Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE-PHASE FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of grain size and geometrically necessary dislocation density dependence of flow stress in Mg-4Al by using nanoindentation

Models for grain size dependence of flow stress typically ignore contributions from geometrically necessary dislocations (GNDs) in the grain boundary regions. Ashby had proposed the following equation for flow stress (τ) as a function of grain size (d) and effective plastic strain ($\bar{ε}$): $τ = τ_{0} + C'G\sqrt{^{b\bar{ε}}_{d}}$ using an unknown empirical coefficient, C’, In this study, the coefficient, C’, and equation for the grain size dependence of flow stress were investigated in Mg-4Al using nanoindentation. C’ ranges from 1.4 to 7.11 that is related to the hardness difference (∆H0) between the adjacent grains as $C' + 0.62\sqrt{ΔH_{0}}$. Ashby equation was used to predict uniaxial stress-strain curves in grain sizes of 55 µm, 187 µm, and 333 µm. The results showed lower flow stress and lower hardening rate compared to experimentally measured tensile stress-strain response. The discrepancy seems to be a result of hardening effect of SSDs. Here, we propose a modified Ashby equation that takes into account the hardening effect of SSDs and GNDs separately, resulting in a better agreement between calculated and experimentally measured values. This analysis demonstrates estimation of uniaxial stress-strain response using nanoindentation measurements that captures effects of grain size, and strain hardening from SSDs and GNDs. The combination of the revised equation and nanoindentation method will enable rapid exploration of stress-strain response of a diverse range of single-phase polycrystalline alloys.

36 MATERIALS SCIENCE↗

STAT7 v1.2 User Guide: The STAT7 Code for Statistical Propagation of Uncertainties in Steady-State Thermal Hydraulics Analysis of Plate-Fueled Reactors

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software is for non-power research and test reactors, including conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors such as Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat analysis during fuel reloading, STAT7 accommodates flexibility in analyzing many realistic aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for thermal hydraulics analyses of research and test reactors. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to the fit functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze all of the axial nodes of all of the fuel plates and all of the coolant channels for one latera stripe of a fuel element. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. By running STAT7 multiple times, full core analysis can be performed by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

STAT7 v2.0 User Guide

The STAT7 software was developed to perform steady-state, single-phase thermal hydraulics analysis of plate-fueled reactors based on statistical propagation of uncertainties. Application of the software includes non-power research and test reactor analysis, and it has been used for the conversion to low- enriched uranium fuel of U.S. High Performance Research Reactors such as the Massachusetts Institute of Technology Research Reactor. Since it can be necessary to repeat reactor safety analysis, such as during fuel reloading, STAT7 accommodates flexibility in analyzing many practical aspects of reactor fuel management. STAT7 uses a Monte Carlo approach to model uncertainty in common fuel fabrication parameters and other key reactor operating parameters required for reactor thermal hydraulics analysis. These safety calculations are ultimately intended to protect against high fuel plate temperatures due to critical heat flux, or onset of flow instability. STAT7 supports water properties based on the IAPWS-IF97 functions (The International Association for the Properties of Water and Steam Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam) in addition to fitted functions. STAT7 predicts axial profiles of fuel, cladding, and coolant temperature along a lateral stripe that runs the full length of the fuel plate from the bottom to the top. STAT7 can simultaneously analyze every axial node in each lateral stripe of all fuel plates and coolant channels in every fuel element of an entire reactor core. Power splits are calculated for each axial node of each plate to determine how much of the power goes out each face of the plate. In a single execution, STAT7 can be used to perform full core analysis by analyzing the margin to onset of nucleate boiling and onset of flow instability for each axial node of each stripe of each plate of each fuel element in the core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation of Multi-Mode heat transfer to a Free-Falling dilute particle cloud in a heated vertical tube

The development of dilute particle heat exchangers and reactors for advanced energy systems requires an understanding of the multi-mode heat transfer from a heated wall to falling particles. This study presents experimental results of the overall heat transfer coefficient for a free-falling, dilute flow of particles with solid volume fraction from 0.0005 to 0.006 corresponding to feed rates from 3.7 kg s -1 m -2 to 44 kg s -1 m -2 in a vertical, heated tube containing quiescent air at atmospheric pressure. Tube wall temperatures are varied between 300°C to 900°C while keeping the particle inlet temperature constant. The experimental results show that the overall heat transfer coefficient is a strong function of particle feed rate and surface temperature. Good agreement was obtained with prior studies conducted at comparable temperatures but lower particle feed rates (< 4 kg m -2 s -1 ). The established correlations for particle-to-wall radiation and particle-to-gas convection were used to estimate the wall-to-gas convective contribution from the measured overall heat transfer coefficient. The experimental results indicated a 4 to 6 times improvement in the wall convection in the solid-gas mixture compared to that expected from natural convection in a single-phase gas. Furthermore, the data presented here are applicable to characterize heat transfer in dilute particle heat exchangers, furnaces, and solar receivers.

14 SOLAR ENERGY↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

Newton trust-region methods with primary variable switching for simulating high temperature multiphase porous media flow

Coupling multiphase flow with energy transport due to high temperature heat sources introduces significant new challenges since boiling and condensation processes can lead to dry-out conditions with subsequent re-wetting. The transition between two-phase and single-phase behavior can require changes to the primary dependent variables adding discontinuities as well as extending constitutive nonlinear relations to extreme physical conditions. Practical simulations of large-scale engineered domains lead to Jacobian systems with a very large number of unknowns that must be solved efficiently using iterative methods in parallel on high-performance computers. Performance assessment of potential nuclear repositories, carbon sequestration sites and geothermal reservoirs can require numerous Monte-Carlo simulations to explore uncertainty in material properties, boundary conditions, and failure scenarios. Due to the numerical challenges, standard NR iteration may not converge over the range of required simulations and require more sophisticated optimization method like trust-region. In this study, we use the open-source simulator PFLOTRAN for the important practical problem of the safety assessment of future nuclear waste repositories in the U.S. DOE geologic disposal safety assessment Framework. The simulator applies the PETSc parallel framework and a backward Euler, finite volume discretization. We demonstrate failure of the conventional NR method and the success of trust-region modifications to Newton’s method for a series of test problems of increasing complexity. Trust-region methods essentially modify the Newton step size and direction under some circumstances where the standard NR iteration can cause the solution to diverge or oscillate. Furthermore, we show how the Newton Trust-Region method can be adapted for Primary Variable Switching (PVS) when the multiphase state changes due to boiling or condensation. The simulations with high-temperature heat sources which led to extreme nonlinear processes with many state changes in the domain did not converge with NR, but they do complete successfully with the trust-region methods modified for PVS. This implementation effectively decreased weeks of simulation time needing manual adjustments to complete a simulation down to a day. Finally, we show the strong scalability of the methods on a single node and multiple nodes in an HPC cluster.

54 ENVIRONMENTAL SCIENCES↗

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration↗

An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Crystallographic Study of Product Phases of Carbothermic Reduction and Nitridation of Hafnium Dioxide

Details of the carbothermic reduction/nitridation to synthesize hafnium nitride (HfN) and hafnium carbide (HfC) are scarce in the literature. Therefore, this current study was carried out to evaluate two pathways for synthesizing these two refractory materials: direct nitridation and carbothermic reduction/nitridation. Two mixtures of hafnium dioxide and carbon with C/HfO 2 molar ratios of 2.15 and 3.1 were nitridized directly using flowing nitrogen gas at elevated temperatures (1300–1700 °C). The 3.1 C/HfO 2 molar ratio mixture was also carbothermically reduced under flowing argon gas to synthesize HfC, which was converted into HfN by introducing a nitridation step under both N 2(g ) and N 2(g) -10% H 2(g) . X-ray diffraction results showed the formation of HfN at 1300 and 1400 °C and HfC 1–y N y at ≥1400 °C under direct nitridation of samples using a C/HfO 2 molar ratio of 2.15. These phase analysis data together with lower lattice strain and greater crystallite sizes of HfC 1–y N y that formed at higher temperatures suggested that the HfC 1–y N y phase is preferred over HfN at those temperatures. Carbothermic reduction of 3.1 C/HfO 2 molar ratio samples under an inert atmosphere produced single-phased HfC with no significant levels of dissolved oxygen. In conclusion, carbothermic reduction nitridation made two phases of different carbon levels (HfC 1–y N y and HfC 1–y 'N y ', where y' < y), while direct nitridation produced a single HfC 1–y N y phase under both N 2 and N 2 -10% H 2 cover gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Swinging Hydrogen Evolution to Nitrate Reduction Activity in Molybdenum Carbide by Ruthenium Doping

A common challenge for electrochemical ammonia synthesis in an aqueous phase is the consumption of Faradaic charge by the competing hydrogen evolution reaction (HER), which reduces the Faradaic efficiency for the desired conversion, i.e., the nitrate reduction reaction (NO 3 RR) to ammonium. This problem is particularly severe when a single-phase catalyst is operated at high current limits, thus a cocatalyst system that works synergistically for hydrogen acquisition and deoxygenation is needed to promote NO 3 RR over HER. For this study, we select a well-known HER catalyst Mo 2 C and investigate how metal doping can switch its kinetics from HER-dominated to NO 3 RR-dominated pathways. At 3.8 wt % Ru doping of Mo 2 C, a 75% single pass conversion of nitrate (0.1 M) to ammonium in a 16 cm 2 flow electrolyzer was achieved, corresponding to an ammonium yield rate of 9.07 mmol h –1 at a full cell voltage of 2 V. As confirmed by DFT calculations and kinetic isotope experiments, ruthenium dopants in the matrix serve as the sink point for adsorbed hydrogen during NO 3 RR to promote the cooperative deoxygenation of *NO 3 and *NO 2 on the Ru–Mo cocatalytic site. Our study suggests that optimizing hydrogen acquisition and deoxygenation reactions in cocatalytic systems is an effective strategy for electrochemical synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

Exceptional fracture toughness of CrCoNi-based medium- and high-entropy alloys at 20 kelvin

Medium- and high-entropy alloys based on the CrCoNi-system have been shown to display outstanding strength, tensile ductility and fracture toughness (damage-tolerance properties), especially at cryogenic temperatures. Here we examine the J Ic and (back-calculated) K JIc fracture toughness values of the face-centered cubic, equiatomic CrCoNi and CrMnFeCoNi alloys at 20 K. At flow stress values of ~1.5 GPa, crack-initiation K JIc toughnesses were found to be exceptionally high, respectively 235 and 415 MPa√m for CrMnFeCoNi and CrCoNi, with the latter displaying a crack-growth toughness K ss exceeding 540 MPa√m after 2.25 mm of stable cracking, which to our knowledge is the highest such value ever reported. Characterization of the crack-tip regions in CrCoNi by scanning electron and transmission electron microscopy reveal deformation structures at 20 K that are quite distinct from those at higher temperatures and involve heterogeneous nucleation, but restricted growth, of stacking faults and fine nanotwins, together with transformation to the hexagonal closed-packed phase. The coherent interfaces of these features can promote both the arrest and transmission of dislocations to generate respectively strength and ductility which strongly contributes to sustained strain hardening. Indeed, we believe that these nominally single-phase, concentrated solid-solution alloys develop their fracture resistance through a progressive synergy of deformation mechanisms, including dislocation glide, stacking-fault formation, nano-twinning and eventually in situ phase transformation, all of which serve to extend continuous strain hardening which simultaneously elevates strength and ductility (by delaying plastic instability), leading to truly exceptional resistance to fracture.

36 MATERIALS SCIENCE↗

Improved Water Sound Synthesis using Coupled Bubbles

We introduce a practical framework for synthesizing bubble-based water sounds that captures the rich inter-bubble coupling effects responsible for low-frequency acoustic emissions from bubble clouds. We propose coupled-bubble oscillator models with regularized singularities, and techniques to reduce the computational cost of time stepping with dense, time-varying mass matrices. Airborne acoustic emissions are estimated using finite-difference time-domain (FDTD) methods. We propose a simple, analytical surface-acceleration model, and a sample-and-hold GPU wavesolver that is simple and faster than prior CPU wavesolvers. Sound synthesis results are demonstrated using bubbly flows from incompressible, two-phase simulations, as well as procedurally generated examples using single-phase FLIP fluid animations. Our results demonstrate sound simulations with hundreds of thousands of bubbles, and perceptually significant frequency transformations with fuller low-frequency content.

Computer Science↗

FY-25 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the system level modeling using RELAP5-3D of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY25. This year’s work focuses on a new tank configuration where the inlet of the tank was lowered in elevation by 45”. The stability boundaries of the NSTF are thoroughly studied and stability maps are constructed based on the stability and the oscillation patterns of the system. Five distinct operational modes are identified, namely single-phase liquid, uniform double peak oscillations, uniform sinusoidal oscillations, stable two-phase flow, and non-uniform oscillations. Next, the riser inlet throttling case of experimental test Run-104 is simulated with the RELAP5 model where good agreement is obtained between the model and the experimental data. The simulation also highlights the effects of backflow of water from the tank to the upper region of the chimney. Additionally, the decay heat removal test of Run-99 is simulated with the RELAP5 model. Comparison is carried out between this run and a similar run with the mid-tank inlet of Run-74 performed in FY22. With the lower tank inlet, the RELAP5 model is able to predict the experimental data more accurately than the previous mid tank inlet configuration. The discrepancy in model prediction accuracy highlights the non-symmetrical spatial effects in the tank that would otherwise be more easily captured with higher fidelity models. Lastly, two exploratory studies are conducted to investigate the behaviors of the NSTF when 1) heating is provided to the downcomer and 2) a bypass channel is added between the horizontal chimney section to the downcomer.

42 ENGINEERING↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗