Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL TO NOISE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of Fuel Cladding Chemical Interaction on a High Burnup U-10Zr Metallic Fuel via Electron Energy Loss Spectroscopy Enhanced by Machine Learning

Fuel cladding chemical interaction (FCCI) is one of the main performance limiting factors for metallic nuclear fuels. The interaction destabilizes the martensitic microstructure and deteriorates mechanical properties of HT-9 cladding. The detection of low atomic number elements (Z<10) and overlapping of elemental peaks can be problematic in interpreting energy dispersive X-ray spectroscopy (EDS) data. Electron energy loss spectroscopy (EELS) provides precise elemental edge energy values and can detect elements with a low atomic number. This work utilizes EELS to study the distribution of lanthanides and light elements at the interaction region. The sample was prepared from the FCCI region of a U-10Zr (wt.%) solid fuel with HT-9 cladding, irradiated to a burnup of 13.2 at.%. Processing the EELS data included three major steps: 1) enhance the signal to noise ratio by denoising the spectrum with principal component analysis (PCA) method, removing background and performing deconvolution; 2) identify chemical elements with core energy loss edges; 3) confirm different phases using a popular machine learning method, K-means. This work presents qualitative assessment of lanthanides and light elements like carbon (C) and oxygen (O) enhanced by the application of machine learning algorithms. By comparing with EDS elemental maps, EELS provides higher resolution chemical maps, reveals the distribution of carbon at the interaction region supporting the formation of zirconium carbide, a rind-like microstructure feature that was proposed to mitigate the chemical interaction. Furthermore, the plasmon peak map was also found to indicate an energy shift associated with the formation of phases/compounds. K-means clustering method was used on the processed electron energy loss (EEL) spectrum to automatically reveal different phases. The resulting clustered maps from K-means clustering align well with elemental maps confirming certain phases, especially Fe-Ce and Zr-C, in the FCCI region.

EELS↗

Fast-RF-Shimming: Accelerate RF shimming in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) offers an elevated signal-to-noise ratio (SNR), enabling exceptionally high spatial resolution that benefits both clinical diagnostics and advanced research. However, the jump to higher fields introduces complications, particularly transmit radiofrequency (RF) field ($B^{+}_{1}$) inhomogeneities, manifesting as uneven flip angles and image intensity irregularities. These artifacts can degrade image quality and impede broader clinical adoption. Traditional RF shimming methods, such as Magnitude Least Squares (MLS) optimization, effectively mitigate $B^{+}_{1}$ inhomogeneity, but remain time-consuming. Recent machine learning approaches, including RF Shim Prediction by Iteratively Projected Ridge Regression and other deep learning architectures, suggest alternative pathways. Although these approaches show promise, challenges such as extensive training periods, limited network complexity, and practical data requirements persist. In this paper, we introduce a holistic learning-based framework called Fast-RF-Shimming, which achieves a 5000 ​× ​speed-up compared to the traditional MLS method. In the initial phase, we employ random-initialized Adaptive Moment Estimation (Adam) to derive the desired reference shimming weights from multi-channel $B^{+}_{1}$ fields. Next, we train a Residual Network (ResNet) to map $B^{+}_{1}$ fields directly to the ultimate RF shimming outputs, incorporating the confidence parameter into its loss function. Finally, we design Non-uniformity Field Detector (NFD), an optional post-processing step, to ensure the extreme non-uniform outcomes are identified. Comparative evaluations with standard MLS optimization underscore notable gains in both processing speed and predictive accuracy, which indicates that our technique shows a promising solution for addressing persistent inhomogeneity challenges.

Deep learning↗

Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel methodology for gamma-ray spectra dataset procurement over varying standoff distances and source activities

The adoption of machine learning approaches for gamma-ray spectroscopy has received considerable attention in the literature. Many studies have investigated the deployment of various algorithm architectures to a specific task. However, little attention has been afforded to the development of the datasets leveraged to train the models. Such training datasets typically span a set of environmental or detector parameters to encompass a problem space of interest to a user. Variations in these measurement parameters will also induce fluctuations in the detector response, including expected pile-up and ground scatter effects. Fundamental to this work is the understanding that 1) the underlying spectral shape varies as the measurement parameters change and 2) the statistical uncertainties associated with two spectra impact their level of similarity. While previous studies attribute some arbitrary discretization to the measurement parameters for the generation of their synthetic training data, this work introduces a principled methodology for efficient spectral-based discretization of a problem space. A signal-to-noise ratio (SNR) respective spectral comparison measure and a Gaussian Process Regression (GPR) model are used to predict the spectral similarity across a range of measurement parameters. This innovative approach effectively showcased its capability by dividing a problem space, ranging from 5 cm to 100 cm standoff distances and 5 μCi–100 μCi of 137 Cs, into three unique combinations of measurement parameters. The findings from this work will aid in creating more robust datasets, which incorporate many possible measurement scenarios, reduce the number of required experimental test set measurements, and possibly enable experimental training data collection for gamma-ray spectroscopy.

data science↗

Beam test results of the Intermediate Silicon Tracker for sPHENIX

The Intermediate Silicon Tracker (INTT), a two-layer barrel silicon strip tracker, is a key component of the tracking system for sPHENIX at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. The INTT is designed to enable the association of reconstructed tracks with individual RHIC bunch crossings. To evaluate the performance of preproduction INTT ladders and the readout chain, a beam test was conducted at the Research Center for Accelerator and Radioisotope Science, Tohoku University, Japan. This paper presents the performance of the INTT evaluated through studies of the signal-to-noise ratio, residual distribution, spatial resolution, hit-detection efficiency, and multiple track reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Convergent laser beam shapes: Unveiling the dynamics of Laser-induced elastic waves in composite materials

Overcoming the low signal-to-noise ratio (SNR) in laser ultrasonic testing of composite materials remains a significant challenge. Current efforts focus on enhancing SNR by inserting more energy into the material through temporal and/or spatial modulation of the laser beam. However, potential SNR improvements through wave convergence and wave energy manipulation have been overlooked. This paper addresses this gap by demonstrating the convergence of different wave types to a designated point and by showing the feasibility of directing absorbed laser energy into a specific wave type through spatial modulation of the laser beam. To achieve this, mathematical expressions for the convergent laser beams are derived. Various laser beam profiles are then introduced to the thermoelastic equations and solved using the finite element method. The sample under investigation is a transversely isotropic unidirectional carbon fiber reinforced plastic, characterized by anisotropic thermal expansion coefficients and thermal conductivities. Results reveal pronounced convergence of the intended wave type at the center due to laser beam shaping. This study showcases the ability to direct absorbed laser energy toward a specific wave type through spatial modulation of the laser beam and highlights the role of material anisotropy in energy focusing.

composite materials↗

Boosting Noise2Inverse via enhanced model selection for denoising computed tomography data

Synchrotron-based x-ray tomographic imaging enables the examination of the internal structure of materials at high spatial and temporal resolution. Experimental constraints can impose dose and time limits on the measurements, introducing a higher level of noise and artifacts in the reconstructed images. Deep learning has emerged as a powerful tool to remove noise from reconstructed images. Recently, the Noise2Inverse method was designed specifically for denoising reconstructed images without requiring paired noisy and clean images. This method creates multiple statistically independent reconstructions used to pair the data in which training involves transforming one reconstruction into the other, and vice versa. Originally designed to be used after a fixed number of epochs, we see in practice that this approach may not produce the optimal model and may unnecessarily waste computational resources. Therefore, we propose an alternative method of identifying the best model during training that aligns with the Noise2Inverse method. During validation, we compare the model output of the multiple reconstructions among each other. We hypothesize that the best model is the one that produces images with the highest similarity, implying a convergence in the predicted material properties and absorption values. To compare model outputs, we consider the absolute error, square error, structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and cosine similarity. We evaluate our method on two simulated tomography datasets and two, real-world, low-contrast, high-energy x-ray tomography datasets. We show our approach is more effective at determining the best model, up to an increase of 12.50% and 12.53% in SSIM and PSNR, respectively, while only requiring a fifth of the training time compared to the original approach.

CT↗

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Absorption Correction for Reliable Pair Distribution Functions from Low Energy X-ray Sources

This paper explores the development and testing of a simple absorption correction model for processing powder X-ray diffraction data from Debye−Scherrer geometry laboratory X-ray experiments. This may be used as a preprocessing step before using PDFGETX3 to obtain reliable pair distribution functions (PDFs). Various experimental and theoretical methods for estimating μR were explored, and the most appropriate μR values for correction were identified for different capillary diameters and X-ray beam sizes. We identify operational ranges of μR where a reasonable signal-to-noise ratio is possible after correction. A user-friendly software package, DIFFPY.LABPDFPROC, is presented that can help estimate μR and perform absorption corrections with a rapid calculation for efficient processing.

Absorption↗

Gate-Tunable Short-Wave Infrared Polycrystalline GeSn Phototransistors on Noncrystalline Substrates

GeSn is a group-IV alloy with immense potential to advance microelectronics technology due to its intrinsic compatibility with existing Si CMOS processes. With a sufficiently high Sn composition, GeSn is classified as a direct bandgap semiconductor. Polycrystalline GeSn holds several additional advantages, including its significantly lower synthesis cost compared to its epitaxial counterpart, as well as the versatility to grow these films on a variety of substrates. Here, in this work, we present a polycrystalline thin-film GeSn phototransistor on a fused silica substrate with a Sn composition of ~10%, showing a photoresponse in the short-wave infrared wavelength range, critical for emerging sensing applications. This device shows a gate-tunable response, with responsivities approaching up to 1.7 mA/W with only a 30 nm-thick GeSn layer. Furthermore, phototransistors offer additional adaptability through gating, which allows for the reduction of dark current. This not only enhances the signal-to-noise ratio but also offers more flexible integration with various image sensor readout implementations using different substrates. The specific detectivity of this phototransistor is within an order of magnitude of those of previously reported GeSn photodetectors grown by molecular beam epitaxy and chemical vapor deposition, even though the absorber is 3 to 20× thinner while the electrode spacing for photocarrier transport is approximately 15× longer than the carrier diffusion length in this work, showing great potential benefits of extending similar device structures to epitaxial GeSn layers. As these GeSn phototransistors utilize a noncrystalline substrate, our work establishes a fundamentally more versatile path toward monolithically integrated GeSn-based photodetectors for next-generation multimodal sensors.

36 MATERIALS SCIENCE↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

Covalent Drug Binding in Live Cells Monitored by Mid-Infrared Quantum Cascade Laser Spectroscopy: Photoactive Yellow Protein as a Model System

The detection of drug-target interactions in live cells enables analysis of therapeutic compounds in a native cellular environment. Recent advances in spectroscopy and molecular biology have facilitated the development of genetically encoded vibrational probes like nitriles that can sensitively report on molecular interactions. Nitriles are powerful tools for measuring electrostatic environments within condensed media like proteins, but such measurements in live cells have been hindered by low signal-to-noise ratios. In this study, we design a spectrometer based on a double-beam quantum cascade laser (QCL)-based transmission infrared (IR) source with balanced detection that can significantly enhance sensitivity to nitrile vibrational probes embedded in proteins within cells compared to a conventional FTIR spectrometer. Here, using this approach, we detect small-molecule binding in Escherichia coli, with particular focus on the interaction between para-Coumaric acid (pCA) and nitrile-incorporated photoactive yellow protein (PYP). This system effectively serves as a model for investigating covalent drug binding in a cellular environment. Notably, we observe large spectral shifts of up to 15 cm –1 for nitriles embedded in PYP between the unbound and drug-bound states directly within bacteria, in agreement with observations for purified proteins. Such large spectral shifts are ascribed to the changes in the hydrogen-bonding environment around the local environment of nitriles, accurately modeled through high-level molecular dynamics simulations using the AMOEBA force field. Our findings underscore the QCL spectrometer’s ability to enhance sensitivity for monitoring drug–protein interactions, offering new opportunities for advanced methodologies in drug development and biochemical research.

chromophores↗

Statistical White-Line Analysis in High-Throughput TXM-XANES for Chemical State Quantification

The transmission X-ray microscopy (TXM) based X-ray absorption near-edge structure (XANES) technique provides three-dimensional mapping of element-specific chemical states at nanometer-scale spatial resolution and micrometer-scale fields of view. However, compared to conventional volume-averaged XANES (VA-XANES) measurements, the inherently small voxel size in TXM-XANES leads to a lower signal-to-noise ratio, making full-spectrum analysis computationally demanding and less robust. Here, we present the structural and compositional conditions for a statistical white-line analysis framework under which chemical state information can be directly extracted from the white-line peak position in voxel spectra without the need for voxel-wise background subtraction or normalization, under well-defined structural and compositional conditions. The method is validated on layered oxide cathode materials, where low-order polynomial fitting accurately reproduces white-line features, and the extracted energy distributions correlate strongly with VA-XANES results. This statistical approach enables high-throughput, dose-efficient, and noise-robust chemical state quantification in TXM-XANES, offering broad applicability to functional materials requiring nanoscale oxidation-state mapping.

TXM↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗