. Core noise levels as a function of frequency and radiation angle were measured and are presented over a range of power settings.

Krejsa, E. A.↗

New technique for the direct measurement of core noise from aircraft engines

A new technique is presented for directly measuring the core noise levels from gas turbine aircraft engines. The technique requires that fluctuating pressures be measured in the far-field and at two locations within the engine core. The cross-spectra of these measurements are used to determine the levels of the far-field noise that propagated from the engine core. The technique makes it possible to measure core noise levels even when other noise sources dominate. The technique was applied to signals measured from an AVCO Lycoming YF102 turbofan engine. Core noise levels as a function of frequency and radiation angle were measured and are presented over a range of power settings.

Krejsa, E. A.↗

Mass Spectrometric Studies of Oxides

Current studies at NASA Glenn on oxide thermodynamics are discussed. Previous studies on the vaporization of B2O3 in reducing atmospheres led to inconsistent studies when B was used as a reductant. It is shown that liquid B2O3 does not wet B and a clear phase separation was noted in the Knudsen cell. This problem was solved by using FeB and Fe2B to supply a different and constant activity of B. The thermodynamic data thus derived are compared to quantum chemical composite calculations. A major problem in high temperature mass spectrometry is the determination of accurate ionization cross sections, particularly for molecules. The method of Deutsch and Mark shows promise and some sample calculations are discussed. Finally current studies on the thermodynamics of rare earth silicates are discussed. Here the problems are obtaining a measurable signal from SiO2 vaporization and non-equilibrium vaporization. The use of a Ta reducing agent provides a stronger signal, which is related to silica activity. The Whitman-Motzfeld relation adapted to KEMS measurements is applied to obtain equilibrium pressures.

Jacobson, Nathan S.↗

Develop advanced nonlinear signal analysis topographical mapping system

The SSME has been undergoing extensive flight certification and developmental testing, which involves some 250 health monitoring measurements. Under the severe temperature pressure, and dynamic environments sustained during operation, numerous major component failures have occurred, resulting in extensive engine hardware damage and scheduling losses. To enhance SSME safety and reliability, detailed analysis and evaluation of the measurements signal are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce catastrophic system failure risks and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. The basic objective of this contract are threefold: (1) Develop and validate a hierarchy of innovative signal analysis techniques for nonlinear and nonstationary time-frequency analysis. Performance evaluation will be carried out through detailed analysis of extensive SSME static firing and flight data. These techniques will be incorporated into a fully automated system. (2) Develop an advanced nonlinear signal analysis topographical mapping system (ATMS) to generate a Compressed SSME TOPO Data Base (CSTDB). This ATMS system will convert tremendous amounts of complex vibration signals from the entire SSME test history into a bank of succinct image-like patterns while retaining all respective phase information. A high compression ratio can be achieved to allow the minimal storage requirement, while providing fast signature retrieval, pattern comparison, and identification capabilities. (3) Integrate the nonlinear correlation techniques into the CSTDB data base with compatible TOPO input data format. Such integrated ATMS system will provide the large test archives necessary for a quick signature comparison. This study will provide timely assessment of SSME component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. The final result of this program will yield an ATMS system of nonlinear and nonstationary spectral analysis software package integrated with the Compressed SSME TOPO Data Base (CSTDB) on the same platform. This system will allow NASA engineers to retrieve any unique defect signatures and trends associated with different failure modes and anomalous phenomena over the entire SSME test history across turbo pump families.

Jong, Jen-Yi↗

Optical Quantum Receiver For Binary Signals

In quantum optical receiver, both amplitude and phase of received optical signal measured to extract as much information as possible, thereby reducing error probability. Phase-modulated received signal mixed with equal amplitude replica of optical carrier generated in phase locked loop. Two signals interfere with each other at photomultiplier cathode. Probability of error with this scheme close to theoretical minimum and implemented with current technology.

Vilnrotter, V. A.↗

Statistical Signal Analysis for Systems with Interferenced Inputs

A new approach is introduced, based on statistical signal analysis, which overcomes the error due to input signal interference. The model analyzed is given. The input signals u sub 1 (t) and u sub 2 (t) are assumed to be unknown. The measurable signals x sub 1 (t) and x sub 2 (t) are interferened according to the frequency response functions, H sub 12 (f) and H sub 21 (f). The goal of the analysis was to evaluate the power output due to each input, u sub 1 (t) and u sub 2 (t), for the case where both are applied to the same time. In addition, all frequency response functions are calculated. The interferenced system is described by a set of five equations with six unknown functions. An IBM XT Personal Computer, which was interfaced with the FFT, was used to solve the set of equations. The software was tested on an electrical two-input, one-output system. The results were excellent. The research presented includes the analysis of the acoustic radiation from a rectangular plate with two force inputs and the sound pressure as an output signal.

Bai, R. M.↗

Small-signal gain diagnostic measurements in a flowing CO2 pin discharge laser

Small-signal gain diagnostic measurements were conducted on closed loop, high power, carbon dioxide laser to assess the coupling between gas flow velocity and resonator saturation. Parameters investigated included optical cavity and discharge power. Results of gain measurements within and downstream of the excitation volume are presented for a laser gas composition He:N2:CO2 of 10:7:1 at 90 torr. The gain at constant discharge power was observed to be dependent upon discharge power level and time. An important result of this study is that the effects of gain swept downstream of the discharge region must be considered in the resonator design if efficient extraction of stored optical energy is desired.

Blech, R. A.↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

Measurement of a surface heat flux and temperature

The Heat Flux Microsensor is a new sensor which was recently patented by Virginia Tech and is just starting to be marketed by Vatell Corp. The sensor is made using the thin-film microfabrication techniques directly on the material that is to be measured. It consists of several thin-film layers forming a differential thermopile across a thermal resistance layer. The measured heat flux q is proportional to the temperature difference across the resistance layer q= k(sub g)/delta(sub g) x (t(sub 1) - T(sub 2)), where k(sub g) is the thermal conductivity and delta (sub g) is the thickness of the thermal resistance layer. Because the gages are sputter coated directly onto the surface, their total thickness is less than 2 micrometers, which is two orders of magnitude thinner than previous gages. The resulting temperature difference across the thermal resistance layer (delta is less than 1 micrometer) is very small even at high heat fluxes. To generate a measurable signal many thermocouple pairs are put in series to form a differential thermopile. The combination of series thermocouple junctions and thin-film design creates a gage with very attractive characteristics. It is not only physically non-intrusive to the flow, but also causes minimal disruption of the surface temperature. Because it is so thin, the response time is less than 20 microsec. Consequently, the frequency response is flat from 0 to over 50 kHz. Moreover, the signal of the Heat Flux Microsensor is directly proportional to the heat flux. Therefore, it can easily be used in both steady and transient flows, and it measures both the steady and unsteady components of the surface heat flux. A version of the Heat Flux Microsensor has been developed to meet the harsh demands of combustion environments. These gages use platinum and platinum-10 percent rhodium as the thermoelectric materials. The thermal resistance layer is silicon monoxide and a protective coating of Al2O3 is deposited on top of the sensor. The superimposed thin-film pattern of all six layers is presented. The large pads are for connection with pins used to bring the signal out the back of the ceramic. In addition to the heat flux measurement, the surface temperature is measured with a platinum resistance layer (RTS). The resistance of this layer increases with increasing temperature. Therefore, these gages simultaneously measure the surface temperature and heat flux. The demonstrated applications include rocket nozzles, SCRAM jet engines, gas turbine engines, boiling heat transfer, flame experiments, basic fluid heat transfer, hypersonic flight, and shock tube testing. The laboratory involves using one of these sensors in a small combustion flame. The sensor is made on a 2.5 cm diameter piece of aluminum nitride ceramic.

Davis, R. M.↗

Lightning on Venus - Orbiter detection of whistler signals

Taylor et al. (1979) presented preliminary evidence for lightning on Venus, based on Pioneer Venus orbiter detection of whistler mode signals as the spacecraft first traversed the nightside ionosphere near periapsis. The initial periapsis eclipse season for the orbiter has been completed, and the plasma wave instrument obtained low-altitude nightside data for about 100 orbits. An analysis is presented of the impulsive whistler mode signals measured during these orbits, and the connection with atmospheric lightning is discussed. It is shown that the signals are detected in the 100-Hz channel when the local magnetic field is sufficiently strong and steady and when the field is oriented to point down below the ionosphere.

Scarf, F. L.↗

Sources of L-Band RFI Determined From Kurtosis Using the SMAP Radiometer

Among the parameters of the signal measured by the SMAP radiometer to identify RFI is kurtosis which indicates the departure of the received signal from a gaussian distribution and therefor helpful in identifying RFI. But the kurtosis has the potential to provide additional information. This manuscript reports results of an investigation examining the connection between the level of kurtosis (K) and the characteristics of the source of the RFI. It is shown, for example, that the level of can be used to distinguish the short pulse, relatively wideband RFI associated with radar from the narrow bandwidth signals associated with faulty consumer electronics.

Radio Frequency Interference↗

Noise-Contamination Detector

Deviations in periods of output from tracking filter measured. Signal-analyzing system measures degree to which sinusoid contaminated by noise. Noise-contamination detector indirectly measures noise in noisy sinusoidal signal by measuring average value of fractional absolute dither in period of signal. Developed to measure noise in outputs of vibration sensors used to test bearings and other components of rotating machinery.

Randall, Richard L.↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗