Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Adversarial autoencoder ensemble for fast and probabilistic reconstructions of few-shot photon correlation functions for solid-state quantum emitters

Second-order photon correlation measurements [g (2) (τ) functions] are widely used to classify single-photon emission purity in quantum emitters or to measure the multiexciton quantum yield of emitters that can simultaneously host multiple excitations – such as quantum dots – by evaluating the value of g (2) (τ = 0). Accumulating enough photons to accurately calculate this value is time consuming and could be accelerated by fitting of few-shot photon correlations. Here, we develop an uncertainty-aware, deep adversarial autoencoder ensemble (AAE) that reconstructs noise-free g (2) (τ) functions from noise-dominated, few-shot inputs. The model is trained with simulated g (2) (τ) functions that are facilely generated by Poisson sampling time bins. The AAE reconstructions are performed orders-of-magnitude faster, with reconstruction errors and estimates of g (2) (τ = 0) that are lower in variance and similar in accuracy compared to Maximum likelihood estimation and Levenberg-Marquardt least-squares fitting approaches, for simulated and experimentally measured few-shot g (2) (τ) functions (~100 two-photon events) of InP/ZnS/ZnSe and CdS/CdSe/CdS quantum dots. The deep-ensemble model comprises eight individual autoencoders, allowing for probabilistic reconstructions of noise-free g (2) (τ) functions, and we show that the predicted variance scales inversely with number of shots, with comparable uncertainties to computationally intensive Markov chain Monte Carlo sampling. Furthermore, this work demonstrates the advantage of machine learning models to perform uncertainty-aware, fast, and accurate reconstructions of simple Poisson-distributed photon correlation functions, allowing for on-the-fly reconstructions and accelerated materials characterization of solid-state quantum emitters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of Single-Top-Quark Production in Association with a Photon Using the ATLAS Detector

This Letter reports the observation of single top quarks produced together with a photon, which directly probes the electroweak coupling of the top quark. The analysis uses 139 fb -1 of 13 TeV proton-proton collision data collected with the ATLAS detector at the Large Hadron Collider. Requiring a photon with transverse momentum larger than 20 GeV and within the detector acceptance, the fiducial cross section is measured to be 688±23(stat) $^{+75}_{-71}$(syst) fb, to be compared with the standard model prediction of 515$^{+36}_{-42}$ fb at next-to-leading order in QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing TES Power Noise for Future Single Optical-Phonon and Infrared-Photon Detectors

In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Ring Imaging Cherenkov Detector

A ring imaging Cherenkov (RICH) detector has been installed in the CLAS12 spectrometer at Jefferson Laboratory (JLab) to provide kaon identification in the momentum range between 3 GeV/c and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors, and highly segmented photon detectors. We report here on the design, construction, and initial performance of the RICH during the commissioning of the detector and the first physics data taking period

PID detectors↗

Hexagonal boron nitride: Epitaxial growth and device applications

As a newest family member of the III-nitrides, BN is considered amongst the remaining frontiers in wide energy bandgap semiconductors with potentials for technologically significant applications in deep UV (DUV) optoelectronics, solid-state neutron detectors, electron emitters, single photon emitters, switching/memory devices, and super-capacitors. It was shown that it is possible to produce h-BN epilayers with high hexagonal phase purity, UV transparency, and film stoichiometry by employing nitrogen-rich growth conditions. The quasi-2D nature of h-BN supports unusually strong optical transitions near the band edge and a large exciton binding energy on the order of 0.7 eV. Since the isotope of B-10 has a large capture cross-section for thermal neutrons, h-BN is an ideal material for the fabrication of solid-state neutron detectors for special nuclear materials detection, well and geothermal logging, and medical imaging applications. Freestanding B-10 enriched h-BN (h- 10 BN) epilayers with varying thicknesses up to 200 μm have been successfully synthesized by metal organic chemical vapor deposition (MOCVD) as of this writing. By utilizing the conductivity anisotropy nature of h-BN, 1 cm 2 lateral detectors fabricated from 100 μm thick h-10BN epilayers have demonstrated a detection efficiency of 59% for thermal neutrons, which is the highest on record among all solid-state neutron detectors as of today. It was noted that high growth temperatures, long growth times and the use of sapphire substrate tend to incorporate oxygen related impurities into h- 10 BN epilayers, which strongly impacted the carrier mobility-lifetime (μτ) products and charge collection efficiencies of h- 10 BN neutron detectors. As the h-BN material technology further develops, improved carrier mobilities and μτ products will allow the fabrication of h-BN devices with enhanced performance.

42 ENGINEERING↗

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Development of Single Photon Sources in GaN

The recent discovery of bright, room-temperature, single photon emitters in GaN leads to an appealing alternative to diamond best single photon emitters given the widespread use and technological maturity of III-nitrides for optoelectronics (e.g. blue LEDs, lasers) and high-speed, high-power electronics. This discovery opens the door to on-chip and on-demand single photon sources integrated with detectors and electronics. Currently, little is known about the underlying defect structure nor is there a sense of how such an emitter might be controllably created. A detailed understanding of the origin of the SPEs in GaN and a path to deterministically introduce them is required. In this project, we develop new experimental capabilities to then investigate single photon emission from GaN nanowires and both GAN and AlN wafers. We ion implant our wafers with the ion implanted with our focused ion beam nanoimplantation capabilities at Sandia, to go beyond typical broad beam implantation and create single photon emitting defects with nanometer precision. We've created light emitting sources using Li + and He + , but single photon emission has yet to be demonstrated. In parallel, we calculate the energy levels of defects and transition metal substitutions in GaN to gain a better understanding of the sources of single photon emission in GaN and AlN. The combined experimental and theoretical capabilities developed throughout this project will enable further investigation into the origins of single photon emission from defects in GaN, AlN, and other wide bandgap semiconductors.

36 MATERIALS SCIENCE↗

An Update on MicroBooNE’s Inclusive Single Photon Low Energy Excess Search

The MicroBooNE detector is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the "low-energy-excess" anomaly seen by MiniBooNE. MicroBooNE's currently published results see no excess consistent with the MiniBooNE observation, emphasizing a need for improved searches in more channels. This note summarizes MicroBooNE's inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which is used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 7.0% efficiency and 40.2% purity is achieved for our targeted single photon signal simulated events.

43 PARTICLE ACCELERATORS↗

Experiments with Undulator Radiation, Emitted by a Single Electron

We study a single electron, circulating in the Fermilab IOTA storage ring and interacting with an undulator through single and multi-photon emissions. The focus of this research is on single-photon and two-photon undulator emissions. We begin by using one Single Photon Avalanche Diode (SPAD) detector to detect the undulator radiation photons and search for possible deviations from the expected Poissonian photon statistics. Then, we go on to use a two-photon interferometer consisting of two SPAD detectors separated by a beam splitter. This allows to test if there is any correlation in the detected photon pairs. In addition, the photocount arrival times can be used to track the longitudinal motion of a single electron and to compare it with simulations. This allowed us to determine several dynamical parameters of the storage ring such as the rf cavity phase jitter and the dependence of the synchrotron motion period on amplitude.

43 PARTICLE ACCELERATORS↗

The Role of Metal-Semiconductor Interface in Hybrid Perovskite Devices for High-Performance Radiation Photon Counting

Halide perovskites are promising optoelectronic semiconductors. For applications in solid-state detectors that operate in low photon flux counting mode, blocking interfaces are essential to minimize the dark current noise. Here, we investigate the interface between methylammonium lead tri-iodide (MAPbI 3 ) single crystals and commonly used high and low work function metals to achieve photon counting capabilities in a solid-state detector. Using scanning photocurrent microscopy, we observe a large Schottky barrier at the MAPbI 3 /Pb interface, which efficiently blocks dark current. Moreover, the shape of the photocurrent profile indicates that the MAPbI 3 single-crystal surface has a deep fermi level close to that of Au. Rationalized by first-principle calculations, we attribute this observation to the defects due to excess iodine on the surface underpinning emergence of deep band-edge states. The photocurrent decay profile yields a charge carrier diffusion length of 10–25 μm. Using this knowledge, we demonstrate a single-crystal MAPbI 3 detector that can count single γ-ray photons by producing sharp electrical pulses with a fast rise time of <2 μs. Overall, our study indicates that the interface plays a crucial role in solid-state detectors operating in photon counting mode.

36 MATERIALS SCIENCE↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic-quenching of a single-photon avalanche photodetector using an adaptive resistive switch

One of the most common approaches for quenching single-photon avalanche diodes is to use a passive resistor in series with it. A drawback of this approach has been the limited recovery speed of the single-photon avalanche diodes. High resistance is needed to quench the avalanche, leading to slower recharging of the single-photon avalanche diodes depletion capacitor. We address this issue by replacing a fixed quenching resistor with a bias-dependent adaptive resistive switch. Reversible generation of metallic conduction enables switching between low and high resistance states under unipolar bias. As an example, using a Pt/Al 2 O 3 /Ag resistor with a commercial silicon single-photon avalanche diodes, we demonstrate avalanche pulse widths as small as ~30 ns, 10× smaller than a passively quenched approach, thus significantly improving the single-photon avalanche diodes frequency response. The experimental results are consistent with a model where the adaptive resistor dynamically changes its resistance during discharging and recharging the single-photon avalanche diodes.

42 ENGINEERING↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗