Tunable Electromechanical Liquid Crystal Elastomer Actuators

Liquid crystal elastomers (LCE) are soft materials which anisotropically shape morph in response to external stimuli. Herein, a method to produce large‐area carbon nanotube–LCE nanocomposite films with exceptional electrostrictive properties is examined. A methodology to produce telechelic precursor oligomeric composites at scale (>100 g) is presented along with the continuous casting and photocuring process. The carbon nanotubes are well‐aligned and well‐dispersed in the films, which exhibit exceptional anisotropic thermomechanical, optical, and thermal shape change characteristics. When an electric field is applied through the film thickness, the material quickly and reversibly contracts along the alignment direction. As an example, a compliant carbon nanotube–LCE film contracts >4% against a 140 kPa load, roughly comparable to the blocking force of many natural muscular tissues. Furthermore, it is demonstrated that this tunable contraction is dependent upon the electric field strength, and that the contraction mimics the form function of the input electric field (e.g., a sine wave). These compliant actuators are excellent candidates for incorporation into soft and/or biological systems.

36 MATERIALS SCIENCE↗

Improvement of the AC orbit bump method of local kick factor measurement using reference bunches

Here we have improved the AC orbit bump technique of local kick factor measurement. This technique, developed at NSLS-II a few years ago, is based on local sine-wave excitation of the electron beam by four fast correctors adjacent to the impedance location. By implementing reference bunches and the time gate function of beam position monitors, we are now able to measure the AC orbits of bunches with different intensities simultaneously. This improvement allows us to obtain the impedance-driven orbit distortion in a single measurement, significantly improving the measurement accuracy and reducing the measurement time.

36 MATERIALS SCIENCE↗

Tuning Surface Adhesion Using Grayscale Electron-beam Lithography

Surface texturing of manufactured products tailors their properties, such as friction, adhesion, biocompatibility, or fluid interactions. However, advancements in this area are largely the result of trial-and-effort testing and generally lack a science-guided framework for determining the surface topography that will optimize performance. The present investigation explores grayscale electron-beam lithography as a means to create multiscale surface patterns to control surface performance. Here, we created and characterized a set of surface textures on a silicon wafer; the textures were superpositions of sine waves of varying wavelengths and amplitudes. First, the multiscale topography of the patterned surface was characterized, using profilometry and atomic force microscopy, to understand its fidelity to the designed-in pattern. The results of this analysis demonstrated how grayscale lithography accurately controlled the lateral size of features but was less precise on the vertical height of the surface, and also introduced inherent roughness below the scale of patterning. Second, a micromechanical tester was used to characterize the adhesion of the surfaces with large-scale polished silicon spheres. The results showed that adhesion could be tailored, with significant contribution from all of the designed-in length scales of topography. The strength of adhesion did not correlate with conventional roughness parameters but could be accurately modeled using simple numerical integration. Taken together, this investigation demonstrates the promise and challenges of grayscale e-beam lithography with multiscale patterns as a method for the tailoring of surface performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Qubit control noise spectroscopy with optimal suppression of dephasing

Here, we extend quantum noise spectroscopy (QNS) of amplitude control noise to settings where dephasing noise or detuning errors make significant contributions to qubit dynamics. Previous approaches to characterize amplitude noise are limited by their vulnerability to low-frequency dephasing noise and static detuning errors, which can overwhelm the target control noise signal and introduce bias into estimates of the amplitude noise spectrum. To overcome this problem, we leverage optimal control to identify a family of amplitude control waveforms that optimally suppress low-frequency dephasing noise and detuning errors, while maintaining the spectral concentration in the amplitude filter essential for spectral estimation. The waveforms found via numerical optimization have surprisingly simple analytic forms, consisting of oscillating sine waves obeying particular amplitude and frequency constraints. In numerically simulated QNS experiments, these waveforms demonstrate superior robustness, enabling accurate estimation of the amplitude noise spectrum in regimes where existing approaches are biased by low-frequency dephasing noise and detuning errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiscale Richtmyer-Meshkov instability experiments to isolate the strain rate dependence of strength

Theoretical analysis of Richtmyer-Meshkov instability (RMI) experiments for solid strength shows that the strain rate for a given shock should be inversely proportional to the length scale of the sine wave perturbations when η 0 k , the nondimensional amplitude to wavelength ratio, is held fixed. To isolate the effect of strain rate on strength, free-surface RMI specimens of annealed copper were prepared with three perturbation regions with the same η 0 k but different length scales, characterized by the wavelength λ varying by a factor of 4.9 from 65 to 130 to 320 µ m . Three such targets with different fixed η 0 k ′ s were impacted to a shock pressure of 25 GPa, and the instability evolution was measured with photon Doppler velocimetry. Strengths estimated by comparing hydrocode simulation to the data increased from 700 to 1200 MPa as λ decreased. The different η 0 k targets exercised increasing amounts of plastic strain yet showed no evidence of strain hardening. Physical regime sensitivity analysis determined that for 320 − 65 µ m wavelength perturbations, the effective strain rates increased from 8.7 × 10 6 to 3.3 × 10 7 s − 1 , a factor of 3.8. Thus, the predicted strain rate scaling was mostly achieved but slightly suppressed by increased strength at higher rates. The RMI strength estimates were plotted against constitutive testing data on copper from the literature to show striking evidence of the strength upturn at higher strain rates. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Design of 3He Solenoid Power Supply at BNL

The design of the 3He solenoid power supply at Brookhaven National Laboratory (BNL) has been completed and construction is underway. The power supply is an upgrade of the existing Electron Beam Ion Source (EBIS) solenoid power supply and thus can be used as an operational spare. It is also capable of driving a solenoid magnet that rotates the 3He spin direction. The design is based on the original EBIS solenoid power supply, incorporating bipolar output and short circuit protection features to address the expanded requirements for spin rotation. The output current is a half sine wave of 13ms duration at the repetition rate of 5Hz, with the amplitude of 1900A. This paper will discuss the design and construction status of the 3He solenoid power supply.

Tan, Yugang↗

Medium amplitude parallel superposition (MAPS) rheology. Part 2: Experimental protocols and data analysis

An experimental protocol is developed to directly measure the new material functions revealed by medium amplitude parallel superposition (MAPS) rheology. This protocol measures the medium amplitude response of a material to a simple shear deformation composed of three sine waves at different frequencies, revealing a rich dataset consisting of up to 19 measurements of the third-order complex modulus at distinct three-frequency coordinates. We discuss how the choice of input frequencies influences the features of the MAPS domain studied by the experiment. A polynomial interpolation method for reducing the bias of measured values from spectral leakage and reducing variance due to noise is discussed, including a derivation of the optimal range of amplitudes for the input signal. This leads to the conclusion that conducting the experiment in a stress-controlled fashion possesses a distinct advantage to the strain-controlled mode. The experimental protocol is demonstrated through measurements of the MAPS response of a model complex fluid: a surfactant solution of wormlike micelles. The resulting dataset is indeed large and feature-rich, while still acquired in a time comparable to similar medium amplitude oscillatory shear (MAOS) experiments. We demonstrate that the data represent measurements of an intrinsic material function by studying its internal consistency, compatibility with low-frequency predictions for Coleman–Noll simple fluids, and agreement with data obtained via MAOS amplitude sweeps. Finally, the data are compared to predictions from the corotational Maxwell model to demonstrate the power of MAPS rheology in determining whether a constitutive model is consistent with a material’s time-dependent response.

Lennon, Kyle R. (ORCID:0000000212515461)↗

Applying Multi-Frequency AC LOCO for Finding Sextupole Errors

A fast and precise technique of multi-frequency AC LOCO has been developed and tested for finding the sextupole alignment and field-offset errors at NSLS-II. This technique is based on sine-wave beam excitation simultaneously at multiple frequencies via different fast correctors. The unique combination of the fast speed and high measurement accuracy opens the door for two different types of potential applications: finding the sextupole alignment and field-offset errors. Beam excitation via fast correctors results in the elimination of the systematic error caused by the hysteresis effect. Systematic errors of the sextupole alignment caused by orbit drift and power supply calibration are also eliminated because the measurement takes only two minutes and does not depend on the current-to-field conversion of sextupole magnets. Furthermore, the simulation studies indicate that multi-frequency AC LOCO together with an orbit bump bigger than 0.5 mm can be applied to measure the relative field offset of a sextupole magnet with a precision better than 10%. The measurement technique is described and the results of two proof-of-principle experiments carried out at NSLS-II are presented.

43 PARTICLE ACCELERATORS↗

Orbit response measurements with oscillating trajectories

Optical properties of components in a linac can be reconstructed from analysis of the orbit response matrix, composed from responses of BPMs to changes in currents of dipole correctors. An efficient way to record such response, discussed in this note, is to excite the corrector current with a sine wave and record its Fourier component of the BPM spectrum. Because of a narrow band of the excitation signal, response to multiple correctors can be recorded at the same time without significantly affecting the signal-to-noise ratio. For that, the correctors are oscillated at different frequencies, and the corresponding BPM Fourier components are recorded. In an ion (non-relativistic) linac, similar measurements can be performed for the longitudinal plane as well. Examples of measurements at the PIP2IT test linac are shown.

43 PARTICLE ACCELERATORS↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

Spectral Variability of VHS J1256–1257b from 1 to 5 μm

Multiwavelength time-resolved observations of rotationally modulated variability from brown dwarfs and giant exoplanets are the most effective method for constraining their heterogeneous atmospheric structures. In a companion paper, we reported the discovery of strong near-infrared variability in HST/WFC3/G141 light curves of the very red L-dwarf companion VHS J1256–1257b. In this paper, we present a follow-up 36 hr Spitzer/IRAC Channel 2 light curve together with an in-depth analysis of the Hubble space telescope (HST) and the Spitzer data. The combined data set provides time-resolved light curves of VHS1256b sampling 1.1 to 4.5 μm. The Spitzer light curve is best fit with a single sine wave with a period of 22.04 ± 0.05 hr and a peak-to-peak amplitude of 5.76 ± 0.04%. Combining the period with a previously measured projected rotational velocity (v sin i), we find that VHS1256b is most consistent with equatorial viewing geometry. The HST/G141+Spitzer spectral energy distribution favors a model with a T{sub eff} of 1000 K and low surface gravity with disequilibrium chemistry. The spectral variability of VHS1256b is consistent with predictions from partly cloudy models, suggesting that heterogeneous clouds are the dominant source of the observed modulations. We find evidence at the 3.3σ level for amplitude variations within the 1.67 μm CH{sub 4} band, which is the first such detection for a variable L-dwarf. We compare the HST/G141 time-resolved spectra of three red L-dwarfs with high-amplitude near-infrared rotational modulations and find that although their time-averaged spectra are similar, their spectroscopic variabilities exhibit notable differences. This diversity reinforces the advantage of time-resolved spectroscopic observations for understanding the atmospheres of brown dwarfs and directly imaged exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

An unconventional magnetically-coupled multivibrator

Multivibrator circuit provides a low-frequency sine wave output without using a low-frequency power transformer or filter components. This circuit, utilizing two transistors and a magnetic core, represents a reduction in complexity, size, and weight over similar units.

Moore, E. T.↗